Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.686
Filtrar
2.
Clin Kidney J ; 17(9): sfae247, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39246629

RESUMEN

Background: The diagnosis of acute myocardial infarction (AMI) using high-sensitivity cardiac troponin T (hs-cTnT) remains challenging in patients with kidney dysfunction. Methods: In this large, multicenter cohort study, a total of 20 912 adults who underwent coronary angiography were included. Kidney function-specific cut-off values of hs-cTnT were determined to improve the specificity without sacrificing sensitivity, as compared with that using traditional cut-off value (14 ng/L) in the normal kidney function group. The diagnostic accuracy of the novel cut-off values was validated in an independent validation cohort. Results: In the derivation cohort (n = 12 900), 3247 patients had an estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2. Even in the absence of AMI, 50.2% of participants with eGFR <60 mL/min/1.73 m2 had a hs-cTnT concentration ≥14 ng/L. Using 14 ng/L as the threshold of hs-cTnT for diagnosing AMI led to a significantly reduced specificity and positive predictive value in patients with kidney dysfunction, as compared with that in patients with normal kidney function. The kidney function-specific cut-off values were determined as 14, 18 and 48 ng/L for patients with eGFR >60, 60-30 and <30 mL/min/1.73 m2, respectively. Using the novel cut-off values, the specificities for diagnosing AMI in participants with different levels of kidney dysfunction were remarkably improved (from 9.1%-52.7% to 52.8-63.0%), without compromising sensitivity (96.6%-97.9%). Similar improvement of diagnostic accuracy was observed in the validation cohort (n = 8012). Conclusions: The kidney function-specific cut-off values of hs-cTnT may help clinicians to accurately diagnose AMI in patients with kidney dysfunction and avoid the potential overtreatment in practice.

3.
Am Heart J Plus ; 45: 100441, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39246678

RESUMEN

Background: Magnetocardiography (MCG) may provide a rapid diagnostic option for patients presenting with chest pain in the emergency department (ED). Case summaries: This case series presents two instances from a multicenter study, where MCG could have served as a rapid, non-invasive diagnostic tool for chest pain patients. In both cases, multiple high-sensitivity troponin (hsTn) tests yielded incorrect evidence of ischemia. In the first case, multiple positive hsTn tests led to the patient requiring 23 h of observation care, while MCG rapidly ruled out acute coronary syndrome (ACS). In the second case, MCG revealed findings indicative of cardiac ischemia where serial ECGs did not indicate ischemia and serial hsTns were normal. Subsequent cardiac catheterization confirmed 99 % stenosis in the patient's left main and left anterior descending arteries, necessitating coronary artery bypass grafting (CABG). Conclusion: MCG offers a rapid, painless, non-invasive, radiation free assessment for patients presenting with acute chest pain. Integrating MCG into ED workflows has the potential to improve throughput, reduce the need for subsequent patient observation or inpatient admission, and minimize or eliminate the need for other more expensive non-invasive cardiac testing. MCG avoids some of the problems associated with other methods for diagnosing ischemia. MCG does not involve radiation or the use of pharmacologic agents which have a risk for allergic reactions and anaphylaxis, or the need for an intravenous line. Stress tests are frequently contraindicated or unable to be performed in patients on various medications, may require patient cooperation and in the case of exercise stress tests, the patient's capability to exercise. MCG requires no special patient preparation.

4.
Cureus ; 16(8): e66512, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39246852

RESUMEN

BACKGROUND:  Evaluating high-sensitivity troponin I levels in emergency medicine is critical for diagnosing acute myocardial infarction (AMI). This study aims to evaluate the central laboratory versus bedside troponin I test in the emergency department of a tertiary care center. MATERIAL AND METHODS:  This prospective observational study was conducted at Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pune, Maharashtra, India, from October to December 2023. Patient samples were analyzed in the central laboratory using the Dimension EXL 200 (Siemens® Healthcare Diagnostics Inc., Erlangen, Germany) as the gold standard test and through point-of-care testing using the TriageTrue® (Quidel Corporation, San Diego, CA) high-sensitivity troponin I kit, which was run on the Triage® MeterPro® device (Quidel Corporation, San Diego, CA). This device quantitatively determines troponin I in ethylenediaminetetraacetic acid-anticoagulated whole blood and plasma specimens. The results were compared. Statistical analysis was performed using SPSS version 18 (SPSS Inc., Chicago, IL). An unpaired t-test was performed to compare the difference in time taken using the two testing methods. RESULT:  The mean time for obtaining troponin I results was substantially shorter with bedside testing (14.91 minutes, standard deviation (SD) = 0.5) than with laboratory testing (119.1 minutes, SD = 5.03). Statistical analysis revealed a significant difference (t = -172.36, p < 0.001). A chi-square test was conducted to assess the disparity between the two testing methods, yielding a chi-square value of 32.64 and a p value of 0.00001, indicating a significant difference between bedside testing and laboratory testing. CONCLUSION: The bedside high-sensitivity troponin I test offers a considerable advantage over laboratory testing regarding turnaround time within the emergency medicine department in India. This rapid diagnostic capability is crucial for timely management, which is beneficial for patients inconclusive of acute coronary syndrome-like non-ST segment elevation myocardial infarction (NSTEMI). It is also cost-effective. It also reduces the emergency boarding time and may reduce the number of unnecessary admissions in healthcare facilities.

5.
Talanta ; 281: 126754, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39241646

RESUMEN

Confocal Raman microscopy is a powerful technique for identifying materials and molecular species; however, the signal from Raman scattering is extremely weak. Typically, handheld Raman instruments are cost-effective but less sensitive, while high-end scientific-grade Raman instruments are highly sensitive but extremely expensive. This limits the widespread use of Raman technique in our daily life. To bridge this gap, we explored and developed a cost-effective yet highly sensitive confocal Raman microscopy system. The key components of the system include an excitation laser based on readily available laser diode, a lens-grating-lens type spectrometer with high throughput and image quality, and a sensitive detector based on a linear charge-coupled device (CCD) that can be cooled down to -30 °C. The developed compact Raman instrument can provide high-quality Raman spectra with good spectral resolution. The 3rd order 1450 cm-1 peak of Si (111) wafer shows a signal-to-noise ratio (SNR) better than 10:1, demonstrating high sensitivity comparable to high-end scientific-grade Raman instruments. We also tested a wide range of different samples (organic molecules, minerals and polymers) to demonstrate its universal application capability.

6.
Small ; : e2403495, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39246203

RESUMEN

As the demand for specialized and diversified pressure sensors continues to increase, excellent performance and multi-applicability have become necessary for pressure sensors. Currently, flexible pressure sensors are primarily utilized in fields such as health monitoring and human-computer interaction. However, numerous complex extreme environments in reality, including deep sea, corrosive conditions, extreme cold, and high temperatures, urgently require the services of flexible devices. Here, a piezoresistive flexible pressure sensor based on expanded polytetrafluoroethylene/functionalized carbon nanotubes (EPTFE/FCNT) is proposed. Benefiting from the unique fiber-segment architecture, chemical stability, and strong chemical binding force between EPTFE and FCNT, the fabricated sensor exhibits remarkable sensing capabilities and can be employed in multifarious extreme environments. It demonstrates a sensitivity of 862.28 kPa-1, a response time of 6-7 ms, and a detection limit below 1 Pa. Furthermore, it possesses a pressure resolution of 0.0018% under 111 kPa and can withstand over 10,000 loading and unloading cycles under 1 MPa. Additionally, the EPTFE/FCNT sensor retains its outstanding pressure response and work efficiency in extreme conditions such as an ultra-low temperature of -80 °C, high temperature (200 °C), acidic and alkaline corrosion, and underwater. These notable attributes enormously broaden the sensors' real-world application range.

7.
Talanta ; 281: 126865, 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39265422

RESUMEN

Nonalcoholic fatty liver disease (NAFLD) poses a significant global health concern, necessitating precise diagnostic tools and effective treatment strategies. Peroxynitrite (ONOO-), a reactive oxygen species, plays a pivotal role in NAFLD pathogenesis, highlighting its potential as a biomarker for disease diagnosis and therapeutic evaluation. This study reports on the development of a near-infrared (NIR) fluorescent probe, designated DRP-O, for the selective detection of ONOO- with high sensitivity and photostability. DRP-O exhibits rapid response kinetics (within 2 min) and an impressive detection limit of 2.3 nM, enabling real-time monitoring of ONOO- dynamics in living cells. Notably, DRP-O demonstrates excellent photostability under continuous laser irradiation, ensuring reliable long-term monitoring in complex biological systems. We apply DRP-O to visualize endogenous ONOO- in living cells, demonstrating its potential for diagnosing and monitoring NAFLD-related oxidative stress. Furthermore, DRP-O effectively evaluates the efficacy of therapeutic drugs in NAFLD cell models, underscoring its potential utility in drug screening studies. Moreover, we confirm DRP-O to enable selective identification of fatty liver tissues in a mouse model of NAFLD, indicating its potential for the early diagnosis of NAFLD. Collectively, DRP-O represents a valuable tool for studying ONOO- dynamics, evaluating drug efficacy, and diagnosing NAFLD, offering insights into novel therapeutic strategies for this prevalent liver disorder.

8.
Sensors (Basel) ; 24(17)2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39275419

RESUMEN

Photodetectors converting light into electrical signals are crucial in various applications. The pursuit of high-performance photodetectors with high sensitivity and broad spectral range simultaneously has always been challenging in conventional semiconductor materials. Graphene, with its zero bandgap and high electron mobility, is an attractive candidate, but its low light absorption coefficient restricts its practical application in light detection. Integrating graphene with light-absorbing materials like PbS quantum dots (QDs) can potentially enhance its photodetection capabilities. Here, this work presents a broadband photodetector with enhanced sensitivity based on a graphene-PbS QD heterostructure. The device leverages the high carrier mobility of graphene and the strong light absorption of PbS QDs, achieving a wide detection range from ultraviolet to near-infrared. Employing a simple spinning method, the heterostructure demonstrates ultrahigh responsivity up to the order of 107 A/W and a specific detectivity on the order of 1013 Jones, showcasing significant potential for photoelectric applications.

9.
Sensors (Basel) ; 24(17)2024 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-39275735

RESUMEN

Raman spectroscopy with the advantages of the in situ and simultaneous detection of multi-components has been widely used in the identification and quantitative detection of gas. As a type of scattering spectroscopy, the detection sensitivity of Raman spectroscopy is relatively lower, mainly due to the low signal collection efficiency. This paper presents the design and assembly of a multi-channel cavity-enhanced Raman spectroscopy system, optimizing the structure of the sample pool to reduce the loss of the laser and increase the excitation intensity of the Raman signals. Moreover, three channels are used to collect Raman signals to increase the signal collection efficiency for improving the detection sensitivity. The results showed that the limits of detection for the CH4, H2, CO2, O2, and N2 gases were calculated to be 3.1, 34.9, 17.9, 27, and 35.2 ppm, respectively. The established calibration curves showed that the correlation coefficients were all greater than 0.999, indicating an excellent linear correlation and high level of reliability. Meanwhile, under long-time integration detection, the Raman signals of CH4, H2, and CO2 could be clearly distinguished at the concentrations of 10, 10, and 50 ppm, respectively. The results indicated that the designed Raman system possesses broad application prospects in complex field environments.

10.
Clin Exp Pharmacol Physiol ; 51(11): e13919, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39278645

RESUMEN

High-sensitivity C-reactive protein (hsCRP) to high-density lipoprotein cholesterol (HDL-C) ratio (CHR) is associated with coronary artery disease (CAD), but its predictive value for long-term adverse outcomes in patients with CAD following percutaneous coronary intervention (PCI) remains unexplored and is the subject of this study. Patients with CAD who underwent PCI at the Korea University Guro Hospital-Percutaneous Coronary Intervention (KUGH-PCI) Registry since 2004 were included. Patients were categorized into tertiles according to their CHR. The end points were all-cause mortality (ACM), cardiac mortality (CM) and major adverse cardiac events (MACEs). Kaplan-Meier analysis, multivariate Cox regression, restricted cubic spline (RCS) and sensitivity analyses were performed. A total of 3260 patients were included and divided into Group 1 (CHR <0.830, N = 1089), Group 2 (CHR = 0.830-3.782, N = 1085) and Group 3 (CHR >3.782, N = 1086). Higher CHR tertiles were associated with progressively greater risks of ACM, CM and MACEs (log-rank, p < 0.001). Multivariate Cox regression showed that patients in the highest tertile had greater risks of ACM (HR: 2.127 [1.452-3.117]), CM (HR: 3.575 [1.938-6.593]) and MACEs (HR: 1.337 [1.089-1.641]) than those in the lowest tertile. RCS analyses did not reveal a significant non-linear relationship between CHR and ACM, CM or MACEs. The significant associations remained significant in the sensitivity analyses, RCS analyses with or without extreme values, subgroup analyses and multiple imputations for missing data. Elevated CHR is a novel, independent risk factor for long-term ACM, CM and MACEs in CAD patients following PCI.


Asunto(s)
Proteína C-Reactiva , HDL-Colesterol , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Masculino , Femenino , Proteína C-Reactiva/análisis , Proteína C-Reactiva/metabolismo , Estudios Prospectivos , Persona de Mediana Edad , HDL-Colesterol/sangre , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/mortalidad , Anciano , Resultado del Tratamiento , Valor Predictivo de las Pruebas , Factores de Riesgo
11.
J Clin Lipidol ; 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-39278780

RESUMEN

BACKGROUND: To evaluate the relationships between residual inflammatory risk [assessed by high-sensitivity C-reactive protein (hsCRP)], residual cholesterol risk [assessed by low-density lipoprotein cholesterol (LDL-C)] and clinical outcomes among patients who underwent percutaneous coronary intervention (PCI) for in-stent restenosis (ISR) lesions. METHODS: Between January 2017 and December 2018, a total of 2079 patients who underwent PCI for ISR were consecutively enrolled. The primary outcome was the rate of major adverse cardiac events (MACE), defined as a composite endpoint of all-cause death, spontaneous myocardial infarction (MI), or repeat revascularization. RESULTS: During a median follow-up of 36 months, 436 MACEs occurred. Baseline hsCRP was significantly associated with MACE (highest versus lowest quartile, adjusted hazard ratio [aHR] 1.90 [95 % CI, 1.39-2.59]; P < 0.001). By contrast, the baseline LDL-C quartile was not associated with MACE (highest versus lowest quartile, aHR 0.93 [95 % CI, 0.71- 1.22]; P = 0.59). Compared with patients without residual risk (hsCRP <2 mg/L and LDL-C < 70 mg/dL), participants with both residual inflammatory and LDL-C risk (hsCRP ≥2 mg/L and LDL-C ≥ 70 mg/dL) (aHR, 1.39 [95 % CI, 1.06-1.83]; P = 0.02) and those with residual inflammatory risk only (hsCRP ≥2 mg/L and LDL-C < 70 mg/dL) (aHR, 1.34 [95 % CI, 1.01-1.72]; P = 0.04) had significantly higher risks of MACE. CONCLUSIONS: In the current cohort of patients after ISR PCI, inflammation assessed by hsCRP predicted higher risk of adverse clinical outcomes, whereas the level of LDL-C was not associated with adverse prognosis.

12.
Curr Med Res Opin ; : 1-11, 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39235073

RESUMEN

BACKGROUND: High-sensitivity cardiac troponins (Hs-cTns) are reliable indicators of myocardial injury, but their relationship with cardiovascular outcomes remains less understood. This study explores the association between adverse cardiac events and Hs-cTnT levels exceeding 14 ng/L in patients with stable CAD. METHODS: Thirteen pertinent studies were identified using specific keywords from a pool of 208 articles retrieved from PubMed, Scopus, and Google Scholar, spanning 2013 to 2023. The primary outcomes included all-cause mortality (ACM), myocardial infarction (MI), cardiovascular death (CVD), rehospitalization due to decompensated heart failure (RDHF), need for revascularization, and stroke. Comprehensive meta-analysis (CMA) was employed to analyze the data for odds ratios (OR) and 95% confidence intervals (CI). Heterogeneity was assessed using I2 statistics, and both qualitative assessment (Newcastle-Ottawa Scale) and quantitative analysis (Egger's and Beggs test, funnel plots) were conducted. RESULTS: The analysis included 29,115 participants (74.72% male) with a mean age of 68.34 years. It revealed a significantly elevated risk of ACM among stable CAD patients with Hs-cTnT levels >14 ng/L compared to those with levels <14 ng/L (11.2% vs. 3.3%; OR = 5.46; 95% CI = 1.53-19.54; p = 0.009). Similarly, higher risks were observed for MI (10.9% vs 3.6%; OR = 3.12; 95% CI = 0.98-9.95, p = 0.053), CVD (8.1% vs. 2.1%; OR = 3.37; 95% CI = 1.74-6.50; p < 0.0001), and RDHF (6.62% vs. 0.92%; OR = 9.46; 95% CI = 4.65-19.24; p < 0.0001). Notably, major adverse cardiovascular events (MACE) exhibited a stronger association with Hs-cTnT levels (18.2% vs 7.81%; OR = 1.89; 95% CI = 0.80-4.43; I2 = 97%; p = 0.14) compared to Hs-cTnI levels (20.1% vs 21.1%; OR = 1.30; 95% CI = 1.03-1.64; I2 <0.0001%; p = 0.03). CONCLUSION: Elevated levels of Hs-cTnT (>14 ng/L) are significantly associated with increased risks of RDHF and ACM in patients with stable CAD. Further large-scale prospective studies are warranted to refine risk assessment strategies and mitigate cardiovascular mortality in this population.

13.
Clin Appl Thromb Hemost ; 30: 10760296241280711, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39246223

RESUMEN

BACKGROUND: Recently, the effect of Lipoprotein(a) [Lp(a)] on thrombogenesis has aroused great interest, while inflammation has been reported to modify the Lp(a)-associated risks through an unidentified mechanism. PURPOSE: This study aimed to evaluate the association between platelet reactivity with Lp(a) and high-sensitivity C-reactive protein (hs-CRP) levels in percutaneous intervention (PCI) patients treated with clopidogrel. METHODS: Data were collected from 10,724 consecutive PCI patients throughout the year 2013 in Fuwai Hospital. High on-treatment platelet reactivity (HTPR) and low on-treatment platelet reactivity (LTPR) were defined as thrombelastography (TEG) maximum amplitude of adenosine diphosphate-induced platelet (MAADP) > 47 mm and < 31 mm, respectively. RESULTS: 6615 patients with TEG results were finally enrolled. The mean age was 58.24 ± 10.28 years and 5131 (77.6%) were male. Multivariable logistic regression showed that taking Lp(a) < 30 mg/dL and hs-CRP < 2 mg/L as the reference, isolated Lp(a) elevation [Lp(a) ≥ 30 mg/dL and hs-CRP < 2 mg/L] was not significantly associated with HTPR (P = 0.153) or LTPR (P = 0.312). However, the joint elevation of Lp(a) and hs-CRP [Lp(a) ≥ 30 mg/dL and hs-CRP ≥ 2 mg/L] exhibited enhanced association with both HTPR (OR:1.976, 95% CI 1.677-2.329) and LTPR (OR:0.533, 95% CI 0.454-0.627). CONCLUSIONS: The isolated elevation of Lp(a) level was not an independent indicator for platelet reactivity, yet the concomitant elevation of Lp(a) and hs-CRP levels was significantly associated with increased platelet reactivity. Whether intensified antiplatelet therapy or anti-inflammatory strategies could mitigate the risks in patients presenting combined Lp(a) and hs-CRP elevation requires future investigation.


Asunto(s)
Proteína C-Reactiva , Clopidogrel , Lipoproteína(a) , Intervención Coronaria Percutánea , Humanos , Masculino , Clopidogrel/farmacología , Clopidogrel/uso terapéutico , Proteína C-Reactiva/análisis , Proteína C-Reactiva/metabolismo , Lipoproteína(a)/sangre , Femenino , Persona de Mediana Edad , Intervención Coronaria Percutánea/métodos , Anciano , Ticlopidina/análogos & derivados , Ticlopidina/farmacología , Ticlopidina/uso terapéutico , Inhibidores de Agregación Plaquetaria/farmacología , Inhibidores de Agregación Plaquetaria/uso terapéutico , Plaquetas/metabolismo , Plaquetas/efectos de los fármacos
14.
Artículo en Inglés | MEDLINE | ID: mdl-39276070

RESUMEN

Holographic data storage technology is a cost-effective solution for long-term archival data storage. However, the development of suitable holographic recording materials remains a challenge. Among these materials, phenanthraquinone-doped poly(methyl methacrylate) (PQ/PMMA) stands out due to its low cost and controllable thickness. Nevertheless, its limited photosensitivity and diffraction efficiency hinder its widespread application. In order to solve these problems, we put forward a kind of convenient and simple, low cost strategy, by adding plasticizer N,N-dimethylformamide (DMF) for preparation of DMF-PQ/PMMA photopolymer, avoid the use of complex compounds. The addition of DMF not only influences the thermal polymerization stage but also forms weak interactions with PQ during the photoreaction process, thereby enhancing the holographic performance of DMF-PQ/PMMA. Consequently, we achieved a remarkable 9.1-fold increase in photosensitivity (from ∼0.35 to 3.18 cm J-1), improved diffraction efficiency by 20% (from 65% to 80%), and reduced volume shrinkage by a factor of 8 (from 0.4% to 0.05%). Furthermore, utilizing a collinear holographic storage system with multiplexing shift at a scale of 5 µm resulted in an impressively low minimum bit error rate (BER) of only 0.36% (with an average BER of 1.4%), highlighting the fast processing capability and potential for low BER applications in holographic information storage using DMF-PQ/PMMA.

15.
BMC Geriatr ; 24(1): 756, 2024 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-39266972

RESUMEN

BACKGROUND: A decline in cognitive function is associated with inflammatory processes. However, the association between high-sensitivity C-reactive protein (hs-CRP) levels and cognitive decline in the Japanese population remains inconclusive. Thus, this study aimed to determine whether hs-CRP is associated with low cognitive function in 70- and 80-year-old community-dwelling Japanese individuals. METHODS: The participants in this cross-sectional study were 872 Japanese residents aged 70 and 80 years who voluntarily participated in the Septuagenarians, Octogenarians, Nonagenarians Investigation with Centenarians (SONIC) study between 2010 and 2011. Blood sample collection, cognitive assessment, and other measurements were performed at the venue. Low cognitive function was defined as a score of 25 points or lower on the Japanese version of the Montreal Cognitive Assessment. The odds ratio (OR) and 95% confidence interval (95% CI) for each hs-CRP quartile were calculated using logistic regression analysis. RESULTS: A total of 288 (69.9%) parsons in the 70-year-old group and 372 (80.9%) in the 80-year-old group exhibited low cognitive function. The association between hs-CRP levels and low cognitive function was significant among 70- and 80-year-old Japanese community-dwelling adults. In particular, the fourth quartile of hs-CRP (0.727-7.420 mg/L) in the 70-year-old group and the second and fourth quartiles (0.214-0.404 and 0.911-9.890 mg/L) in the 80-year-old group were associated with low cognitive function. Furthermore, the third quartile (0.409-0.892 mg/L) in the 80-year-old group was closely associated with low cognitive function. CONCLUSIONS: High hs-CRP levels were associated with lower cognitive function in 70- and 80-year-old Japanese community-dwelling individuals, suggesting that high hs-CRP levels may influence cognitive function.


Asunto(s)
Proteína C-Reactiva , Cognición , Disfunción Cognitiva , Vida Independiente , Humanos , Estudios Transversales , Anciano , Anciano de 80 o más Años , Masculino , Proteína C-Reactiva/análisis , Proteína C-Reactiva/metabolismo , Femenino , Japón/epidemiología , Cognición/fisiología , Disfunción Cognitiva/sangre , Disfunción Cognitiva/diagnóstico , Disfunción Cognitiva/epidemiología , Biomarcadores/sangre
16.
Clin Chem Lab Med ; 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39239902

RESUMEN

OBJECTIVES: The objective of this study is to evaluate the analytical and diagnostic performance of a high-sensitivity point-of-care (POC) cardiac troponin I assay, the Quidel TriageTrue™ (QuidelOrtho Inc, San Diego, USA), compared to central laboratory testing (CLT) in accelerated diagnostic protocols (ADP) in real time in a clinical environment. METHODS: In a nested sub-study of a pragmatic randomised control trial, consecutive patients with suspected acute coronary syndrome (ACS) and chest pain <12 h duration were randomised to the ESC 0/1 and 0/3-h ADP. Subjects underwent sampling for Quidel TriageTrue POC hs-TnI whole blood and plasma, CLT hs-TnT Roche Elecsys and a validated, NICE approved CLT High sensitivity cardiac troponin I (hs-TnI) (Siemens Attellica) at each time point. Assay imprecision was assessed by repeat analysis of whole blood samples at three levels (low, near 10 % CV 5-10 ng/L, medium, approximating 99th percentile 15-25 ng/L and high, 3-5 times the 99th percentile, 60-100 ng/L). Final diagnosis was adjudicated at 6 weeks by Roche hs-TnT using the 4th universal definition of myocardial infarction (MI). RESULTS: A total of 1,157 patients consented and had both investigational POC whole blood and plasma and central lab hs-cTn available. The median age was 59, 47.2 % were female and 15 % had suffered a previous MI. Assay imprecision of whole blood POC TriageTrue revealed 10 % CV at 8.6 ng/L (>50 % lower than 99th percentile [20.5 ng/L]) and a 20 % CV at 1.2 ng/L. Receiver operator characteristics (ROC) curves were computed for each assay against adjudicated index type 1 MI to study clinical performance. At all-time points there were excellent performance for whole blood POC TriageTrue: area under the curve (AUC) 0.97 [95 % CI 0.94-098], 0.98 [95 % CI 0.97-1.00] and 0.95 [95 % CI 0.92-0.98] at time 0, 1 and 3 h respectively. There was statistical equivalence for performance of whole blood and plasma POC TriageTrue hs-TnI and laboratory Siemens Atellica hs-TnI. CONCLUSIONS: The whole blood POC TriageTrue hs-TnI assay demonstrates imprecision levels consistent with high sensitivity characteristics and has a clinical performance equivalent to an established, validated and NICE approved laboratory Siemens Atellica hs-TnI.

17.
Heliyon ; 10(17): e36998, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-39296015

RESUMEN

We introduce NMR-Onion, an open-source, computationally efficient algorithm based on Python and PyTorch, designed to facilitate the automatic deconvolution of 1D NMR spectra. NMR-Onion features two innovative time-domain models capable of handling asymmetric non-Lorentzian line shapes. Its core components for resolution-enhanced peak detection and digital filtering of user-specified key regions ensure precise peak prediction and efficient computation. The NMR-Onion framework includes three built-in statistical models, with automatic selection via the BIC criterion. Additionally, NMR-Onion assesses the repeatability of results by evaluating post-modeling uncertainty. Using the NMR-Onion algorithm helps to minimize excessive peak detection.

19.
Carbohydr Polym ; 344: 122472, 2024 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-39218567

RESUMEN

Soft ionic conductors are widely used in flexible electronics. However, the simultaneous enhancement of their mechanical properties and ionic conductivity remains challenging. This paper reports the successful development of a strong and tough cellulose-based ionic conductor with exceptional mechanical properties and high ionic conductivity by in situ dissolution and reorganization of the fiber matrix of filter paper to create a multiscale structure. The resulting ionic conductor exhibits a fracture strength of 14.13 MPa and a fracture energy of up to 2.84 MJ/m3, exceeding most reported ionic conductors. It also exhibits an impressive ionic conductivity of up to 76.3 mS/cm. Results of experiments on its use in a flexible quasi-solid-state zinc-hybrid supercapacitor show its remarkable features, such as a high capacity of 218 mAh/g, an energy density of 217 Wh/kg, and a power density of 17,520 W/kg. Furthermore, it exhibits excellent temperature resistance, working effectively even at -60 °C. In addition, by incorporating kirigami structures, we fabricated a strain sensor with the cellulose-based ionic conductor with a high gauge factor, as well as a piezoresistive sensor for handwriting recognition and a capacitance pressure sensor for force mapping with wide range and sensitivity. This study opens up new possibilities for fabricating flexible electronics with superior performance using sustainable and renewable resources.

20.
Cureus ; 16(7): e65049, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39165461

RESUMEN

INTRODUCTION: Oxytocin is a uterotonic drug that acts on receptors in the myometrium, causing uterine contractions. However, oxytocin receptors are also present in other organs, including the myocardium. Heat-stable carbetocin, a long-acting analog of oxytocin, is also known to act on these oxytocin receptors. As carbetocin has a long half-life of 40 minutes, its duration of action on the myocardium may be relatively longer than that of oxytocin. Therefore, this study aimed to study the cardiovascular effects of using a lower dose of carbetocin (50 mcg) compared to the standard dose (100 mcg) during elective cesarean delivery. MATERIALS AND METHODS: A total of 212 full-term pregnant women were randomized into two groups: group I received 50 mcg of intravenous carbetocin, and group II received 100 mcg of intravenous carbetocin. Heart rate, blood pressure (BP), oxygen saturation, electrocardiogram changes, and pre- and postoperative (12 hours after cesarean delivery) high-sensitivity cardiac troponin I levels were compared between the groups. RESULTS: No statistically significant differences were observed between the groups with respect to heart rate, BP, electrocardiogram changes, or difference in pre- and postoperative high-sensitivity cardiac troponin I levels (p > 0.05). CONCLUSION: Carbetocin's cardiovascular effects were similar in both groups. None of the participants had adverse cardiovascular effects from the drug, and there were no differences in cardiovascular effects between the groups.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA