Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Neuromuscul Dis ; 11(3): 613-623, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38578899

RESUMEN

Background/Objective: Myasthenia Gravis (MG) is an autoimmune disorder characterized by pathogenic autoantibodies (AAbs) targeting nicotinic acetylcholine receptors (AChR), disrupting neuromuscular communication. RadioImmunoPrecipitation Assay (RIPA) is recommended to detect AChR AAbs, but its complexity and radioactive requirements limit widespread use. We compare non-RIPA anti-AChR immunoassays, including Cell-Based Assay (CBA) and two ELISA kits, against the gold standard RIPA. Methods/Results: 145 samples were included with medical indication for anti-AChR testing. By the RIPA method, 63 were negative (RIPA-Neg < 0.02 nmol/L), 18 were classified as Borderline (≥0.02 -1 nmol/L), and 64 were positive (RIPA-Pos > 1 nmol/L). The competitive ELISA showed poor agreement with RIPA (Kappa = 0.216). The indirect ELISA demonstrated substantial agreement with RIPA (Kappa = 0.652), with ∼76% sensitivity and ∼94% specificity for MG diagnostic. The CBA, where fixed cells expressing clustered AChR were used as substrate, exhibited almost perfect agreement with RIPA (Kappa = 0.984), yielding ∼98% sensitivity and 96% specificity for MG. In addition, a semiquantitative analysis showed a strong correlation between CBA titration, indirect ELISA, and RIPA levels (r = 0.793 and r = 0.789, respectively). Conclusions: The CBA displayed excellent analytical performance for MG diagnostic when compared to RIPA, making it a potential replacement for RIPA in clinical laboratories. Some solid-phase assays (such as the indirect ELISA applied here), as well as CBA titration, offer reliable options to estimate anti-AChR AAb levels after confirming positivity by the CBA.∥.


Asunto(s)
Autoanticuerpos , Ensayo de Inmunoadsorción Enzimática , Miastenia Gravis , Ensayo de Radioinmunoprecipitación , Humanos , Ensayo de Inmunoadsorción Enzimática/métodos , Miastenia Gravis/inmunología , Miastenia Gravis/diagnóstico , Sensibilidad y Especificidad , Receptores Colinérgicos/inmunología , Femenino , Masculino , Persona de Mediana Edad , Adulto , Anciano , Adulto Joven
2.
Front Immunol ; 13: 1011110, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36225928

RESUMEN

Anti-fibrillarin autoantibodies are useful for the diagnosis and prognosis of systemic sclerosis (SSc). Anti-fibrillarin produces a clumpy nucleolar pattern in indirect immunofluorescence assay on HEp-2 cells (HEp-2 IFA). Here we develop and validate a reliable cell-based anti-fibrillarin assay (Fibrillarin/CBA) for use in clinical diagnostic laboratories. A TransMembrane Signal was fused to the human fibrillarin gene (TMS-fibrillarin). HEp-2 cells overexpressing transgenic TMS-fibrillarin at the cytoplasmic membrane were used as IFA substrate in the Fibrillarin/CBA. Sixty-two serum samples with nucleolar pattern in the HEp-2 IFA (41 clumpy; 21 homogeneous/punctate) were tested for anti-fibrillarin using Fibrillarin/CBA, immunoprecipitation (IP), line-blot and ELISA. In addition, samples from 106 SSc-patients were evaluated with Fibrillarin/CBA and the results were correlated with disease phenotypes. Thirty-eight of 41 samples with the clumpy nucleolar pattern (92.7%) were positive in the Fibrillarin/CBA, while all 21 samples with other nucleolar patterns were negative. Fibrillarin/CBA results agreed 100% with IP results. Among the 38 Fibrillarin/CBA-positive samples, only 15 (39.5%) and 11 (29%) were positive for anti-fibrillarin in line-blot and ELISA, respectively. Higher frequency of diffuse cutaneous SSc (dcSSc) phenotype (72.7% vs 36.8%; p=0.022), cardiac involvement (36.4% vs 6.5%; p=0.001) and scleroderma renal crisis (18.2% vs 3.3% p = 0.028) was observed in SSc patients with positive compared to negative Fibrillarin/CBA result. Performance of Fibrillarin/CBA in the detection of anti-fibrillarin autoantibodies was comparable to the gold standard IP. Positive Fibrillarin/CBA results correlated with disease phenotypes known to be associated with anti-fibrillarin autoantibodies, underscoring the clinical validation of this novel assay.


Asunto(s)
Autoanticuerpos , Esclerodermia Sistémica , Ensayo de Inmunoadsorción Enzimática , Técnica del Anticuerpo Fluorescente Indirecta , Humanos , Inmunoprecipitación , Esclerodermia Sistémica/diagnóstico
3.
Front Immunol ; 12: 642272, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34025652

RESUMEN

Human antibodies against Myelin Oligodendrocyte Glycoprotein (MOG) from immunoglobulin-G subclasses (MOG-IgG) have been recently associated with a new subgroup of neurological autoimmune diseases with distinct clinical characteristics from multiple sclerosis and neuromyelitis optica spectrum disorders. The use of MOG-IgG as a biomarker is an essential tool to assist in the diagnosis and clinical prognosis. The cell-based assay (CBA) is a methodology that expresses high levels of natively folded human MOG protein in the cell membrane being the methodology most used for clinical MOG-IgG diagnosis. However, there is still no consensus about the best approach to perform CBA to improve the results. The CBA using flow cytometry (CBA-FC) is an automated technique with objective quantification, reducing the subject of human bias that occurred at CBA using immunofluorescence (CBA-IF). In this study, we compared the performance of CBA-IF and CBA-FC as an acquisition tool analysis. The sera of 104 patients diagnosed with inflammatory Central Nervous System diseases were tested in both CBA-IF and CBA-FC. We used the dilution of 1:128 for CBA-IF and three different dilutions (1:20, 1:100, and 1:640) for CBA-FC. The CBA-FC and CBA-IF results had 88.5% agreement between assays and the CBA-IF titers by endpoint-dilution correlated with the CBA-FC titers. The highest serum dilution resulted in an increased CBA-FC specificity, but there was a reduction in the CBA-FC sensitivity. Our study showed that CBA-FC can be used in clinical practice as a diagnostic technique for MOG-IgG. In addition, in some specific cases, the combination of both techniques could be used as a tool to discriminate unspecific binding and overcome single assay limitations.


Asunto(s)
Autoanticuerpos/sangre , Enfermedades Autoinmunes del Sistema Nervioso/diagnóstico , Citometría de Flujo/métodos , Inmunoglobulina G/sangre , Microscopía Fluorescente/métodos , Glicoproteína Mielina-Oligodendrócito/inmunología , Adulto , Autoantígenos/inmunología , Enfermedades Autoinmunes del Sistema Nervioso/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad
4.
Future Med Chem ; 12(16): 1489-1503, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32772556

RESUMEN

Aim: Although bacterial resistance is a growing concern worldwide, the development of antibacterial drugs has been steadily decreasing. One alternative to fight this issue relies on reducing the bacteria virulence without killing it. PhzS plays a pivotal role in pyocyanin production in Pseudomonas aeruginosa. Results: A total of 31 thiazolidinedione derivatives were evaluated as putative PhzS inhibitors, using thermo shift assays. Compounds that significantly shifted PhzS's Tm had their mode of inhibition (cofactor competitor) and affinity calculated by thermo shift assays as well. The most promising compound (E)-5-(4-((4-oxo-3-phenyl-3,4-dihydroquinazolin-2-yl)methoxy)benzylidene)thiazolidine-2,4-dione had their affinity confirmed by microscale thermophoresis (Kd = 18 µM). Cellular assays suggest this compound reduces pyocyanin production in vitro, but does not affect P. aeruginosa viability. Conclusion: The first inhibitor of PhzS is described.


Asunto(s)
Antibacterianos/farmacología , Pseudomonas aeruginosa/efectos de los fármacos , Piocianina/antagonistas & inhibidores , Antibacterianos/síntesis química , Antibacterianos/química , Relación Dosis-Respuesta a Droga , Pruebas de Sensibilidad Microbiana , Modelos Moleculares , Estructura Molecular , Pseudomonas aeruginosa/citología , Pseudomonas aeruginosa/metabolismo , Piocianina/biosíntesis , Relación Estructura-Actividad
5.
Artículo en Inglés | MEDLINE | ID: mdl-31638869

RESUMEN

There are two official PSP detection methods (mouse bioassay and HLPC-FLD) and a number of alternative methods. Ethical considerations have led to regulations being adopted in some countries that limit or prohibit the application of mouse bioassay. Analytical methodologies (e.g. HPLC-FLD or LC-MSMS) have the disadvantages of not being able to detect new toxins or analogues or reflecting the overall toxicity of the sample. In addition, they require highly trained personnel and expensive equipment, which are not always available. In this work, we have evaluated a method based on the Neuro-2a cell-based assay to detect substances that inhibit voltage-dependent sodium channels (Manger's method). We tested PSP standards and natural samples contaminated with PSP. Here we demonstrate that the adapted Manger's method is suitable for calculating Toxicity Equivalency Factors (TEF) for STX-analogues. The method was shown to be useful for screening contaminated natural samples in concentrations above the regulatory limit for these toxins (80 µg STX equivalents/100 g shellfish). We were able to detect PSP in 19 natural mollusc samples from South Chile despite the presence of other marine toxins. These preliminary results suggest that the method could be used as a first step in screening programmes.


Asunto(s)
Análisis de los Alimentos , Contaminación de Alimentos/análisis , Saxitoxina/análisis , Saxitoxina/toxicidad , Alimentos Marinos/análisis , Alimentos Marinos/toxicidad , Animales , Línea Celular , Supervivencia Celular/efectos de los fármacos , Chile , Relación Dosis-Respuesta a Droga , Ratones , Mariscos , Intoxicación por Mariscos
6.
Mult Scler ; 25(14): 1907-1914, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-30417715

RESUMEN

BACKGROUND: MOG-IgG-associated optic neuritis, encephalitis and myelitis (MONEM) is a recently recognized group of inflammatory central nervous system (CNS) disorders distinct from multiple sclerosis and neuromyelitis optica spectrum disorders. Limited data are available regarding the predictors of relapse in this condition. OBJECTIVE: We aimed to evaluate the longitudinal serostatus of patients with MOG-IgG and to correlate serostatus with long-term clinical outcomes. METHODS: Of 574 consecutive patients who presented with demyelinating inflammatory CNS disorders, we included 31 patients who were MOG-IgG-positive. Patients with MOG-IgG were followed up from 2011 to 2017 at the School of Medicine, University of São Paulo, Brazil. RESULTS: Relapsing disease occurred in 23 out of 31 patients (74%), while 8 (26%) exhibited a monophasic course. All monophasic patients, as well as the majority of relapsing patients, became seronegative during clinical remission. Patients exhibiting disease activity in the last 2 years were more likely to remain positive, with higher medium titres than those found in patients in clinical remission. CONCLUSION: MOG-IgG patients usually present with a relapsing course, and the risk of relapse was associated with longitudinally persistent MOG-IgG seropositivity. In contrast, patients who experienced a single attack became spontaneously seronegative for MOG-IgG during long-term follow-up.


Asunto(s)
Enfermedades Autoinmunes Desmielinizantes SNC/inmunología , Encefalitis/inmunología , Inmunoglobulina G , Glicoproteína Mielina-Oligodendrócito/inmunología , Mielitis/inmunología , Neuritis Óptica/inmunología , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Adulto Joven
7.
Artículo en Inglés | MEDLINE | ID: mdl-27002718

RESUMEN

Detecting marine biotoxins such as paralytic shellfish toxins (PSTs) is essential to ensuring the safety of seafood. The mouse bioassay is the internationally accepted method for monitoring PSTs, but technical and ethical issues have led to a search for new detection methods. The mouse neuroblastoma cell-based assay (Neuro-2a CBA) using ouabain and veratridine (O/V) has proven useful for the detection of PSTs. However, CBAs are sensitive to shellfish-associated matrix interferences. As the extraction method highly influences matrix interferences, this study compared three extraction protocols: Association of Official Analytical Chemists (AOAC) 2005.06, AOAC 2011.02 and an alternative liquid-liquid method. These methods were used to assess the matrix effect of extracts from four commercially important bivalve species (Chilean mussel, Magellan mussel, clam and Pacific oyster) in Neuro-2a CBA. Extracts from all three protocols caused a toxic effect in Neuro-2a cells (without O/V) when tested at a concentration of 25 mg of tissue-equivalent (TE) ml(-1). The greatest toxicity was obtained through the AOAC 2011.02 protocol, especially for the Chilean mussel and Pacific oyster extracts. Similar toxicity levels (less than 15%) were observed in all extracts at 3.1 mg TE ml(-1). When assessed in Neuro-2a CBA, AOAC 2005.06 extracts presented the lowest matrix interferences, while the highest interferences were observed for AOAC 2011.02 in Magellan mussel and clam extracts. Finally, the AOAC 2005.06 and alternative protocols were compared using Chilean mussel samples fortified with 40 and 80 µg STX per 100 g meat. The AOAC 2005.06 method demonstrated better results. In conclusion, the AOAC 2005.06 extracts exhibited the fewest interferences in the Neuro-2a CBA. Therefore, this extraction method should be considered for the implementation of Neuro-2a CBA as a high-throughput screening methodology for PST detection.


Asunto(s)
Bivalvos/química , Matriz Extracelular/química , Contaminación de Alimentos , Inspección de Alimentos/métodos , Toxinas Marinas/análisis , Neuronas/efectos de los fármacos , Mariscos/análisis , Alternativas a las Pruebas en Animales , Animales , Bivalvos/metabolismo , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Chile , Matriz Extracelular/metabolismo , Contaminación de Alimentos/prevención & control , Ensayos Analíticos de Alto Rendimiento , Extracción Líquido-Líquido , Toxinas Marinas/biosíntesis , Toxinas Marinas/toxicidad , Ratones , Neuronas/patología , Reproducibilidad de los Resultados , Saxitoxina/análisis , Saxitoxina/biosíntesis , Saxitoxina/toxicidad , Mariscos/efectos adversos , Intoxicación por Mariscos/etiología , Intoxicación por Mariscos/patología , Intoxicación por Mariscos/prevención & control , Especificidad de la Especie , Extractos de Tejidos/análisis , Extractos de Tejidos/aislamiento & purificación , Extractos de Tejidos/toxicidad
8.
Environ Res ; 143(Pt B): 100-8, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26409497

RESUMEN

From 2010 to 2012, 35 ciguatera fish poisoning (CFP) events involving 87 individuals who consumed locally-caught fish were reported in Guadeloupe (French West Indies). For 12 of these events, the presence of ciguatoxins (CTXs) was indicated in meal remnants and in uncooked fish by the mouse bioassay (MBA). Caribbean ciguatoxins (C-CTXs) were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Using a cell-based assay (CBA), and the only available standard Pacific ciguatoxin-1 (P-CTX-1), the lowest toxins level detected in fish samples causing CFP was 0.022 µg P-CTX-1 equivalent (eq.)·kg(-1) fish. Epidemiological and consumption data were compiled for most of the individuals afflicted, and complete data for establishing the lowest observable adverse effects level (LOAEL) were obtained from 8 CFP events involving 21 individuals. Based on toxin intakes, the LOAEL was estimated at 4.2 ng P-CTX-1 eq./individual corresponding to 48. 4 pg P-CTX-1 eq.kg(-1) body weight (bw). Although based on limited data, these results are consistent with the conclusions of the European Food Safety Authority (EFSA) opinion which indicates that a level of 0.01 µg P-CTX-1 eq.kg(-1) fish, regardless of source, should not exert effects in sensitive individuals when consuming a single meal. The calculated LOAEL is also consistent with the U.S. Food and Drug Administration guidance levels for CTXs (0.1 µg C-CTX-1 eq.kg(-1) and 0.01 µg P-CTX-1 eq.kg(-1) fish).


Asunto(s)
Intoxicación por Ciguatera/inducido químicamente , Ciguatoxinas/análisis , Ciguatoxinas/toxicidad , Peces/metabolismo , Alimentos Marinos/análisis , Alimentos Marinos/toxicidad , Animales , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Intoxicación por Ciguatera/epidemiología , Relación Dosis-Respuesta a Droga , Guadalupe , Humanos , Masculino , Ratones , Pruebas de Toxicidad/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA