RESUMEN
The objective was to evaluate the effect of the incorporation of calcium hydroxyapatite particles (HAp) in the diametral tensile strength of a conventional type II glass ionomer (GC Gold Label 2) and a resin-modified glass ionomer cement (GC Gold Label 2 LC R). Two experimental HAp (E1HAp or E2HAp) were synthesized and characterized using X-ray diffraction and Confocal Raman spectroscopy. Both HAp were added into the powder of a conventional or resin-modified glass ionomer cement at 5 or 10 wt.%. A commercial HAp (CHAp) was used as reference material. For each glass ionomer cement, a group without the incorporation of HAp was used as a control. A universal testing machine was used for the mechanical test. The results were analyzed through a two-way ANOVA test followed by a complementary Tukey test. For all analyzes, the level of significance was set at α = 0.05. The average particle size for E1Hap was 15 µm, E2HAp was 35 µm and for CHAp was 1 µm. For conventional GIC, the addition of 10% E1HAp and 5% CHAp significantly increased the diametral tensile strength values (p ≤ 0.005). On the other hand, for the resin-modified GIC, except for the 5% E2HAp group, all experimental groups significantly reduced the values of diametral tensile strength (p ≤ 0.007). The addition of HAp improved the mechanical properties only for the conventional glass ionomer cement.
Asunto(s)
Durapatita , Cementos de Ionómero Vítreo , Ensayo de Materiales , Resistencia a la TracciónRESUMEN
A resistência à tração diametral (TD) é um requisito essencial para o sucesso clínico das restaurações. Dessa forma, este estudo objetivou avaliar a resistência à TD de três tipos cimentos ionômero de vidro (CIV) em comparação com uma resina composta, todos utilizados em seis postos de saúde pública do município de Duque de Caxias/RJ. O TD foi realizado em uma máquina universal com uma célula de carga de 200 Kgf. Os valores médios de resistência à TD, em MPa, foram: 11,46 (CIV A), 10 (CIV B), 31 (CIV C) e 38,13 (Resina). Os resultados foram analisados pelos testes Anova e Turkey (p < 0,05). Concluiu-se que os CIVs apresentaram resistência à TD semelhante entre eles, porém inferior à resina, mas ainda sendo uma ótima opção para restauração preconizada pelo Serviço Público de Saúde (SUS).
The diametric tensile strength (DT) is a prerequisite for clinical success of restoration. Thus, this study aimed to evaluate the resistance of DT of three types of glass ionomer cements (IO) for restorative, and compare with a composite resin. Eight samples of each material were using by bipartite matrices. All of the materials were used according to manufacturers. The DT test was performed using a universal testing machine with a load of 200 kgf. The results were analyzed using Anova and Turkey (p <0.05). Mean values for resistance to DT in MPa were: 11.46 (IO A), 10 (IO B), 31 (IO C) and 38.13 (Resin composite). We concluded that IO showed similar DT among themselves.
Asunto(s)
Resistencia a la Tracción , Técnicas In Vitro , Resinas Compuestas , Materiales Dentales , Cementos de Ionómero VítreoRESUMEN
A resistência à tração diametral (TD) é um requisito essencial para o sucesso clínico das restaurações. Dessa forma, este estudo objetivou avaliar a resistência à TD de três tipos cimentos ionômero de vidro (CIV) em comparação com uma resina composta, todos utilizados em seis postos de saúde pública do município de Duque de Caxias/RJ. O TD foi realizado em uma máquina universal com uma célula de carga de 200 Kgf. Os valores médios de resistência à TD, em MPa, foram: 11,46 (CIV A), 10 (CIV B), 31 (CIV C) e 38,13 (Resina). Os resultados foram analisados pelos testes Anova e Turkey (p < 0,05). Concluiu-se que os CIVs apresentaram resistência à TD semelhante entre eles, porém inferior à resina, mas ainda sendo uma ótima opção para restauração preconizada pelo Serviço Público de Saúde (SUS).
The diametric tensile strength (DT) is a prerequisite for clinical success of restoration. Thus, this study aimed to evaluate the resistance of DT of three types of glass ionomer cements (IO) for restorative, and compare with a composite resin. Eight samples of each material were using by bipartite matrices. All of the materials were used according to manufacturers. The DT test was performed using a universal testing machine with a load of 200 kgf. The results were analyzed using Anova and Turkey (p <0.05). Mean values for resistance to DT in MPa were: 11.46 (IO A), 10 (IO B), 31 (IO C) and 38.13 (Resin composite). We concluded that IO showed similar DT among themselves.
Asunto(s)
Resistencia a la Tracción , Resinas Compuestas , Materiales Dentales , Cementos de Ionómero VítreoRESUMEN
Introdução: O cimento de ionômero de vidro é um material odontológico que apresenta limitações de uso devido às suas propriedades mecânicas, como baixa resistência ao desgaste, microdureza, compressão e tração diametral. Com base nisso, este estudo investigou o efeito da excitação ultrassônica sobre o CIV, em diferentes tempos de aplicação, por meio da resistência à tração diametral. Material e Método: Os materiais utilizados foram o Ketac Molar Easymix (KME) e o Ketac Cem Easymix (KCE). Foram confeccionados 10 corpos de prova para cada condição estudada: grupo controle, e os grupos que receberam aplicação de ultrassom por 15s, 30s e 45s, para ambos materiais. A excitação ultrassônica foi aplicada durante a reação de presa inicial do CIV, logo após sua inserção na matriz de silicone. Os valores de resistência à tração diametral foram analisados pelo teste Shapiro Wilk e Anova (α = 0.05). Resultado: A aplicação de excitação ultrassônica não apresentou efeito estatisticamente significante na resistência à tração diametral dos materiais testados, independente do tempo de aplicação (p > 0,05). O KME apresentou resistência estatisticamente maior que o KCE (p = 0,023). Conclusão: A utilização das ondas ultrassônicas não influenciou na resistência à tração diametral dos CIV testados independentemente do seu tempo de aplicação.
Introduction: The glass ionomer cement is a dental material that has limitations of use due to its mechanical properties, such as low wear resistance, hardness, tensile and compressive diametral. Based on this, this study investigated the effect of ultrasonic excitation on the GIC in different application times, through the diametral tensile strength. Material and Method: The materials used were Ketac Molar EasyMix (KME) and Ketac Cem EasyMix (KCE). Were made 10 specimens for each condition studied: control group, and the groups that received application of ultrasound for 15s, 30s and 45s, for both materials. The ultrasonic excitation was applied during the initial setting reaction of GIC, soon after its insertion into the silicone matrix. The values of the diametral tensile strength were analyzed by Shapiro Wilk test and ANOVA (α = 0.05). Result: The application of ultrasonic excitation showed no statistically significant effect on diametral tensile strength of the materials tested, regardless of the time of application (p > 0.05). The KME resistance showed statistically greater than the KCE (p = 0.023). Conclusion: The use of ultrasound waves did not influence the diametral tensile strength of CIV tested regardless of their time of application.
Asunto(s)
Resistencia a la Tracción , Ultrasonido , Análisis de Varianza , Cementos de Ionómero VítreoRESUMEN
The purpose of this study was to determine the influence of incrementally added uncured HEMA in experimental HEMA-added glass ionomer cement (HAGICs) on the mechanical and shear bond strength (SBS) of these materials. Increasing contents of uncured HEMA (10-50 wt. percent) were added to a commercial glass ionomer cement liquid (Fuji II, GC, Japan), and the compressive and diametral tensile strengths of the resulting HAGICs were measured. The SBS to non-precious alloy, precious alloy, enamel and dentin was also determined after these surfaces were subjected to either airborne-particle abrasion (Aa) or SiC abrasive paper grinding (Sp). Both strength properties of the HAGICs first increased and then decreased as the HEMA content increased, with a maximum value obtained when the HEMA content was 20 percent for the compressive strength and 40 percent for the tensile strength. The SBS was influenced by the HEMA content, the surface treatment, and the type of bonding surface (p<0.05). These results suggest that addition of an appropriate amount of HEMA to glass ionomer cement would increase diametral tensile strength as well as bond strength to alloys and teeth. These results also confirm that the optimal HEMA content ranged from 20 to 40 percent within the limitations of this experimental condition.
Asunto(s)
Anteojos , Metacrilatos/metabolismo , Fenómenos Biomecánicos , Microscopía de Fuerza Atómica , Microscopía Electrónica de Rastreo , Resistencia a la TracciónRESUMEN
Neste estudo avaliou-se o efeito de diferentes protetores de superfície na liberação de flúor (LF) e na resistência à tração diametral (TD) de dois cimentos de ionômero de vidro (CIV) convencionais restauradores, Chemfil e Chemflex (Dentsply). Manipulou-se os cimentos segundo as recomendações do fabricante, os espécimes confeccionados foram divididos em cinco grupos: grupo1 sem protetor (controle); grupo2 vaselina sólida; grupo3 verniz (Cavitine, S.S.White); grupo4 verniz fluoretado (Duraflur, Denstply); grupo5 adesivo (Magic Bond, Vigodent). Confeccionou-se para o teste de LF 40 espécimes para cada CIV, com dimensões de 4 mm de diâmetro por 6 mm de comprimento, divididos aleatoriamente entre os grupos e estocados individualmente em potes plásticos contendo 5 ml de água deionizada. Registrou-se o nível de fluoreto no período de 04 horas, 24 horas, 03 dias, 07 dias e 14 dias após a confecção, em um analisador Expandable Íon Analyser EA 960, sendo os resultados calculados em μgF/ cm2. Confeccionou-se para o ensaio de TD 120 espécimes para cada CIV, com dimensões de 4 mm de diâmetro por 6 mm de comprimento, divididos aleatoriamente entre os grupos. Realizou-se ensaios mecânicos, com 1 dia e 14 dias após a confecção e estocagem individual dos espécimes em potes plásticos contendo 5 ml de água deionizada, em uma máquina universal de ensaios EMIC DL 500 MF, realizou-se um terceiro teste após 14 dias de ciclos de des-remineralização. Tratou-se estatisticamente os dados obtidos por ANOVA e por Student Newman-Keuls (p<0,05). No teste de LF os resultados demonstraram que o Chemfil liberou uma quantidade significantemente maior de flúor do que o Chemflex. Durante o período do teste a vaselina e o verniz tiveram um comportamento semelhante, mostrando uma menor LF do que o grupo controle nas primeiras 4 horas, com uma maior liberação na análise seguinte (24 horas)...
This study evaluated the effect of different protective coatings on the fluoride release (FR) and on the diametral tensile strength (DTS) of two conventional restorative glass ionomer cements (GIC), Chemfil e Chemflex (Dentsply). The cements were manipulated according to the manufacturer's recommendation. The especimens were divided into five groups: group 1 uncoated (control group); group 2 petroleum jelly; group 3 dental varnish (Cavitine, S.S.White); group 4 - fluoride varnish (Duraflur, Denstply); group 5 dentin adhesive (Magic Bond, Vigodent). To the FR test were made 40 especimens to each CIV, with dimensions of 4mm in diameter by 6 mm in length divided randomly into the groups and kept individually in plastic containers with 5 mL of deionized water. The fluoride level was registered within 04 hours, 24 hours, 3 days, 7 days and 14 days after the confection in an Expandable Íon Analyser EA 960, and the results were calculated in μgF/ cm2. To the DTS test 120 especimens were made to each GIC, with dimensions of 4mm in diameter by 6mm in length divided randomly into the groups. Mechanical tests were made within 1 day and 14 days after the confection and saving of specimens individually in plastic containers with 5 mL of deionized water, in an universal tests machine EMIC DL 500 MF, and a third test was made after 14 days of des-remineralization cycles. The data was statistically treated by ANOVA and by Student Newman-Keuls (p<0,05). In the FR test the results showed that the Chemfil released a significant bigger amount of fluoride then the Chemflex. During the tests period, the petroleum jelly and the dental varnish had a similar behavior, presenting lower fluoride release then the control group in the first 4 hours, with a greater release in the second analysis (within 24 hours)...