Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Comput Biol Med ; 179: 108695, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38968763

RESUMEN

This study uses CFD methods to investigate the effects of the impeller's geometry on the hemodynamic characteristics, pump performance, and blood damage parameters, in a percutaneous microaxial Mechanical Circulatory Support (MCS) device. The numerical simulations employ the steady state Reynolds-Averaged Navier-Stokes approximation using the SST k-ω turbulent model. Three different impeller models are examined with different hub conversion angles (α = 0○, 3○ and 5○). The analysis includes 23 cases for different pressure heads (Δp = 60-80 mmHg) and angular velocities (ω = 30-52 kRPM). The obtained flow rate is compared between the cases to assess the effect of the impeller's design and working conditions on the pump performance. The comparative risk of shear-induced platelet activation is estimated using the statistical median of the stress-accumulation values calculated along streamlines. The risk of hemolysis is estimated using the average exposure time to shear stress above a threshold (τ > 425 Pa). The results reveal that the shape of the impeller's hub has a great impact on the flow patterns, performance, and risk of blood damage, as well as the angular velocity. The highest flow rate (Q = 3.7 L/min) and efficiency (η = 11.3 %) were achieved using a straight hub (α = 0○). Similarly, for the same condition of flow and pressure, the straight hub impeller has the lowest blood damage risk parameters. This study shed light on the effect of pump design on the performance and risk of blood damage, indicating the roles of the hub shape and angular velocity as dominant parameters.


Asunto(s)
Corazón Auxiliar , Modelos Cardiovasculares , Humanos , Hemólisis , Simulación por Computador , Hemodinámica , Estrés Mecánico
2.
Stem Cell Res ; 47: 101888, 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-32688331

RESUMEN

Recent advances of stem cell-based therapies in clinical trials have raised the need for large-scale manufacturing platforms that can supply clinically relevant doses to meet an increasing demand. Promising results have been reported using stirred-tank bioreactors, where human Mesenchymal Stromal Cells (hMSCs) were cultured in suspension on microcarriers (MCs), although the formation of microcarrier-cell-aggregates might still limit mass transfer and determine a heterogeneous distribution of hMSCs. A variety of MCs, bioreactor-impeller configurations, and agitation conditions have been established in an attempt to overcome the trade-off of ensuring good suspension while keeping the stresses to a minimum. While understanding and controlling the fluid flow environment of bioreactors has been initially under-appreciated, it has recently gained in popularity in the mission of providing ideal culture environments across different scales. This review article aims to provide a comprehensive overview of how rigorous engineering characterisation studies improved the outcome of biological process development and scale-up efforts. Reconciling these two disciplines is crucial to propose tailored bioprocessing solutions that can provide improved growth environments across a range of scales for the allogeneic cell therapies of the future.

3.
Int J Artif Organs ; 41(11): 730-737, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29998774

RESUMEN

AIMS:: Impeller design has a significant impact on the overall performance of a blood pump. In this study, the effect of the blade curvature was investigated by performing in silico and in vitro studies on a recently developed centrifugal blood pump. METHODS:: A computational fluid dynamics study was performed for the flow rates of 3-5 L/min at 2000 r/min. The computational fluid dynamics model was also applied on the US Food and Drug Administration (FDA) benchmark blood pump to validate our computational method. The relative hemolysis index was calculated with the Eulerian hemolysis estimation method for five impellers with the wrap angles ranging from 0° to 240°. Hydraulic experiments were conducted for the validation of computational fluid dynamics results. In addition, the curved-blade impeller (120°) and the straight-blade impeller (0°) were evaluated with in vitro hemolysis tests using human blood. RESULTS:: The wrap angle of 120° provided the best hydraulic and hemolytic performance. Pump achieved the physiologic operating pressures and flows with 85-115 mmHg at 2.5-5.9 L/min. Compared to the straight-blade impeller, the 120° model reduces the relative hemolysis index and the plasma-free hemoglobin near 72.8% and 56.7%, respectively. Comparison of in silico and in vitro results indicated the similar trend to the blade curvature. CONCLUSION:: Introducing a blade curvature enhanced the hydrodynamic and hemolytic performance compared to the straight-blade configuration for the investigated centrifugal blood pump. The findings of this study provide new insights into centrifugal blood pump design by examining the influence of the blade curvature.


Asunto(s)
Diseño de Equipo , Corazón Auxiliar , Simulación por Computador , Hemólisis/fisiología , Humanos , Hidrodinámica
4.
Molecules ; 23(2)2018 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-29495254

RESUMEN

The synthesis of kojic acid derivative (KAD) from kojic and palmitic acid (C16:0) in the presence of immobilized lipase from Rhizomucor miehei (commercially known as Lipozyme RMIM), was studied using a shake flask system. Kojic acid is a polyfunctional heterocycles that acts as a source of nucleophile in this reaction allowing the formation of a lipophilic KAD. In this study, the source of biocatalyst, Lipozyme RMIM, was derived from the lipase of Rhizomucor miehei immobilized on weak anion exchange macro-porous Duolite ES 562 by the adsorption technique. The effects of solvents, enzyme loading, reaction temperature, and substrate molar ratio on the reaction rate were investigated. In one-factor-at-a-time (OFAT) experiments, a high reaction rate (30.6 × 10-3 M·min-1) of KAD synthesis was recorded using acetone, enzyme loading of 1.25% (w/v), reaction time of 12 h, temperature of 50 °C and substrate molar ratio of 5:1. Thereafter, a yield of KAD synthesis was optimized via the response surface methodology (RSM) whereby the optimized molar ratio (fatty acid: kojic acid), enzyme loading, reaction temperature and reaction time were 6.74, 1.97% (w/v), 45.9 °C, and 20 h respectively, giving a high yield of KAD (64.47%). This condition was reevaluated in a 0.5 L stirred tank reactor (STR) where the agitation effects of two impellers; Rushton turbine (RT) and pitch-blade turbine (PBT), were investigated. In the STR, a very high yield of KAD synthesis (84.12%) was achieved using RT at 250 rpm, which was higher than the shake flask, thus indicating better mixing quality in STR. In a rheological study, a pseudoplastic behavior of KAD mixture was proposed for potential application in lotion formulation.


Asunto(s)
Lipasa/química , Pironas/química , Rhizomucor/química , Solventes/química , Acetona/química , Rastreo Diferencial de Calorimetría , Catálisis , Técnicas de Química Sintética , Esterificación , Cinética , Modelos Químicos , Pironas/síntesis química , Reología , Temperatura , Termodinámica , Termogravimetría
5.
Ann Biomed Eng ; 46(3): 417-428, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29094293

RESUMEN

Patients with ventricular assist devices still suffer from high rates of adverse events. Since many of these complications are linked to the flow field within the pump, optimization of the device geometry is essential. To investigate design aspects that influence the flow field, we developed a centrifugal blood pump using industrial guidelines. We then systematically varied selected design parameters and investigated their effects on hemodynamics and hydraulic performance using computational fluid dynamics. We analysed the flow fields based on Eulerian and Lagrangian features, shear stress histograms and six indicators of hemocompatibility. Within the investigated range of clearance gaps (50-500 µm), number of impeller blades (4-7), and semi-open versus closed shroud design, we found association of potentially damaging shear stress conditions with larger gap size and more blades. The extent of stagnation and recirculation zones was reduced with lower numbers of blades and a semi-open impeller, but it was increased with smaller clearance. The Lagrangian hemolysis index, a metric commonly applied to estimate blood damage, showed a negative correlation with hydraulic efficiency and no correlation with the Eulerian threshold-based metric.


Asunto(s)
Diseño de Equipo , Corazón Auxiliar , Ensayo de Materiales , Humanos
6.
Artif Organs ; 38(12): 1007-17, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24749994

RESUMEN

Providing partial respiratory assistance by removing carbon dioxide (CO2 ) can improve clinical outcomes in patients suffering from acute exacerbations of chronic obstructive pulmonary disease and acute respiratory distress syndrome. An intravenous respiratory assist device with a small (25 Fr) insertion diameter eliminates the complexity and potential complications associated with external blood circuitry and can be inserted by nonspecialized surgeons. The impeller percutaneous respiratory assist catheter (IPRAC) is a highly efficient CO2 removal device for percutaneous insertion to the vena cava via the right jugular or right femoral vein that utilizes an array of impellers rotating within a hollow-fiber membrane bundle to enhance gas exchange. The objective of this study was to evaluate the effects of new impeller designs and impeller spacing on gas exchange in the IPRAC using computational fluid dynamics (CFD) and in vitro deionized water gas exchange testing. A CFD gas exchange and flow model was developed to guide a progressive impeller design process. Six impeller blade geometries were designed and tested in vitro in an IPRAC device with 2- or 10-mm axial spacing and varying numbers of blades (2-5). The maximum CO2 removal efficiency (exchange per unit surface area) achieved was 573 ± 8 mL/min/m(2) (40.1 mL/min absolute). The gas exchange rate was found to be largely independent of blade design and number of blades for the impellers tested but increased significantly (5-10%) with reduced axial spacing allowing for additional shaft impellers (23 vs. 14). CFD gas exchange predictions were within 2-13% of experimental values and accurately predicted the relative improvement with impellers at 2- versus 10-mm axial spacing. The ability of CFD simulation to accurately forecast the effects of influential design parameters suggests it can be used to identify impeller traits that profoundly affect facilitated gas exchange.


Asunto(s)
Dióxido de Carbono/sangre , Catéteres , Diseño de Equipo , Insuficiencia Respiratoria/sangre , Insuficiencia Respiratoria/terapia , Humanos , Intercambio Gaseoso Pulmonar
7.
Materials (Basel) ; 6(5): 2074-2089, 2013 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-28809261

RESUMEN

South African fly ash has been shown to be a useful feedstock for the synthesis of some zeolites. The present study focuses on the effect of impeller design and agitation rates on the synthesis of zeolite Na-P1 which are critical to the commercialization of this product. The effects of three impeller designs (4-flat blade, Anchor and Archimedes screw impellers) and three agitation speeds (150, 200 and 300 rpm) were investigated using a modified previously reported synthesis conditions; 48 hours of ageing at 47 °C and static hydrothermal treatment at 140 °C for 48 hours. The experimental results demonstrated that the phase purity of zeolite Na-P1 was strongly affected by the agitation rate and the type of impeller used during the ageing step of the synthesis process. Although zeolite Na-P1 was synthesized with a space time yield (STY) of 15 ± 0.4 kg d-1m-3and a product yield of 0.98±0.05 g zeolites/g fly ash for each impeller at different agitation speeds, zeolite formation was assessed to be fairly unsuccessful in some cases due the occurrence of undissolved mullite and/or the formation of impurities such as hydroxysodalite with the zeolitic product. This study also showed that a high crystalline zeolite Na-P1 can be synthesized from South African coal fly ash using a 4-flat blade impeller at an agitation rate of 200 rpm during the ageing step at 47 °C for 48 hours followed by static hydrothermal treatment at 140 °C for 48 hours.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA