1.
Cancer Radiother ; 17(4): 288-96, 2013.
Artículo en Francés | MEDLINE | ID: mdl-23871458

RESUMEN

PURPOSE: To develop an external quality control procedure for CyberKnife(®) beams. This work conducted in Nancy, has included a test protocol initially drawn by the medical physicist of Nancy and Lille in collaboration with Equal-Estro Laboratory. MATERIALS AND METHODS: A head and neck anthropomorphic phantom and a water-equivalent homogeneous cubic plastic test-object, so-called "MiniCube", have been used. Powder and solid thermoluminescent dosimeters as well as radiochromic films have been used to perform absolute and relative dose studies, respectively. The comparison between doses calculated by Multiplan treatment planning system and measured doses have been studied in absolute dose. The dose distributions measured with films and treatment planning system calculations have been compared via the gamma function, configured with different tolerance criteria. RESULTS: This work allowed, via solid thermoluminescent dosimeter measurements, verifying the beam reliability with a reproducibility of 1.7 %. The absolute dose measured in the phantom irradiated by the seven participating centres has shown an error inferior to the standard tolerance limits (± 5 %), for most of participating centres. The relative dose measurements performed at Nancy and by the Equal-Estro laboratory allowed defining the most adequate parameters for gamma index (5 %/2mm--with at least 95 % of pixels satisfying acceptability criteria: γ<1). These parameters should be independent of the film analysis software. CONCLUSION: This work allowed defining a dosimetric external quality control for CyberKnife(®) systems, based on a reproducible irradiation plan through measurements performed with thermoluminescent dosimeters and radiochromic films. This protocol should be validated by a new series of measurement and taking into account the lessons of this work.


Asunto(s)
Garantía de la Calidad de Atención de Salud/organización & administración , Radiometría/normas , Radiocirugia/normas , Calibración , Colorimetría/métodos , Conducta Cooperativa , Fluoruros/efectos de la radiación , Humanos , Compuestos de Litio/efectos de la radiación , Aceleradores de Partículas , Fantasmas de Imagen , Proyectos Piloto , Polvos , Control de Calidad , Radiometría/métodos , Radiocirugia/instrumentación , Planificación de la Radioterapia Asistida por Computador , Reproducibilidad de los Resultados , Robótica/instrumentación , Colorantes de Rosanilina/efectos de la radiación , Dosimetría Termoluminiscente/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA