Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 516
Filtrar
1.
Clin Chem Lab Med ; 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39238208

RESUMEN

OBJECTIVES: This study aimed to assess the validity of external quality assessment (EQA) laboratory results across various cultural and environmental contexts and to identify potential improvement areas. METHODS: The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Task Force on Global Laboratory Quality (TF-GLQ) conducted a 2-year study (2022 and 2023) in which EQA materials, related software and online training was provided by a commercial vendor to 100 laboratories in ten IFCC member society countries. The results were analysed on a monthly basis by the TF-GLQ, to show the number of submissions per country, tests per lab, acceptability rates, random failures and to get a measure of which analytes performed poorly. RESULTS: The EQA material was dispatched on a quarterly basis. Some countries had problems with customs releasing the material in a timely manner, resulting in laboratories not receiving them on time leading to no submission. We report here the results for the second year of the survey. The number of examinations varied between laboratories, ranging from seven to 84 analytes. Of the ten countries surveyed, six averaged greater than 90 % acceptable results over the whole 12-months cycle, one had unacceptable results for two of the nine months they returned results and the other four were considered to not perform to an acceptable standard. CONCLUSIONS: All 100 participating laboratories indicated satisfaction with the EQA survey and related services, including on-site training, and report handling. However, specimen receiving issues, suggest benefits in dispatching materials for a full 12-month cycle. Significant discrepancies in EQA performance indicate that four countries require long-term assistance, training and guidance. To ensure reliable patient results, promoting EQA in certain countries is essential to achieve the required level of quality.

2.
Virchows Arch ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39120655

RESUMEN

This study describes the external quality assessment (EQA) scheme for molecular testing of RET alterations in non-small cell lung cancer (NSCLC), medullary thyroid carcinomas (MTC), and non-MTC. The lead panel institute and Quality Assurance Initiative in Pathology (Qualitätssicherungs-Initiative Pathologie [QuIP] GmbH) selected formalin-fixed paraffin-embedded (FFPE) tissue from MTC for RET mutation testing by next-generation sequencing (NGS) methods and FFPE tissue from NSCLC and non-MTC for RET gene fusion testing using either in situ hybridisation (ISH) or NGS methods, forming 3 sub-schemes of the EQA scheme. Tissue material underwent an internal validation phase followed by an external testing phase. The internal validation phase served as a cross-validation step conducted by panel institutes. In the external testing phase, the number of participating institutes in the RET point mutation sub-scheme, RET fusion (ISH) sub-scheme, and RET fusion (NGS) sub-scheme was 32, 24, and 38, respectively. The reported success rates for external testing were 96.0%, 89.5%, and 93.5% for the RET point mutation, the ISH RET fusion, and the NGS RET fusion EQA sub-schemes, respectively. These findings confirm the reliability of the NGS method in detecting RET alterations and align with current screening recommendations. Overall, 31 institutes were certified for RET point mutation testing by NGS methods, 22 institutes were certified for RET fusion testing by ISH, and 36 institutes were certified for RET fusion testing by NGS methods. Results can be employed to inform real-world diagnostic decisions in Germany, Austria, and Switzerland.

3.
Front Mol Biosci ; 11: 1401405, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39176390

RESUMEN

Background: C-reactive protein (CRP) is an established serum biomarker for different pathologies such as tissue injury and inflammatory events. One rising area of interest is the incorporation of low concentrations of CRP, so called high-sensitive (hs-) CRP, in the risk assessment and treatment monitoring of cardiovascular diseases (CVDs). Many research projects and the resulting meta-analyses have reported controversial results for the use of hs-CRP, especially in the risk assessment of CVDs. However, since these analyses used different assays to detect hs-CRP, it is important to assess the current level of assay harmonization. Methods: This paper analyzes data from 17 external quality assessment (EQA) surveys for hs-CRP conducted worldwide between 2018 and 2023. Each EQA survey consisted of two blinded samples. In 2020 the sample material changed from pooled serum to single-donor samples. The aim was to assess the current status of assay harmonization by a manufacturer-based approach, taking into consideration the clinical decision limits for hs-CRP risk-stratification of CVDs as well as the scatter of results. Results: Our analyses show that harmonization has increased in recent years from median differences of up to 50% to below 20%, with one exception that showed an increasing bias throughout the observed period. After changing sample materials from pools to single-donor samples, the coefficient of variation decreased to below 10% with one exception. Nevertheless, even these differences in the clinical setting could lead to disparate classification of patients depending on the assay used. Conclusion: While there was a positive trend towards harmonization, meta-analysis of different risk-score publications should stratify their analysis by assay to account for the manufacturer-specific differences observed in this paper. Furthermore, assays are currently traceable to different international standard preparations, which might have a negative impact on future harmonization.

5.
Vaccines (Basel) ; 12(8)2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39203950

RESUMEN

More than 100 laboratories in the World Health Organization Global Measles and Rubella Laboratory Network (GMRLN) perform nucleic acid-based methods for case confirmation of measles or rubella infections and/or strain surveillance (genotyping). The quality of laboratory data is critical to ensure that diagnostic results and country reports to regional verification committees are based on accurate data. A molecular External Quality Assurance (mEQA) program was initiated by the US-CDC in 2014 to evaluate the performance of laboratories in the network. The inclusion of testing for measles and rubella viruses, with a focus on detection and genotyping, plus the diversity of assays and platforms employed required a flexible and comprehensive proficiency testing program. A stepwise introduction of new evaluation criteria gradually increased the stringency of the proficiency testing program, while giving laboratories time to implement the required changes. The mEQA program plays an important role in many processes in the GMRLN, including informing plans for the training of laboratory staff, access to reagents, and the submission of sequence data to global databases. The EQA program for Local Public Health Institutes in Japan is described as an example for national mEQA programs. As more laboratories initiate molecular testing, the mEQA will need to continue to expand and to adapt to the changing landscape for molecular testing.

6.
Clin Chim Acta ; 565: 119950, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39214395

RESUMEN

BACKGROUND AND AIMS: Testing for coagulation factors VIII (FVIII) and IX (FIX) plays significant importance in the diagnostic and treatment of hemophilia A and B. External quality assessment (EQA) scheme aimed to assess the participants' performance of testing for coagulation factors and identify shortcomings in clinical practice. This study aimed to investigate the performance trends of the participating laboratories in China national external quality assessment Scheme (China NEQAS) for FVIII and FIX over a five-year period (2019-2023). MATERIALS AND METHODS: A total of ten external quality assessment (EQA) rounds were conducted from 2019 to 2023 in the China NEQAS for FVIII and FIX. The distribution of method, reagent and instrument were calculated. The trends of method- specific inter-laboratory coefficient of variation (CV) and pass rates were analyzed over 5 years. The dilutions for coagulation factor testing were also investigated. RESULTS: All laboratories use one-stage assays to detect FVIII and FIX activity. The inter-laboratory overall CV decreased year by year (10.9 % to 9.3 % for FVIII and 13.5 % to 10.2 % for FIX), and the laboratory pass rate steadily increased (88.0 % to 93.4 % for FVIII and 81.3 % to 92.7 % for FIX). The majority of laboratories employed a single dilution methodology for the assessment of FVIII and FIX activity. The interlaboratory CV was elevated for the Siemens reagent (Actin FSL) during analysis of moderately abnormal FIX concentrations of EQA samples in most batches. CONCLUSIONS: The implementation of the external quality assessment has contributed to facilitate the enhancement of testing quality. Chromogenic assay is a supplement to accurate determination when necessary. Laboratories may choose to perform dilution tests or direct assays to identify the presence of inhibitors, particularly when they are suspected.

7.
Diagnosis (Berl) ; 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38950285

RESUMEN

OBJECTIVES: Since December 2019, worldwide public health has been exposed to a severe acute respiratory syndrome caused by Coronavirus-2. Serological testing is necessary for retrospective assessment of seroprevalence rates, and the determination of vaccine response and duration of immunity. For this reason, it was necessary to introduce a panel of tests able to identify and quantify Covid-19 antibodies. METHODS: As a Regional Reference Centre, the CRQ Laboratory (Regional Laboratory for the Quality Control) developed and conducted an External Quality Assessment (EQA) panel of assays, to evaluate the quality of various methods, that were used by 288 Sicilian laboratories, previously authorized on behalf of the Public Health Service. RESULTS: The performance test was based on pooled samples with different levels of concentration of antibodies. 97 , 98, and 95 % of the participating laboratories tested all samples correctly in 2020, 2021, and 2022 respectively. The best performance was observed in the test of total Ig. The general performance of laboratories improved over the years. CONCLUSIONS: The incorrect diagnosis had and could still have important implications on vaccination cycles. Only through the effort of laboratory professionals, and the extension of the EQA scheme, a better harmonization of methods, protocols, and thus results, to guarantee a better healthcare system, will be possible.

8.
Front Mol Biosci ; 11: 1401619, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38966130

RESUMEN

Background: Tumor markers are established laboratory tools that help to diagnose, estimate prognosis, and monitor the course of cancer. For meaningful decision-making in patient care, it is essential that methods and analytical platforms demonstrate high sensitivity, specificity, precision, and comparability. Regular participation at external quality assessment (EQA) schemes is mandatory for laboratories. Here, a longitudinal evaluation of EQA data was performed to assess the performance of tumor marker assays over time. Methods: Longitudinal data of the cancer antigens (CA) 15-3 (n = 5,492), CA 19-9 (n = 6,802), and CA 125 (n = 5,362) from 14 INSTAND EQAs conducted between 2019 and 2023 were evaluated. A median of 197, 244 and 191 laboratories participated at the EQAs for CA 15-3, CA 19-9 and CA 125, respectively. Data evaluation encompasses intra- and inter-manufacturer specific variations over time, assay precision, and adherence to the EQA limits of ±24% for CA 15-3, ±27% for CA 19-9 and ±36% for CA 125. Results: The study showed median manufacturer-dependent differences of up to 107% for CA 15-3, 99% for CA 125, and even 549% for CA 19-9 between the highest and the lowest methods over the studied period. Regarding the normalized median of all methods, the values of the most deviant methods were 0.42 for CA 15-3, 7.61 for CA 19-9, and 1.82 for CA 125. Intra-manufacturer variability was generally low, with median coefficients of variation (CV) below 10%. As the methods were evaluated according to method-specific consensus values, most participants passed the EQAs within the acceptance criteria. When the criteria were consistently set at 24%, the central 90% of participants passed the EQAs in 78.6%-100% for CA 15-3 (with exception of AX), 89.3%-100% for CA 125, and 64.3%-100% for CA 19-9. Conclusion: While intra-method precision of most analytical platforms is acceptable for all three tumor markers, considerable inter-method variability was observed over the whole studied period demonstrating the necessity for better standardization and harmonization of the methods, development of international reference materials, and comprehensive commutability studies with patient samples.

9.
Clin Chim Acta ; 562: 119880, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39038590

RESUMEN

BACKGROUND AND AIMS: To investigate performance of D-dimer assays in China and address analytical quality issues. MATERIALS AND METHODS: D-dimer assays data were collected from China National External Quality Assessment Scheme (China NEQAS) from 2014 to 2022. We analyzed reagents, assay results, reporting unit and cutoffs in 2022 China NEQAS. Interlaboratory coefficient variations (CVs) and influence of modified/unmodified test systems on CVs were investigated over 9 years. RESULTS: There were 82 reagent brands in China NEQAS, but 55 reagent instructions did not indicate expression unit (DDU or FEU). Up to 7-fold of the ratio of max-to-min mean results was shown among different assays with same unit on the same sample. A prevalence of FEU (63.4%) over DDU (17.1%) was observed. Although 669 laboratories (37.9%) among 1766 laboratories used reagents without VTE exclusion claim, they also reported cutoffs. The CVs of only two assays were decreasing over years. CVs of modified test systems were higher than those of unmodified systems before improvement. CONCLUSIONS: Expression unit should be required to label in package inserts by regulatory authority. Laboratory professionals should follow instructions for use and prefer unmodified test systems for clinical safely application. Harmonization of reporting units through collaborative efforts is the promising step.


Asunto(s)
Productos de Degradación de Fibrina-Fibrinógeno , Laboratorios Clínicos , Humanos , Productos de Degradación de Fibrina-Fibrinógeno/análisis , China , Laboratorios Clínicos/normas , Control de Calidad , Garantía de la Calidad de Atención de Salud , Pueblos del Este de Asia
10.
Ann Clin Biochem ; : 45632241269741, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39054266

RESUMEN

BACKGROUND: As one of the most requested profiles of blood tests, there is a need for standardization among liver function tests (LFT). Alanine aminotransferase (ALT) and aspartate aminotransferase (AST) are key markers of hepatocellular injury. ALT and AST are used to calculate a Fibrosis-4 (FIB-4) score for assessing liver fibrosis. Despite recommendations by the International Federation of Clinical Chemistry (IFCC) to include pyridoxal-5-phosphate in ALT and AST assay methodologies, most laboratories continue to omit this. METHODS: Data from the UK NEQAS for Clinical Chemistry Scheme, Distribution 1160 (November 2023), was reviewed to investigate variation in practice regarding liver blood tests in relation to ALT, AST and FIB-4. In addition, a series of questions audited laboratory practice in relation to liver enzymes. RESULTS: Wide variation was seen in LFT profiles offered by laboratories, with 32 different combinations of tests used. The IFCC-recommended methods for ALT and AST are used by one-third of laboratories and give significantly higher results than non-IFCC methods. Laboratories using IFCC methods also reported significantly higher FIB-4 scores. Reference ranges and cut-offs for these tests also varied, and did not account for method-related differences in results. CONCLUSIONS: The lack of standardization of LFTs can have a significant impact on patient care. The difference in results for ALT, AST and FIB-4 in laboratories not using IFCC-recommended methods may lead to misdiagnosis. This issue should be addressed by laboratories using methods including pyridoxal-5-phosphate. Until then, method-related reference ranges and cut-offs for ALT, AST and FIB-4 are required.

11.
Front Mol Biosci ; 11: 1390079, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38974321

RESUMEN

Introduction: This study presents a longitudinal analysis of external quality assessment (EQA) results for erythropoietin (EPO) determinations conducted between 2017 and 2022 with a continuously increasing number of participating laboratories. The aim of this work was to evaluate participant performance and methodological aspects. Methods: In each of the eleven EQA surveys, a blinded sample set of lyophilized human serum containing one sample with lower EPO concentrations (L) and one with higher EPO concentrations (H) was sent to the participating laboratories. Results: A total of 1,256 measurements were included. The median (interquartile range) fraction of participants not meeting the criteria of acceptance set at 20% around the robust mean of the respective survey was 9.5% (6.1%-10.7%) (sample L) and 9.1% (5.8%-11.8%) (sample H) but lacked a clear trend in the observed period. Some surveys exhibited unusually high interlaboratory variation, suggesting interfering components in the EQA samples. Different immunological methods and reagent manufacturers also showed variability in measurement outcomes to some extent. Conclusion: These findings highlight the need for continuous quality assessment in EPO measurements to ensure patient safety and identify areas for further research and investigation.

12.
Am J Clin Pathol ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39024475

RESUMEN

OBJECTIVES: Our objective was to maintain low interlaboratory variation and bias in international normalized ratio (INR) results following a network change in instrumentation and reagents, using a process of ongoing standardization and harmonization. METHODS: Network-wide standardization to new common instrument and reagent platforms followed by network-wide application of a simple novel process of verification of international sensitive index and mean normal prothrombin time values for each new lot of prothrombin time (PT) reagent that does not require use of World Health Organization reference thromboplastin or INR calibration/certified plasma. RESULTS: The network transitioned from mechanical hemostasis detection instruments with associated PT reagent (Diagnostica Stago; NeoPTimal) to optical detection (ACL TOPs) with associated PT reagent (Werfen; RecombiPlasTin 2G). Comparing 3 years of data for each situation, the network (n = 27 laboratories) maintained low INR variability and bias relative to general mechanical and optical groups and other laboratories. CONCLUSIONS: Harmonized support for patient management of vitamin K antagonists such as warfarin was continuously maintained in our geography, with potentially positive implications for other coagulation laboratories and geographies. For the United States in particular, paucity of US Food and Drug Administration-cleared INR certified plasmas potentially compromises INR test accuracy; our novel approach may provide workable alternatives for other laboratories/networks.

13.
Clin Chem Lab Med ; 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39027966

RESUMEN

OBJECTIVES: This article defines analytical performance specifications (APS) for evaluating laboratory proficiency through an external quality assessment scheme. METHODS: Standard deviations for proficiency assessment were derived from Thompson's characteristic function applied to robust data calculated from participants' submissions in the Occupational and Environmental Laboratory Medicine (OELM) external quality assurance scheme for trace elements in serum, whole blood and urine. Characteristic function was based on two parameters: (1) ß - the average coefficient of variation (CV) at high sample concentrations; (2) α - the average standard deviation (SD) at low sample concentrations. APSs were defined as 1.65 standard deviations calculated by Thompson's approach. Comparison between OELM robust data and characteristic function were used to validate the model. RESULTS: Application of the characteristic function allowed calculated APS for 18 elements across three matrices. Some limitations were noted, particularly for elements (1) with no sample concentrations near analytical technique limit of detection; (2) exhibiting high robust CV at high concentration; (3) exhibiting high analytical variability such as whole blood Tl and urine Pb; (4) with an unbalanced number of robust SD above and under the characteristic function such as whole blood Mn and serum Al and Zn. CONCLUSIONS: The characteristic function was a useful means of deriving APS for trace elements in biological fluids where biological variation data or outcome studies were not available. However, OELM external quality assurance scheme data suggests that the characteristic functions are not appropriate for all elements.

14.
Ann Lab Med ; 44(6): 507-517, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-38953114

RESUMEN

Background: The accurate measurement of α-fetoprotein (AFP) is critical for clinical diagnosis. However, different AFP immunoassays may yield different results. Appropriate AFP reference materials (RMs) were selected and assigned accurate values for applications with external quality assessment (EQA) programs to standardize AFP measurements. Methods: Forty individual clinical samples and six different concentrations of candidate RMs (Can-RMs, L1-L6) were prepared by the Beijing Center for Clinical Laboratories. The Can-RMs were assigned target values by performing five immunoassays, using WHO International Standard 72/225 as a calibrator, and sent to 45 clinical laboratories in Beijing for AFP measurements. The commutability of all RMs was assessed based on CLSI and the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) approaches. Analytical performance was assessed for compliance based on accuracy (total error, TE), trueness (bias), and precision (CV). Results: The Can-RMs were commutable for all immunoassays using the CLSI approach and for 6 of 10 assay combinations using the IFCC approach. RMs diluted in WHO RM 72/225 were commutable among all assays with the CLSI approach, except for serum matrix (Autolumo vs. Roche analyzer) and diluted water matrix (Abbott vs. Roche/Mindray analyzer), whereas some inconclusive and non-commutable results were found using the IFCC approach. The average pass rates based on the TE, bias, and CV were 91%, 81%, and 95%, respectively. Conclusions: The commutability of the RMs differed between both evaluation approaches. The Can-RMs exhibited good commutability with the CLSI approach, suggesting their suitability for use with that approach as commutable EQA materials with assigned values and for monitoring the performance of AFP measurements.


Asunto(s)
Estándares de Referencia , alfa-Fetoproteínas , alfa-Fetoproteínas/análisis , alfa-Fetoproteínas/normas , Humanos , Inmunoensayo/normas , Inmunoensayo/métodos , Calibración , Control de Calidad , Laboratorios Clínicos/normas
15.
Diagnostics (Basel) ; 14(12)2024 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-38928636

RESUMEN

The present study focuses on establishing the quality assurance of laboratories for recent infections (RTRI) in Thailand. We developed a cold-chain independent method, using fully characterized plasma obtained from the Thai Red Cross Society, and prepared as dried tube specimens (DTS). Twenty microliters of HIV-seronegative, recent, and long-term infected samples were aliquoted into individual tubes and dried at room temperature, 20-30 degrees Celsius, in a biosafety cabinet overnight to ensure optimal preservation. The DTS external quality control and external quality assessment were tested for homogeneity and stability following the ISO/Guide 35 guidelines. The DTS panels were distributed to 48 sites (FY 2022) and 27 sites (FY 2023) across 14 and 9 provinces, respectively, in Thailand. The results from participating laboratories were collected and evaluated for performance. The results were scored, and acceptable performance criteria were defined as the proportion of panels correctly tested, which was set at 100%. The satisfactory performance ranged from 96% to 100% and was not significantly different among the 13 health regions. The developed and implemented DTS panels can be used to monitor the quality of RTRI testing in Thailand.

16.
Front Mol Biosci ; 11: 1395410, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38828394

RESUMEN

External Quality Assessment schemes (EQAS) are mandatory to ensure quality standards in diagnostic methods and achieve laboratory accreditation. As host institution for two German culture-based bacteriology EQAS (RV-A and RV-B), we investigated the obtained data of 590 up to 720 surveys per year in RV-A and 2,151 up to 2,929 in RV-B from 2006 to 2023. As educational instruments, they function to review applied methodology and are valuable to check for systemic- or method-dependent failures in microbiology diagnostics or guidelines. Especially, containment of multi-resistant bacteria in times of rising antibiotic resistance is one major point to assure public health. The correct identification and reporting of these strains is therefore of high importance to achieve this goal. Moreover, correct antimicrobial susceptibility testing (AST) per se is important for selecting appropriate therapy, to restrict broad-spectrum antibiotics and minimize resistance development. The reports of participating laboratories displayed a high level of correct identification results in both schemes with mostly consistent failure rates around 2.2% (RV-A) and 3.9% (RV-B) on average. In contrast, results in AST revealed increasing failure rates upon modification of AST requirements concerning adherence to standards and subsequent bacterial species-specific evaluation. Stratification on these periods revealed in RV-A a moderate increase from 1.3% to 4.5%, while in RV-B failure rates reached 14% coming from 4.3% on average. Although not mandatory, subsequent AST evaluation and consistent reporting are areas of improvement to benefit public health.

17.
Eur J Clin Microbiol Infect Dis ; 43(8): 1597-1607, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38833104

RESUMEN

PURPOSE: To comprehensively investigate the diagnostic performance of routinely used assays in MPXV testing, the National Center of Clinical Laboratories in China conducted a nationwide external quality assessment (EQA) scheme and an evaluated nine assays used by ≥ 5 laboratories in the EQA. METHODS: MPXV virus-like particles with 2700, 900 and 300 copies/mL were distributed to 195 EQA laboratories. For extended analysis, triple-diluted samples from 9000 to 4.12 copies/mL were repeated 20 times using the assays employed by ≥ 5 laboratories. The diagnostic performance was assessed by analyzing EQA data and calculating the limits of detection (LODs). RESULTS: The performance was competent in 87.69% (171/195) of the participants and 87.94% (175/199) of the datasets. The positive percentage agreements (PPAs) were greater than 99% for samples at 2700 and 900 copies/mL, and 95.60% (761/796) for samples at 300 copies/mL. The calculated LODs for the two clades ranged from 228.44 to 924.31 copies/mL and were greater than the LODs specified by the respective kits. EasyDiagnosis had the lowest calculated LODs and showed superior performance in EQA, whereas BioGerm and Sansure, with higher calculated LODs, did not perform well in EQA. CONCLUSION: This study provides valuable information from the EQA data and evaluation of the diagnostic performance of MPXV detection assays. It also provided insights into reagent optimization and enabled prompt public health interventions for the outbreak.


Asunto(s)
Reacción en Cadena en Tiempo Real de la Polimerasa , Sensibilidad y Especificidad , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , China/epidemiología , Límite de Detección , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Monkeypox virus/genética , Monkeypox virus/aislamiento & purificación
18.
BMC Infect Dis ; 24(1): 646, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937708

RESUMEN

INTRODUCTION: When COVID-19 hit the world in 2019, an enhanced focus on diagnostic testing for SARS-CoV-2 was essential for a successful pandemic response. Testing laboratories stretched their capabilities for the new coronavirus by adopting different test methods. The necessity of having external quality assurance (EQA) mechanisms was even more critical due to this rapid expansion. However, there was a lack of experience in providing the necessary SARS-CoV-2 EQA materials, especially in locations with constrained resources. OBJECTIVE: We aimed to create a PT (Proficiency testing) programme based on the Dried Tube Specimens (DTS) method that would be a practical option for molecular based SARS-CoV-2 EQA in Low- and Middle-Income Countries. METHODS: Based on previous ISO/IEC 17043:2010 accreditation experiences and with assistance from the US Centers for Disease Control and Prevention, The Supranational Reference Laboratory of Uganda (adapted the DTS sample preparation method and completed a pilot EQA program between 2020 and 2021. Stability and panel validation testing was conducted on the designed materials before shipping to pilot participants in six African countries. Participants received a panel containing five SARS-CoV-2 DTS samples, transported at ambient conditions. Results submitted by participants were compared to validation results. Participants were graded as satisfactory (≥ 80%) or unsatisfactory (< 80%) and performance reports disseminated. RESULTS: Our SARS-CoV-2 stability experiments showed that SARS-CoV-2 RNA was stable (-15 to -25 °C, 4 to 8 °C, (18 to 28 °C) room temperature and 35 to 38 °C) as well as DTS panels (4 to 8 °C, 18 to 28 °C, 35 to 38 °C and 45 °C) for a period of 4 weeks. The SARS-CoV-2 DTS panels were successfully piloted in 35 test sites from Zambia, Malawi, Mozambique, Nigeria, and Seychelles. The pilot results of the participants showed good accuracy, with an average of 86% (30/35) concordance with the original SARS CoV-2 expectations. CONCLUSION: The SARS-CoV-2 DTS PT panel is reliable, stable at ambient temperature, simple to prepare and requires minimal resources.


Asunto(s)
COVID-19 , Países en Desarrollo , Ensayos de Aptitud de Laboratorios , SARS-CoV-2 , Manejo de Especímenes , Humanos , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Manejo de Especímenes/métodos , Manejo de Especímenes/normas , Prueba de COVID-19/métodos , Uganda , Proyectos Piloto
19.
Ann Lab Med ; 44(6): 529-536, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-38919008

RESUMEN

Background: In recent decades, the analytical quality of clinical laboratory results has substantially increased because of collaborative efforts. To effectively utilize laboratory results in applications, such as machine learning through big data, understanding the level of harmonization for each test would be beneficial. We aimed to develop a quantitative harmonization index that reflects the harmonization status of real-world laboratory tests. Methods: We collected 2021-2022 external quality assessment (EQA) results for eight tests (HbA1c, creatinine, total cholesterol, HDL-cholesterol, triglyceride, alpha-fetoprotein [AFP], carcinoembryonic antigen [CEA], and prostate-specific antigen [PSA]). This EQA was conducted by the Korean Association of External Quality Assessment Service, using commutable materials. The total analytical error of each test was determined according to the bias% and CV% within peer groups. The values were divided by the total allowable error from biological variation (minimum, desirable, and optimal) to establish a real-world harmonization index (RWHI) at each level (minimum, desirable, and optimal). Good harmonization was arbitrarily defined as an RWHI value ≤ 1 for the three levels. Results: Total cholesterol, triglyceride, and CEA had an optimal RWHI of ≤ 1, indicating an optimal harmonization level. Tests with a desirable harmonization level included HDL-cholesterol, AFP, and PSA. Creatinine had a minimum harmonization level, and HbA1c did not reach the minimum harmonization level. Conclusions: We developed a quantitative RWHI using regional EQA data. This index may help reflect the actual harmonization level of laboratory tests in the field.


Asunto(s)
Creatinina , Hemoglobina Glucada , Antígeno Prostático Específico , Triglicéridos , Humanos , Antígeno Prostático Específico/sangre , Antígeno Prostático Específico/normas , Antígeno Prostático Específico/análisis , Hemoglobina Glucada/análisis , Hemoglobina Glucada/normas , Triglicéridos/sangre , Triglicéridos/normas , Creatinina/sangre , Antígeno Carcinoembrionario/sangre , Colesterol/sangre , Colesterol/análisis , alfa-Fetoproteínas/análisis , Control de Calidad , HDL-Colesterol/sangre , Garantía de la Calidad de Atención de Salud , Técnicas de Laboratorio Clínico/normas
20.
J Eval Clin Pract ; 30(6): 1034-1038, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38778586

RESUMEN

PURPOSE: To innovatively use the FOCUS-PDCA quality improvement strategy to establish an external quality assessment (EQA) working group to continuously improve EQA performance, an important indicator of the national tertiary public hospital performance appraisal. METHODS: The project was carried out at the National Center for Clinical Laboratories. Using FOCUS-PDCA, which combines problem-focused steps (FOCUS) and improvement steps (PDCA), a project team was established to carry out improvement work. Root cause analysis was carried out to analyze the problems in quality control from EQA project application to results analysis and an improvement plan was implemented according to the steps of FOCUS-PDCA. The project was executed in three cycles from 2019 to 2021 to obtain more satisfactory results. RESULTS: After implementing three cycles of FOCUS-PDCA, the EQA participation rate increased from 66.5% in 2018 to 100% in 2021, and the EQA pass rate increased from 94.9% in 2018 to 99.3% in 2021. Consequently, the hospital moved into the top 50 in performance assessment for the first time in 2020 and ranked 27th in 2021. CONCLUSION: The use of the FOCUS-PDCA quality improvement strategy can improve the EQA performance of national tertiary public hospitals and help them achieve satisfactory results in the national examination.


Asunto(s)
Hospitales Públicos , Mejoramiento de la Calidad , Centros de Atención Terciaria , Mejoramiento de la Calidad/organización & administración , Hospitales Públicos/normas , Humanos , Centros de Atención Terciaria/normas , Centros de Atención Terciaria/organización & administración , Garantía de la Calidad de Atención de Salud/métodos , Garantía de la Calidad de Atención de Salud/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA