Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 213: 288-300, 2019 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-30708286

RESUMEN

Novel univariate and multivariate factor-based calibration-prediction techniques were validated for simultaneous ultraviolet spectrophotometric determination of ribavirin (RIV), daclatasvir (DAV), sofosbuvir (SOV), and sorafenib (SON) which are co-administered for treatment of hepatocellular carcinoma (HCC) that results from Hepatitis C-virus (HCV) infection in their commercial products and in biological fluids. Determination of these compounds is essential owing to their pharmacotherapeutic benefits. Due to spectral overlapping of RIV, DAV, SOV, and SON, univariate extended derivative ratio (EDR) method and multivariate partial least-squares (PLS) and principal component regression (PCR) methods were used for constructing the calibration curves. The extended derivative ratio (EDR) absorption maxima at 215 nm and minima at 310.5 nm was used for determination of RIV and DAV, respectively and absorption maxima at 240.3 nm and minima at 284.5 nm for determination of SOV and SON, respectively. The linearity was established over the range of 6-42 µg mL-1, 4-16 µg mL-1, 10-70 µg mL-1, and 3-9 µg mL-1 for RIV, DAV, SOV and SON with correlation coefficient (r2) of 0.9997, 0.9997, 0.9999 and 0.9997, respectively. This method was effectively applied to pure, pharmaceutical preparations and to spiked human urine and plasma. PLS and PCR models were established for the determination of the studied drugs in the range of 6-42, 4-16, 10-70 and 3-9 µg mL-1 for RIV, DAV, SOV, and SON, respectively. Furthermore, updating the PLS model (PLS model update) were allowed for the determination of these drugs in spiked human urine, plasma and drug-dissolution test of their tablets. The obtained results were compared to official and reported method showing that there were no significant differences. The results of applying PLS and PCR models for evaluation of RIV, DAV, SOV, and SON in human urine samples as real samples were also encouraging. It is expected that the suitable features of the proposed method make it helpful for biological and clinical applications.


Asunto(s)
Antivirales/sangre , Antivirales/orina , Carcinoma Hepatocelular/tratamiento farmacológico , Hepacivirus/fisiología , Neoplasias Hepáticas/tratamiento farmacológico , Espectrofotometría/métodos , Antivirales/química , Calibración , Humanos , Análisis de los Mínimos Cuadrados , Límite de Detección , Análisis Multivariante , Análisis de Componente Principal , Reproducibilidad de los Resultados , Comprimidos
2.
Artículo en Inglés | MEDLINE | ID: mdl-26709018

RESUMEN

New accurate, sensitive and selective spectrophotometric and chemometric methods were developed and subsequently validated for determination of Imipenem (IMP), ciprofloxacin hydrochloride (CIPRO), dexamethasone sodium phosphate (DEX), paracetamol (PAR) and cilastatin sodium (CIL) in human urine. These methods include a new derivative ratio method, namely extended derivative ratio (EDR), principal component regression (PCR) and partial least-squares (PLS) methods. A novel EDR method was developed for the determination of these drugs, where each component in the mixture was determined by using a mixture of the other four components as divisor. Peak amplitudes were recorded at 293.0 nm, 284.0 nm, 276.0 nm, 257.0 nm and 221.0 nm within linear concentration ranges 3.00-45.00, 1.00-15.00, 4.00-40.00, 1.50-25.00 and 4.00-50.00 µg mL(-1) for IMP, CIPRO, DEX, PAR and CIL, respectively. PCR and PLS-2 models were established for simultaneous determination of the studied drugs in the range of 3.00-15.00, 1.00-13.00, 4.00-12.00, 1.50-9.50, and 4.00-12.00 µg mL(-1) for IMP, CIPRO, DEX, PAR and CIL, respectively, by using eighteen mixtures as calibration set and seven mixtures as validation set. The suggested methods were validated according to the International Conference of Harmonization (ICH) guidelines and the results revealed that they were accurate, precise and reproducible. The obtained results were statistically compared with those of the published methods and there was no significant difference.


Asunto(s)
Acetaminofén/orina , Analgésicos no Narcóticos/orina , Antibacterianos/orina , Antiinflamatorios/orina , Ciprofloxacina/orina , Dexametasona/análogos & derivados , Imipenem/orina , Dexametasona/orina , Humanos , Análisis de los Mínimos Cuadrados , Límite de Detección , Análisis Multivariante , Análisis de Componente Principal , Espectrofotometría Ultravioleta/métodos
3.
Spectrochim Acta A Mol Biomol Spectrosc ; 133: 119-29, 2014 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-24934969

RESUMEN

A modified dispersive liquid-liquid extraction (DLLE) procedure coupled with spectrophotometric techniques was adopted for simultaneous determination of naphthalene, anthracene, benzo(a)pyrene, alpha-naphthol and beta-naphthol in water samples. Two different methods were used, partial least-squares (PLS) method and a new derivative ratio method, namely extended derivative ratio (EDR). A PLS-2 model was established for simultaneous determination of the studied pollutants in methanol, by using twenty mixtures as calibration set and five mixtures as validation set. Also, in methanol a novel (EDR) method was developed for determination of the studied pollutants, where each component in the mixture of the five PAHs was determined by using a mixture of the other four components as divisor. Chemometric and EDR methods could be also adopted for determination of the studied PAH in water samples after transferring them from aqueous medium to the organic one by utilizing dispersive liquid-liquid extraction technique, where different parameters were investigated using a full factorial design. Both methods were compared and the proposed method was validated according to ICH guidelines and successfully applied to determine these PAHs simultaneously in spiked water samples, where satisfactory results were obtained. All the results obtained agreed with those of published methods, where no significant difference was observed.


Asunto(s)
Extracción Líquido-Líquido/métodos , Hidrocarburos Policíclicos Aromáticos/análisis , Espectrofotometría/métodos , Contaminantes Químicos del Agua/análisis , Calibración , Análisis de los Mínimos Cuadrados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA