Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 229
Filtrar
1.
Cutan Ocul Toxicol ; : 1-6, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39250681

RESUMEN

PURPOSE: To evaluate the effect of the intracameral adrenaline and trypan blue used during cataract surgery on corneal endothelial parameters in pseudoexfoliation syndrome (PEX) patients. METHODS: The patients were divided into four groups according to intraoperative use of agents during cataract surgery: intracameral adrenaline (1/10,000, 0.1 ml) (group 1), trypan blue (0.6 mg/ml, 0.1 ml) (group 2), combination of adrenaline and trypan blue (group 3) and none (group 4). RESULTS: Preoperative ECD, CV, HEX and CCT parameters were similar between the groups. A mean loss of 12.7% in ECD was observed at the postoperative third months compared to the preoperative. In group 3, ECD was found to be lower in the postoperative third months compared to the preoperative (p = 0.014). In the other groups, no statistically significant difference was found in preoperative and postoperative comparisons. CONCLUSION: In conclusion, the utilization of intracameral adrenaline or trypan blue did not cause a significant difference in corneal endothelium in PEX patients. However, their combined use may have a negative effect on endothelial cell density. In a cataract surgery performed in the presence of PEX, the increased likelihood of endothelial damage should be taken into consideration, and appropriate precautions should be taken preoperatively and intraoperatively.

2.
BMC Ophthalmol ; 24(1): 344, 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39143510

RESUMEN

BACKGROUND: To investigate the safety and effectiveness of non-viscoelastic agent technique for EVO-ICL implantation. METHODS: A total of 181 myopia eyes that underwent non-toric ICL without viscoelastic agent through single incision from Beijing Tongren Hosipital were included. An analysis was conducted on the quantity of haptics that were initially implanted intraoperatively into the posterior chamber. Intraocular pressure (IOP) was evaluated at before and 2 h,24 h,1week,6month after surgery. Anterior chamber volume(ACV), anterior chamber depth(ACD), anterior chamber angle(ACA), pupil diameter(PD) and corneal densitometry density (ECD) were evaluated at before and 24 h postoperatively. Refractive outcomes were investigated at before, 24 h ,7 days and 6months. Vault was evaluated at 24 h ,7 days and 6months. RESULTS: The efficacy and safety indices were 1.30 ± 0.32 and 1.31 ± 0.32, respectively. Of 181 eyes, 99 eyes received 4 haptics on the first attempt without any adjustment, and 72 eyes received lens alignment without an viscoelastic agent. The success rate of the viscoelastic agent free procedure was 94.5%. Two hours postoperatively, IOP was 17.41 ± 3.77 mmHg, which was significantly higher than baseline value (t = 8.930, P < 0.000), however there was no significant difference between preoperative IOP and IOP at 1 day ,1 week and 6 months postoperatively. The ECD changed from 2895.52 ± 253.73 cells/mm2 preoperatively to 2873.66 ± 244.17 cells/mm2 at 1 day and 2882.63 ± 239.97 postoperatively, and the difference was not statistically significant (t = 1.811, P = 0.072). The ACA was narrowed by 42% on the first day. CONCLUSION: The pure viscoelastic agent free technique is an efficient and safe way for ICL implantation. It can be a safer method of ICL implantation because of it reduces the risk of complications associated with ocular hypertension at the early postoperative stages. TRIAL REGISTRATION: Chinese Clinical Trial Registry (ChiCTR2000036335) at August 20, 2020.


Asunto(s)
Presión Intraocular , Implantación de Lentes Intraoculares , Miopía , Agudeza Visual , Humanos , Femenino , Masculino , Adulto , Implantación de Lentes Intraoculares/métodos , Presión Intraocular/fisiología , Adulto Joven , Miopía/cirugía , Miopía/fisiopatología , Refracción Ocular/fisiología , Persona de Mediana Edad , Sustancias Viscoelásticas/administración & dosificación , Adolescente , Lentes Intraoculares , Estudios Prospectivos , Estudios de Seguimiento , Resultado del Tratamiento
3.
BMC Ophthalmol ; 24(1): 375, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39187792

RESUMEN

BACKGROUND: Posterior chamber intraocular lens (IOL) dislocation is a common complication of cataract surgery. Dislocated IOLs often require surgical intervention due to the potentially severe risks of leaving this condition untreated. If a patient with extremely low corneal endothelial cell density (ECD) presents with IOL dislocation, the surgeon faces a crucial dilemma of choosing the most optimal surgical treatment option. We sought to investigate the efficacy and safety of retropupillary iris claw intraocular lens (R-IOL) implantation in patients with IOL dislocation and extremely low (< 1000 cells/mm2) ECD. METHODS: We retrospectively reviewed the medical records of nine patients (all men) whose pre-operative ECD was < 1000 cells/mm2 and who underwent R-IOL implantation due to intraocular subluxation or total dislocation into the vitreous cavity between 2014 and 2020. We evaluated corneal endothelial function and visual outcomes after surgery. RESULTS: Nine patients were included in this study. The mean age at diagnosis was 64.89 ± 7.15 years (range 57-76 years), and the follow-up duration was 37.93 ± 23.72 months (range 18.07-89.07 months). No patients developed bullous keratopathy during follow-up. Compared to the initial ECD, corneal thickness (CT), coefficient variation of cell area (CV) and percentage of hexagonal cells (HEX), there was no statistically significant decrease in the ECD, CV, and HEX at last follow-up (P = 0.944, 0.778, 0.445, 0.443). There was significant improvement in the mean uncorrected distance visual acuity (UDVA) at the last follow-up (average 0.13 logMAR, 20/27 Snellen) compared to the pre-operative mean UDVA (average 1.09 logMAR, 20/250 Snellen) (P < 0.01). CONCLUSIONS: R-IOL implantation did not result in a statistically significant decline in corneal endothelial function in patients with preoperatively low ECD, and it significantly improved the mean UDVA postoperatively. R-IOL implantation appears to be a safe and effective treatment modality for intraocular lens dislocation in patients with low ECD (< 1000 cells/mm²); however, long-term follow-up studies are warranted to corroborate these findings.


Asunto(s)
Endotelio Corneal , Implantación de Lentes Intraoculares , Lentes Intraoculares , Agudeza Visual , Humanos , Masculino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Endotelio Corneal/patología , Agudeza Visual/fisiología , Recuento de Células , Implantación de Lentes Intraoculares/métodos , Iris/cirugía , Pérdida de Celulas Endoteliales de la Córnea/diagnóstico , Migracion de Implante de Lente Artificial/cirugía , Migracion de Implante de Lente Artificial/fisiopatología , Estudios de Seguimiento , Femenino , Resultado del Tratamiento
4.
BMC Ophthalmol ; 24(1): 318, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39080583

RESUMEN

PURPOSE: Measurement of corneal endothelial cells is critical for postoperative evaluation of phakic intraocular lens (pIOL) surgery. However, inter-instrument differences in corneal endothelial cell density (ECD) after pIOL implantation have not yet been reported. This study aimed to compare automated corneal endothelial cell analysis between CellChek-20 (Konan Medical, Hyogo, Japan) and EM-4000 (Tomey, Nagoya, Japan) in healthy and postoperative eyes with pIOL. METHODS: We retrospectively analyzed 154 healthy and 236 postoperative eyes after pIOL surgery. Endothelial cell measurements were performed using CellChek-20 and EM-4000 with autofocusing and automated image analysis. ECD, percentage of hexagonal cells (HEX), coefficient of variation in cell size (CoV), and central corneal thickness (CCT) were compared between the two devices. RESULTS: The ECDs of the two devices were highly correlated in both healthy (Spearman's correlation coefficient [r] = 0.805; p < 0.001) and postoperative (r = 0.901; p < 0.001) groups. ECD from CellChek-20 was higher than EM-4000 in both healthy (mean difference = 228.9 cells/mm2; p < 0.001) and postoperative (mean difference = 115.6 cells/mm2; p < 0.001) groups. The CCT values also showed a strong correlation in healthy eyes (r = 0.974; p < 0.001) and in postoperative eyes (r = 0.936; p < 0.001); however, significant inter-instrument differences were observed. HEX and CV showed significant differences and relatively weak correlations (r < 0.7) between the two devices in both healthy and postoperative groups. CONCLUSION: The ECD values between the two instruments were correlated, but that of the CellChek-20 was significantly higher than that of the EM-4000 in both healthy and postoperative eyes after pIOL surgery. Most previous studies have also shown that the Konan software overestimated the ECD compared to other products in automatic measurement mode. The possibility of measurement bias should be considered when replacing equipment used for corneal endothelial cell measurements.


Asunto(s)
Endotelio Corneal , Lentes Intraoculares Fáquicas , Humanos , Endotelio Corneal/patología , Femenino , Recuento de Células , Masculino , Adulto , Estudios Retrospectivos , Estudios Transversales , Periodo Posoperatorio , Adulto Joven , Implantación de Lentes Intraoculares , Persona de Mediana Edad , Miopía/cirugía
5.
Vet Ophthalmol ; 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39011639

RESUMEN

PURPOSE: To evaluate the use of vital dyes and light microscopy for assessing canine corneal endothelial morphology ex vivo. METHODS: The corneas of 40 canine eyes (n = 20 dogs) enucleated <24 h following euthanasia or death were isolated and flat-mounted on a slide. Corneal endothelium was stained via 0.25% trypan blue followed by 0.5% alizarin red (pH 4.2), photographed, then the following morphological features were calculated using ImageJ: mean cell density (MCD), mean cell area (MCA), polymegathism (coefficient of variation of cell area), and pleomorphism (% hexagonality). RESULTS: Mean ± standard deviation (range) outcomes were: MCD, 2544 ± 541 cells/mm2 (1750-3922 cells/mm2); MCA, 431 ± 97 µm2 (251-626 µm2); polymegathism, 17 ± 2% (14%-22%); pleomorphism, 84 ± 3% (80%-90%). No significant differences (p ≥ .122) were noted for any outcome between male versus female or brachycephalic versus non-brachycephalic dogs. Young dogs (<10 years) had lower MCA (p = .044), lower pleomorphism (p = .003), and higher MCD (p = .035) when compared to older dogs (≥10 years). Age was significantly (p ≤ .049) correlated with MCA (r = 0.467), MCD (r = -0.476), polymegathism (r = 0.444), and pleomorphism (r = 0.609). CONCLUSIONS: The combination of vital dyes and light microscopy allowed for clear visualization and evaluation of the corneal endothelium in canine eyes ex vivo. Our findings can be used in future studies to deepen our understanding of the corneal endothelium in health and disease.

6.
Clin Ophthalmol ; 18: 1841-1849, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38952721

RESUMEN

Purpose: This study reports clinical outcomes up to 6 years after Descemet's membrane endothelial keratoplasty (DMEK) performed at the Department of Ophthalmology, Örebro University Hospital, Örebro, Sweden. Methods: The study has a cross-sectional and case series design. Inclusion criteria were all DMEK-operated eyes during 2013-2018 until repeat keratoplasty. Results: Altogether 162 eyes from 120 patients were enrolled. Among eyes without preoperative comorbidities, examined 1-6 years after DMEK, 85.8% achieved visual acuity of 0.1 logMAR or better. The median endothelial cell density (ECD) loss was 27% in a cohort of eyes examined 1-2 years post-DMEK, 31% at 2-3 years, 42% at 3-4 years, and > 60% at 4-6 years post-DMEK. ECD at the examination timepoint was correlated with donor ECD (as expected) and time since surgery. Conclusion: The results from DMEK surgeries in Örebro, Sweden, are promising. Further studies with even longer follow-up are needed to evaluate graft sustainability.

7.
BMC Ophthalmol ; 24(1): 269, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38918765

RESUMEN

BACKGROUND: To evaluate the optical performance and safety of a new multifocal lens with a novel optical design featuring two additional foci (or intensifiers) in patients with cataract and presbyopia. METHODS: In this single-center, non-randomized prospective observational study, 31 patients underwent implantation of the new multifocal IOL between March 2020 and November 2021 at a tertiary clinical center in Buenos Aires and Ramos Mejia, Argentina. Postoperative examinations with emphasis on uncorrected and corrected visual acuity at distance and near and at two different intermediate distances (80 cm and 60 cm) were performed during the 3 postoperative months. RESULTS: Of the 31 patients who underwent implantation of the new IOL, 30 underwent bilateral surgery (61 eyes in total). At 3 months, all 61 eyes had an uncorrected distance visual acuity (UCDVA) of at least 0.15 logMAR; 57 eyes (93%) had an uncorrected distance visual acuity (UCDVA) of 0.1 logMAR and 27 eyes (44%) had an UCDVA of 0.0 logMAR. At 80 cm, 60 eyes (98%) had an uncorrected intermediate visual acuity (UCIVA) of at least 0.1 log MAR and 48 eyes (79%) had an UCIVA of 0.0 logMAR. CONCLUSION: The new multifocal IOL with a novel optical concept (5 foci) showed a wide range of visual acuity especially at intermediate and near distances in patients undergoing cataract surgery. Uncorrected visual acuity was excellent at all tested distances, monocularly and binocularly, spectacle independence and patient satisfaction were high.


Asunto(s)
Lentes Intraoculares Multifocales , Presbiopía , Diseño de Prótesis , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Estudios Prospectivos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Presbiopía/fisiopatología , Presbiopía/cirugía , Refracción Ocular/fisiología , Implantación de Lentes Intraoculares , Seudofaquia/fisiopatología , Facoemulsificación , Catarata/complicaciones , Catarata/fisiopatología , Lentes Intraoculares , Anciano de 80 o más Años , Estudios de Seguimiento
8.
BMC Ophthalmol ; 24(1): 165, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38616259

RESUMEN

BACKGROUND: To assess the prevalence of low corneal endothelial cell density and correlates of corneal endothelial cell density among adults attending Mbarara University and Referral Hospital Eye Centre in Uganda. METHODS: In this hospital-based cross-sectional study, participants 18 years and older, were enrolled. We obtained informed consent, and basic demographic data. We also conducted visual acuity, a detailed slit lamp examination, intra-ocular pressure, corneal diameter, tear-film break-up time, keratometry, A-scan, and pachymetry on all participants. A confocal microscope Heidelberg HRT3 was used to examine the central cornea and to obtain the mean cell density (cells/mm2). To calculate the proportion of low endothelial cell density, descriptive statistics were used, whereas correlates of endothelial cell density were assessed, using linear regression analyses. RESULTS: We evaluated a total of 798 eyes of 404 participants aged between 18 and 90 years (males = 187, females = 217). The average endothelial cell density was 2763.6 cells/mm2, and there was a decrease in endothelial cell density with increasing age, irrespective of gender. There was no significant difference in endothelial cell density between males and females. Increasing age (adjusted coefficient - 10.1, p < 0.001), history of smoking (adjusted coefficient - 439.6, p = 0.004), history of ocular surgery (adjusted coefficient - 168.0, p = 0.023), having dry eye (adjusted coefficient - 136.0, p = 0.051), and having arcus senilis (adjusted coefficient - 132.0, p = 0.08), were correlated with lower endothelial cell density. However, increasing corneal diameter (adjusted coefficient 134.0, p = 0.006), increasing central corneal thickness (adjusted coefficient 1.2, p = 0.058), and increasing axial length (adjusted coefficient 65.8, p = 0.026), were correlated with higher endothelial cell density. We found five eyes (0.63%) from different participants with a low endothelial cell density (< 1000cells/mm2). CONCLUSION: Our study established baseline normal ranges of ECD in a predominantly black African population, and found that low ECD is rare in our population. The elderly, smokers, and those with past ocular surgery are the most vulnerable. The low prevalence could be due to a lack of reference values for the black African population.


Asunto(s)
Córnea , Hospitales , Adulto , Anciano , Femenino , Masculino , Humanos , Adolescente , Adulto Joven , Persona de Mediana Edad , Anciano de 80 o más Años , Uganda/epidemiología , Estudios Transversales , Células Endoteliales
9.
Ophthalmol Ther ; 13(6): 1773-1781, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38689101

RESUMEN

INTRODUCTION: Cataract surgery poses a risk to corneal endothelial cells. This study aimed to assess the protective effect of rho-associated kinase inhibitor eye drop (ripasudil) on corneal endothelial cells after cataract surgery over 12 months. METHODS: We conducted a prospective, non-randomized, non-blinded comparative study including 43 patients divided into two groups: the ripasudil group (22 patients, 23 eyes) and the control group (21 patients, 21 eyes). All patients had grade 3 nuclear cataract and underwent uneventful phacoemulsification with intraocular lens implantation. In the ripasudil group, one drop of ripasudil hydrochloride hydrate (Glanatec® ophthalmic solution 0.4%) was administered three times a day for 5 days. Outcome measures included central corneal thickness (CCT) and endothelial cell density (ECD), which were evaluated preoperatively and 12 months postoperatively. RESULTS: In the ripasudil group, the median ECD was 2398 (interquartile range [IQR] 410, 2201-2611) cells/mm2 at baseline and 2262 (IQR 298, 2195-2493) cells/mm2 at 12 months postoperatively. In the control group, the median ECD was 2503 (IQR 390, 2340-2730) cells/mm2 at baseline and 2170 (IQR 324, 2049-2373) cells/mm2 at 12 months postoperatively. Endothelial cell loss (ECL) was 12.8% in the control group, significantly reduced to 4.5% in the ripasudil group (p = 0.001*). CCT (p = 0.042), age (p = 0.383), sex (p = 0.944), and duration of surgery (p = 0.319) were not significant factors. No adverse effects were observed in either of the groups. CONCLUSIONS: Incorporating ripasudil into postoperative management could help maintain corneal endothelial cell integrity and reduce cell loss after cataract surgery, potentially decreasing the need for endothelial transplantation in patients who have undergone intraocular surgeries.

10.
Int Ophthalmol ; 44(1): 94, 2024 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-38368308

RESUMEN

PURPOSE: In the conventional technique, viscoelastic agents are typically rinsed away with balanced salt solution (BSS), but it may lead to a series of complications such as viscoelastic residue, anterior chamber instability and intraoperative TICL rotation. The utilization of irrigation and aspiration (I/A) has been shown to be effective in maintaining anterior chamber stability, reducing the incidence of postoperative high intraocular pressure, and minimizing postoperative fundus complications. However, there is a lack of previous studies investigating the impact of I/A on corneal endothelial cells during ICL implantation. The objective of this study was to examine the effect of I/A on corneal endothelial cells in patients undergoing myopia correction through implantation of Implantable Collamer Lens with a central hole (V4c ICL). METHODS: A retrospective selection was made of 344 eyes from 172 patients who underwent V4c ICL implantation and I/A to remove viscoelastic agent from the anterior chamber between 2021 and 2022. The intraocular pressure (IOP) was measured at 1 h, 2 h and 3 h after surgery. Corneal endothelial cell density (ECD), coefficient of variation in cell size (CV), standard deviation of cell area (SD), and percentage of hexagonal cells (HEX) were evaluated at 1 week postoperatively to assess corneal endothelial cells. The first two represent polymegethism or morphological variation, while the third parameter represents the degree of polymorphism of the corneal endothelial cells. Electronic medical records were utilized for data collection purpose. RESULTS: All surgeries proceeded without complications. The IOP was 16.50 ± 3.42 mmHg (range: 11.5-22.3 mmHg) prior to surgery and increased to 21.25 ± 5.61 mmHg (range: 9.5-34.8 mmHg), 19.85 ± 5.18 mmHg (range: 11.4-36.2 mmHg) and finally settled at an average of 18.81 ± 4.57 mmHg (range: 10.1-38.8 mmHg) at the respective time points of 1 h, 2 h and 3 h after surgery. The preoperative ECD was recorded as being approximately 3004 ± 295 cell/mm2, which exhibited a marginal decreased of 1.17% postoperatively, resulting in an average ECD value of 2969 ± 303 cell/mm2 one week after surgery (P = 0.12). Similarly, the preoperative CV was determined as 31.10 ± 3.78%, and it experienced a slight reduction with an average CV value of 30.74 ± 3.77% at week after surgery (P = 0.21). And, the preoperative SD was reported as 104.76 ± 17.26, and it remained virtually unchanged with an average SD value of 104.85 ± 18.75 at one week after surgery (P = 0.95). The preoperative HEX was calculated as 55.38 ± 8.94%, and it remained its stability with an average HEX value of 55.45 ± 8.73% one week after surgery (P = 0.92). CONCLUSION: The utilization of I/A led to a slight decrease in postoperative ECD when compared to conventional surgical techniques. Nevertheless, the reduction in ECD remained within acceptable limits, taking into accout the avervantaged it offered, such as stabilization of the anterior chamber and decreased occurrence of viscoelastic residue after surgery. It is challenging to anticipate the long-term safety of corneal endothelial cells based on current short-term studies. However, this study provides a valuable reference indicating that neither anterior chamber irrigation nor I/A aspiration have an adverse impact on the safety of corneal endothelial cells in the short term. Further research is imperative to enhance our understanding of their effects over an extended period.


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Refracción Ocular , Agudeza Visual , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Células Endoteliales , Miopía/cirugía
11.
Int Ophthalmol ; 44(1): 45, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38336985

RESUMEN

PURPOSE: To describe the in toto explantation of the CyPass® Micro-Stent and its conceivable complications. METHODS: This is a case series of eighteen eyes from fourteen patients who underwent CyPass® Micro-Stent implantation due to mild to moderate glaucoma and who subsequently suffered from loss of endothelial cell density. Consequently, the CyPass® Micro-Stent was in toto explanted. The surgical procedure and its complications are described and compared with trimming of the CyPass® Micro-Stent. RESULTS: A postoperative hyphema was developed in 8 of the 18 eyes. In four of them the hyphema was self-limiting, while in two patients an anterior chamber irrigation was necessary. One patient suffered from a severe intracameral bleeding and iridodialysis during explantation, so that the base of the iris had to be scleral fixated. The remaining explantations were without complications. CONCLUSION: Dealing with implanted CyPass® Micro-Stents poses a challenge for ophthalmic surgeons. An in toto removal can be traumatic, since the CyPass stent often is fibrotic encapsulated and fused with the surrounding tissue. Alternatively, trimming of the CyPass is also a viable option to avoid further endothelial damage. Reported complications of CyPass trimming are consistent with those that can occur after explantation. Further data on the development of the endothelial cells after trimming or explantation are not yet available. Therefore, it remains open whether trimming of the CyPass, in contrast to complete removal, carries the risk of further endothelial cell loss.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto , Compuestos de Quinolinio , Tiazoles , Humanos , Presión Intraocular , Células Endoteliales , Hipema , Glaucoma de Ángulo Abierto/cirugía , Implantes de Drenaje de Glaucoma/efectos adversos , Cámara Anterior , Stents/efectos adversos , Complicaciones Posoperatorias
12.
J Fr Ophtalmol ; 47(3): 104022, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37951743

RESUMEN

PURPOSE: To evaluate reproducibility of endothelial cell density (ECD) measurements using the Konan Cell Check D in donor corneas by two different ophthalmologists and to compare the two automated cell count methods (center and flex-center) available in the software of this specular microscope. METHODS: ECD values were quantified in 54 donor corneas by two independent investigators using the Cell Check D (Konan Medical USA Inc) with both automated cell count methods. In the center method, at least 30 contiguous cells are marked. For the flex-center method, an area is delineated and only the cells within the designated area are counted. RESULTS: The mean ECD was 2473.81±378.22 cells/mm2. Good ECD intergrader reproducibility for the center (ICC=0.821) and the flex-center method (ICC=0.784) were noted. Poor reliability was observed for coefficient of variation and hexagonality (ICC≤0.265). When both methods for ECD analysis were compared, a moderate correlation for the two independent graders using the two manual (center and flex-center) methods was detected (correlation coefficient of 0.678 and 0.745 for each of the investigators). Comparison between methods yielded significantly higher ECD with the flex-center method (P=0.013). When corneas were divided by ECD, those under 2200 cells/mm2 and those between 2200 and 2700 cells/mm2 also had significantly higher ECD with the flex-center method (P<0.022). CONCLUSIONS: ECD values are reproducible with both methods, although the flex-center method ECDs tend to be higher, particularly in cases of low ECD. Eye banks and surgeons should exercise caution in making decisions based only on small differences in ECD.


Asunto(s)
Endotelio Corneal , Bancos de Ojos , Humanos , Reproducibilidad de los Resultados , Córnea , Microscopía/métodos
13.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1022748

RESUMEN

Objective To observe the effects of repeated intravitreal injections of ranibizumab and aflibercept on cor-neal morphology of patients with neovascular age-related macular degeneration(nAMD),diabetic macular edema(DME)or retinal vein obstruction(RVO).Methods In this prospective study,64 patients(64 eyes)who underwent therapy in the injection center of the Ophthalmology Department of our hospital from June 2021 to June 2022 were enrolled,including 19 nAMD patients,20 DME patients and 25 RVO patients.Among these patients,29 were treated with aflibercept(40 g·L-1)and 35 were treated with ranibizumab(10 g·L-1).Monocular injections were adopted for all patients,and 3+pro re nata(PRN)therapy was used.Confocal microscope was used for corneal nerve examination,and corneal endo-thelial microscope was used to measure corneal thickness(CT)and corneal endothelial cells.The CT,corneal endothelial cell density(ECD),coefficient of variation(CV),average cell size(ACS),proportion of hexagonal cells(Hex%),cor-neal nerve fiber length(CNFL),corneal nerve fiber density(CNFD)of patients with nAMD,DME and RVO after repeated intravitreal injections of anti-vascular endothelial growth factor(VEGF)drugs were compared,and those parameters at 1 month after injection of different anti-VEGF drugs were compared with the baseline.Results Before injection,ECD in the DME group was lower than that in the nAMD and RVO groups,and the ACS in the DME group was higher than that in the nAMD and RVO groups(all P<0.05).There was no significant difference in the other indexes among the three groups(all P>0.05).After 3 injections of anti-VEGF drugs,the ECD in the DME group was lower than that in the nAMD and RVO groups,the ACS in the DME group was higher than that in the nAMD and RVO groups,and the CNFL in the DME group was lower than that in the nAMD and RVO groups(all P<0.05).The ECD decreased compared with that before injection from the 2nd injection of aflibercept in the nAMD group(all P<0.05).Hex%decreased significantly after each injection compared with the baseline(all P<0.05).Other indexes have no significant differences from the baseline(all P>0.05).In the RVO group,ECD decreased from the 2nd ranibizumab injection compared with the baseline(all P<0.05).Conclu-sion Repeated intravitreal injections of anti-VEGF drugs can reduce the Hex%and ECD to a certain extent.After injec-tions,CNFL in the DME group is significantly lower than that in the nAMD and RVO groups.

14.
Front Med (Lausanne) ; 10: 1294808, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38076276

RESUMEN

Background: During cataract phacoemulsification surgery, the Alcon Centurion with Active Sentry can achieve a more stable anterior chamber, which allows a lower intraocular pressure (IOP) setting than the gravity fluidics system. In this randomized controlled trial, we compared these two systems' damage to the cornea under different IOP settings. Methods: Seventy-eight eyes of 53 patients with corneal endothelial cell density (ECD) of 500∼1500/mm2 were enrolled and randomly divided into the active fluidics system (AFS) group using an Active Sentry handpiece with 30 mmHg IOP setting (40 eyes) and the gravity fluidics system (GFS) group using an Ozil handpiece with 80 cmH2O IOP setting (38 eyes). Intraoperative parameters, visual acuity, corneal edema ratio, central corneal thickness (CCT) changes as well as loss rate of ECD were analyzed. Results: We observed no significant differences in best corrected visual acuity (BCVA), cumulative dissipated energy (CDE), total case time, estimated fluidics usage (EFU) and ophthalmic viscoelastic devices (OVDs) usage between the two groups. The enrolled eyes were further divided into soft nucleus (27 eyes) and hard nucleus (51 eyes) subgroups. And we found less pain complaint during surgeries, lower corneal edema ratio at 1-day and 1-week visit, smaller CCT changes at 1-day visit and lower ECD loss rate at 1-month visit (p < 0.05) in both subgroups of the AFS group than in the GFS group, implying higher intraoperative comfort levels and less corneal damage of the AFS group with a low IOP setting. Conclusion: Owing to a lower IOP setting, Centurion® Vision System with Active Sentry handpiece causes less corneal damage and pain perception during phacoemulsification for patients with low pre-operative ECD. Clinical Trial Registration: https://www.chictr.org.cn, identifier ChiCTR2300077865.

15.
Medicina (Kaunas) ; 59(9)2023 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-37763779

RESUMEN

Background and Objectives: Hyperopia is a refractive error which affects cognitive and social development if uncorrected and raises the risk of primary angle-closure glaucoma (PACG). Materials and Methods: The study included only the right eye-40 hyperopic eyes in the study group (spherical equivalent (SE) under pharmacological cycloplegia over 0.50 D), 34 emmetropic eyes in the control group (SE between -0.50 D and +0.50 D). A complete ophthalmological evaluation was performed, including autorefractometry to measure SE, and additionally we performed Ocular Response Analyser: Corneal Hysteresis (CH), Corneal Resistance Factor (CRF); specular microscopy: Endothelial cell density (CD), Cell variability (CV), Hexagonality (Hex), Aladdin biometry: Anterior Chamber Depth (ACD), Axial Length (AL), Central Corneal Thickness (CCT). IBM SPSS 26 was used for statistical analysis. Results: The mean age of the entire cohort was 22.93 years (SD ± 12.069), 66.22% being female and 33.78% male. The hyperopic eyes had significantly lower AL, ACD, higher SE, CH, CRF. In the hyperopia group, there are significant, negative correlations between CH and AL (r -0.335), CRF and AL (r -0.334), SE-AL (r -0.593), ACD and CV (r -0.528), CV and CRF (r -0.438), CH (r -0.379), and positive correlations between CCT and CH (r 0.393) or CRF (r 0.435), CD and ACD (r 0.509) or CH (0.384). Age is significantly, negatively correlated with ACD (r -0.447), CH (r -0.544), CRF (r -0.539), CD (r -0.546) and positively with CV (r 0.470). Conclusions: Our study suggests a particular biomechanical behavior of the cornea in hyperopia, in relation with morphological and endothelial parameters. Moreover, the negative correlation between age and ACD suggests a shallower anterior chamber as patients age, increasing the risk for PACG.


Asunto(s)
Hiperopía , Errores de Refracción , Humanos , Femenino , Masculino , Adulto Joven , Adulto , Hiperopía/complicaciones , Cara , Córnea , Biometría
16.
Front Med (Lausanne) ; 10: 1190485, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37547606

RESUMEN

Purpose: To compare the surgical outcomes of combined penetrating keratoplasty (PK) and cataract surgery with those of sequential surgery (cataract surgery after PK) for herpes simplex keratitis (HSK). Methods: The medical records of consecutive patients diagnosed with HSK who underwent combined or sequential PK and cataract surgery in active and stable stages between June 2015 and June 2022 were reviewed retrospectively. Complications, graft survival, endothelial cell density (ECD), and final BCVA were compared and analyzed between both surgical methods in each stage. Results: A total of 171 eyes of 171 patients were enrolled, including active stage (69 combined, 46 sequential) and stable stage (34 combined, 22 sequential). The average follow up was 24.2 ± 15.8 months (range, 3 months - 48 months). The final BCVA had obvious improvement and the postoperative ECD was not different in combined and sequential groups of each stage. In sequential group of active stage, 66.7% of persistent epithelial defects and 50% of HSK recurrence occurred within 3 months after cataract surgery; nevertheless, compared to that in sequential group, capsular rupture (p = 0.021), persistent epithelial defects (p = 0.027), and HSK recurrence (p = 0.035) occurred more frequently in combined group, leading to a lower graft survival rate (p = 0.045); at the last visit, 46.4 and 67.4% of grafts remained clear in combined and sequential groups, respectively. By contrary, 82.4 and 50.0% of grafts remained clear in stable stages of combined and sequential groups at the last visit, respectively, and a higher graft survival rate was observed in combined group (p = 0.030). Conclusion: Although the postoperative ECD is not different between two surgical groups in each stage, sequential surgery in active stage of HSK seems to have advantages in less complications and higher graft survival rate, whereas combined surgery in stable stage has a better outcome than that in sequential surgery.

17.
Diagnostics (Basel) ; 13(15)2023 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-37568866

RESUMEN

Preoperative and postoperative diagnostics play an important role in ensuring the safety of patients with phakic intraocular lenses (pIOLs). The risk of endothelial cell loss can be addressed by regularly measuring the endothelial cell density using specular microscopy and considering the endothelial cell loss rate and the endothelial reserve in accordance with the patient's age when deciding whether to explant a pIOL. The anterior chamber morphometrics, including the anterior chamber depth and the distance between the pIOL and the endothelium, measured using Scheimpflug tomography and anterior segment optical coherence tomography (AS-OCT), can help to assess the risk of the endothelial cell loss. In patients undergoing posterior chamber pIOL implantation, accurate prediction of the vault and its postoperative measurements using AS-OCT or Scheimpflug tomography are important when assessing the risk of anterior subcapsular cataract and secondary glaucoma. Novel approaches based on ultrasound biomicroscopy and AS-OCT have been proposed to increase the vault prediction accuracy and to identify eyes in which prediction errors are more likely. Careful patient selection and regular postoperative follow-up visits can reduce the complication risk and enable early intervention if a complication occurs.

18.
Int Ophthalmol ; 43(12): 4491-4502, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37589863

RESUMEN

PURPOSE: To analyze and report the long-term outcomes in terms of efficacy and safety of eyes implanted with the spherical version of a foldable iris-fixated phakic intraocular lens (pIOL) for the correction of myopia. METHODS: Retrospective analysis of the results of 56 eyes of 32 patients (age, 19-45 years) who underwent implantation of the spherical model of the Artiflex pIOL (Ophtec B.V., Groningen, The Netherlands) for the correction of myopia. Visual, refractive, biometric, intraocular pressure (IOP) and corneal endothelial changes were evaluated during a long-term follow-up: 2, 7, 10 and 12 years for more than 50, 30, 20 and 10 eyes, respectively. RESULTS: At 4 weeks postoperatively, a significant reduction of manifest sphere and spherical equivalent (SE), with a significant improvement of uncorrected distance visual acuity were found (all p < 0.001). No significant changes were found during the rest of follow-up in sphere (p ≥ 0.072). The percentage of eyes with SE within ± 1.00 D was over 83% during the whole follow-up. A non-significant trend to IOP increase was observed at 4 weeks postoperatively (p = 0.530), with a significant reduction at 1 year after (p = 0.039) and no significant changes during the rest of follow-up (p = 0.180). There was a significant reduction of anterior chamber depth at 4 weeks after surgery (p < 0.001), with no significant changes during the following 9 years of follow-up (p = 0.118). However, an additional significant decrease of this parameter was observed between 10 and 13 years after surgery (p = 0.027). Mean endothelial cell loss changed from 2.01 ± 4.49% at 4 weeks after surgery to 9.11 ± 2.24% at the end of the follow-up. No complications were reported during the follow-up. CONCLUSIONS: Myopia correction with the Artiflex pIOL is an effective and safe procedure in the long term.


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Estudios de Seguimiento , Estudios Prospectivos , Miopía/cirugía , Refracción Ocular , Iris/cirugía
19.
Cutan Ocul Toxicol ; 42(4): 243-247, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37531136

RESUMEN

PURPOSE: To assess the effect of hyperbaric oxygen therapy (HBOT) on corneal endothelial structure and anterior segment parameters in healthy eyes. METHODS: 17 eyes of 17 patients who were scheduled to receive HBOT for other than ophthalmologic indications were investigated in this prospective study. Central corneal thickness (CCT) and corneal endothelial properties were evaluated using a specular microscope. Endothelial cell density (ECD), average cell area (AVG), coefficient of variation in cell size (CV), percentage of hexagonal cells (HEX), CCT, intraocular pressure (IOP), spherical equivalent (SE), axial length (AL) and anterior chamber depth (ACD) values were measured before the HBOT, after the 1st session, and after the 20th session of therapy. RESULTS: 47% of the patients (n = 8) received HBOT because of avascular necrosis, 35% (n = 6) due to sudden hearing loss, 12% (n = 2) for diabetic foot, and 6% (n = 1) for wound infection. The mean IOP was 14,80 mmHg before HBOT, 14,20 mmHg after the 1st session, and 13,73 mmHg after the 20th session. The mean ACD was 3,38 mm before HBOT, 3,34 mm after the 1st session, and 3,16 mm after the 20th session. Although the mean IOP and ACD decreased after HBOT sessions, it was not statistically significant (p > 0.05). A significant reduction was observed in SE values after 20 sessions of HBOT compared to the values measured before HBOT (p = 0,009). The mean ECD was 2572,53 ± 261,51 cells/mm2 before HBOT, 2554,47 ± 236,13 after the 1st session, and 2563,13 ± 226,92 after the 20th session. When the corneal properties measured before and after HBOT sessions were compared, no significant difference was found in terms of CCT, ECD, AVG, CV, and HEX (p > 0.05). CONCLUSION: We observed no significant change in CCT, corneal endothelial layer properties, and anterior segment morphology after the 1st session, and after the 20th session of HBOT. Although HBOT reduced IOP and ACD, it was not statistically significant. HBOT may lead to a significant decrease in SE values after the 20th session.


Asunto(s)
Oxigenoterapia Hiperbárica , Humanos , Estudios Prospectivos , Córnea , Endotelio Corneal , Presión Intraocular
20.
Am J Ophthalmol Case Rep ; 32: 101883, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37484136

RESUMEN

Purpose: To report late central graft detachment after repeat Descemet membrane endothelial keratoplasty (DMEK) without visual reduction. Observations: A 71-year-old patient with Fuchs' endothelial corneal dystrophy received a DMEK in his left eye. At 11 month post-operatively, a subtotal graft detachment was noted. Due to increasing corneal edema with vision loss, the first DMEK was removed and a repeat-DMEK was performed. At four months post repeat-DMEK, the graft was fully adherent to the posterior stroma. There was no significant corneal edema, and the best corrected visual acuity was 20/25. At 16-months after repeat-DMEK, a central graft detachment was noted, but there was no concurrent corneal edema or any loss of visual acuity. The mean density of the central endothelial cells was measured at 842 cells/mm2. Given the lack of corneal edema, visual reduction or subjective visual complaint, the graft detachment was followed-up for up to 20-months post repeat-DMEK with no further intervention, where the central cornea remained clear. Conclusions and Importance: To our knowledge, this is the first report of a central repeat-DMEK graft detachment that occurred 16 months after surgery despite initial attachment. Interestingly, there was no concurrent corneal edema or vision reduction. We describe a potential mechanism for clear central cornea in the presence of a central graft detachment after repeat-DMEK.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA