Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
BMC Musculoskelet Disord ; 25(1): 123, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38336651

RESUMEN

BACKGROUND: The purpose of this study was to investigate the effects of four different doses of verapamil on the mechanical behaviors of solid and the characteristics of fluid flow in cancellous bone of distal femur of type 2 diabetes rats under dynamic external load. METHODS: Based on the micro-CT images, the finite element models of cancellous bones and fluids at distal femurs of rats in control group, diabetes group, treatment groups VER 4, VER 12, VER 24, and VER 48 (verapamil doses of 4, 12, 24, and 48 mg/kg/day, respectively) were constructed. A sinusoidal time-varying displacement load with an amplitude of 0.8 µm and a period of 1s was applied to the upper surface of the solid region. Then, fluid-solid coupling numerical simulation method was used to analyze the magnitudes and distributions of von Mises stress, flow velocity, and fluid shear stress of cancellous bone models in each group. RESULTS: The results for mean values of von Mises stress, flow velocity and FSS (t = 0.25s) were as follows: their values in control group were lower than those in diabetes group; the three parameters varied with the dose of verapamil; in the four treatment groups, the values of VER 48 group were the lowest, they were the closest to control group, and they were smaller than diabetes group. Among the four treatment groups, VER 48 group had the highest proportion of the nodes with FSS = 1-3 Pa on the surface of cancellous bone, and more areas in VER 48 group were subjected to fluid shear stress of 1-3 Pa for more than half of the time. CONCLUSION: It could be seen that among the four treatment groups, osteoblasts on the cancellous bone surface in the highest dose group (VER 48 group) were more easily activated by mechanical loading, and the treatment effect was the best. This study might help in understanding the mechanism of verapamil's effect on the bone of type 2 diabetes mellitus, and provide theoretical guidance for the selection of verapamil dose in the clinical treatment of type 2 diabetes mellitus.


Asunto(s)
Diabetes Mellitus Experimental , Diabetes Mellitus Tipo 2 , Ratas , Animales , Hueso Esponjoso/diagnóstico por imagen , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Verapamilo/farmacología , Diabetes Mellitus Experimental/tratamiento farmacológico , Simulación por Computador , Estrés Mecánico , Análisis de Elementos Finitos
2.
Comput Biol Med ; 163: 107144, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37315384

RESUMEN

BACKGROUND: Under external loading, the fluid shear stress (FSS) in the porous structures of bones, such as trabecular or lacunar-canalicular cavity, can influence the biological response of bone cells. However, few studies have considered both cavities. The present study investigated the characteristics of fluid flow at different scales in cancellous bone in rat femurs, as well as the effects of osteoporosis and loading frequency. METHODS: Sprague Dawley rats (3 months old) were divided into normal and osteoporotic groups. A multiscale 3D fluid-solid coupling finite element model considering trabecular system and lacunar-canalicular system was established. Cyclic displacement loadings with frequencies of 1, 2, and 4 Hz were applied. FINDINGS: Results showed that the wall FSS around the adhesion complexes of osteocyte on the canaliculi was higher than that on the osteocyte body. Under the same loading conditions, the wall FSS of the osteoporotic group was smaller than that of the normal group. The fluid velocity and FSS in trabecular pores exhibited a linear relationship with loading frequency. Similarly, the FSS around osteocytes also showed the loading frequency-dependent phenomenon. INTERPRETATION: The high cadence in movement can effectively increase the FSS level on osteocytes for osteoporotic bone, i.e., expand the space within the bone with physiological load. This study might help in understanding the process of bone remodeling under cyclic loading and provide the fundamental data for the development of strategies for osteoporosis treatment.


Asunto(s)
Remodelación Ósea , Hueso Esponjoso , Líquido Extracelular , Análisis Numérico Asistido por Computador , Osteocitos , Osteoporosis , Ratas Sprague-Dawley , Resistencia al Corte , Estrés Mecánico , Osteoporosis/fisiopatología , Hueso Esponjoso/fisiología , Osteocitos/fisiología , Femenino , Animales , Líquido Extracelular/fisiología , Imagenología Tridimensional , Ratas
3.
Adv Sci (Weinh) ; 9(28): e2202748, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35975421

RESUMEN

Evaluating the delamination process in the synthesis of MXenes (2D transition metal carbides and nitrides) is critical for their development and applications. However, the preparation of large defect-free MXene flakes with high yields is challenging. Here, a power-focused delamination (PFD) strategy is demonstrated that can enhance both the delamination efficiency and yield of large Ti3 C2 Tx MXene nanosheets through repetitive precipitation and vortex shaking processes. Following this protocol, a colloidal concentration of 20.4 mg mL-1 of the Ti3 C2 Tx MXene can be achieved after five PFD cycles, and the yield of the basal-plane-defect-free Ti3 C2 Tx nanosheets reaches 61.2%, which is 6.4-fold higher than that obtained using the sonication-exfoliation method. Both nanometer-thin devices and self-supporting films exhibit excellent electrical conductivities (≈25 000 and 8260 S cm-1 for a 1.8 nm thick monolayer and 11 µm thick film, respectively). Hydrodynamic simulations reveal that the PFD method can efficiently concentrate the shear stress on the surface of the unexfoliated material, leading to the exfoliation of the nanosheets. The PFD-synthesized large MXene nanosheets exhibit superior electrical conductivities and electromagnetic shielding (shielding effectiveness per unit volume: 35 419 dB cm2 g-1 ). Therefore, the PFD strategy provides an efficient route for the preparation of high-performance single-layer MXene nanosheets with large areas and high yields.

4.
J Biomech ; 109: 109912, 2020 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-32807313

RESUMEN

The structure of a bone tissue is capable of adapting to mechanical loading through the process of bone remodeling, which is regulated by osteoblasts and osteoclasts. Fluid flow within trabecular porosity under cyclic loading is one of the factors stimulating the biological response of osteoblasts and osteoclasts. However, the relation between loading directions and interstitial fluid flow was seldom studied. In the present study, a finite element model based on micro-computed tomographic reconstructions is built by using a mouse femur. Results from the fluid-solid coupling numerical simulation indicate that the loading in different directions generates a distinct distribution of von Mises stress in the bone matrix and a fluid shear stress (FSS) in the bone marrow. The loading along the physiological direction leads to a more uniform distribution of solid stress and produces an FSS level beneficial to the biological response of osteoblasts and osteoclasts compared with those along the non-physiological direction. There was a minimum threshold line of wall FSS with a specific solid stress at the bone surface, suggesting that the wall FSS is mainly induced by the solid strain. These results may offer fundamental data in understanding the mechanical environment around osteoblasts and osteoclasts and the cellular and molecular mechanisms of mechanical loading-induced bone remodeling.


Asunto(s)
Remodelación Ósea , Hueso Esponjoso , Hueso Esponjoso/diagnóstico por imagen , Simulación por Computador , Osteoclastos , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA