1.
Artículo en Inglés | MEDLINE | ID: mdl-39289175

RESUMEN

Owing to its low incidence, small trauma, fast recovery, and high efficiency, left atrial appendage occlusion has become a new strategy for preventing stroke caused by atrial fibrillation. Due to a lack of relevant research information on this emerging technology, the effectiveness, stability, or related complications of occluders are mostly observed from a clinical perspective. However, there are fewer studies on the mechanical properties and safety of these occluders. In this study, a new left atrial appendage occluder is proposed, and a complete numerical simulation analysis framework is established through the finite element method to simulate the actual implantation and service process of the left atrial appendage occluder. Besides, the influence of the structural size and release scale of the occluder on its support performance, occluding effect, and safety is also explored. The results demonstrate that the structural size and release scale exert a significant impact on the support performance, occluding effect, and safety of the occluder. The structural optimization of the occluder contributes to enhancing its mechanical performance, thus ensuring its stability and effectiveness after implantation. Overall, these efforts may lay a scientific foundation for the structural optimization, safety evaluation, and effectiveness prediction of the occluder. Furthermore, these findings also provide effective reference for the application of numerical simulation technology in the research on the left atrial appendage occlusion.

2.
Ann Biomed Eng ; 2024 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-39230788

RESUMEN

PURPOSE: Ultrasound imaging is key in the management of patients with an abdominal aortic aneurysm (AAA). It was recently shown that the cyclic diameter variations between diastole and systole, which can be quantified with US imaging, increase significantly with the strength of the applied probe pressure on the patient's abdomen. The goal of this study is to investigate this effect more thoroughly. METHODS: With finite-element modeling, pulsatile blood pressure and probe pressure are simulated in three patient-specific geometries. Two distinct models for the aortic wall were simulated: a nonlinear hyperelastic and a linear elastic model. In addition, varying stiffness was considered for the surrounding tissues. The effect of light, moderate, and firm probe pressure was quantified on the stresses and strains in the aortic wall, and on two in vivo stiffness measures. In addition, the Elasticity Loss Index was proposed to quantify the change in stiffness due to probe pressure. RESULTS: Firm probe pressure decreased the measured aortic stiffness, and material stiffness was affected only when the wall was modeled as nonlinear, suggesting a shift in the stress-strain curve. In addition, stiffer surrounding tissues and a more elongated aneurysm sac decreased the responsiveness to the probe pressure. CONCLUSION: The effect of probe pressure on the AAA wall stiffness was clarified. In particular, the AAA wall nonlinear behavior was found to be of primary importance in determining the probe pressure response. Thus, further work will intend to make use of this novel finding in a clinical context.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39256142

RESUMEN

Reconstruction for large-scale temporomandibular joint (TMJ) defects can be challenging. Previously, we utilized the medial femoral condyle (MFC) flap for TMJ reconstruction. However, the optimal fixation method remains uncertain. In this study, finite element analysis was used to study the effects of three different fixation types of bone graft: overlap type, bevel type, and flush type. Models of different fixation types of MFC flap were reconstructed from CT images. A standard internal fixation model for extracapsular condylar fracture was also included as a control. Displacement of bone graft, deformation of plates and screws, and stress distribution of plates, screws, and cortical and cancellous of the bone graft were analyzed by finite element analysis to investigate their biomechanical features. The displacement of the bone graft and deformation of plates and screws in three different fixation types showed no significant difference. The overlap type and flush type of fixation displayed the lowest and highest stress respectively. All three fixation types could satisfy the mechanical requirement and face no risk of breakage and the major displacement of the MFC bone graft. These results provide insights into the optimal fixation approach for MFC bone grafts, offering valuable guidance and reference for clinical application.

4.
Materials (Basel) ; 17(17)2024 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-39274595

RESUMEN

The impact of perforation patterns on the compressive strength of cardboard packaging is a critical concern in the packaging industry, where optimizing material usage without compromising structural integrity is essential. This study aims to investigate how different perforation designs affect the load-bearing capacity of cardboard boxes. Utilizing finite element method (FEM) simulations, we assessed the compressive strength of packaging made of various types of corrugated cardboards, including E, B, C, EB, and BC flutes with different heights. Mechanical testing was conducted to obtain accurate material properties for the simulations. Packaging dimensions were varied to generalize the findings across different sizes. Results showed that perforation patterns significantly influenced the compressive strength, with reductions ranging from 14% to 43%, compared to non-perforated packaging. Notably, perforations on multiple walls resulted in the highest strength reductions. The study concludes that while perforations are necessary for functionality and aesthetics, their design must be carefully considered to minimize negative impacts on structural integrity. These findings provide valuable insights for designing more efficient and sustainable packaging solutions in the industry.

5.
Materials (Basel) ; 17(17)2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39274600

RESUMEN

Solid-state shear milling (S3M) equipment is an evolution from traditional stone mills, enabling the processing of polymer materials and fillers through crushing, mixing, and mechanochemical reactions at ambient temperature. Due to the complex structure of the mill-pan, empirical data alone are insufficient to give a comprehensive understanding of the physicochemical interactions during the milling process. To provide an in-depth insight of the working effect and mechanism of S3M equipment, finite element method (FEM) analysis is employed to simulate the milling dynamics, which substantiates the correlation between numerical outcomes and experimental observations. A model simplification strategy is proposed to optimize calculation time without compromising accuracy. The findings in this work demonstrate the S-S bond breakage mechanism behind stress-induced devulcanization and suggest the structural optimizations for enhancing the devulcanization and pulverization efficiency of S3M equipment, thereby providing a theoretical foundation for its application in material processing.

6.
Materials (Basel) ; 17(17)2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39274746

RESUMEN

Modeling the dynamic properties of wood and wood-based composites is a challenging task due to naturally growing structure and moisture-dependent material properties. This paper presents the finite element modeling of plywood panels' dynamic properties. Two panels differing in thickness were analyzed: (i) 18 mm and (ii) 27 mm. The developed models consisted of individual layers of wood, which were discretized using three-dimensional finite elements formulated using an orthotropic material model. The models were subjected to an updating procedure based on experimentally determined frequency response functions. As a result of a model updating relative errors for natural frequencies obtained numerically and experimentally were not exceeding 2.0%, on average 0.7% for 18 mm thick panel and not exceeding 2.6%, on average 1.5% for 27 mm thick panel. To prove the utility of the method and at the same time to validate it, a model of a cabinet was built, which was then subjected to experimental verification. In this case, average relative differences for natural frequencies of 6.6% were obtained.

7.
Sensors (Basel) ; 24(17)2024 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-39275732

RESUMEN

Recently, capacitive micromachined ultrasound transducers (CMUTs) with long rectangular membranes have demonstrated performance advantages over conventional piezoelectric transducers; however, modeling these CMUT geometries has been limited to computationally burdensome numerical methods. Improved fast modeling methods, such as equivalent circuit models, could help achieve designs with even better performance. The primary obstacle in developing such methods is the lack of tractable methods for computing the radiation impedance of clamped rectangular radiators. This paper presents a method that approximates the velocity profile using a polynomial shape model to rapidly and accurately estimate radiation impedance. The validity of the approximate velocity profile and corresponding radiation impedance calculation was assessed using finite element simulations for a variety of membrane aspect ratios and bias voltages. Our method was evaluated for rectangular radiators with width:length ratios from 1:1 up to 1:25. At all aspect ratios, the radiation resistance was closely modeled. However, when calculating the radiation reactance, our initial approach was only accurate for low aspect ratios. This motivated us to consider an alternative shape model for high aspect ratios, which was more accurate when compared with FEM. To facilitate the development of future rectangular CMUTs, we provide a MATLAB script that quickly calculates radiation impedance using both methods.

8.
Sci Rep ; 14(1): 20835, 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39242608

RESUMEN

This study investigates the impact of Al 2 O 3 particle volume fraction and distribution on the deformation and damage of particle-reinforced metal matrix composites, particularly in the context of functionally graded metal matrix composites. In this study, a two-dimensional nonlinear random microstructure-based finite element modeling approach implemented in ABAQUS/Explicit with a Python-generated script to analyze the deformation and damage mechanisms in AA 6061 - T 6 / Al 2 O 3 composites. The plastic deformation and ductile cracking of the matrix are captured using the Gurson-Tvergaard-Needleman model, whereas particle fracture is modelled using the Johnson-Holmquist II model. Matrix-particle interface decohesion is simulated using the surface-based cohesive zone method. The findings reveal that functionally graded metal matrix composites exhibit higher hardness values ( HRB ) than traditional metal matrix composites. The results highlight the importance of functionally graded metal matrix composites. Functionally graded metal matrix composites with a Gaussian distribution and a particle volume fraction of 10% achieve HRB values comparable to particle-reinforced metal matrix composites with a particle volume fraction of 20%, with only a 2% difference in HRB . Thus, HRB can be improved significantly by employing a low particle volume fraction and incorporating a Gaussian distribution across the material thickness. Furthermore, functionally graded metal matrix composites with a Gaussian distribution exhibit higher HRB values and better agreement with experimental distribution functions when compared to those with a power-law distribution.

9.
Int J Numer Method Biomed Eng ; : e3864, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39250194

RESUMEN

Heat transfer in the human eyeball, a complex organ, is significantly influenced by various pathophysiological and external parameters. Particularly, heat transfer critically affects fluid behavior within the eye and ocular drug delivery processes. Overcoming the challenges of experimental analysis, this study introduces a comprehensive three-dimensional mathematical and computational model to simulate the heat transfer in a realistic geometry. Our work includes an extensive sensitivity analysis to address uncertainties and delineate the impact of different variables on heat distribution in ocular tissues. To manage the model's complexity, we employed a very fast model reduction technique with certified sharp error bounds, ensuring computational efficiency without compromising accuracy. Our results demonstrate remarkable consistency with experimental observations and align closely with existing numerical findings in the literature. Crucially, our findings underscore the significant role of blood flow and environmental conditions, particularly in the eye's internal tissues. Clinically, this model offers a promising tool for examining the temperature-related effects of various therapeutic interventions on the eye. Such insights are invaluable for optimizing treatment strategies in ophthalmology.

10.
J Mech Behav Biomed Mater ; 158: 106682, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39142234

RESUMEN

In virtual surgical training, it is crucial to achieve real-time, high-fidelity simulation of the tissue deformation. The anisotropic and nonlinear characteristics of the organ with multi-component make accurate real-time deformation simulation difficult. A localized tissue constraint progressive transfer learning method is proposed in this paper, where the base-compensated dual-output transfer learning strategy and the localized tissue constraint progressive learning architecture are developed. The proposed strategy enriches the multi-component biomechanical dataset to fully represent complex force-displacement with minimal high-quality data. Meanwhile, the proposed architecture adopts focused and progressive model to accurately describe tissues with varied biomechanical properties rather than singular homogeneous model. We made comparison with 4 state-of-the-art (SOTA) methods in simulating multi-component biomechanical deformations of organs with 100 pairs of testing data. Results show that the accuracy of our method is 50% higher than other methods in different validation matrix. And our method can stably simulate the deformations in 0.005 s per frame, which largely improves the computing efficiency.


Asunto(s)
Fenómenos Mecánicos , Fenómenos Biomecánicos , Simulación por Computador , Factores de Tiempo , Aprendizaje Automático , Humanos
11.
Comput Methods Programs Biomed ; 255: 108362, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39163784

RESUMEN

BACKGROUND AND OBJECTIVES: Techniques for imaging the mechanical properties of cells are needed to study how cell mechanics influence cell function and disease progression. Mechano-microscopy (a high-resolution variant of compression optical coherence elastography) generates elasticity images of a sample undergoing compression from the phase difference between optical coherence microscopy (OCM) B-scans. However, the existing mechano-microscopy signal processing chain (referred to as the algebraic method) assumes the sample stress is uniaxial and axially uniform, such that violation of these assumptions reduces the accuracy and precision of elasticity images. Furthermore, it does not account for prior information regarding the sample geometry or mechanical property distribution. In this study, we investigate the feasibility of training a conditional generative adversarial network (cGAN) to generate elasticity images from phase difference images of samples containing a cell spheroid embedded in a hydrogel. METHODS: To construct the cGAN training and simulated test sets, we generated 30,000 artificial elasticity images using a parametric model and computed the corresponding phase difference images using finite element analysis to simulate compression applied to the artificial samples. We also imaged real MCF7 breast tumor spheroids embedded in hydrogel using mechano-microscopy to construct the experimental test set and evaluated the cGAN using the algebraic elasticity images and co-registered OCM and confocal fluorescence microscopy (CFM) images. RESULTS: Comparison with the simulated test set ground truth elasticity images shows the cGAN produces a lower root mean square error (median: 3.47 kPa, 95 % confidence interval (CI) [3.41, 3.52]) than the algebraic method (median: 4.91 kPa, 95 % CI [4.85, 4.97]). For the experimental test set, the cGAN elasticity images contain features resembling stiff nuclei at locations corresponding to nuclei seen in the algebraic elasticity, OCM, and CFM images. Furthermore, the cGAN elasticity images are higher resolution and more robust to noise than the algebraic elasticity images. CONCLUSIONS: The cGAN elasticity images exhibit better accuracy, spatial resolution, sensitivity, and robustness to noise than the algebraic elasticity images for both simulated and real experimental data.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Elasticidad , Esferoides Celulares , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Células MCF-7 , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Redes Neurales de la Computación , Microscopía/métodos , Tomografía de Coherencia Óptica/métodos , Análisis de Elementos Finitos
12.
MethodsX ; 13: 102837, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39092280

RESUMEN

In this study, the control volume method is used to determine the air temperature at the outlet of an air-to-ground heat exchanger. Its implementation consists in dividing the duct of the ground-air heat exchanger into micro-volumes of identical size. An energy balance is then established for each micro-volume. The input parameters used to implement this model are related to the city of Yaoundé in the equatorial zone. The results show that when the total length of the air-to-ground heat exchanger duct varies between 0 and 100 m, the air temperature at the outlet also varies between 34.5 and 24 °C. The air-to-ground heat exchanger operates in cooling mode. As the length of the air-to-ground heat exchanger duct increases, the temperature of the air at the outlet of the air-to-ground heat exchanger decreases, approaching that of the ground. Based on the results obtained using the control volume model, the minimum total length of air-to-ground heat exchanger duct recommended for this zone is 40 m. Admittedly, air pressure drops, air humidity and the geometry of the air-to-ground heat exchanger are aspects that have not yet been taken into account in the implementation of this model. Nevertheless, the control volume method can be used to optimise the parameters influencing the thermal performance of an air-to-ground heat exchanger.•The control volume method is implemented here by dividing the air-to-ground heat exchanger duct into identical micro-volumes and then establishing an energy balance for each micro-volume;•In this work, the control volume method was used to optimise the total length of the duct of a ground air heat exchanger installed in an equatorial zone;•Some important aspects such as air pressure drops, air humidity, and the geometry of the air-to-ground heat exchanger are not yet taken into account in the implementation of the control volume method.

13.
Korean J Orthod ; 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39175205

RESUMEN

Objective: To evaluate tooth displacement and periodontal stress generated by the dual action vertical intra-arch technique (DAVIT) for open-bite correction using three-dimensional finite element analysis. Methods: A three-dimensional model of the maxilla was created by modeling the cortical bone, cancellous bone, periodontal ligament, and teeth from the second molar to the central incisor of a hemiarch. All orthodontic devices were designed using specific software to reproduce their morpho-dimensional characteristics, and their physical properties were determined using Young's modulus and Poisson's coefficient of each material. A linear static simulation was performed to analyze the tooth displacements (mm) and maximum stresses (Mpa) induced in the periodontal ligament by the posterior intrusion and anterior extrusion forces generated by the DAVIT. Results: The first and second molars showed the greatest intrusion, whereas the canines and lateral incisors showed the greatest extrusion displacement. A neutral zone of displacement corresponding to the fulcrum of occlusal plane rotation was observed in the premolar region. Buccal tipping of the molars and lingual tipping of the anterior teeth occurred with intrusion and extrusion, respectively. Posterior intrusion generated compressive stress at the apex of the buccal roots and furcation of the molars, while anterior extrusion generated tensile stress at the apex and apical third of the palatal root surface of the incisors and canines. Conclusions: DAVIT mechanics produced a set of beneficial effects for open-bite correction, including molar intrusion, extrusion and palatal tipping of the anterior teeth, and occlusal plane rotation with posterior teeth uprighting.

14.
Front Neurol ; 15: 1417711, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39175763

RESUMEN

Active middle ear implants (AMEI) amplify mechanical vibrations in the middle ear and transmit them to the cochlea. The AMEI includes a floating mass transducer (FMT) that can be placed using two different surgical approaches: "oval window (OW) vibroplasty" and "round window (RW) vibroplasty." The OW and RW are windows located on the cochlea. Normally, sound stimulus is transmitted from the middle ear to cochlea via the OW. RW vibroplasty has been suggested as an alternative method due to the difficulty of applying OW vibroplasty in patients with ossicle dysfunction. Several reports compare the advantages of each approach through pre and postoperative hearing tests. However, quantitatively assessing the treatment effect is challenging due to individual differences in pathologies. This study investigates the vibration transmission efficiency of each surgical approach using a finite-element model of the human cochlea. Vibration of the basilar membrane (BM) of the cochlea is simulated by applying the stimulus through the OW or RW. Pathological conditions, such as impaired stapes mobility, are simulated by increasing the stiffness of the stapedial annular ligament. RW closure due to chronic middle ear diseases is a common clinical occurrence and is simulated by increasing the stiffness of the RW membrane in the model. The results show that the vibration amplitude of the BM is larger when the stimulus is applied to the RW compared to the OW, except for cases of RW membrane ossification. The difference in these amplitudes is particularly significant when stapedial mobility is limited. These results suggest that RW vibroplasty would be advantageous, especially in cases of accompanying stapedial mobility impairment. Additionally, it is suggested that transitioning to OW vibroplasty could still ensure a sufficient level of vibratory transmission efficiency when placing the FMT on the RW membrane is difficult due to anatomical problems in the tympanic cavity or confirmed severe pathological conditions around the RW.

16.
Heliyon ; 10(14): e34650, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39114025

RESUMEN

The objective of the present research is to explore the temperature diffusion in healthy and cancerous tissues, with a specific focus on how physical activity impacts on the weakening of breast tumors. Previous research lacked numerical analysis regarding the effectiveness of physical activity in tumor prevention or attenuation, prompting an investigation into the mechanism behind physical activity and tumor prevention from a bio-heat transfer perspective. The study employs a realistic model of human breasts and tumors in COMSOL Multiphysics® to analyze temperature distribution by utilizing Penne's bio-heat equation. The research examines their influence on tissue temperature by varying tumor diameter (10-20 mm) and exercise intensities (such as walking speeds and other activities like carpentry, swimming, and marathon running). Results demonstrate that cancerous tissues generate notably more heat than normal tissues at rest and during physical activity. Smaller tumors exhibit higher temperatures during exercise, emphasizing the significance of tumor size in treatment effectiveness. Tumor temperatures range between 40 and 43.2 °C, while healthy tissue temperatures remain below 41 °C during physical activity. High-intensity exercises, particularly swimming, walking at 1.8 m/s, and marathon running, display a therapeutic effect on tumors, increasing effectiveness with intensity. The temperatures of healthy and malignant tissues rise noticeably due to constant metabolic heat and decreased blood flow. The study also identifies the optimal duration of high-intensity exercise, recommending at least 20 min for optimal therapeutic outcomes. The outcomes of this research would help individuals, doctors, and cancer researchers understand and weaken malignant tissues.

17.
Knee ; 50: 41-58, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39116664

RESUMEN

PURPOSE: A personalized model of the knee joint, with adjustable effective geometric parameters for the transplanted autograft diameter in Anterior Cruciate Ligament Reconstruction (ACLR) using the bone-patella-tendon-bone (BPTB) technique, has been developed. The model will assist researchers in understanding how different graft sizes impact a patient's recovery over time. METHODS: The study involved selecting a group of individuals without knee injuries and one patient who had undergone knee surgery. Gait analysis was conducted on the control group and the patient at various time points. A 3D model of the knee joint was created using medical images of the patient. Forces and torques obtained from the gait analysis were applied to the model to perform finite element analysis. RESULTS: The results of the finite element (FE) analysis, along with kinetic data from both groups, indicate that models with diameters of 7.5 mm and 12 mm improved joint motion during follow-up after ACLR. Additionally, a comparison of the stress applied to the ACL model revealed that a 12 mm autograft diameter showed a more favorable trend in patient recovery during the three follow-up intervals after ACL reconstruction surgery. CONCLUSION: The development of a personalized parametric model with adjustable geometric parameters in ACLR, such as the transplanted autograft diameter, as presented in this study, along with FE using the patient's kinetic data, allows for the examination and selection of an appropriate autograft diameter for Patella Tendon grafting. This can help reduce stress on the autograft and prevent damage to other knee joint tissues after ACLR.

18.
Sci Rep ; 14(1): 18017, 2024 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-39097630

RESUMEN

For the polarization multiplexing requirements in all-optical networks, this work presents a compact all-fiber polarization beam splitter (PBS) based on dual-core photonic crystal fiber (PCF) and an elliptical gold layer. Numerical analysis using the finite element method (FEM) demonstrates that the mode modulation effect of the central gold layer effectively reduces the dimensions of the proposed PBS. By determining reasonable structural parameters of the proposed PCF, the coupling length ratio (CLR) between X- and Y-polarized super-modes can approach 2, achieving a minimal device length of 0.122 mm. The PBS exhibits a maximum extinction ratio (ER) of - 65 dB at 1.55 µm, with an operating bandwidth spanning 100 nm (1.5-1.6 µm) and a stable insertion loss (IL) of ~ 1.5 dB at 1.55 µm. Furthermore, the manufacture feasibility and performance verification scheme are also investigated. It is widely anticipated that the designed PBS will play a crucial role in the ongoing development process of miniaturization and integration of photonic devices.

19.
Sci Rep ; 14(1): 18362, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39112616

RESUMEN

This work revisits the notion of complex step derivative approximation (CSDA) and presents its use in constitutive model of a class of nonlinear viscoelastic materials. The effectiveness of a CSDA is evaluated by putting it through a series of straightforward examples. After that, the idea of the CSDA is put to use in order to carry out a numerical evaluation of the algorithmic tangent moduli of a viscoelastic constitutive model. The performance of the constitutive models is evaluated through the use of three different numerical tests, and the results are compared to those that were achieved by the application of an analytical method. In comparison to other numerical differentiation techniques, It has been found that the CSDA scheme is the most computationally efficient and robust method of numerical differentiation, regardless of the size of the finite difference interval.

20.
Cogn Neurodyn ; 18(4): 2031-2045, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39104691

RESUMEN

Temporal interference deep-brain magnetic stimulation (TI-DMS) induces rhythmic electric field (EF) in the hippocampus to normalize cognitive function. The rhythmic time series of the hippocampal EF is essential for the assessment of TI-DMS. However, the finite element method (FEM) takes several hours to obtain the time series of EF. In order to reduce the time cost, the temporal convolutional network (TCN) model is adopted to predict the time series of hippocampal EF induced by TI-DMS. It takes coil configuration and loaded current as input and predicts the time series of maximum and mean values of the left and right hippocampal EF. The prediction takes only a few seconds. The model parameter combination of kernel size and layers is selected optimally by cross-validation method. The experimental results for multiple subjects show that the R2 of all the time series predicted by the model exceed 0.98. And the prediction accuracy is even higher as the input parameters approach the training set. These results demonstrate that the adopted model can quickly predict the time series of hippocampal EF induced by TI-DMS with relatively high accuracy, which is beneficial for future clinical applications.