Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 547
Filtrar
1.
Front Nutr ; 11: 1439287, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39234291

RESUMEN

Background: 3-caffeoylquinic acid (3-CQA), a member of the chlorogenic acid family, possesses diverse pharmacological properties, such as scavenging, antioxidant, and antiapoptotic activity, rendering substantial value to alimentary consumables and therapeutic substances. However, the pervasiveness of non-standard practices, notably the misuse and abuse of indigenous botanicals, coupled with the inherent susceptibility of 3-CQA to degradation under light and heat exposure, engenders discernible disparateness in the quality profiles of the same kinds of herbs. Consequently, precise quantification of 3-CQA becomes imperative. Methods: In this context, an artificial antigen was synthesized as a specific conjugate of 3-CQA and bovine serum albumin (3-CQA-BSA), followed by the generation of a monoclonal antibody (mAb) against the conjugate. Through optimization, a mAb-based indirect competitive chemiluminescence enzyme immunoassay (ic-CLEIA) was developed. Results: It demonstrated an IC50 and the calibration range of 2.97 ng/mL and 0.64-13.75 ng/mL, respectively, outperforming the conventional enzyme-linked immunosorbent assay (ELISA). Notably, the ic-CLEIA displayed 10.71% cross-reactivity with 3,5-dicaffeoylquinic acid, alongside minimal cross-reactivity toward other isomeric counterparts and analogs. Validation experiments on herbs and Chinese patent medicines using ic-CLEIA, confirmed by high-performance liquid chromatography (HPLC) analysis, revealed a robust correlation coefficient of 0.9667 between the two modalities. Conclusion: These findings unequivocally demonstrated that the proposed ic-CLEIA represents a viable and reliable analytical method for 3-CQA determination. This method holds significant potential for ensuring the quality control and therapeutic efficacy germane to herbs and patent medicines, spanning diverse therapeutic milieus and applications.

2.
Vaccine X ; 20: 100548, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39247133

RESUMEN

Background: Assessing the risk of measles outbreaks and identifying the susceptible parts of the population is essential to timely intervention. Infants between 6-12 months are increasingly susceptible to measles but evaluating the performance of high throughput enzyme immunoassays (ELISAs) in infants < 9 months of age is lacking. Methods: A commercially available ELISA kit (Creative Diagnostics, DEIA359) for estimating measles seroprotection was evaluated in infants 5-7 months of age. In an immunogenicity substudy in the Danish MMR trial conducted between 2019-2021, infants (and mothers at baseline) were sampled before and one month after measles-mumps-rubella vaccination (MMR) or placebo as well as one month after routine MMR at 15 months. Measles IgG ELISA was compared to the gold standard but labor-intensive measles plaque reduction neutralization test (PRNT) by Pearson and Spearman correlations and by estimating sensitivity, specificity, and positive and negative predictive values (PPV and NPV). Findings: Measles IgG levels compared to PRNT antibodies had a Pearson's correlation coefficient between 0.10-0.24. Seroprotection rates measured by ELISA in young infants were 10-14% lower than measured by PRNT. The sensitivity of the ELISA to detect serological protection compared to PRNT in the infant population differed markedly across sampling time points and was 14%, 40%, and 92% at baseline, post-intervention, and post-routine MMR, whereas the specificity was 99%, 93%, and 43%, respectively. The PPV and NPV were 68% and 87% in infants at baseline. Interpretation: The correlation between measles IgG and PRNT antibodies was low. Seroprotection was underestimated using ELISA. High-accuracy tests are needed to avoid misclassifications and practices that lead to primary or secondary vaccine failure or retention of vaccination in outbreak settings. Baseline PPV and NPV suggested some applicability of ELISA in predicting serological protection in this age group. However, PRNT may be the only accurate estimator of serological protection in young infants.

3.
Heliyon ; 10(16): e36614, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39262946

RESUMEN

The fluorescent antibody to membrane antigen (FAMA) test is the gold standard for measuring the immunity induced by varicella vaccines with high sensitivity and specificity. However, certain aspects of the FAMA test, such as time consumption, non-automation, and subjective interpretation by observers using fluorescence microscopy, are obstacles to handling large amounts of samples. To overcome these hurdles, flow cytometry was adopted to analyze and compare the flow FAMA titer with the classic FAMA titer. In addition, to save time in FAMA antigen preparation and reduce lot-to-lot variation, the stability of the FAMA antigen stored in liquid nitrogen was investigated. The FAMA test was performed on sera from 229 children, and antibody titers were analyzed using fluorescence microscopy (classic FAMA) and flow cytometry (flow FAMA). For comparison, glycoprotein enzyme immunoassay (gpEIA) titer was also measured. A strong correlation was found between the flow and classic FAMA titers, and the flow FAMA and gpEIA titers, with Pearson's r of 0.9316 and 0.8588, respectively. Between the classic FAMA and gpEIA titers, the Pearson's r value was 0.8156. The positive percent agreement, negative percent agreement, and area under the curve of the flow FAMA against classic FAMA were 95.0 %, 86.8 %, and 0.909, respectively. And those of the flow FAMA against gpEIA were 80.0 %, 87.6 %, and 0.838, respectively. The FAMA antigen stored in liquid nitrogen was stable for up to 12 months. Based on the above data, flow FAMA has the potential to be used as an alternative to classic FAMA. Moreover, pre-made FAMA antigen may reduce the preparation time and lot-to-lot variation of FAMA test.

4.
Aust Vet J ; 102(9): 485-488, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39009475

RESUMEN

The eastern small eyed snake (Cryptophis nigrescens; CN) is an uncommon cause of snakebite in Australia despite the widespread distribution of the snake along the east coast of Australia. Diagnosis of envenomation relies on identification of the snake which is often not possible with animal snakebite cases. This study examined the immunoreactivity profile of CN venom towards specific rabbit IgG made against the medically relevant snake venom immunotypes found in Australia (tiger, brown, black, death adder and taipan). A simultaneous sandwich ELISA format was used to quantify CN venom binding to venom specific Protein A purified rabbit IgG. The binding profiles demonstrated weak binding of CN venom to rabbit IgG made against both tiger (N. scutatus) and black snake (P. australis) venoms with approximately 0.19% and 0.069% cross reactivity, respectively. However, the concentration of venom likely to be present in the urine of CN envenomed patients and the low cross reactivity suggest that envenomed veterinary patients are unlikely to be detected in the commercial snake venom detection kit. It is possible that CN envenomation is more common but may be underdiagnosed where snake venom antigen detection is relied upon solely. Serum biochemical abnormalities also overlap with other snake species found in the same geographical area. In respect of antivenom therapy, administration of tiger snake antivenom is supported by the binding data, but due to the low cross reactivity multiple vials may be required. Limited clinical evidence also supports the efficacy of tiger snake antivenom for envenomation by CN.


Asunto(s)
Antivenenos , Venenos Elapídicos , Elapidae , Ensayo de Inmunoadsorción Enzimática , Mordeduras de Serpientes , Animales , Venenos Elapídicos/inmunología , Mordeduras de Serpientes/veterinaria , Mordeduras de Serpientes/inmunología , Ensayo de Inmunoadsorción Enzimática/veterinaria , Australia , Antivenenos/inmunología , Antivenenos/uso terapéutico , Conejos , Especificidad de la Especie , Reacciones Cruzadas , Inmunoglobulina G/sangre
5.
Braz J Infect Dis ; 28(4): 103838, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39009082

RESUMEN

Aspergillus species can colonize and infect immunocompetent and immunocompromised hosts. Conventional fungal identification depends on microscopic analysis and microorganism medium growth. Other diagnostic methods, non-growth dependent, to invasive fungal infections, are the biomarkers that detect circulating polysaccharides, for example, 1-3-ß-d-Glucan and galactomannan. Both are polysaccharides present on the external layer of fungi cell wall and can be detected in clinical samples during the growth of the fungus in the patient. This study aimed to compare the galactomannan detection of Lateral Flow Assay and Enzyme Immunoassay methods in Bronchoalveolar Lavage Fluid. The galactomannan antigen in Bronchoalveolar Lavage Fluid was measured using Enzyme Immunoassay according to the manufacturer's instructions (PLATELIA ASPERGILLUS™ BioRad) and, using a Lateral Flow Assay according to the manufacturer's instructions (Galactomannan LFA IMMY©). The 71 samples were Bronchoalveolar Lavage Fluid of patients hospitalized at Unicamp Clinical Hospital between 2019 and 2021; of these samples 12/71 (16.9 %) resulted in positive Galactomannan-Lateral Flow Assay. In contrast, Galactomannan-Enzyme Immunoassay resulted as positive in 9/71 (12.6 %) samples, a difference that showed not significant statistically (p-value = 0.36) Comparing both assays' results identified 8 divergences between them, about 11 % of the total sample. The Sensitivity (73.3 %), Specificity (92.35 %), Positive Predictive Value (62.85 %) and Negative Predictive Value (95.15 %) of Lateral Flow Assay were calculated using the Galactomannan Enzyme Immunoassay as standard. The Lateral Flow Assay demonstrated good results when compared with the Enzyme Immunoassay.


Asunto(s)
Aspergillus , Líquido del Lavado Bronquioalveolar , Galactosa , Técnicas para Inmunoenzimas , Mananos , Sensibilidad y Especificidad , Mananos/análisis , Galactosa/análogos & derivados , Humanos , Líquido del Lavado Bronquioalveolar/microbiología , Líquido del Lavado Bronquioalveolar/química , Aspergillus/inmunología , Aspergillus/aislamiento & purificación , Técnicas para Inmunoenzimas/métodos , Aspergilosis/diagnóstico , Aspergilosis/microbiología , Biomarcadores/análisis , Antígenos Fúngicos/análisis , Reproducibilidad de los Resultados
6.
Diagnostics (Basel) ; 14(14)2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39061657

RESUMEN

BACKGROUND: Recently, the investigation of cerebrospinal fluid (CSF) biomarkers for diagnosing human prion diseases (HPD) has garnered significant attention. Reproducibility and accuracy are paramount in biomarker research, particularly in the measurement of total tau (T-tau) protein, which is a crucial diagnostic marker. Given the global impact of the coronavirus disease pandemic, the frequency of measuring this protein using one of the world's fully automated assays, chemiluminescent enzyme immunoassay (CLEA), has increased. At present, the diagnosis and monitoring of neurological diseases mainly rely on traditional methods, but their accuracy and responsiveness are limited. There is limited knowledge of the accuracy of CLEA in tau measurements. We aimed to measure T-tau protein using CLEA and to elucidate its merits and limitations. METHODS: We randomly selected 60 patients with rapidly progressive dementia, using ELISA and CLEA analysis of cerebrospinal fluid specimens. Additionally, we used Western blotting to detect the presence of 14-3-3 protein and employed real-time quaking-induced conversion (RT-QuIC) assays to analyze the same set of samples. Furthermore, we examined the correlation coefficient between ELISA and CLEA results in a subset of 60 samples. Moreover, using CLEA, we evaluated the diurnal reproducibility, storage stability, dilutability, and freeze-thaw effects in three selected samples. RESULTS: In 172 patients, 172 samples were extracted, with each patient providing only one sample, and a total of 88 (35 men and 53 women) tested positive for HPD in the RT-QuIC assay. In contrast, all CSF samples from the remaining 84 patients without HPD (50 men and 34 women) tested negative in the RT-QuIC assay. Both ELISA and CLEA showed perfect sensitivity and specificity (100%) in measuring T-tau protein levels. In addition, ELISA and CLEA are similar in terms of measurement sensitivity and marginal effect of detection extrema. CLEA analysis exhibited instability for certain samples with T-tau protein levels exceeding 2000 pg/mL, leading to low reproducibility during dilution analysis. CONCLUSIONS: Our findings indicate that CLEA outperforms ELISA in terms of diurnal reproducibility, storage stability, and freeze-thaw effects. However, ELISA demonstrated superior performance in the dilution assay. Therefore, it is imperative to develop innovative approaches for the dilution of biomarker samples for CLEA measurements during clinical trials.

7.
Vopr Virusol ; 69(3): 285-289, 2024 Jul 05.
Artículo en Ruso | MEDLINE | ID: mdl-38996377

RESUMEN

INTRODUCTION: Hemorrhagic fever with renal syndrome (HFRS) is the most common zoonotic human viral disease in the Russian Federation. More than 98% of the HFRS cases are caused by Puumala orthohantavirus (PUU). Effective serological tests are required for laboratory diagnosis of HFRS. OBJECTIVE: Construction of an enzyme immunoassay (ELISA) test system for detection of specific antibodies using standard antigen in the form of highly purified inactivated PUU virus as immunosorbent. MATERIALS AND METHODS: Preparation of PUU virus antigen, designing the ELISA for detection of specific antibodies, developing parameters of the ELISA system, parallel titration of HFRS patients sera by fluorescent antibody technique (FAT) and the new ELISA. RESULTS AND DISCUSSION: For the first time, ELISA based on purified inactivated PUU virus as standard antigen directly absorbed onto immunoplate was developed. Parallel titration of 50 samples from HFRS patients blood sera using FAT and the developed ELISA showed high sensitivity and specificity of this ELISA, with 100% concordance of testing results and significant level of correlation between the titers of specific antibodies in the two assays. CONCLUSION: The ELISA based on purified inactivated PUU virus as an immunosorbent can be effectively used for HFRS serological diagnosis and for mass seroepidemiological studies.


Asunto(s)
Anticuerpos Antivirales , Antígenos Virales , Ensayo de Inmunoadsorción Enzimática , Fiebre Hemorrágica con Síndrome Renal , Virus Puumala , Sensibilidad y Especificidad , Fiebre Hemorrágica con Síndrome Renal/diagnóstico , Fiebre Hemorrágica con Síndrome Renal/sangre , Fiebre Hemorrágica con Síndrome Renal/inmunología , Fiebre Hemorrágica con Síndrome Renal/virología , Humanos , Virus Puumala/inmunología , Virus Puumala/aislamiento & purificación , Anticuerpos Antivirales/sangre , Ensayo de Inmunoadsorción Enzimática/métodos , Antígenos Virales/inmunología , Antígenos Virales/sangre , Animales
8.
Artículo en Inglés | MEDLINE | ID: mdl-39042601

RESUMEN

Background: Borrelia burgdorferi sensu stricto is the causative agent of Lyme disease (LD). Possible early symptoms include flu-like symptoms and erythema migrans and later, the risk of disruption of the nervous system, joints, and heart. A two-tiered testing method is employed for serological diagnostics. The Public Health Agency of Canada guidelines recommend that samples tested negative on first-tiered test need not be confirmed by second-tiered test. Due to the challenging nature of diagnosis leading to misconceptions among physicians about false negatives, confirmatory testing is requested despite the initial negative result. Methods: Hundred screen-negative Lyme patient samples from 2007 to 2016 were tested by Western blot (WB) second-tiered confirmatory test upon physician's request in British Columbia to study the first-tiered screening test sufficiency. Results: Those negative for first-tiered enzyme-linked immunosorbent assay were also negative by WB. Conclusion: Results demonstrate that confirmatory testing is not necessary on screen-negative samples. Hence, first-tiered test is sufficient to rule out LD.

9.
Endocr J ; 71(9): 895-906, 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-38910122

RESUMEN

In Japan, the traditional method for measuring plasma aldosterone concentration (PAC) was radioimmunoassay (RIA), which had several challenges, including poor traceability of certified reference materials and reduced detection sensitivity at low concentrations. To overcome these issues, a chemiluminescent enzyme immunoassay (CLEIA) for PAC measurement was introduced in April 2021 and the Japan Endocrine Society published new guidelines for primary aldosteronism (PA). This study aimed to evaluate the impact of the transition from RIA to CLEIA for PAC measurement on PA diagnosis. Data from 190 patients admitted to the Second Department of Internal Medicine, University of the Ryukyus Hospital, between April 2012 and March 2021 were analyzed. Patients who were diagnosed with PA underwent adrenal venous sampling. The PAC measured by RIA (PAC(RIA)) was converted to the estimated PAC measured by CLEIA (ePAC(CLEIA)) using a conversion formula. The present study evaluated the discordance rates in diagnoses based on screening (SC), captopril challenge test (CCT), saline infusion test (SIT), and diagnosis of PA between results judged by PAC(RIA) according to the previous guidelines and those judged by ePAC(CLEIA) according to the new guidelines. The results revealed discordant diagnosis rates of 6.4% for SC and 10.1% for CCT, with no discordance for SIT. The discordant diagnosis rate for PA was 3.7%. Our study reveals the challenges in establishing appropriate diagnostic criteria for PA using PAC(CLEIA) and highlights the demand for further research on provisionally positive categories.


Asunto(s)
Aldosterona , Hiperaldosteronismo , Técnicas para Inmunoenzimas , Radioinmunoensayo , Humanos , Hiperaldosteronismo/diagnóstico , Hiperaldosteronismo/sangre , Aldosterona/sangre , Japón , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Radioinmunoensayo/métodos , Radioinmunoensayo/normas , Masculino , Anciano , Técnicas para Inmunoenzimas/métodos , Técnicas para Inmunoenzimas/normas , Adulto , Mediciones Luminiscentes/métodos
10.
Conserv Physiol ; 12(1): coae035, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38840751

RESUMEN

Animals face several challenges in their natural environment, and to cope with such conditions, they may exhibit contrasting physiological responses that directly affect their overall well-being and survival. In this study, we assessed physiological responses via faecal glucocorticoid metabolite (fGCM) measurements in free-ranging mugger crocodiles inhabiting diverse habitats in Gujarat, India. We sampled muggers within Charotar, a rural area (Zone A) with local people having high tolerance towards the presence of muggers, and Vadodara, a region having both urban (Zone B) and rural (Zone C) areas with high levels of human-mugger conflict (HMC). Further, muggers in Vadodara live in water bodies that are mostly polluted due to sewage disposal from adjoining chemical industries. To measure fGCM (mean ± SEM, ng/g dry faeces) levels in muggers, scats were collected during both breeding (N = 107 scats) and non-breeding (N = 22 scats) seasons from all three zones. We used captive muggers (a focal enclosure) to biologically validate (via capture and restraint) the selected fGCM assay (11-oxoetiocholanolone assay). We showed a significant (P < 0.05) 11-fold increase in fGCM levels between pre-capture (540.9 ± 149.2, N = 11) and post-capture (6259.7 ± 1150.5, N = 11) samples. The validated assay was applied to free-ranging muggers during the breeding season, and Zone A showed significantly (P < 0.05) lower fGCM levels (542.03 ± 71.3) compared to muggers of Zone B (1699.9 ± 180.8) and Zone C (1806.4 ± 243.2), both zones having high levels of HMC with polluted water bodies. A similar contrast in fGCM levels was also observed during the non-breeding season. Overall, the study demonstrated that fGCM levels in muggers varied across habitats, and such variation could be due to a multitude of ecological factors that the species experience in their immediate local environment. Moreover, high fGCM levels in muggers of Vadodara during both breeding and non-breeding seasons may indicate a condition of chronic stress, which could be maladaptive for the species.

11.
Lab Med ; 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38801239

RESUMEN

OBJECTIVE: In evaluation of systemic lupus erythematosus (SLE), anti-double-stranded DNA antibodies (anti-dsDNA) play a significant role in diagnosis, monitoring SLE activity, and assessing prognosis. However, evaluations of the performance and limitations for recently developed methods for anti-dsDNA assessment are sparse. METHODS: Specimens used for antinuclear antibody testing (n = 129) were evaluated for anti-dsDNA assay comparability across 4 medical centers in the United States. The methods compared were Werfen Quanta Lite dsDNA, Zeus Scientific dsDNA Enzyme Immunoassay, Bio-Rad multiplex immunoassay (MIA) dsDNA, ImmunoConcepts Crithidia, and Bio-Rad Laboratories Crithidia. RESULTS: For quantitative anti-dsDNA measurements, Spearman's correlation coefficient was highest between Zeus and Werfen (ρ = 0.86; CI, 0.81-0.90; P < .0001). Comparison of MIA to Werfen or Zeus yielded similar results to each other (ρ = 0.58; CI, 0.44-0.68; P < .0001; and ρ = 0.59; CI, 0.46-0.69; P < .0001, respectively), but lower than the correlation between Zeus and Werfen. Positive concordance between assays ranged from 31.4% to 97.1%, and negative concordance between assays ranged from 58.5% to 100%. The detection of anti-dsDNA in those with SLE diagnosis ranged from 50.9% to 77.4% for quantitative assays and 15.1% to 24.5% for Crithidia assays. CONCLUSION: Current quantitative anti-dsDNA assays are not interchangeable for patient follow-up. Crithidia-based assays demonstrate high negative concordance and lack positive concordance among the methods.

12.
Int J Mol Sci ; 25(10)2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38791367

RESUMEN

The pathogenicity of many bacteria, including Bacillus cereus and Staphylococcus aureus, depends on pore-forming toxins (PFTs), which cause the lysis of host cells by forming pores in the membranes of eukaryotic cells. Bioinformatic analysis revealed a region homologous to the Lys171-Gly250 sequence in hemolysin II (HlyII) from B. cereus in over 600 PFTs, which we designated as a "homologous peptide". Three ß-barrel PFTs were used for a detailed comparative analysis. Two of them-HlyII and cytotoxin K2 (CytK2)-are synthesized in Bacillus cereus sensu lato; the third, S. aureus α-toxin (Hla), is the most investigated representative of the family. Protein modeling showed certain amino acids of the homologous peptide to be located on the surface of the monomeric forms of these ß-barrel PFTs. We obtained monoclonal antibodies against both a cloned homologous peptide and a 14-membered synthetic peptide, DSFNTFYGNQLFMK, as part of the homologous peptide. The HlyII, CytK2, and Hla regions recognized by the obtained antibodies, as well as an antibody capable of suppressing the hemolytic activity of CytK2, were identified in the course of this work. Antibodies capable of recognizing PFTs of various origins can be useful tools for both identification and suppression of the cytolytic activity of PFTs.


Asunto(s)
Bacillus cereus , Toxinas Bacterianas , Proteínas Hemolisinas , Staphylococcus aureus , Toxinas Bacterianas/química , Toxinas Bacterianas/metabolismo , Bacillus cereus/metabolismo , Proteínas Hemolisinas/química , Proteínas Hemolisinas/metabolismo , Staphylococcus aureus/metabolismo , Secuencia de Aminoácidos , Hemólisis , Proteínas Citotóxicas Formadoras de Poros/química , Proteínas Citotóxicas Formadoras de Poros/metabolismo , Modelos Moleculares , Animales , Anticuerpos Monoclonales/química , Humanos , Proteínas Bacterianas/química , Proteínas Bacterianas/metabolismo
13.
Open Forum Infect Dis ; 11(5): ofae244, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38756762

RESUMEN

Background: Multistep laboratory testing is recommended for the diagnosis of Clostridioides difficile infection (CDI). The aim of this study was to present the impact of multistep CDI diagnostic testing in an academic hospital system and evaluate the toxin B gene polymerase chain reaction (PCR) cycle threshold (Ct) values of PCR-positive tests. Methods: In October 2022, our system began reflex testing all PCR-positive stool samples with the C. DIFF QUIK CHEK COMPLETE (Techlab), an enzyme immunoassay-based test with results for the glutamate dehydrogenase antigen (GDH) and C difficile toxin A/B. Hospital-onset (HO) CDI and CDI antibiotic use before and after testing were tracked. Ct values were obtained from the Infectious Diseases Diagnostic Laboratory. Receiver operating curve analysis was used to examine the sensitivity and specificity for identifying GDH+/toxin+ and GDH-/toxin- at various Ct thresholds. Results: The HO-CDI rate decreased from 0.352 cases per 1000 patient-days to 0.115 cases per 1000 patient-days post-reflex testing (P < .005). Anti-CDI antibiotics use decreased, but the decrease was not commensurate with CDI rates following reflex testing. PCR+/GDH+/toxin+ samples had a lower mean Ct value than PCR+/GDH-/toxin- samples (23.3 vs 33.5, P < .0001). A Ct value of 28.65 could distinguish between those 2 groups. Fifty-four percent of PCR+/GDH+/toxin- samples had a Ct value below that cut-off, suggesting the possibility of CDI with a negative toxin test. Conclusions: Reflex testing for a laboratory diagnosis of CDI results in rapid, systemwide decreases in the rate of HO-CDI. Additional research is needed to distinguish CDI from C difficile colonization in patients with discordant testing.

14.
J Fungi (Basel) ; 10(5)2024 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-38786677

RESUMEN

Coccidiomycosis is a potentially life-threatening fungal infection endemic to certain regions of Argentina. The infection is caused by Coccidioides spp. and is primarily diagnosed by Coccidioides antibody (Ab) detection. Access to rapid, highly accurate diagnostic testing is critical to ensure prompt antifungal therapy. The sona Coccidioides Ab Lateral Flow Assay (LFA) performs faster and requires less laboratory infrastructure and equipment compared with other Ab detection assays, potentially providing a substantial improvement for rapid case screening in coccidioidomycosis-endemic regions; however, validation of this test is needed. Thus, we aimed to evaluate the analytical performance of the sona Coccidioides Ab (LFA) and compare agreement with anti-Coccidioides Ab detection assays. A total of 103 human sera specimens were tested, including 25 specimens from patients with coccidioidomycosis and 78 from patients without coccidioidomycosis. The sona Coccidioides Ab Lateral Flow Assay (LFA) was performed with a sensitivity of 88%, and specificity and accuracy of 87%. Furthermore, the Coccidioides Ab LFA had good agreement with other anti-Coccidioides Ab detection assays. Our findings suggest the sona Coccidioides Ab LFA has satisfactory performance and may be useful for diagnosing coccidioidomycosis in endemic regions.

15.
J Alzheimers Dis ; 99(3): 1077-1092, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38759016

RESUMEN

Background: Although Lumipulse assays and conventional ELISA are strongly correlated, the precise relationship between their measured values remains undetermined. Objective: To determine the relationship between Lumipulse and ELISA measurement values. Methods: Patients who underwent cerebrospinal fluid (CSF) Alzheimer's disease (AD) biomarker measurements and consented to biobanking between December 2021 and June 2023 were included. The relationship between values measured via Lumipulse assays and conventional ELISA were evaluated by Passing-Bablok analyses for amyloid-ß 1-42 (Aß42), total tau (t-tau), and phospho-tau 181 (p-tau 181). Studies using both assays were systematically searched for in PubMed and summarized after quality assessment. Results: Regression line slopes and intercepts were 1.41 (1.23 to 1.60) and -77.8 (-198.4 to 44.5) for Aß42, 0.94 (0.88 to 1.01) and 98.2 (76.9 to 114.4) for t-tau, and 1.60 (1.43 to 1.75) and -21.1 (-26.9 to -15.6) for p-tau181. Spearman's correlation coefficients were 0.90, 0.95, and 0.95 for Aß42, t-tau, and p-tau181, respectively. We identified 13 other studies that included 2,117 patients in total. Aß42 slope varied among studies, suggesting inter-lab difference of ELISA. The slope and intercept of t-tau were approximately 1 and 0, respectively, suggesting small proportional and systematic differences. Conversely, the p-tau181 slope was significantly higher than 1, distributed between 1.5-2 in most studies, with intercepts significantly lower than 0, suggesting proportional and systematic differences. Conclusions: We characterized different relationship between measurement values for each biomarker, which may be useful for understanding the differences in CSF biomarker measurement values on different platforms and for future global harmonization.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Biomarcadores , Ensayo de Inmunoadsorción Enzimática , Fragmentos de Péptidos , Proteínas tau , Enfermedad de Alzheimer/líquido cefalorraquídeo , Enfermedad de Alzheimer/diagnóstico , Humanos , Biomarcadores/líquido cefalorraquídeo , Péptidos beta-Amiloides/líquido cefalorraquídeo , Ensayo de Inmunoadsorción Enzimática/métodos , Proteínas tau/líquido cefalorraquídeo , Fragmentos de Péptidos/líquido cefalorraquídeo
17.
Ann Clin Microbiol Antimicrob ; 23(1): 35, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38664689

RESUMEN

PURPOSE: The clinical significance of negative toxin enzyme immunoassays (EIA) for Clostridioides difficile infections (CDIs) is unclear. Our study aimed to investigate the significance of toxin EIA-negative in the diagnosis and prognosis of CDI. METHODS: All stool specimens submitted for C. difficile toxin EIA testing were cultured to isolate C. difficile. In-house PCR for tcdA, tcdB, cdtA, and cdtB genes were performed using C. difficile isolates. Stool specimens were tested with C. difficile toxins A and B using EIA kit (RIDASCREEN Clostridium difficile toxin A/B, R-Biopharm AG, Darmstadt, Germany). Characteristics and subsequent CDI episodes of toxin EIA-negative and -positive patients were compared. RESULTS: Among 190 C. difficile PCR-positive patients, 83 (43.7%) were toxin EIA-negative. Multivariate analysis revealed independent associations toxin EIA-negative results and shorter hospital stays (OR = 0.98, 95% CI 0.96-0.99, p = 0.013) and less high-risk antibiotic exposure in the preceding month (OR = 0.38, 95% CI 0.16-0.94, p = 0.035). Toxin EIA-negative patients displayed a significantly lower white blood cell count rate (11.0 vs. 35.4%, p < 0.001). Among the 54 patients who were toxin EIA-negative and did not receive CDI treatment, three (5.6%) were diagnosed with CDI after 7-21 days without complication. CONCLUSION: Our study demonstrates that toxin EIA-negative patients had milder laboratory findings and no complications, despite not receiving treatment. Prolonged hospitalisation and exposure to high-risk antibiotics could potentially serve as markers for the development of toxin EIA-positive CDI.


Asunto(s)
Proteínas Bacterianas , Toxinas Bacterianas , Clostridioides difficile , Infecciones por Clostridium , Heces , Humanos , Clostridioides difficile/genética , Heces/microbiología , Masculino , Femenino , Toxinas Bacterianas/análisis , Infecciones por Clostridium/diagnóstico , Infecciones por Clostridium/tratamiento farmacológico , Infecciones por Clostridium/microbiología , Anciano , Persona de Mediana Edad , Proteínas Bacterianas/genética , Proteínas Bacterianas/análisis , Enterotoxinas/análisis , Anciano de 80 o más Años , Antibacterianos/uso terapéutico , Técnicas para Inmunoenzimas , Adulto , Resultado del Tratamiento , Reacción en Cadena de la Polimerasa , Pronóstico
18.
J Thromb Haemost ; 22(7): 1936-1946, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38554935

RESUMEN

BACKGROUND: Laboratory diagnosis of immune-mediated thrombotic thrombocytopenic purpura (iTTP) remains challenging when ADAMTS-13 activity ranges between 10% and 20%. To prevent misdiagnosis, open ADAMTS-13 conformation gained clinical attention as a novel biomarker, especially to diagnose acute iTTP in patients with diagnostic undecisive ADAMTS-13 activity. Plasma ADAMTS-13 conformation analysis corrects for ADAMTS-13 antigen, with both parameters being characterized in enzyme-linked immunosorbent assay (ELISA)-based reference assays requiring expert technicians. OBJECTIVES: To design ADAMTS-13 antigen and conformation assays on automated, easy-to-use fiber optic surface plasmon resonance (FO-SPR) technology to promote assay accessibility and diagnose challenging iTTP patients. METHODS: ADAMTS-13 antigen and conformation assays were designed on FO-SPR technology. Plasma of 20 healthy donors and 20 acute iTTP patients were quantified, and data from FO-SPR and ELISA reference assays were compared. RESULTS: Following assay design, both antigen and conformation FO-SPR assays were optimized and characterized, presenting strong analytical sensitivity (detection limit of 0.001 µg/mL) and repeatability (interassay variation of 14.4%). Comparative analysis suggested positive correlation (Spearman r of 0.92) and good agreement between FO-SPR and ELISA assays. As expected, FO-SPR assays showed a closed or open ADAMTS-13 conformation in healthy donors and acute iTTP patients, respectively. CONCLUSION: Both ADAMTS-13 antigen and conformation assays were transferred onto automated, easy-to-use FO-SPR technology, displaying potent analytical sensitivity and reproducibility. ADAMTS-13 antigen and conformation were determined for healthy donors and acute iTTP patients showing strong correlation with ELISA reference. Introducing FO-SPR technology in clinical context could support routine diagnosis of acute iTTP patients, notably when ADAMTS-13 activity fluctuates between 10% and 20%.


Asunto(s)
Proteína ADAMTS13 , Ensayo de Inmunoadsorción Enzimática , Púrpura Trombocitopénica Trombótica , Resonancia por Plasmón de Superficie , Proteína ADAMTS13/sangre , Proteína ADAMTS13/inmunología , Humanos , Púrpura Trombocitopénica Trombótica/diagnóstico , Púrpura Trombocitopénica Trombótica/sangre , Púrpura Trombocitopénica Trombótica/inmunología , Ensayo de Inmunoadsorción Enzimática/métodos , Estudios de Casos y Controles , Biomarcadores/sangre , Reproducibilidad de los Resultados , Conformación Proteica , Valor Predictivo de las Pruebas , Inmunoensayo/métodos , Automatización de Laboratorios , Femenino , Masculino
19.
Hypertens Res ; 47(5): 1362-1371, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38454147

RESUMEN

The measurement evolution enabled more accurate evaluation of aldosterone production in hypertensive patients. However, the cut-off values for novel assays have been not sufficiently validated. The present study was undertaken to validate the novel chemiluminescent enzyme immunoassay for aldosterone in conjunction with other methods. Moreover, we also aimed to establish a new cut-off value for primary aldosteronism in the captopril challenge test using the novel assay. First, we collected 390 plasma samples, in which aldosterone levels measured using liquid chromatography-mass spectrometry ranged between 0.18 and 1346 ng/dL. The novel chemiluminescent enzyme immunoassay showed identical correlation of plasma aldosterone with liquid chromatography-mass spectrometry, in contrast to conventional radioimmunoassay. Further, we enrolled 299 and 39 patients with primary aldosteronism and essential hypertension, respectively. Plasma aldosterone concentrations measured using the novel assay were lower than those measured by radioimmunoassay, which resulted in decreased aldosterone-to-renin ratios. Subsequently, positive results of the captopril challenge test based on radioimmunoassay turned into "negative" based on the novel assay in 45% patients with primary aldosteronism, using the conventional cut-off value (aldosterone-to-renin activity ratio > 20 ng/dL per ng/mL/h). Receiver operating characteristic curve analysis demonstrated that aldosterone-to-renin activity ratios > 8.2 ng/dL per ng/mL/h in the novel assay was compatible with the conventional diagnosis (sensitivity, 0.874; specificity, 0.980). Our study indicates the great measurement accuracy of the novel chemiluminescent enzyme immunoassay for aldosterone, and the importance of measurement-adjusted cut-offs in the diagnosis of primary aldosteronism.


Asunto(s)
Aldosterona , Captopril , Hiperaldosteronismo , Mediciones Luminiscentes , Humanos , Hiperaldosteronismo/diagnóstico , Hiperaldosteronismo/sangre , Masculino , Femenino , Persona de Mediana Edad , Aldosterona/sangre , Estudios Retrospectivos , Adulto , Anciano , Mediciones Luminiscentes/métodos , Técnicas para Inmunoenzimas/métodos , Hipertensión/sangre , Hipertensión/diagnóstico , Renina/sangre , Estudios de Cohortes , Radioinmunoensayo
20.
J Hazard Mater ; 466: 133670, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38309155

RESUMEN

Capsaicinoids (CPCs) is a special ingredient with pungent smell in condiments, which can also be used as an exogenetic marker for kitchen waste oil. Development of immunoassay for CPCs remains a challenging due to relatively difficult preparation of the broad-spectrum antibody (Ab). In this work, a broad-spectrum polyclonal antibody (pAb) which can simultaneously recognize capsaicin (CPC), dihydrocapsaicin (DCPC), nordihydrocapsaicin (NDCPC), and N-vanillylnonanamide (N-V) is produced, and a non-enzyme immunoassay (NISA) based on this Ab, dendritic mesoporous silica nanomaterials (DMSNs), polydopamine (PDA), and high catalytic efficiency of Pt nanoparticles to prepare signal probe (DMSNs@PDA@Pt) is established. Here, the limit of detection (LOD) of NISA for CPC is as low as 0.04 µg L-1. It is worth mentioning that the LOD of the proposed NISA is at least 23 times lower than that of traditional enzyme-linked immunosorbent assay (ELISA) based on horseradish peroxidase (HRP). Moreover, the proposed NISA is applied to detect CPCs in edible oil samples, the result has good consistency with that of ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The proposed NISA based on DMSN@PDA@Pt and broad-spectrum Ab is an ideal tool for highly effective screening CPCs for kitchen waste oil abuse surveillance.


Asunto(s)
Indoles , Nanopartículas , Polímeros , Dióxido de Silicio , Cromatografía Liquida , Espectrometría de Masas en Tándem/métodos , Anticuerpos , Inmunoensayo/métodos , Límite de Detección
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA