Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros











Intervalo de año de publicación
1.
Arch. cardiol. Méx ; Arch. cardiol. Méx;90(1): 12-16, Jan.-Mar. 2020. graf
Artículo en Inglés | LILACS | ID: biblio-1131000

RESUMEN

Abstract Complete heart block (CHB) results from dysfunction of the cardiac conduction system, which results in complete electrical dissociation. The ventricular escape rhythm can have its origin anywhere from the atrioventricular node to the bundle branch-Purkinje system. CHB typically results in bradycardia, hypotension, fatigue, hemodynamic instability, syncope, or even Stokes-Adams syndrome. Escape rhythm originating above the bifurcation of the His bundle (HB) produces narrow QRSs with relatively rapid heart rate (HR) (except in cases of His system disease). We present a middle-aged man with an HR of 34 bpm, progressive fatigue, in whom a temporary pacemaker was implanted in the subtricuspid region. The post-intervention electrocardiogram had unusual features.


Resumen El bloqueo cardíaco completo (BCC) resulta de la disfunción del sistema de conducción cardíaco, lo que ocasiona una disociación eléctrica completa entre aurículas y ventrículos. El ritmo de escape resultante puede tener su origen en cualquier lugar desde el nodo auriculoventricular hasta el sistema His Purkinje. El BCC generalmente produce bradicardia, hipotensión, fatiga, inestabilidad hemodinámica, síncope o incluso el síndrome de Stokes-Adams. El ritmo de escape que se origina por encima de la bifurcación del haz de His produce intervalos QRS estrechos con frecuencia cardíaca no muy lenta (excepto en casos de enfermedad del sistema Hisiano). Presentamos a un hombre de mediana edad con una frecuencia cardíaca de 34 lpm, fatiga progresiva, en el que se implantó un marcapasos temporario en la región subtricuspídea. El electrocardiograma resultante a la intervención presentó características inusuales.


Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Estimulación Cardíaca Artificial/efectos adversos , Frecuencia Cardíaca/fisiología , Ventrículos Cardíacos/fisiopatología , Electrocardiografía , Fatiga/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología
2.
Arch Cardiol Mex ; 90(1): 16-20, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31996859

RESUMEN

Complete heart block (CHB) results from dysfunction of the cardiac conduction system, which results in complete electrical dissociation. The ventricular escape rhythm can have its origin anywhere from the atrioventricular node to the bundle branch-Purkinje system. CHB typically results in bradycardia, hypotension, fatigue, hemodynamic instability, syncope, or even Stokes-Adams syndrome. Escape rhythm originating above the bifurcation of the His bundle (HB) produces narrow QRSs with relatively rapid heart rate (HR) (except in cases of His system disease). We present a middle-aged man with an HR of 34 bpm, progressive fatigue, in whom a temporary pacemaker was implanted in the subtricuspid region. The post-intervention electrocardiogram had unusual features.


El bloqueo cardíaco completo (BCC) resulta de la disfunción del sistema de conducción cardíaco, lo que ocasiona una disociación eléctrica completa entre aurículas y ventrículos. El ritmo de escape resultante puede tener su origen en cualquier lugar desde el nodo auriculoventricular hasta el sistema His Purkinje. El BCC generalmente produce bradicardia, hipotensión, fatiga, inestabilidad hemodinámica, síncope o incluso el síndrome de Stokes-Adams. El ritmo de escape que se origina por encima de la bifurcación del haz de His produce intervalos QRS estrechos con frecuencia cardíaca no muy lenta (excepto en casos de enfermedad del sistema Hisiano). Presentamos a un hombre de mediana edad con una frecuencia cardíaca de 34 lpm, fatiga progresiva, en el que se implantó un marcapasos temporario en la región subtricuspídea. El electrocardiograma resultante a la intervención presentó características inusuales.


Asunto(s)
Estimulación Cardíaca Artificial/efectos adversos , Frecuencia Cardíaca/fisiología , Ventrículos Cardíacos/fisiopatología , Electrocardiografía , Fatiga/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad
3.
Rev. mex. cardiol ; 29(1): 50-54, Jan.-Mar. 2018. graf
Artículo en Inglés | LILACS | ID: biblio-1004301

RESUMEN

Abstract: One of the most common pathologies attributed to lupus neonatal refers to atrioventricular (AV) congenital block, which diagnosis can be made between 16 and 30 weeks of gestation due to persistent fetal bradycardia. The development of this disease is mostly related to maternal anti-Ro/SSA and anti-Smith autoantibodies. Currently, there are a number of alternatives for prenatal and postnatal treatment, with some controversy about their viability. The placement of a permanent pacemaker is presented as one of the most appropriate procedures currently, even with the risks awarded. This case report describes the placement of a permanent pacemaker to a two-month-old newborn with high maternal contents of anti-Ro/SSA and anti-Smith nuclear autoantibodies, with a favorable outcome.(AU)


Resumen: Una de las patologías más comunes atribuidas al lupus neonatal se refiere al bloqueo congénito atrioventricular (AV), diagnóstico que se puede realizar entre 16 y 30 semanas de gestación debido a bradicardia fetal persistente. El desarrollo de esta enfermedad se relaciona principalmente con los anticuerpos anti-Ro/SSA materno y anti-Smith. Actualmente, existen varias alternativas para el tratamiento prenatal y postnatal, con cierta controversia sobre su viabilidad. La colocación de un marcapasos permanente se presenta como uno de los procedimientos más adecuados actualmente, incluso con los riesgos adjudicados. Este relato de caso describe la colocación de un marcapasos permanente en un recién nacido de dos meses con alto contenido materno de autoanticuerpos anti-Ro/SSA y anti-Smith, con un resultado favorable.(AU)


Asunto(s)
Humanos , Lactante , Marcapaso Artificial , Nefritis Lúpica/congénito , Bradicardia/congénito , Bloqueo Cardíaco/congénito
4.
Rev. colomb. cardiol ; 24(5): 511-511, sep.-oct. 2017. graf
Artículo en Español | LILACS, COLNAL | ID: biblio-900572

RESUMEN

Resumen La afectación cardíaca en pacientes con sarcoidosis está siendo cada vez más reconocida y se asocia con mal pronóstico. Aunque en su patogénesis están implicados los factores ambientales y genéticos, la etiología de la sarcoidosis cardíaca no es clara. Las manifestaciones clínicas incluyen alteraciones de la conducción aurículo-ventricular, arritmias e insuficiencia cardíaca congestiva. Es una entidad extremadamente difícil de diagnosticar debido a que las manifestaciones clínicas son inespecíficas, y la sensibilidad y la especificidad de las modalidades de diagnóstico son limitadas. El tratamiento cardíaco óptimo no ha sido bien definido, y aunque los corticoides siguen siendo el pilar del manejo, hay poca evidencia de la dosis o la duración de la terapia. Se expone el caso de una paciente con sarcoidosis cardíaca aislada, que debutó con extrasístoles ventriculares y progresó a falla cardiaca y arritmias ventriculares sostenidas.


Abstract Cardiac involvement is increasingly being observed in patients with sarcoidosis and is associated with a poor prognosis. Although environmental and genetic factors play a part in its pathogenesis, the aetiology of cardiac sarcoidosis is still not clear. The clinical signs include anomalies in atrial-ventricular conduction, arrhythmias, and congestive cardiac failure. It is an extremely difficult condition to diagnose as the clinical signs are vague, and the sensitivity and specificity of the diagnostic models are limited. There is no well-defined optimum cardiac treatment, and although corticosteroids continue to be the mainstay of its management, there is little evidence on the dose or duration of the treatment. It is presented a case of a patient with isolated cardiac sarcoidosis that debuted with ventricular extrasystoles and progressed to cardiac failure and sustained ventricular arrhythmias.


Asunto(s)
Humanos , Miocarditis , Bloqueo de Rama , Bloqueo Cardíaco , Taquicardia
5.
Med. lab ; 23(11-12): 565-572, 2017.
Artículo en Español | LILACS, COLNAL | ID: biblio-1097346

RESUMEN

la afección cardiovascular es una presentación atípica del dengue, que abarca desde bradicardia sinusal asintomática hasta miocarditis grave, aunque no hay datos locales de esta presentación. Objetivo: describir las características clínicas de una serie de pacientes con dengue y evidencia de afección cardiovascular. Materiales y métodos: se realizó un estudio observacional, de corte trasversal, de pacientes admitidos con dengue a un centro de referencia cardiovascular en Medellín, Colombia, durante dos epidemias del virus entre junio de 2010 y diciembre de 2016. Se evaluaron variables clínicas y paraclínicas. Resultados: se registraron un total de 60 pacientes, de los cuales el 30% (18/60) tuvieron compromiso cardiovascular y fueron incluidos en este estudio. La edad media de estos pacientes fue de 63 años y el 56% (10/18) eran hombres. La comorbilidad más frecuente fue la hipertensión arterial esencial (61%, 11/18). La alteración del ritmo cardíaco afectó al 72% (13/18) de los pacientes, con presencia de bloqueo auriculoventricular de primer grado (46%), bradicardia sinusal (38%), fibrilación/aleteo/taquicardia atriales (23%) y ritmo de la unión (8%). La miocarditis y la pericarditis se presentaron en el 17% (3/18) y 11% (2/18) de los pacientes, respectivamente. Otros hallazgos menos comunes fueron la disfunción ventricular izquierda y la angina de pecho (11%, 2/18). No hubo muertes durante la realización del estudio. Conclusiones: las alteraciones asintomáticas del ritmo cardiaco fueron las manifestaciones cardiovasculares más frecuentes del dengue y las afecciones cardiovasculares graves fueron infrecuentes. Se recomienda atención a los síntomas leves de disfunción cardiovascular en los pacientes con dengue


cardiovascular involvement is an atypical presentation of dengue infection. There range from asymptomatic sinus bradycardia to severe life-threatening myocarditis. Data are lacking regarding epidemiology on this topic. Objective: To describe clinical characteristics of patient's series with dengue and evidence of cardiovascular involvement. Materials and methods: It was performed a cross-section, observational study of patients admitted with dengue fever in a cardiovascular reference center in Medellín, Colombia during two epidemic viral outbreaks from June 2010 to December 2016. Results: A total of 60 patients were registred, 30% of them with evidence of cardiovascular involvement. Mean age of patients was 63 years old and 55% were male. Most common comorbidity was hypertension (61%, 11/18). Rhythm disturbances affected 72% (13/18) of patients: first grade AV block (46%), sinus bradycardia (38%), atrial fibrillation/flutter/tachycardia (23%) and junctional rhythm (8%). Myocarditis and pericarditis were present in 17% (3/18) and 11% (2/18) of patients, respectively. Other less common findings were left ventricular dysfunction and angor pectoris (11%, 2/18). There were no deaths during the study period. Conclusions: Asymptomatic rhythm disturbances were the most common cardiovascular manifestations of dengue fever and severe forms of cardiovascular dengue were rare. It is recommended to be attentive to the mild symptoms of cardiovascular dysfunction in patients with dengue


Asunto(s)
Humanos , Dengue , Oxigenación por Membrana Extracorpórea , Anomalías Cardiovasculares , Bloqueo Cardíaco , Miocarditis
6.
Rev. colomb. cardiol ; 23(5): 453-453, sep.-oct. 2016. graf
Artículo en Español | LILACS, COLNAL | ID: biblio-959909

RESUMEN

Resumen La disfunción ventricular izquierda y la cardiopatía dilatada (CD), debidas a la estimulación crónica ventricular derecha son complicaciones reconocidas en adultos y niños. La terapia de la resincronización cardiaca (TRC), ha demostrado beneficios en los adultos con disfunción ventricular izquierda (FEVI < 35%), deterioro de la clase funcional y bloqueo de la rama izquierda (intrínseco o inducido por estimulación). En los niños la incidencia de cardiomiopatía dilatada es desconocida y no existen guías o grandes estudios sobre la resincronización cardiaca, por lo que no es posible extrapolar las recomendaciones de los pacientes adultos. Se presenta la experiencia en una paciente con bloqueo A-V completo postquirúrgico tras corrección de cardiopatía congénita, portadora de un marcapaso quien desarrolló la falla cardiaca, esta fue tratada exitosamente mediante la resincronización biventricular en dos oportunidades, con recuperación de la clase funcional y los parámetros hemodinámicos.


Abstract Left ventricular dysfunction and dilated cardiomyopathy (DC) caused by right ventricular chronic stimulation are recognised complications in adults and children. Cardiac resynchronization therapy (CRT) has shown benefits in adults with left ventricular dysfunction (LVEF < 35%), deterioration of functional class and left bundle-branch block (instrinsic or induced by stimulation). Incidence of dilated cardiomyopathy in children is unknown, and there are no guides or big studies about cardiac resynchronization therapy, so recommendations for adult patients cannot be extrapolated. The experience of a female patient with a pacemaker and postoperative complete AV block after correction of a congenital heart disease is presented; she developed heart failure that was successfully treated with biventricular resynchronization in two opportunities, with recovery of functional class and hemodynamic parametres.


Asunto(s)
Humanos , Femenino , Lactante , Bloqueo Cardíaco , Cardiopatías Congénitas , Relojes Biológicos , Insuficiencia Cardíaca
7.
Rev. colomb. cardiol ; 23(2): 152.e1-152.e3, mar.-abr, 2016. tab
Artículo en Español | LILACS, COLNAL | ID: lil-791266

RESUMEN

El uso de la radioterapia ha contribuido a mejorar la supervivencia de pacientes con diversos tumores malignos relacionados con la región torácica. No obstante, la irradiación cardíaca a una dosis suficientemente alta puede dañar prácticamente cualquier componente del mismo, incluyendo el sistema de conducción. Se describe el caso de un paciente que desarrolló bloqueo auriculoventricular completo, más de veinte años después de recibir radioterapia supradiafragmática para el tratamiento de un linfoma de Hodgkin.


The use of radiotherapy has contributed to improving the survival in patients with diverse malignancies related to the thoracic region. Nevertheless, cardiac radiation in sufficiently high dose can damage virtually any of its components, including the conduction system. We describe the case of a patient who developed a complete atrioventricular block more than twenty years after receiving supradiaphragmatic radiotherapy for Hodgkin lymphoma.


Asunto(s)
Humanos , Masculino , Adulto , Bloqueo Cardíaco , Nodo Atrioventricular , Relojes Biológicos , Neoplasias
8.
Rev. colomb. cardiol ; 23(2): 150.e1-150.e5, mar.-abr, 2016. ilus
Artículo en Español | LILACS, COLNAL | ID: lil-791264

RESUMEN

La amiloidosis cardiaca es una manifestación de un grupo de enfermedades sistémicas que se caracteriza por el mal plegamiento de proteínas que causa un depósito extracelular de la amiloide, conocido como amiloidosis. Es una causa importante de las enfermedades infiltrativas, que pueden ser responsables tanto del compromiso cardiaco como de otros órganos. Es importante el reconocimiento de su etiología primaria o secundaria para dar el tratamiento adecuado según su causa. Describimos un caso de un paciente de 69 años de edad, con amiloidosis que ingresa al servicio de urgencias con un bloqueo auriculoventricular completo.


Cardiac amyloidosis is a manifestation of a systemic diseases group characterized by protein misfolding caused by extracellular deposition of amyloid, known as amyloidosis. It is the main cause of infiltrative diseases that can be responsible of cardiac involvement as to other organs. It is important to recognize its primary or secondary etiology to give the appropriate treatment depending of the cause. We describe a case of a 69 year old patient with cardiac amyloidosis debuting in the emergency room with complete atrioventricular block.


Asunto(s)
Humanos , Amiloidosis , Bloqueo Cardíaco
9.
Rev. urug. cardiol ; 30(3): 404-410, dic. 2015. ilus
Artículo en Español | LILACS-Express | LILACS | ID: lil-774669

RESUMEN

El síndrome de Bayés refiere a la asociación entre el bloqueo interauricular avanzado y la fibrilación auricular (FA). Este simple parámetro electrocardiográfico, sencillo de aprender, es útil para identificar pacientes con alto riesgo de presentar una nueva FA o recurrencias luego de instaurado el tratamiento antiarrítmico (fármacos, cardioversión o ablación). Una vez detectado el patrón clásico del trastorno de la conducción interauricular, debe realizarse una pesquisa meticulosa en busca de FA. El síndrome de Bayés es un epónimo en reconocimiento al genial catalán que ha descrito la fisiopatología, las manifestaciones clínico-electrocardiográficas, la asociación con arritmias supraventriculares y los posibles tratamientos.

10.
Rev. colomb. cardiol ; 20(6): 366-369, nov.-dic. 2013.
Artículo en Español | LILACS, COLNAL | ID: lil-706582

RESUMEN

INTRODUCCIÓN: el dengue es la enfermedad viral transmitida por vectores de diseminación más frecuente en el mundo. Su espectro clínico incluye las manifestaciones atípicas, entre ellas el compromiso cardiaco, del cual sólo se han reportado pocas series de casos en la literatura. OBJETIVO: reportar las características clínicas de los pacientes atendidos por casos confirmados por serología de dengue con manifestaciones cardiovasculares en un centro de referencia cardiovascular colombiano durante la epidemia de 2010. METODOLOGÍA: estudio observacional, descriptivo, prospectivo, en el que se incluyeron los pacientes que consultaron al servicio de urgencias, a quienes se les realizó un diagnóstico confirmado de dengue y tuvieron manifestaciones cardiovasculares de la enfermedad. RESULTADOS: se encontraron 7 pacientes; el 50% no tenía antecedentes previos de enfermedad cardiovascular. Los trastornos del ritmo fueron la manifestación cardiaca más frecuente (42,8%), entre ellos la fibrilación auricular de novo (14,2%), el bloqueo auriculoventricular completo y transitorio (14,2%), la bradicardia sinusal concomitante con derrame pericárdico (14,2%) y la disfunción ventricular leve (28,5%); un paciente presentó un síndrome coronario agudo con elevación de ST durante la infección y dos descompensación aguda de insuficiencia cardiaca. No se reportaron muertes. CONCLUSIÓN: la incidencia de las complicaciones cardiacas asociadas a la infección por dengue varía de una serie a otra y su fisiopatología no se conoce por completo. Durante la epidemia que se desató en Colombia en 2010 se encontraron pocos casos de manifestaciones cardiovasculares pero con una morbilidad importante que debe alertar respecto a su identificación temprana.


INTRODUCTION: dengue is the most common worldwide viral disease transmitted by dissemination vectors. Its clinical spectrum comprehends atypical manifestations including cardiac involvement, from which only few series of cases have been reported in the literature. OBJECTIVE: to report the clinical characteristics of patients treated for serologically confirmed cases of dengue with cardiovascular events in a Colombian cardiovascular referral center during the epidemic of 2010. METHODS: an observational, descriptive, prospective study, which included patients presenting to the emergency service and had a confirmed diagnosis of dengue with cardiovascular manifestations of the disease. RESULTS: 7 patients met the inclusion criteria. 50% had no prior history of cardiovascular disease. Rhythm disorders were the most common cardiac manifestation (42.8%), including de novo atrial fibrillation (14.2%), complete atrioventricular block and transient (14.2%), sinus bradycardia concomitant with pericardial effusion (14.2%) and mild ventricular dysfunction (28.5%). One patient had an acute coronary syndrome with ST elevation during infection and two had acute decompensated heart failure. No deaths were reported. CONCLUSION: the incidence of cardiac complications associated with dengue infection varies from one series to another and its pathophysiology is not completely understood. During the epidemic that occurred in Colombia in 2010 there were few cases with cardiovascular symptoms but with significant morbidity that should alert regarding its early identification.


Asunto(s)
Dengue , Insuficiencia Cardíaca , Epidemiología , Epidemias , Bloqueo Cardíaco
11.
Rev. colomb. anestesiol ; 41(4): 298-301, oct.-dic. 2013.
Artículo en Español | LILACS, COLNAL | ID: lil-698797

RESUMEN

Objetivo:Realizar una revisión de la literatura del bloqueo cardiaco auriculoventricular completo o de tercer grado en colecistectomía laparoscópica, describir su incidencia, su etiología y actualizar su manejo. Material y métodos:Se presenta el caso de un paciente con paro cardiaco secundario a un bloqueo cardiaco completo de complejo ancho durante una colecistectomía laparoscópica, su manejo y desenlace. La búsqueda bibliográfica se realizó en Pub Med, Scielo y Bireme. Resultados: El bloqueo cardiaco auriculoventricular completo o grado III paroxístico es una entidad poco frecuente y que puede ser desencadenada por estímulos vagales quirúrgicos (estrés quirúrgico, neumoperitoneo) y no quirúrgicos (masaje carotídeo, tos, ejercicio, vómito y deglución) además de los debidos a isquemia miocárdica y anomalías de conducción cardiaca. Este el primer caso en nuestra institución, existiendo en la literatura médica mundial pocos casos descritos y ninguno a nivel nacional. Condusiones:Se requiere un mayor conocimiento y experiencia del anestesiólogo en relación al diagnóstico y manejo del bloqueo cardiaco completo en colecistectomía laparoscópica, que constituye la cirugía laparoscópica más frecuente mundialmente. La utilización de anestesia peridural asociada a anestesia general para procedimientos quirúrgicos abdominales altos y torácicos disminuye en 5 veces la aparición de arritmias cardiacas postoperatorias. En los pacientes ASA 3 y 4 con comorbilidad cardiovascular se recomiendan 3 puntos de cuidado: considerar monitorización invasiva de la presión arterial, cabecera a 10 grados y limitar la presión de neumoperitoneo a 7 mmHg.


Objective: To undertake a literature reviewon third-degree complete atrioventricularblock in laparoscopic cholecystectomy, describing its incidence, etiology and management update. Materials and methods: This is a case discussion of a patient with cardiac arrest following complete wide-complex heart block during a laparoscopic cholecystectomy, its manage-ment, and outcomes. The literature search included PubMed, Scielo and Bireme. Results:Complete or third degree paroxysmal AV block is a rare occurrence that may be triggered by surgical vagal stimuli (surgical stress, pneumoperitoneum) and by non-surgical stimuli (carotid massage, coughing, exercise, vomiting and swallowing), in addition to sti-muli frommyocardial ischemia and cardiac conduction anomalies. This is the first case in our institution but there are very few cases described in the world literature and none at the national level. Conclusions:Enhanced knowledge and experience of the anesthesiologist is required for the diagnosis and management of complete heart block in laparoscopic cholecystectomy, which is the most frequent laparoscopic surgical procedure worldwide. The use of epidural anesthesia associated with general anesthesia for upper abdominal and chest surgery reduces by five fold the occurrence of postoperative cardiac arrhythmia. Three safety measures are recommended for ASA 3 and 4 patients with cardiovascular comorbidity: consider invasive blood pressure monitoring, head at 10 and limit the pneumoperitoneal pressure to 7 mmHg.


Asunto(s)
Humanos
12.
Rev Electron ; 36(4)oct.-dic. 2011.
Artículo en Español | CUMED | ID: cum-47780

RESUMEN

Se presenta un recién nacido con bloqueo aurículo ventricular congénito, diagnosticado en el Hospital General Docente Dr Ernesto Guevara de la Serna. Su madre tenía antecedentes de artritis reumatoidea. Por mantenerse con frecuencias cardiacas bajas, con QRS ancho y arritmias ventriculares, se implantó marcapaso permanente. Se revisó la bibliografía (AU)


A newborn with a congenital atrioventricular block was diagnosed at Dr Ernesto Guevara de la Serna General Teaching Hospital. His family history showed that his mother suffered of rheumatoid arthritis. As the patient kept low heart rates, wide QRS and ventricular arrhythmia, a permanent pacemaker was implanted. The bibliography was also checked (AU)


Asunto(s)
Humanos , Bloqueo Atrioventricular , Bloqueo Cardíaco , Marcapaso Artificial
13.
Rev. colomb. cardiol ; 18(5): 279-281, sept.-oct. 2011.
Artículo en Español | LILACS | ID: lil-647251

RESUMEN

Se presenta el caso de una familia con bloqueo aurículo-ventricular, que compromete varias generaciones, con herencia mendeliana autosómica dominante, que afecta de manera progresiva el sistema de conducción cardiaco llevando a síncope y muerte súbita en edades tempranas. Esta entidad corresponde al bloqueo familiar cardiaco progresivo tipo I, descrito principalmente en Suráfrica. El tratamiento con marcapaso definitivo fue exitoso.


We present the case of a family with atrio-ventricular block that involves several generations, with dominant autosomal mendelian inheritance that progressively affects the cardiac conduction system leading to syncope and sudden death in early life. This entity corresponds to progressive familial atrio-ventricular block type I, described mainly in South Africa. Treatment with permanent pacemaker therapy was successful.


Asunto(s)
Muerte Súbita , Genética , Bloqueo Cardíaco
14.
VozAndes ; 21(1): 27-28, 2010.
Artículo en Español | LILACS | ID: biblio-1025517

RESUMEN

Reportamos el caso de una paciente con bloqueo aurículoventricular completo, con un marcapaso epicárdico infectado y venas torácicas inabordables, en quien se realizó exitosamente el implante transfemoral de un marcapaso unicameral VVIR. Revisamos la literatura con algunas series en las que se demuestra la factibilidad y seguridad de la técnica.


We report the case of a patient with complete atrioventricular block, with an infected epicardial pacemaker and intractable thoracic veins, in which it was performed successfully the transfemoral implant of a unicameral pacemaker VVIR. We check literature with some series in which the feasibility and safety of The technique.


Asunto(s)
Humanos , Marcapaso Artificial , Vena Femoral , Bloqueo Cardíaco , Bloqueo Atrioventricular , Contraindicaciones
15.
Rev. colomb. cardiol ; 16(4): 178-181, jul.-ago. 2009.
Artículo en Español | LILACS | ID: lil-534579

RESUMEN

La miocarditis de células gigantes es una enfermedad grave y poco frecuente, cuya etiología, posiblemente autoinmune, se caracteriza por la presencia de células gigantes multinucleadas con infiltrado inflamatorio y necrosis extensa en la biopsia endomiocárdica. Es común su asociación con taquicardias ventriculares y con alteraciones de la conducción aurículo-ventricular, lo cual se resuelve algunas veces con tratamiento inmunosupresor. Dada la complejidad del pronóstico de esta entidad, el papel de los dispositivos de resincronización después de la estabilización de la falla cardíaca, no está claro. Aquí se reporta un caso en el cual el implante de uno de estos dispositivos fue parte fundamental de la terapia y recuperación del paciente.


Giant cell myocarditis is an infrequent and serious illness, possibly of autoimmune etiology, characterized by the presence of multinucleated giant cells with inflammatory infiltrate and extensive necrosis in the endomyocardial biopsy. Its association with ventricular tachycardia is common and alterations in atrioventricular conduction are frequently solved through immunosuppressive treatment. Given the generally complex prognosis of this entity, the role of the resynchronization devices after the heart failure stabilization, is unclear. We reported a case in which the implant of one of these devices was a fundamental part of the therapy and patient recovery.


Asunto(s)
Bloqueo Cardíaco , Insuficiencia Cardíaca , Miocarditis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA