Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros











Intervalo de año de publicación
1.
Int Ophthalmol ; 44(1): 405, 2024 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-39392516

RESUMEN

PURPOSE: The interplay between myopia and glaucoma has gained attention, with escalating myopia demonstrating a significant association with increased POAG rates, particularly in patients with severe myopia. This systematic review aimed to comprehensively analyze the relationship between myopia and glaucoma, focusing on the structural and functional implications, risk factors, and assessment modalities. Optical coherence tomography (OCT) played a crucial role in this study, particularly in highly myopic populations. METHODS: This study's rigor is underscored by using the PRISMA guidelines, which ensured a meticulous search strategy was employed across multiple databases from 2012 to 2024. The inclusion criteria included individuals aged 18 years or older with high myopia, defined as a spherical equivalent of less than -6.0 diopters or an axial length > 26.0 mm, diagnosed with chronic glaucoma. Various study designs were incorporated, including randomized controlled trials, prospective cohort studies, and observational studies. Quality assessment was performed using the Jadad Scale, and statistical analyses were performed to summarize the study characteristics and outcomes. RESULTS: Of the 350 initial articles, 15 met the inclusion criteria. OCT assessments revealed structural changes such as thinning of the retinal nerve fiber layer preceding functional losses. Meta-analyses demonstrated a heightened risk of POAG with increasing myopia severity, showing a significant nonlinear relationship. This meta-analysis of six studies involving 3040 patients revealed a relationship between myopia and glaucoma (OR = 12.0, 95% CI 10.1-4.7, P < 0.00001). CONCLUSION: This comprehensive analysis consolidates the evidence of the relationship between myopia and glaucoma, emphasizing the pivotal role of OCT and other imaging modalities in early detection and monitoring.


Glaucoma is a significant cause of permanent blindness worldwide. This causes damage to the visual nerve that worsens over time. The primary way to treat open-angle glaucoma and its many causes is to lower eye pressure. Further research is being conducted to determine the relationship between nearsightedness and glaucoma. Increased nearsightedness is significantly linked to higher rates of glaucoma, especially in people with severe nearsightedness. This review aimed to examine the link between myopia and glaucoma in greater depth, focusing on structural and functional effects, risk factors, and assessment methods, especially optical coherence tomography (OCT), in very nearsighted people. We conducted a thorough search of several databases between 2012 and 2024. Individuals aged 18 years or older with myopia greater than six diopters or an axial length greater than 26 mm and a diagnosis of chronic glaucoma were eligible. Randomized controlled trials, prospective cohort studies, and observational studies were some of the methods used in this study. The quality of the work and statistical methods were used to summarize the features and results of the study. Of the 350 articles initially published, only 15 met the inclusion criteria. These studies mostly used different optical tomography tests to detect structural changes, such as ocular nerve fiber layer damage, before functional loss. According to meta-analyses, the risk of chronic glaucoma increases as myopia worsens, indicating a solid nonlinear relationship. Myopia and glaucoma are linked, demonstrating the importance of thorough evaluation. Severe myopia is strongly associated with damage to the visual nerve. Over the past few years, optical tomography has become a vital imaging tool for identifying early damage to the optic nerve. However, further research is needed on the sex-related tendencies of glaucoma patients. This study provides data that reveal a link between nearsightedness and glaucoma, highlighting the importance of optical tomography and other imaging techniques for early detection and monitoring. To better manage glaucoma in highly myopic individuals, we need to understand how the severity of myopia, changes in structure, and changes in function affect each other.


Asunto(s)
Glaucoma , Miopía , Células Ganglionares de la Retina , Tomografía de Coherencia Óptica , Humanos , Glaucoma/fisiopatología , Glaucoma/diagnóstico , Glaucoma/complicaciones , Presión Intraocular/fisiología , Miopía/diagnóstico , Miopía/fisiopatología , Miopía/complicaciones , Fibras Nerviosas/patología , Disco Óptico/diagnóstico por imagen , Disco Óptico/patología , Células Ganglionares de la Retina/patología , Factores de Riesgo , Tomografía de Coherencia Óptica/métodos , Campos Visuales/fisiología
2.
Int J Retina Vitreous ; 10(1): 58, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39180080

RESUMEN

PURPOSE: To verify the correlation between the full-macular and the ganglion cell complex (GCC) thickness measurements and retinal sensitivity (RS) assessed by microperimetry (MP) 6 months after surgical peeling for idiopathic epiretinal membrane (ERM). METHODS: Forty-three were submitted to pars-plana posterior vitrectomy (PPV) with concomitant peeling of internal limiting membrane (ILM) for idiopathic ERM treatment. Best-corrected visual acuity (BCVA) and 3D volumetric high-definition optical coherence tomography (OCT) imaging were preoperatively acquired. Six months after the surgery, BCVA, OCT imaging, and RS measured by MP were assessed. For the OCT parameters, we analyzed both the full-macular and the ganglion cell layer complex (GCC) thicknesses. The MP parameters tested were 44 points covering 20 central degrees (6 mm), with direct correspondence with the nine sectors of the OCT-ETDRS map. This approach enables the direct topographic correlation between the structure and functional measurements. The OCT and MP exam measurements were also performed in 43 eyes of age-matched healthy controls. Correlations between BCVA, RS, and OCT parameters were examined. RESULTS:  All patients exhibited a substantial improvement in visual acuity following surgery. The RS parameters were significantly lower in patients compared to the controls. The full-macular thickness measurements were thicker than controls preoperatively and significantly reduced postoperatively; however, remaining significantly higher than controls, in the 4 inner sectors, at the fovea and for the average macular thickness. Preoperative GCC measurements were higher than those in controls. There was a significant reduction in GCC thickness in all sectors postoperatively, especially in the outer sectors, as well as in the average macular thickness. A positive correlation was found between full-macular and GCC thickness and RS postoperatively in several sectors. CONCLUSIONS: Our results demonstrate that ERM peeling can improve visual acuity in the postoperative period. However, RS may not fully restore, remaining significantly lower when compared to the controls. Both full-macular and GCC thickness measurements were reduced 6 months after surgery. However, significant thinning of the GCC thickness was observed when compared to the normal control eyes, indicating the occurrence of some degree of ganglion cell layer atrophy. We have demonstrated significant correlations among various OCT thickness parameters, particularly for GCC measurements. We believe that GCC integrity may play an important role in visual function after ERM surgery, and that MP may help better understand the correlations between structural and functional findings following ERM surgery.

3.
Cir Cir ; 92(3): 324-330, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38862104

RESUMEN

OBJECTIVE: The objective of the study is to compare the optic coherence tomography (OCT) parameters of the healthy and affected sides of patients with idiopathic sudden sensorineural hearing loss (ISSNHL) and to investigate the relationships between these and the improvement in hearing levels. METHODS: A bilateral eye evaluation of patients diagnosed with ISSNHL was performed with OCT. The ganglion cell complex (GCC) and retina nerve fiber layer (RNFL) thickness values were recorded and the differences between the two eyes were examined. RESULTS: An evaluation was made of 39 patients with a mean age of 44.82 ± 14.90 years. The RNFL thickness of the eyes was determined to be mean 89.87 ± 3.65 µm on the affected side and 103.87 ± 3.98 µm on the healthy control side (p = 0.0001). The mean GCC was determined to be mean 90.46 ± 3.49 µm on the affected side and 103.77 ± 3.96 µm on the healthy control side (p = 0.0001). CONCLUSIONS: A statistically significant difference was observed between the healthy and affected eyes of patients with ISSNHL with respect to mean GCC and mean RNFL thickness. OCT could be a useful technique for measuring this neural degeneration.


OBJETIVO: Comparar e investigar los parámetros de la tomografía de coherencia óptica (OCT) de los lados sanos y afectados de pacientes con pérdida auditiva neurosensorial súbita idiopática (PANSI). MÉTODO: La evaluación ocular bilateral de los pacientes diagnosticados con PANSI se realizó con OCT. Se registraron los valores de espesor del complejo de células ganglionares (CCG) y de la capa de fibras nerviosas de la retina (CFNR), y se examinaron las diferencias entre los dos ojos. RESULTADOS: Se evaluaron 39 pacientes, con una edad media de 44.82 ± 14.90 años. Se determinó que el grosor de la CFNR de los ojos era una media de 89.87 ± 3.65 µm en el lado afectado y 103.87 ± 3.98 µm en el lado de control sano (p = 0.0001). Se determinó que el CCG medio era 90.46 ± 3.49 µm en el lado afectado y 103.77 ± 3.96 µm en el lado de control sano (p = 0.0001). CONCLUSIONES: Se encontró una diferencia estadísticamente significativa entre los ojos sanos y afectados de pacientes con PANSI con respecto al CCG medio y al espesor medio de la CFNR. La OCT podría ser una técnica útil para medir esta degeneración neuronal.


Asunto(s)
Axones , Fibras Nerviosas , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Adulto , Femenino , Masculino , Fibras Nerviosas/patología , Persona de Mediana Edad , Axones/patología , Células Ganglionares de la Retina/patología , Pérdida Auditiva Sensorineural/diagnóstico por imagen , Pérdida Auditiva Súbita/diagnóstico por imagen , Adulto Joven
4.
Front Neuroimaging ; 3: 1340754, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38496013

RESUMEN

Introduction: Parkinson's disease (PD) presents challenges in early diagnosis and follow-up due to the lack of characteristic findings. Recent studies suggest retinal changes in PD are possibly indicative of neurodegeneration. We explored these changes using optical coherence tomography (OCT) to assess retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) thickness. Methods: Thirty PD and non-PD patients were matched according to demographic characteristics and OCT and clinical evaluations to rule out other neurodegenerative and visual diseases. Results: We observed a significant thinning of the RNFL in patients diagnosed with PD compared to non-PD patients (p = 0.015). Additionally, this reduction in RNFL thickness was found to correlate with the severity of the disease (p = 0.04). Conclusion: The OCT serves as a tool for quantifying neurodegeneration in PD, showing a significant correlation with disease severity. These findings suggest that OCT could play a crucial role as a potential biomarker in the diagnosis and monitoring of PD.

5.
Front Integr Neurosci ; 16: 1034705, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36506477

RESUMEN

The study aimed to evaluate the retinal ganglion cell structure using optical coherence tomography and the visual pathway function employing visual evoked potentials in the diagnosis and monitoring of patients with pituitary macroadenoma. A descriptive, cross-sectional, and longitudinal study (3 and 12 months follow-up) was conducted on forty-two patients. Thirty-five age-matched healthy controls were used in the cross-sectional one. Full neuro-ophthalmological evaluation (structural and functional) was carried out including global and segmented retinal nerve fiber layer/ganglion cell complex analysis and amplitude and latency of P100 component in the electrophysiology. Statistical data analysis was conducted with R version 3.6.3 and Python version 3.8. Associations were evaluated using Spearman's correlations. Amplitude sensitivities were 0.999, and bi-nasal sectors of ganglion cell complex thickness specificities were 0.999. This structural parameter had the highest diagnostic value (area under curve = 0.923). Significant associations were found between bi-nasal sectors with amplitude at 12' (rho > 0.7, p < 0.01) and median deviation of the visual field (rho > 0.5, p < 0.01) at 3 months. Pre-surgical values of bi-nasal sectors and amplitude can predict post-surgically median deviation and amplitude (Oz, 12') at 3 months with r 2 > 0.5. Bi-nasal sectors of ganglion cell complex and visual evoked potentials P100 amplitude are efficient biomarkers of visual pathway damage for pituitary macroadenoma patients' management. Pre-surgical values of the bi-nasal sector and visual evoked potentials' amplitude could help to predict the restoration of parvocellular pathway traffic after decompression.

6.
Arq. bras. oftalmol ; Arq. bras. oftalmol;85(4): 333-338, July-Aug. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1383833

RESUMEN

ABSTRACT Purpose: To investigate inter-eye retinal vessel density and thickness asymmetry in unilateral pseudoexfoliation syndrome and understand its use for the early detection of glaucoma. Methods: Thirty patients with unilateral pseudoexfoliation syndrome were enrolled in our study. Optical coherence tomography angiography macular scans were used measure the retinal vessel density, and optical coherence tomography scans were used to assess the thickness parameters of the peripapillary retinal nerve fiber layer and the macular ganglion cell complex. Inter-eye asymmetry was determined by taking the absolute value of the difference in the vessel density and thickness parameters between the pseudoexfoliation syndrome eye and fellow eye. Results: The mean patient age was 64.20 ± 7.05 y in the study group. Inter-eye asymmetry in the peripapillary retinal nerve fiber layer thickness and macular ganglion cell complex measurements were significant in the study group (p=0.03 and p=0.001, respectively). The vessel density of the macular superficial inner region was significantly lower in eyes with pseudoexfoliation syndrome than in fellow eyes (p=0.035). However, there was no inter-eye asymmetry in the central and full region macular superficial vessel density of eyes with pseudoexfoliation syndrome and fellow eyes (p>0.05). Conclusion: Retinal vessel density can be evaluated using optical coherence tomography angiography measurements. There was inter-eye asymmetry in the inner region macular superficial vessel density, peripapillary retinal nerve fiber layer, and macular ganglion cell complex thickness of the unilateral pseudoexfoliation syndrome eyes and fellow eyes. Further studies on a larger number of subjects might provide more clarity regarding the relationship between the inter-eye asymmetry of the retinal vessel density and thickness parameters with early detection of glaucomatous damage.


RESUMO Objetivo: Investigar a densidade dos vasos interoculares da retina e assimetria na espessura na síndrome de pseudoexfoliação unilateral e o seu uso para a detecção precoce de glaucoma. Métodos: Trinta pacientes com síndrome de pseudoexfoliação unilateral foram incluídos no estudo. As varreduras maculares de angiografia por tomografia de coerência óptica mediram a densidade dos vasos da retina, e as varreduras por tomografia de coerência óptica obtiveram parâmetros de espessura da camada de fibras nervosas da retina peripapilar e do complexo macular de célula ganglionar. A assimetria interocular foi determinada tomando o valor absoluto da diferença entre o olho da síndrome de pseudoexfoliação e o olho oposto nos parâmetros de densidade e espessura dos vasos. Resultados: A média de idade foi 64,20 ± 7,05 anos no grupo de estudo. A assimetria interocular na espessura da camada de fibra nervosa da retina peripapilar e as medidas do complexo macular de célula ganglionar foram estatisticamente significativas no grupo de estudo (p=0,03 e p=0,001, respectivamente). Para os olhos com síndrome de pseudoexfoliação, a densidade do vaso da região macular superficial interna foi significativamente menor do que em olhos opostos (p=0,035). No entanto, não houve assimetria interocular estatisticamente significativa na densidade macular dos vasos superficiais da região central e completa entre os olhos da síndrome de pseudoexfoliação e os olhos opostos (p>0,05). Conclusões: A densidade dos vasos da retina pode ser avaliada por medidas de angiografia por tomografia de coerência óptica. Houve assimetria interocular na densidade macular do vaso superficial da região interna, camada de fibra nervosa da retina peripapilar e espessura do complexo macular de célula ganglionar entre olhos com síndrome de pseudoexfoliação unilateral e olhos opostos. Novos estudos com um número maior de indivíduos podem fornecer a relação entre a assimetria interocular da densidade do vaso da retina e os parâmetros de espessura com detecção precoce de dano glaucomatoso.

7.
Arq. bras. oftalmol ; Arq. bras. oftalmol;83(5): 372-377, Sept.-Oct. 2020. tab
Artículo en Inglés | LILACS | ID: biblio-1131635

RESUMEN

ABSTRACT Purpose: To assess tomographic ganglion cell complex changes in patients with diabetic macular edema treated with intravitreal injections of anti-vascular endothelial growth factor (anti-VEGF). Methods: We analyzed data from 35 eyes of 35 previously untreated patients in whom diabetic macular edema improved after three loading doses of anti-VEGF injection and who did not receive repeated injections. We recorded spectral domain-optical coherence tomography assessments of ganglion cell complex and central macular thickness at baseline and monthly for three months, and on the sixth and ninth month after treatment. We compared the results with those of the unaffected eyes in the same patients and with those in a control group of patients with diabetic macular edema who were untreated. Results: The mean age of the patients in the treatment group was 60 ± 4.38 years. The foveal thicknesses measured using optical coherence tomography decreased significantly from baseline to the third month post-injection (p<0.05). The mean ganglion cell complex thickness was 115.08 ± 16.72 µm before the first injection and 101.05 ± 12.67 µm after the third injection (p<0.05). The mean ganglion cell complex was 110.04 ± 15.07 µm on the sixth month (p>0.05) and 113.12 ± 11.15 µm on the ninth month (p>0.05). We found a significant difference between the patients and the control group in terms of mean ganglion cell complex thickness on the second- and third-months post-injection (p<0.05). Conclusion: Our study showed that the ganglion cell complex thickness in patients with diabetic macular edema decreased after the anti-VEGF injections. We cannot ascertain whether the ganglion cell complex thickness decreases were due to effects of the anti-VEGF agents or to the natural disease course.


RESUMO Objetivo: Avaliar as alterações do complexo tomográfico das células ganglionares em pacientes com edema macular diabético tratados com injeções intravítreas do fator de crescimento endotelial anti-vascular (anti-VEGF). Métodos: Analisamos dados de 35 olhos de 35 pacientes previamente não tratados nos quais o edema macular diabético melhorou após três doses de injeção de anti-VEGF e que não receberam injeções repetidas. Registramos avaliações da tomografia de coerência óptica de domínio espectral do complexo de células ganglionares e da espessura macular central na linha de base e mensalmente por três meses e, também no sexto e nono mês após o tratamento. Comparamos os resultados com os olhos não afetados nos mesmos pacientes e com os de um grupo controle de pacientes com edema macular diabético que não foram tratados. Resultados: A média da idade dos pacientes no grupo de tratamento foi de 60 ± 4,38 anos. As espessuras foveais medidas pela tomografia de coerência óptica diminuiram significativamente desde o início até o terceiro mês após a injeção (p<0,05). A espessura média do complexo de células ganglionares foi de 115,08 ± 16,72 µm antes da primeira injeção e 101,05 ± 12,67 µm após a terceira injeção (p<0,05). A média do complexo de célula ganglionar foi de 110,04 ± 15,07 µm no sexto mês (p>0,05) e 113,12 ± 11,15 µm no nono mês (p>0,05). Encontramos uma diferença significativa entre os pacientes e o grupo controle quanto à média da espessura do complexo de células ganglionares no segundo e terceiro meses após a injeção (p<0,05). Conclusão: Nosso estudo mostrou que a espessura do complexo de células ganglionares em pacientes com edema macular diabético diminuiu após as injeções de anti-VEGF. Não podemos determinar se a diminuição da espessura do complexo de células ganglionares ocorreu devido aos efeitos dos agentes anti-VEGF ou ao curso natural da doença.


Asunto(s)
Humanos , Persona de Mediana Edad , Edema Macular , Inhibidores de la Angiogénesis , Factor A de Crecimiento Endotelial Vascular , Diabetes Mellitus , Retinopatía Diabética , Agudeza Visual , Edema Macular/tratamiento farmacológico , Edema Macular/diagnóstico por imagen , Resultado del Tratamiento , Inhibidores de la Angiogénesis/uso terapéutico , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Tomografía de Coherencia Óptica , Retinopatía Diabética/tratamiento farmacológico , Retinopatía Diabética/diagnóstico por imagen , Inyecciones Intravítreas , Bevacizumab/uso terapéutico
8.
Int Ophthalmol ; 35(1): 81-7, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25425106

RESUMEN

The purpose of the study was to correlate the Fourier-domain OCT ganglion cell complex (GCC) parameters with automated perimetry (AP) functional measures of the optic nerve. This retrospective study included patients who had previously undergone examination with the RTVue-100 OCT and AP, SITA strategy. The parameters of GCC (average, superior, inferior, S-I [superior inferior difference], S-I SD [standard deviation of S-I], GLV [global loss volume] and FLV [focal loss volume]) were correlated with the mean deviation (MD) and pattern standard deviation (PSD) values of AP using linear and logarithmic regression analysis. All correlations between GCC and automated perimetry parameters were strong (r > 0.60), except that for SI and MD (r = -0.05); SI and PSD (r = 0.09); SI-DS and MD (r = -0.06); and SI-SD and PSD (r = 0.08). In summary, GCC derived structural measures showed good correlation with functional parameters from AP.


Asunto(s)
Glaucoma/diagnóstico , Presión Intraocular , Fibras Nerviosas/patología , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/métodos , Femenino , Estudios de Seguimiento , Glaucoma/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Estudios Retrospectivos , Tonometría Ocular , Pruebas del Campo Visual , Campos Visuales
9.
Rev. Soc. Colomb. Oftalmol ; 48(4): 354-360, 2015. tab.
Artículo en Español | LILACS, COLNAL | ID: biblio-913401

RESUMEN

Objetivos: determinar el espesor del complejo ganglionar celular (CGC) mediante tomografía de coherencia óptica de dominio de Fourier (FD-OCT) en pacientes con diagnóstico de hipertensión ocular previa clasificación del riesgo de conversión a glaucoma utilizando la regla STAR (Scoring Tool For Assessing Risk). Materiales y Métodos: mediante la revisión de historias clínicas, se seleccionaron pacientes con diagnóstico previo de hipertensión ocular (HTO). A cada paciente se le realizó una valoración oftalmológica completa, medición del espesor del CGC mediante OCT y calculo del STAR. Los datos obtenidos se relacionaron con variables demográficas, presión intraocular, paquimetría central y perimetría computarizada. Resultados: se analizaron 106 ojos de 53 pacientes con HTO. La PIO promedio fue de 23.55 ± 0.69 mmHg. La regla STAR fue aplicada en 96 ojos. El 65.6% (63 ojos) se categorizó en alto riesgo de conversión a glaucoma en los próximos cinco años. Los pacientes de este grupo presentaron un espesor del CGC significativamente menor que el de los otros grupos. El valor promedio del espesor del complejo ganglionar superior e inferior fue de 83 ± 4.5 micras y 82.09 ± 4.98 micras respectivamente. Conclusión: los pacientes clasificados en el grupo de alto riesgo STAR tienen espesores del CGC significativamente menores. La disminución del espesor del CGC se correlacionó positivamente con las anormalidades registradas en la perimetría computarizada.


Objective: to determine the thickness of the ganglion cell complex (GCC) by Fourier domain optical coherence tomography (FDOCT) in patients diagnosed with ocular hypertension who were classified with the STAR rule (Scoring Tool for Assessing Risk) to determine the risk of conversion to glaucoma. Methods: patients with ocular hypertension previously diagnosed were selected from medical records. Each patient underwent a complete ophthalmic evaluation, measurement of the thickness of the CGC by FD-OCT (Nidek RS-3000) and calculation of the STAR. Data recorded was related to demographic variables, intraocular pressure, central corneal thickness and computerized perimetry. Results: 106 eyes of 53 patients with ocular hypertension were analyzed. The average intraocular presure was 23.55 ± 0.69 mmHg. The STAR rule was applied in 96 eyes. 65.6% (63 eyes) were categorized into high risk of conversion to glaucoma in the next five years. Patients in this group had a significantly lower thickness of the CGC than the other groups. The average value of the thickness of the upper and lower CGC was 83 ± 4.5 microns and 82.09 ± 4.98 microns respectively. Conclusion: patients classified in the STAR high risk group have a signifi cantly lower thickness of the CGC. The thinning of the CGC was positively correlated with abnormalities recorded in the computerized perimetry.


Asunto(s)
Hipertensión Ocular/diagnóstico por imagen , Paquimetría Corneal/estadística & datos numéricos , Glaucoma/terapia , Tomografía de Coherencia Óptica/estadística & datos numéricos
10.
Rev. Soc. Colomb. Oftalmol ; 48(1): 32-41, 2015. ilus. graf.
Artículo en Español | LILACS, COLNAL | ID: biblio-947027

RESUMEN

La evaluación de los discos ópticos en pacientes miopes suele ser problemática, razón por la cual muchas veces el apoyo en imágenes diagnósticas suele ser de gran ayuda. Se describirán algunos casos clínicos en los cuales la evaluación clínica no fue conclusiva, razón por la cual el apoyo en la tomografía óptica coherente fue determinante. El equipo RS-3000 Nidek ® usa una base normativa, realizada en pacientes miopes con longitudes axiales superiores a 26mm, los resultados suelen ser distintos especialmente en la evaluación del complejo celular ganglionar. Se describen dos casos clínicos en los cuales la evaluación mediante OCT fue de gran importancia.


The evaluation of optical discs in myopic patients is often problematic, this is why diagnostic imaging support is often helpful. In some clinical cases in which the clinical evaluation was inconclusive, the optical coherence tomography, was decisive. The RS-3000 Nidek ® equipment uses a normative database held in myopic patients with axial lengths between 26 to 29 mm, the OCT results are often different especially in the evaluation of ganglion cell complex. We describe two clinical cases in which the evaluation by OCT was of great importance.


Asunto(s)
Miopía/diagnóstico , Oftalmopatías/diagnóstico , Glaucoma/diagnóstico , Tomografía de Coherencia Óptica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA