Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 282
Filtrar
1.
J Oral Rehabil ; 51(11): 2354-2360, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39128892

RESUMEN

BACKGROUND: The literature is unclear about how the different attachment systems for overdentures impact the maximum bite force, the masticatory efficiency and how this impact in the oral health self-perception in patients. OBJECTIVE: To evaluate the effect of two attachment systems (O-ring and Locator) for mandibular overdenture using single implant on quality of life, maximum bite force (BF) and masticatory efficiency (ME). METHODS: Twenty-eight completely edentulous denture wearers with a mandibular symphysis implant were randomly selected and allocated into two groups in a crossover study, considering O-ring and Locator attachment types. The quality of life and self-perception of oral health were assessed using the Oral Health Impact Profile (OHIP-Edent) and Geriatric Index of Determination of Oral Health (GOHAI) questionnaires, respectively. BF was measured using a gnathodynamometer and ME by chewing silicone cubes and almonds in different numbers of cycles. RESULTS: There was no difference between the attachment systems about self-perceived oral health and impact on quality of life (p > .05). The O-ring-type system obtained a significantly higher BF than the locator-type system (p = .04). Regardless of the food chewed, no statistically significant difference was observed with the type of attachment (p > .05). The ME was directly proportional to the masticatory cycles only for almonds (p < .01). CONCLUSIONS: Locator and O-ring inserts had a similar impact on patients' quality of life, self-perception of oral health and ME. Additionally, the O-ring system exhibited superior properties in the BF.


Asunto(s)
Fuerza de la Mordida , Estudios Cruzados , Prótesis de Recubrimiento , Masticación , Salud Bucal , Calidad de Vida , Autoimagen , Humanos , Masculino , Masticación/fisiología , Femenino , Anciano , Retención de Dentadura , Persona de Mediana Edad , Prótesis Dental de Soporte Implantado , Diseño de Dentadura
2.
RGO (Porto Alegre) ; 72: e20240001, 2024. tab
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1550639

RESUMEN

ABSTRACT One of the most common dental procedures is tooth extraction; however, the bone defect resulting from the process is only partially restored, leading to considerable bone loss. To rehabilitate a fully or partially edentulous patient, we must handle these sites with delicate surgical procedures. There is a large literature presenting attempts to overcome the negative effects of a dental extraction, with the aim of reducing tissue volume loss or restoring the alveolar architecture. In this context, Partial Extraction Therapy (PET) represents a subgroup of interventions to prevent bone loss after extraction using the tooth itself to prevent alveolar bone loss. This literature review aims to make a survey of the published articles on PET, with an emphasis on socket shield technique, and to explain the other techniques such as root burial, pontic-shield and proximal socket-shield, their indications and counter indications in order to deepen the knowledge of these techniques. To identify the included or considered studies, we adopted a detailed search strategy for MEDLINE and Cochrane Library focused in the last 31 years, whose language was English, Spanish or Portuguese. This text presents an analysis of current data regarding the alternatives for alveolar preservation and the installation of immediate implants in these areas, presenting the possibility of a different surgical technique. However, due to the immaturity and lack of conclusive scientific evidence regarding the predictability of the procedures, it is considered that the use of the socket shield technique must be done in an extremely cautious way.


RESUMO Um dos procedimentos odontológicos mais comuns é a extração dentária, contudo, , o defeito ósseo decorrente do processo é apenas parcialmente restaurado, levando a uma perda ossea volumétrica consideravel. Para reabilitar um paciente totalmente ou parcialmente desdentado, devemos manusear estes sitios com intervenções cirúrgicas delicadas. Há uma vasta literatura apresentando tentativas de transpor os efeitos negativos de uma extração dentária, com o objetivo de diminuir a perda volumétrica tecidual ou restaurar a arquitetura alveolar. Neste contexto, a Terapia de Extração Parcial (TEP) representa um subgrupo de intervenções para prevenir a perda óssea após exodontia, usando o próprio dente para prevenir a perda óssea alveolar. Essa revisão de literatura tem por objetivo fazer um levantamento dos artigos publicados sobre as TEP, com ênfase na técnica de socket shield, e explanar a cerca das demais técnicas como sepultamento radicular, pontic-shield e proximal socket-shield, suas indicações e contra-indicações, a fim de aprofundar o conhecimento dessas técnicas. Para a identificação dos estudos inclui?dos ou considerados, adotamos a estrate?gia de busca detalhada para os bancos MEDLINE e Biblioteca Cochrane nos u?ltimos 31 anos, cujo idioma fosse o ingle?s, espanhol ou o portugue?s. Este texto, apresenta uma análise de dados atuais a respeito das alternativas para a preservação alveolar e instalação de implantes imediatos nestas áreas, apresentando a possibilidade de uma técnica cirúrgica diferenciada. No entanto, devido a imaturidade e falta de comprovação cientifica contundente a respeito da previsibilidade dos procedimentos, considera-se que o emprego da técnica de socket shield deve ser feito de forma cautelosa.

3.
J. appl. oral sci ; J. appl. oral sci;32: e20240018, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1558232

RESUMEN

Abstract Objective This study aimed to validate the integrated correlation between the buccal bone and gingival thickness of the anterior maxilla, and to gain insight into the reference plane selection when measuring these two tissues before treatment with implants. Methodology Cone beam computed tomography (CBCT) and model scans of 350 human subjects were registered in the coDiagnostiX software to obtain sagittal maxillary incisor sections. The buccal bone thickness was measured at the coronal (2, 4, and 6 mm apical to the cementoenamel junction [CEJ]) and apical (0, 2, and 4 mm coronal to the apex plane) regions. The buccal gingival thickness was measured at the supra-CEJ (0, 1mm coronal to the CEJ) and sub-CEJ regions (1, 2, 4, and 6 mm apical to the CEJ). Canonical correlation analysis was performed for intergroup correlation analysis and investigation of key parameters. Results The mean thicknesses of the buccal bone and gingiva at different levels were 0.64~1.88 mm and 0.66~1.37 mm, respectively. There was a strong intergroup canonical correlation between the thickness of the buccal bone and that of the gingiva (r=0.837). The thickness of the buccal bone and gingiva at 2 mm apical to the CEJ are the most important indices with the highest canonical correlation coefficient and loadings. The most and least prevalent subgroups were the thin bone and thick gingiva group (accounting for 47.6%) and the thick bone and thick gingiva group (accounting for 8.6%). Conclusion Within the limitations of this retrospective study, the thickness of the buccal bone is significantly correlated with that of the buccal gingiva, and the 2 mm region apical to the CEJ is a vital plane for quantifying the thickness of these two tissues

4.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1528853

RESUMEN

The purpose of this research was to compare the vital signs of ASA II patients undergoing dental implant surgery under intravenous anesthesia to those of ASA I patients. From a specialist course in Implant Dentistry, 41 medical records (22 ASA I and 19 ASA II patients) were analyzed. Age, gender, ASA classification, blood pressure, heart rate, and oxygen saturation were all measured. Pre-surgery, following the onset of local anesthetic, at the end of the initial implant insertion, and at the end of surgery were all used to collect vital signs. Student's t-test (p<0.05) was used to determine inter- and intra-group data associations. The crossing of operative moments pre-surgical and installation of the first implant in both systolic (p<=0.01) and diastolic (p<=0.03) pressure was statistically significant in ASA I patients. In contrast, there was only a statistical difference in the verification of peripheral oxygen saturation data at preoperative and local anesthesia times in ASA II patients (p<=0.04). When comparing the time of installation of the first implant (p<=0.03) and at the end of surgery (p<=0.02), with respect to systolic pressure, ASA II presented statistically higher, while variable oxygen saturation at the beginning of local anesthesia in ASA I was statistically higher (p<=0.04). It is proposed that intravenous sedation acts in a compensatory manner in patients with systemic disease, leading both groups' behavior to be similar.


El propósito de esta investigación fue comparar los signos vitales de pacientes ASA II sometidos a cirugía de implante dental bajo anestesia intravenosa con los de pacientes ASA I. Se analizaron 41 historias clínicas de un curso de especialista en Implantología (22 pacientes ASA I y 19 ASA II). Se midieron la edad, el sexo, la clasificación ASA, la presión arterial, la frecuencia cardíaca y la saturación de oxígeno. Se tomarn los signos vitales antes de la cirugía, después del inicio de la anestesia local, al final de la inserción inicial del implante y al final de la cirugía. Se utilizó la prueba t de Student (p<0,05) para determinar las asociaciones de datos entre e intragrupos. El cruce de los momentos operatorios prequirúrgicos y de instalación del primer implante tanto en la presión sistólica (p<=0,01) como en la diastólica (p<=0,03) fue estadísticamente significativo en los pacientes ASA I. En contraste, solo hubo diferencia estadística en la verificación de los datos de saturación periférica de oxígeno en el momento preoperatorio y de anes- tesia local en los pacientes ASA II (p<=0,04). Al comparar el tiempo de instalación del primer implante (p<=0,03) y al final de la cirugía (p<=0,02), con respecto a la presión sistólica, el ASA II se presentó estadísticamente mayor, mientras que la variable saturación de oxígeno al inicio de la anestesia local en El ASA I fue estadísticamente mayor (p<0,4). Se propone que la sedación intravenosa actúa de forma compensatoria en pacientes con enfermedad sistémica, lo que hace que el comportamiento de ambos grupos sea similar.

5.
J Oral Implantol ; 49(5): 537-543, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37776244

RESUMEN

Routine use of antibiotics for dental implant installation is widely applied in dental practice to prevent postoperative infection and implant loss. However, the effectiveness and necessity of such protocols have not been consensual in the literature. This study aimed to evaluate the effect of antibiotic prophylaxis on survival of dental implants placed in clinically healthy patients by unexperienced operators. A double-blind, randomized, placebo-controlled trial was conducted. Ninety patients who received between 2 and 4 dental implants by unexperienced operators were enrolled in this study. Patients were randomly allocated in 2 groups. For the antibiotic group (n = 47), patients received 1 g of preoperative amoxicillin; in the placebo group (n = 43), patients received preoperative placebo administration. Each patient was evaluated preoperatively, 2 days, and 7 days postoperatively. Factors evaluated were mouth opening amplitude, assessment of referred pain through a visual analogue scale, and characteristic signs of infection (presence of fistula, ulceration in the surgical wound, tissue necrosis at the edges of the wound, dehiscence of the surgical flap, and presence of purulent exudate in the surgical wound). Implant survival was evaluated until 90 days postsurgical procedure. Results showed that there were no statistically significant differences in postoperative healing, swelling, and pain. However, more loss of dental implants was observed in the placebo group (14.9% vs 2.3%). Use of antibiotic prophylaxis reduced implant loss that was previously placed by unexperienced operators.


Asunto(s)
Implantes Dentales , Herida Quirúrgica , Humanos , Amoxicilina/uso terapéutico , Antibacterianos/uso terapéutico , Profilaxis Antibiótica/métodos , Herida Quirúrgica/tratamiento farmacológico , Infección de la Herida Quirúrgica/prevención & control , Infección de la Herida Quirúrgica/tratamiento farmacológico , Método Doble Ciego
6.
Salud mil ; 42(2): e501, 20230929. ilus
Artículo en Español | LILACS, UY-BNMED, BNUY | ID: biblio-1531720

RESUMEN

En la actualidad es cada vez más frecuente la consulta de pacientes que siendo sometidos en edades tempranas a cirugías de extirpación tumoral y posterior reconstrucción con injertos presentan problemas tanto funcionales como estéticos, el uso de prótesis implantosoportadas mejora la calidad de vida, pero al mismo tiempo representan un desafío por la baja disponibilidad ósea. Se presenta un caso clínico de rehabilitación protésica implantosoportada en una paciente con gran déficit óseo mandibular como consecuencia de le extirpación de una neoplasia y posterior injerto de costilla. Se colocaron 2 implantes osteointegrados en hueso remanente y rehabilitación con prótesis removible sostenida a una barra colada. Por ser un tratamiento poco invasivo y conservador fue aceptado fácilmente por la paciente y la mejora tanto en la estética como en la función fue notoria.


Nowadays, it is becoming more and more frequent to see patients who underwent surgery for tumor removal and subsequent reconstruction with grafts at an early age, presenting both functional and esthetic problems. The use of implant-supported prostheses improves the quality of life, but at the same time represents a challenge due to the low availability of bone. A clinical case of implant-supported prosthetic rehabilitation is presented in a patient with a great mandibular bone deficit as a consequence of the removal of a neoplasm and subsequent rib graft. Two osseointegrated implants were placed in the remaining bone and rehabilitation with a removable prosthesis supported by a cast bar. Being a minimally invasive and conservative treatment, it was easily accepted by the patient and the improvement in both esthetics and function was notorious.


Atualmente, são cada vez mais frequentes os pacientes submetidos à cirurgia de remoção de tumores e posterior reconstrução com enxertos em idade precoce que apresentam problemas funcionais e estéticos. O uso de próteses implanto-suportadas melhora a qualidade de vida, mas, ao mesmo tempo, representa um desafio devido à baixa disponibilidade de osso. Apresentamos um caso clínico de reabilitação protética implanto-suportada em um paciente com grande déficit ósseo mandibular em consequência da remoção de uma neoplasia e posterior enxerto de costela. Dois implantes osseointegrados foram colocados no osso remanescente e a reabilitação foi feita com uma prótese removível suportada por uma barra de gesso. Por se tratar de um tratamento minimamente invasivo e conservador, foi facilmente aceito pelo paciente e a melhora na estética e na função foi perceptível.


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Costillas , Trasplante Autólogo , Trasplante Óseo , Implantación Dental Endoósea/métodos , Dentadura Parcial Removible , Procedimientos Quirúrgicos Orales/efectos adversos , Reconstrucción Mandibular/rehabilitación
7.
Materials (Basel) ; 16(13)2023 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-37444846

RESUMEN

E. faecalis has been associated with bacteremia, sepsis, and bacterial endocarditis and peri-implantitis. This microorganism can remain in the alveolus even after extraction of the root remnant. This study aimed to evaluate the corrosion on different surfaces of commercially pure titanium (Ti) grade 4 (Ticp-G4) as a function of the bacterial biofilm effect of Enterococcus faecalis. A total of 57 discs were randomly divided according to their surface finish (n = 19). For microbiological analysis (n = 9), the discs were placed in 12-well plates containing E. faecalis culture and incubated at 37 °C for 7 days. The results show that for the intergroup analysis, considering the "electrolyte" factor, there was a difference between the groups. There was greater biofilm formation for the D.A.Zir group, with greater electrochemical exchange for Biofilm, and the presence of biofilm favored greater electrochemical exchange with the medium.

8.
J. res. dent ; 11(1): 1-6, May 2023.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1513028

RESUMEN

The development of dental implants has revolutionized the rehabilitation possibilities for partially or totally edentulous patients. The long-term success of the dental implant depends on osseointegration and this is achieved by the combination of two essential stabilities: primary and secondary. Implant-supported prostheses are a great evolution for these treatments, positively interfering in the quality of life of the population, as they generate function and aesthetics for the patient. Thus, the present study aimed to radiographically evaluate complete dentures supported by an external hexagon conical implant in the anterior region of the mandible. More specifically, to evaluate the feasibility of using these implants in cortical bone of the mandible, to verify the success rate regarding the significance of peri-implant bone loss and to compare peri-implant bone loss between patients.

9.
Clin Ter ; 174(2): 180-184, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36920136

RESUMEN

Introduction: New techniques, surgical protocols, dental implant designs, and prosthetic rehabilitation have been used in dentistry, most of which have yielded good results in the literature. This retrospective survey assessed the clinical results of patients rehabilitated with dental implants between January 2011 and December 2021. Load protocols (immediate and conventional), types of connections of the installed implants, external hexagon (EH), and cone morse (MC) were evaluated. Material and methods: Two evaluators were selected and calibrated to perform the analyses. The inclusion criteria were records with complete and legible information of patients rehabilitated with dental implants who were followed for at least 1 year after rehabilita-tion. The medical records were divided into two groups, G1 (implants with conventional load) and G2 (implants with immediate load), and further subdivided according to implant type. Information about the rehabilitation failures was noted and descriptive statistics of the results were obtained. Results: Among the 432 evaluated medical records of patients rehabilitated with implants, the study included 319 records: 223 from women and 96 from men, aged 20-79 years. In total, data were available on 1,227 implants with dimensions of 10-13 mm and diameters of 3.75-4 mm. The G1 (n=1.188) survival rates were 94.95% for EH implants and 99.5% for MC implants. In G2 (n=39), the survival rates were 93.75% for EH implants and 91.3% for MC implants. The implant survival rates were relatively high among all groups evaluated; however, the discrepancy between the number of implants in the groups may compromise the comparison between them. Understanding and respecting the biomechanical and technical principles of each protocol was the main factor influencing the success of rehabilitation. Conclusion: The results of this study showed that, according to medical records, rehabilitation with dental implants showed excellent results regardless of the connection type (EH or MC) or loading protocol (conventional or immediate). The two loading protocols and two connection types had excellent results and scientific support. Therefore, the choice should be based on the clinical needs of each patient.


Asunto(s)
Prótesis Anclada al Hueso , Implantes Dentales , Masculino , Humanos , Femenino , Estudios Retrospectivos , Implantación Dental Endoósea , Estudios de Seguimiento
10.
Dent Traumatol ; 39(1): 88-94, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36129430

RESUMEN

This case report describes the successful 10-years interdisciplinary treatment of ankylosed upper central incisors with an anterior vertical ridge defect. This treatment was challenging as ankylosis was present before the growth spurt. Orthodontic treatment in association with decoronation, a xenogeneic bone graft, an autogenous sub-epithelial connective tissue graft, and implant placement were performed to correct the vertical ridge defect and to re-establish appropriate function, gingival health, and aesthetics. Decoronation performed during the growth spurt was the key to avoiding alveolar ridge deformity.


Asunto(s)
Aumento de la Cresta Alveolar , Anquilosis del Diente , Avulsión de Diente , Humanos , Proceso Alveolar , Incisivo/cirugía , Anquilosis del Diente/cirugía , Avulsión de Diente/terapia , Corona del Diente , Masculino , Niño
11.
Ortho Sci., Orthod. sci. pract ; 16(63): 85-91, 2023. ilus, tab
Artículo en Portugués | BBO - Odontología | ID: biblio-1518339

RESUMEN

Resumo A crista infrazigomática e buccal shelf possuem maior quantidade de osso corticalizado, que favorece a instalação de mini-implantes pela diminuição dos riscos de acidentes como também pelas maiores chances de estabilidade primária. Este trabalho tem como finalidade analisar a espessura óssea na região da crista infrazigomática e buccal shelf em diferentes tipos de padrões faciais por meio de tomografia computadorizada de feixe cônico, a fim de constatar a presença suficiente de osso corticalizado nessas regiões para inserção de mini- -implantes. A amostra de conveniência foi composta por 24 tomografias, divididas em três grupos: dolicofacial (G1), mesofacial (G2) e braquifacial (G3), as quais foram mensuradas no solfware ImplantViewer 3. O estudo envolveu duas variantes: padrão de crescimento vertical e espessura da cortical óssea na área da crista infrazigomática e da buccal shelf. 30% da amostra foi utilizada para realização do cálculo de reprodutibilidade e posteriormente a amostra completa foi submetida à análise de variância, seguido do teste de post-hoc Tukey HSD. Não houve interferência do padrão facial para a crista infrazigomática, entretanto, houve diferença estatística entre os grupos braquifaciais e dolicofaciais, como também entre os braquifaciais e mesofaciais no que diz respeito ao buccal shelf, nos quais os indivíduos braquifaciais mostraram maior espessura, seguido dos mesofaciais e dolicofaciais. Concluiu-se que os indivíduos pertencentes ao grupo braquifacial apresentaram maior espessura na região da buccal shelf quando comparados aos demais, e todos os grupos apresentaram espessura suficiente para segura instalação dos mini-implantes. (AU)


Abstract The infrazygomatic crest and buccal shelf have a greater amount of cortical bone, which favors the installation of mini-implants, reducing the risk of accidents as well as the greater chances of primary stability. This study aims to analyze bone thickness in the region of the infrazygomatic crest and buccal shelf in different types of facial patterns by means of conical beam computed tomography, in order to verify the presence of corticalized bone in these regions for insertion of mini-implants. The convenience sample consisted of 24 CT scans, divided into three groups: dolichofacial (G1), mesofacial (G2), and brachyfacial (G3), which were measured in the ImplantViewer 3 solfware. The study involved two variants: vertical growth and thickness of the cortical bone in the infrazygomatic ridge and buccal shelf area. 30% of the sample were used to perform the reproducibility calculation and afterwards the entire sample was submitted to analysis of variance, following Tukey HSD post-hoc test. There was no interference of the facial pattern for the infrazygomatic ridge, however, there was a statistical difference between the brachyphacal and dolicofacial groups, as well as between the brachyfacial and mesofacial groups with respect to buccal shelf, in which brachyfacial individuals showed greater thickness, followed by mesofacial ones and dolichofacials. It was concluded that individuals belonging to the brachyfacial group presented greater thickness in the buccal shelf region when compared to the others, and all groups presented sufficient thickness for the safe installation of the mini-implants. (AU)


Asunto(s)
Ortodoncia , Implantación Dental Subperióstica , Tomografía Computarizada de Haz Cónico
12.
Rev. odontol. UNESP (Online) ; 52: e20230027, 2023. tab, ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1530299

RESUMEN

Introdução: O conhecimento da biomecânica de implantes de diâmetro reduzido indica dimensões seguras para uso clínico. Objetivo: O objetivo do presente estudo foi comparar biomecanicamente implantes de diâmetro regular e reduzido para suporte de próteses implantossuportadas unitárias na região anterior da maxila por meio de análise de elementos finitos 3D (3D-FEA). Material e método: Quatro modelos 3D-FEA foram desenvolvidos a partir de recomposição de tomografia computadorizada e dados da literatura: um bloco ósseo na região incisiva lateral superior direita com implante e coroa. M1: 3,75 x 13 mm, M2: 3,75 x 8,5 mm, M3: 2,9 x 13 mm e M4: 2,9 x 8,5 mm. Foi aplicada carga de 178 N nos ângulos 0, 30 e 60 graus em relação ao longo eixo do implante. Foram avaliados mapas de tensão de Von Mises, tensão principal máxima e microdeformação. Resultado: M3 e M4 apresentaram maiores valores de tensão e microdeformação que M1 e M2, principalmente quando foram aplicadas forças inclinadas. Porém, M3 apresentou comportamento biomecânico melhor do que M4. Conclusão: Pode-se concluir que reduzir o diâmetro dos implantes pode prejudicar a biomecânica durante a aplicação de forças, mas a distribuição e intensidade das tensões, bem como os valores de microdeformação podem ser melhorados se o comprimento do implante for aumentado


Introduction: Narrow diameter implants biomechanics knowledge indicates safe dimensions for clinical use. Objective: Purpose of the present study was biomechanically to compare regular and narrow diameter implants to support single implant-supported prosthesis in the anterior region of the maxilla by 3D finite element analysis (3D-FEA). Material and method: Four 3D-FEA models were developed form CT scan recompositing and literature data: a bone block in the right upper lateral incisive region with implant and crown. M1: 3.75 x 13 mm, M2: 3.75 x 8.5 mm, M3: 2.9 x 13 mm and M4: 2.9 x 8.5 mm. It was applied load was of 178 N at 0, 30 and 60 degrees in relation to implant long axis. Von Mises stress, maximum principal stress and microdeformation maps were evaluated. Result: M3 and M4 did show higher tension and higher microdeformation values than M1 and M2, especially when inclined forces were applied. However, M3 presented enhanced biomechanical behavior than M4. Conclusion: It can be concluded that reduce the diameter of the implants can disadvantage to the biomechanics during the application of forces, but the distribution and intensity of the stresses, as well as the micro deformation values can be improved if the length of the implant is increased


Asunto(s)
Prótesis e Implantes , Estrés Mecánico , Fenómenos Biomecánicos , Huesos , Implantes Dentales , Análisis de Elementos Finitos , Tomografía Computarizada por Rayos X , Maxilar
13.
RGO (Porto Alegre) ; 71: e20230003, 2023. graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1422497

RESUMEN

ABSTRACT The immediate rehabilitation of the posterior region of the mandible with dental implants, expands the set of possible actions for the dental surgeon, in the face of tooth loss. The purpose of this study is to describe two cases of single rehabilitation of mandibular molars with hybrid internal tapered implants indicated for immediate loading in post-extraction socket, associated with the maintenance of the prosthetic and peri-implant space. Implants with macrogeometry and surface treatment (Hydrophilic) were used to optimize primary stability, as well as the type of internal connection and prosthetic abutments that allows better accommodation and healing of adjacent tissues, and protection of the bone graft. Different methodologies of surgical guides did not influence the final result. The predictability of associating techniques and components can be observed in the 2-year follow-up. The initial planning combined with the new technologies enable to achieve stable and functional final restorations.


RESUMO A reabilitação imediata da região posterior da mandíbula com implantes dentários, amplia o conjunto de ações possíveis ao cirurgião dentista, frente as perdas dentárias. O intuito desse estudo é descrever dois casos de reabilitação unitária de molares inferiores com implantes cônicos internos híbridos indicados para carregamento imediato em alvéolos pós-extração, associado a manutenção do espaço protético e peri-implantar. Foram utilizados implantes com macrogeometria e tratamento de superfície que otimizassem a estabilidade primária (Hidrofílicos), bem como o tipo de conexão interna e abutments protéticos que permitisse melhor acomodação e cicatrização dos tecidos adjacentes, e proteção do enxerto ósseo. Diferentes metodologias de guias cirúrgicos não influenciaram o resultado final. A previsibilidade da associação de técnicas e componentes pode ser observada no follow-up de 2 anos. O planejamento inicial aliado às novas tecnologias permite restaurações finais estáveis e funcionais.

14.
Braz. j. oral sci ; 21: e226999, jan.-dez. 2022. ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1392965

RESUMEN

Background: Tooth extraction socket in the aesthetic area is a major indication for immediate implant placement greatly improving patient satisfaction and preserving the alveolar ridge. However, the effect of non-axial force on the peri-implant bone with subsequent early implant failure remains unclear. Objective:Evaluate the prognosis of tilted implants immediately placed and restored with angled abutments in comparison to straight implants restored with straight abutments in the esthetic area (anterior or premolars) using computer-aided surgical guides. Material and methods: Badly decayed non-restorable teeth in the aesthetic zone (anterior or premolars) were extracted atraumatically. Immediately after guided implant insertion, the abutments were adjusted and placed according to the allocation group (0, 15, or 25-degree angle) then a temporary crown was performed out of occlusion in centric and eccentric relation. Early implant failure was assessed at three and six months. Results:There was no statistically significant difference between the two groups (P=0.305). Straight and angled abutment groups showed 6 (14.3%) and 8 (20%) failed cases, respectively. The post-hoc subgroup analysis showed no statistically significant difference between angle 15 and angle 25 degree groups where (P=0.686) or between Anterior and Premolar groups (P=0.853). Conclusion: There was no statistically significant difference in the failure rate when comparing angled to straight immediately placed & restored implants. This applies to both anterior and premolar implants


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Pronóstico , Extracción Dental , Soporte de Peso , Fracaso de la Restauración Dental , Implantación Dental , Carga Inmediata del Implante Dental
15.
Braz. j. oral sci ; 21: e226036, jan.-dez. 2022. ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1393321

RESUMEN

Dental implants could give back function, esthetics and quality of life to patients. The correct choice of the implant, especially in borderline cases, is essential for a satisfactory result. Aim: Thus, the objective of this study was to evaluate the mechanical behavior of Morse taper implants with two different prosthetic interfaces. Methods: Twenty self-locking Morse taper implants, 2.9 mm in diameter (FAC), and 20 Morse taper implants, 3.5 mm in diameter (CM) were divided into two groups (n=10), and submitted to strength to failure test, optical microscopic evaluation of fracture, metallographic analysis of the alloy, finite element analysis (FEA) and strain gauge test. A Student's t test (α = 0.05) was made for a statistical analysis. Results: For the strength to failure test, a statistically difference was observed (p <0.001) between FAC (225.0 ± 19.8 N) and CM (397.3 ± 12.5 N). The optical microscopic evaluation demonstrated a fracture pattern that corroborated with FEA ́s results. The metallographic analysis determined that the implants of the FAC group have titanium-aluminum-vanadium alloy in their composition. In the strain gauge test, there was no statistical difference (p = 0.833) between CM (1064.8 ± 575.04 µS) and FAC (1002.2 ± 657.6 µS) groups. Conclusion: Based on the results obtained in this study, ultra-narrow implants (FAC) should ideally be restricted to areas with low masticatory effort


Asunto(s)
Resistencia a la Tracción , Implantación Dental , Resistencia Flexional
16.
Natal; s.n; 9 nov 2022. 158 p. tab, ilus, graf.
Tesis en Portugués | LILACS, BBO - Odontología | ID: biblio-1532385

RESUMEN

Este estudo objetivou identificar os fatores que influenciam na decisão de substituir uma prótese total convencional mandibular pelo tratamento com implantes dentários, assim como avaliar a satisfação, qualidade de vida e performance mastigatória (PM) após reabilitação com sobredentaduras com implante único (SIU) em pacientes adaptados e não-adaptados a prótese total convencional (PT) mandibular. Inicialmente, foi realizado um estudo transversal com 117 usuários de PTs bimaxilares, avaliados quanto aos desfechos relacionados à prótese (número de PTs mandibulares usadas previamente, tempo de uso e profissional que confeccionou a prótese atual, e quanto ao uso regular ou não da prótese mandibular) e aspectos centrados no paciente (período de edentulismo mandibular, altura óssea mandibular e interesse do paciente em se submeter a terapia com implantes). Do total da amostra, 78 pacientes manifestaram interesse na terapia implantossuportada, e desses apenas 22 foram selecionados e reabilitados com novas PTs bimaxilares. Após critérios de elegibilidade, foram alocados após pareamento em 2 grupos: adaptados à prótese mandibular (Grupo PTA - "adaptados à PT mandibular", n:10) e não adaptados (Grupo PTN - "não adaptados à PT mandibular", n:12). Em cada paciente, foi instalado um único implante na linha média e após o período de osseointegração as próteses mandibulares foram convertidas em sobredentaduras. O desempenho mastigatório foi avaliado pelo método das tamises, a altura óssea mandibular por medição em radiografia panorâmica, satisfação por escala quantitativa com questionário validado e o impacto da saúde oral na qualidade de vida pelo questionário OHIP-Edent-19. O teste Qui-quadrado foi utilizado para análise dos dados e as razões de prevalência ajustadas por meio da regressão multivariada de Poisson no primeiro estudo; para o segundo, a análise estatística em cada grupo e entre grupos foi baseada nos testes não-paramétricos de Wilcoxon e Mann-Whitney. O intervalo de confiança para os testes foi de 95%. A amostra foi predominantemente do sexo feminino, com 66,7% (n=78) dos participantes interessados em PT mandibular implantossuportada e com idade média de 65,68±6,38 anos. A PM não influenciou a escolha pela reabilitação com implantes. A preferência pela PT implantossuportada mandibular foi associada significativamente com maior experiência prévia com PT mandibular (p=0,021) e à insatisfação quanto à retenção (p=0,005). Após a intervenção com implante, todos os pacientes não adaptados passaram a condição de adaptados. Não houve diferença entre PTA e PTN para OHIP-Edent (p=0,276) e PM (p=0,222), a satisfação foi significativa apenas para o critério "conforto em arco inferior" (p=0,043). Para comparações pré e pós-tratamento com sobredentadura, a mediana do OHIP-Edent total diminuiu significativamente em ambos os grupos. Na comparação intragrupo, essa redução foi significativa em PTA apenas para a "limitação funcional" (p=0,026), e em PTN em quase todos os domínios, exceto "disfunção social" e "incapacidade" (p>0,05). Houve aumento estatisticamente significativo para a satisfação geral de 75,41 para 90,25 (p=0,012) em PTN e de 76,10 para 90,50 (p=0,007) em PTA. Os parâmetros "mastigação", "adaptação", "retenção" e "conforto" em arco inferior foram diferentes com significância em ambos os grupos, e "gustação", "fonação" e "dor" em arco inferior foram significativos apenas para o grupo não adaptado (p<0,05). Houve diferença significativa para PM em PTN (p=0,002) e PTA (p=0,047) ao se comparar tipo de reabilitação. Não houve correlação entre PM e OHIP antes e após a reabilitação (p>0,05). Pode-se concluir que a experiência prévia com PT mandibulares convencionais e a insatisfação com a retenção dessas, influenciam o interesse pela reabilitação com sobredentadura implantossuportada mandibular, assim como, a reabilitação com sobredentadura sobre implante único apresenta-se como alternativa aos pacientes não adaptados a PT convencional mandibular, auxiliando na aceitação do uso da prótese mandibular, assim como, comprovando efeito positivo na satisfação, qualidade de vida e performance mastigatória (AU).


This study aimed to identify the factors that influence the decision to replace a conventional mandibular complete denture by treatment with dental implants, as well as to evaluate satisfaction, quality of life and masticatory performance (MP) after rehabilitation with overdentures with a single implant in patients adapted and not adapted to conventional mandibular complete denture (CD). Initially, a cross-sectional study was carried out with 117 users of bimaxillaries CDs, who were evaluated for outcomes related to the denture (number of previous mandibular CDs, time of use and professional who made the current denture, and regarding regular use of the mandibular denture) and aspects centered patients (period of mandibular edentulism, mandibular bone height and the patient's willingness to undergo implant therapy). From the total sample, 78 patients expressed interest in implant-supported therapy, and of these, only 22 were selected and rehabilitated with new bimaxillary CDs. After eligibility criteria, they were allocated after pairing into 2 groups: adapted to mandibular prosthesis (PTA Group - "adapted to mandibular CD", n:10) and non-adapted (PTN Group - " not adapted to mandibular CD", n:12). In each patient, a single implant was installed in the midline and after the osseointegration period, the mandibular prostheses were converted into overdentures. Masticatory performance was evaluated by the sieve method, mandibular bone height by paranoid radiographic measurement, satisfaction by quantitative scale with a validated questionnaire and the impact of oral health on quality of life by the OHIP-Edent-19 questionnaire. The chi-square test was used for data analysis and the prevalence ratios adjusted by means of multivariate Poisson regression in the first study; on the second, the statistical analysis in each group and between groups was based on the non-parametric-Wilcoxon and Mann-Whitney tests. The confidence interval for the tests was 95%. The sample was composed predominantly by women, with 66.7% (n=78) of the participants interested in implantsupported mandibular CD, with mean age 65.68±6.38 years. MP was not influenced by the choice by dental implants rehabilitation. Preference for mandibular implant-supported CD was significantly associated with longer previous experience in mandibular CD (p=0.021) and with dissatisfaction regarding retention (p=0.005). After the implant intervention, all non-adapted patients became adapted. There was no difference between PTA and PTN for OHIP-Edent (p=0.276) and MP (p=0.222), satisfaction was significant only for the criteria "comfort in the lower arch" (p=0.043). For pre- and post-treatment comparisons with overdentures, the median total OHIP-Edent decreased significantly in both groups. In the intragroup comparison, this reduction was significant in PTA only for "functional limitation" (p=0.026), and in PTN in almost all domains, except "social dysfunction" and "disability" (p>0.05). There was a statistically significant increase in overall satisfaction from 75.41 to 90.25 (p=0.012) in PTN and from 76.10 to 90.50 (p=0.007) in PTA. The parameters "chewing", "adaptation", "retention" and "comfort" in the lower arch were significantly different in both groups, and "gustation", "phonation" and "pain" in the lower arch were significant only for the group not adapted (p<0.05). There was a significant difference for MP in PTN (p=0.002) and PTA (p=0.047) when comparing the type of rehabilitation. There was no correlation between MP and OHIP before and after rehabilitation (p>0.05). It can be concluded that the previous experience with conventional mandibular CD and the dissatisfaction with the retention of these, influence the rehabilitation with mandibular implant-supported overdenture, as well as the rehabilitation with overdenture on single implant presents itself as an alternative for patients not adapted to mandibular conventional CD, helping to accept the use of mandibular prosthesis, as well as proving a positive effect on satisfaction, quality of life and masticatory performance (AU).


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Calidad de Vida , Dentadura Completa , Masticación , Rehabilitación Bucal , Estudios Transversales/métodos , Satisfacción del Paciente , Estadísticas no Paramétricas , Implantación de Prótesis Mandibular , Implantación Dental , Carga Inmediata del Implante Dental
17.
J. oral res. (Impresa) ; 11(2): 1-28, may. 23, 2022. tab
Artículo en Inglés | LILACS | ID: biblio-1400827

RESUMEN

Introduction: There are multiple techniques for vertical bone augmentation. Guided bone regeneration is one of them; however, the literature is diverse and includes different study designs, which makes it difficult to synthesize results. Objective: To analyze the general technical characteristics, clinical results, and complications of vertical bone augmentation performed with guided bone regeneration in humans. Material and Methods: This scoping review was based on the PRISMA-ScR guidelines. A search was performed in the Pubmed, Scielo, and Worldcat databases. Papers published from 1990 to April 2020 were included in the study. Research articles not conducted in humans or published in languages other than English and Spanish were excluded. Title and abstract were screened by two reviewers, then full studies were extracted, and data tabulated. Results: 89 studies were included. The highest percentage reported having obtained a vertical bone increase of less than 5 mm and having used non-resorbable membranes. The most frequent type of graft is autogenous and combinations of grafts, the most common being autogenous with xenograft. All studies that reported bone stability of implants in regenerated bone were favorable, as was implant survival, reporting values between 83.8% and 100%. Membrane exposure is the most frequently reported complication, followed by infection or abscesses, and tissue dehiscence. Conclusion: Vertical bone regeneration is a reliable technique, with high predictability and low incidence of complications compared to other vertical bone augmentation techniques.


Introducción: Existen múltiples técnicas para el aumento óseo vertical siendo una opción la regeneración ósea guiada, sin embargo, la literatura es diversa y con distintos diseños que dificultan la síntesis de resultados. Objetivo: Analizar las características generales técnicas, resultados clínicos y complicaciones del aumento óseo vertical realizado con regeneración ósea guiada en humanos. Material y Métodos: Esta revisión de alcance se basó en la guía PRISMA-ScR. Se realizó una búsqueda en las bases de datos Pubmed, Scielo y Worldcat. Fueron incluidos aquellos publicados desde el año 1990 hasta abril de 2020. Se excluyeron los estudios no realizados en humanos o publicados en idiomas distintos al inglés y español. Dos revisores examinaron título y resumen, luego los estudios completos se extrajeron y se ordenaron los datos en tablas. Resultados: 89 estudios fueron incluidos. El mayor porcentaje reportó haber obtenido un aumento óseo vertical menor a 5 mm y haber utilizado membranas no reabsorbibles. El tipo de injerto que más frecuente es el autógeno y las combinaciones de injertos, siendo el más común autógeno con xenoinjerto. Todos los estudios que reportaron estabilidad ósea de implantes en hueso regenerado fueron favorables, al igual que la supervivencia de implantes, reportando valores entre 83,8% y 100%. La exposición de membrana es la complicación que más se repite en los estudios, seguido por infección o abscesos y dehiscencia de tejidos. Conclusión: La regeneración ósea vertical es una técnica confiable, con alta predictibilidad y baja incidencia de complicaciones en comparación a otras técnicas de aumento óseo vertical.


Asunto(s)
Humanos , Regeneración Ósea , Implantes Dentales , Regeneración Tisular Guiada Periodontal , Aumento de la Cresta Alveolar/métodos , Pérdida de Hueso Alveolar , Trasplantes , Proceso Alveolar
18.
J Oral Implantol ; 48(4): 307-311, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-34091685

RESUMEN

This paper reports on an infected silicone chin implant due to the nonideal placement of dental implants, in a female patient aged 67 years old. A patient unsatisfied with her facial profile had received a silicone chin implant 25 years ago and had recently undergone surgery for placement of dental implants in a region close to the silicone implant. The nonideal positioning of dental implants and close contact with the silicone implant led to the absence of osseointegration, with consequent mobility and infection of both. The mobile dental implants and silicone implant were removed. Imaging exams revealed other complications of the silicone implant as bone resorption and formation of a narrow bone layer around the inferior silicone implant border. Alloplastic implants are an option for the esthetic correction of chin deformities. Solid silicone is biocompatible and highly resistant to degradation, with minimal allergic reaction and risk of toxicity. However, several postoperative complications may arise, such as migration or displacement, extrusion, foreign body reaction, bone resorption, heterotopic bone formation, and infection. Precise imaging exams are critical for diagnosis and to indicate the best treatment plan.


Asunto(s)
Resorción Ósea , Implantes Dentales , Anciano , Mentón/cirugía , Estética Dental , Femenino , Humanos , Siliconas
19.
Braz. dent. sci ; 25(4): 1-7, 2022. tab, ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1396066

RESUMEN

Objective: The aim of this study was to evaluate the transcrestal sinus lift using Osseodensification technique with simultaneous implant placement. Material and Methods: In this case series 7 patients who needed implant placement in the atrophic posterior maxilla were enrolled. In all the cases the residual bone height between the sinus floor and the alveolar crest was 4-6 mm. Transcrestal sinus lift was performed using Osseodensification with simultaneous implant placement. Cone-beam computed tomography (CBCT) were obtained immediately postoperative and 6 months after operation. Implant stability using Osstell® were assessed at the time of implant placement and implant exposure (6 months). Results: The results showed that the mean bone height gain was 5.33±0.83mm at 6 months postoperatively. Mean bone density value was 818.43±109.63 HU. Mean ISQ value was 80.00±3.11 at 6 months postoperatively. The duration of surgical procedure (minutes) ranged between 25-38 minutes with an average of 30.86±4.10 minutes. Conclusion: The crestal maxillary sinus floor elevation using Osseodensification technique with simultaneous implant placement provide superior results regarding bone density and implant stability and less duration of surgical procedure. (AU)


Objetivo: O objetivo deste estudo foi avaliar a elevação de seio maxilar via crista do rebordo com a técnica de Osseodensificação com instalação simultânea de implante. Material e Métodos: Nesta série de casos, participaram 7 pacientes que necessitavam de implantes em região posterior de maxila atrófica. Em todos os casos a altura de remanescente ósseo entre o soalho do seio e a crista alveolar estava entre 4 a 6 mm. A elevação de seio maxilar via crista do rebordo foi realizada com osseodensificação com instalação simultânea de implante. As Tomografias Computadorizadas Cone Beam (TCCB) foram obtidas imediatamente após a cirurgia e 6 meses depois. A estabilidade dos implantes utilizando Osstell® foi avaliada no momento da instalação do implante e no momento da reabertura (6 meses). Resultados: Os resultados mostraram que a média de ganho de altura óssea foi de 5.33±0.83mm após 6 meses da cirurgia. A média da densidade óssea foi de 818.43±109.63 HU. A média de ISQ foi de 80.00±3.11 após 6 meses da cirurgia. A duração do procedimento cirúrgico (minutos) foi entre 25 a 38 minutos com uma média de 30.86±4.10 minutos. Conclusão: A elevação do soalho de seio maxilar via crista do rebordo com instalação simultânea de implante utilizando osseodensificador promove resultados superiores em relação à densidade óssea, estabilidade do implante e menor duração do tempo cirúrgico (AU)


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Osteotomía , Pérdida de Hueso Alveolar , Sustitutos de Huesos , Implantación Dental , Tomografía Computarizada de Haz Cónico , Elevación del Piso del Seno Maxilar
20.
Pesqui. bras. odontopediatria clín. integr ; 22: e210131, 2022. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1365225

RESUMEN

Abstract Objective: To analyze and compare changes of quality of life parameter among dental patients rehabilitated by the implant-supported overdentures with different attachment systems. Material and Methods: Forty-eight patients were recruited as a study cohort. The implant placement procedure was based on the results obtained by CBCT scanning and individualized surgical templates manufactured for correct implant placement. Each individual received two k3Pro Implants (Sure Type with 4.0 or 4.5 mm in diameter) at the intraforaminal area due to standard protocol of implantation provided by the manufacturer under local anesthesia. All patients were distributed between two groups based on the fact of using either Locator- or ball-attachments. Rank correlation was measured using Spearman correlation coefficient, while linear correlation was evaluated by Pearson correlation coefficient. Results: No statistically meaningful differences were noted regarding patients' distribution among groups considering age (p>0.05) and gender (p>0.05). Provided patient-level analysis demonstrated that increase of conventional full denture service time was positively correlated with escalation of OHIP-EDENT scores. The most prominent inter-correspondences were noted specifically between longevity of denture service and elevation of scores within "Functional limitation" (r=0.61; p<0.05), "Physical pain" (r=0.51; p<0.05) and "Physical disability" (r=0.57; p<0.05) subdomains. No statistically argumented regressions were noted between increase tendency of OHIP-EDENT scores and gender (p>0.05) or age (p>0.05) parameters. Conclusion: Significant improvements of quality of life measured with OHIP-EDENT were noted for both types of attachments compared to the pre-treatment situation independently of additionally provided surface electromyography-based alignment.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Calidad de Vida , Prótesis Dental de Soporte Implantado/instrumentación , Electromiografía/instrumentación , Músculos Masticadores , Ucrania , Encuestas y Cuestionarios , Análisis de Regresión , Estudios de Cohortes , Estadísticas no Paramétricas , Ajuste Oclusal , Adaptación a Desastres , Implantación Dental , Dentadura Completa , Prótesis de Recubrimiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA