Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 187
Filtrar
1.
Ultrasound J ; 16(1): 42, 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-39283362

RESUMEN

BACKGROUND: Ultrasound can detect fluid in the alveolar and interstitial spaces of the lung using the presence of artifacts known as B-lines. The aim of this study was to determine whether a deep learning algorithm generated B-line severity score correlated with pulmonary congestion and disease severity based on clinical assessment (as identified by composite congestion score and Rothman index) and to evaluate changes in the score with treatment. Patients suspected of congestive heart failure underwent daily ultrasonography. Eight lung zones (right and left anterior/lateral and superior/inferior) were scanned using a tablet ultrasound system with a phased-array probe. Mixed effects modeling explored the association between average B-line score and the composite congestion score, and average B-line score and Rothman index, respectively. Covariates tested included patient and exam level data (sex, age, presence of selected comorbidities, baseline sodium and hemoglobin, creatinine, vital signs, oxygen delivery amount and delivery method, diuretic dose). RESULTS: Analysis included 110 unique subjects (3379 clips). B-line severity score was significantly associated with the composite congestion score, with a coefficient of 0.7 (95% CI 0.1-1.2 p = 0.02), but was not significantly associated with the Rothman index. CONCLUSIONS: Use of this technology may allow clinicians with limited ultrasound experience to determine an objective measure of B-line burden.

2.
Wilderness Environ Med ; : 10806032241281463, 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-39279453

RESUMEN

INTRODUCTION: B-lines on lung ultrasound have been found in asymptomatic competitive breath-hold divers, but their significance and time to resolution are not well understood. We sought to investigate the relationship between B-lines, oxygen saturation, and respiratory symptoms after competitive dives to diagnose pulmonary injury. METHODS: We performed lung ultrasounds before (predive), immediately after (postdive), and within 1 h (follow-up) of a competitive dive. B-lines were counted in each intercostal space in the anterior, lateral, and posterior lung fields, and the highest number of B-lines within a space was recorded for each lung region. At follow-up, each diver's oxygen saturation and respiratory symptoms were recorded. Statistical analysis included the Kruskal-Wallis test, Spearman's correlation, and sensitivity and specificity calculations. RESULTS: Forty-four divers completed 143 individual dives of four different disciplines. The median number of B-lines was 0 (IQR inclusive=0) predive, 1 (IQR=3) postdive, and 0 (IQR=1) at follow-up. There was a significant difference in total B-lines between measurement times (p<0.001). Sensitivity and specificity of hypoxemia, clinically significant B-lines, and both measures in tandem in detecting respiratory symptomatology were 52% and 76%, 24% and 92%, and 24% and 95%, respectively. CONCLUSIONS: B-lines are a common phenomenon in competitive breath-hold divers on surfacing and decrease within 1 h, suggesting a physiologic fluid shift. B-lines are negatively correlated with oxygen saturation, indicating that extravascular fluid impairs gas exchange in the lung. Neither hypoxemia nor clinically significant B-lines were found to be reliable indicators for respiratory symptomatology, suggesting that there may be multiple phenotypes of freediving-induced pulmonary syndrome.

3.
Echo Res Pract ; 11(1): 21, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39129021

RESUMEN

BACKGROUND: The development of heart failure is a turning point in the natural course of aortic stenosis (AS). Pulmonary oedema and elevated left ventricular pressure (LVP) are cardinal features of heart failure. Evaluating pulmonary oedema by lung ultrasound involves taking the upper hand with a bedside noninvasive tool that may reflect LVP. AIM: We sought to assess the correlation between sonographic pulmonary congestion, invasive LV pre-A pressure, and echocardiographic LV end-diastolic pressure (LVEDP) in symptomatic AS patients receiving transcatheter aortic valve replacement. METHODS: Forty-eight consecutive patients with severe AS and planned transcatheter aortic valve implantation (TAVI) were enrolled. LVEDP was estimated to be normal or elevated using the ASE/EACVI algorithm and transmitral Doppler indices, the E/A ratio, the E/e', and the left atrial volume index. Invasive LV pre-A pressure was used as a reference, with > 12 mm Hg defined as elevated. RESULTS: Forty-eight patients (25 women (52%), mean age 75 years, standard deviation (SD) ± 7.7 years) were enrolled in the study. We detected severe B-lines (≥ 30) in 13 (27%) patients and moderate B-lines (15-30) in 33 (68.6%) patients. The number of B-lines increased significantly with the severity of New York Heart Association (NYHA) functional classes (Fig. 1). The B-line count was 14 ± 13 in NYHA class I patients, 20 ± 20 in class II patients, and 44 ± 35 in class III patients (p < 0.05, rho = 0.384). The number of B-lines was correlated with the E/E' ratio (R = 0.664, p < 0.0001) and the proBNP level (R = 0. 882, p < 0.008). We found no significant correlation with the LVEDP or LVEF. The LVEDP correlated well with the E/E' ratio (R = 0.491, p < 0.001) but not at all with E/A, DT, or LAVI. All patients had an elevated LVEDP > 12, with a mean pressure of 26 mmHg, a minimum of 13 mmHg, and a maximum of 45 mmHg, with an SD of 7.85. CONCLUSION: Assessing lung ultrasonic B-lines is a straightforward and practical approach to identifying pulmonary oedema in AS patients. The number of B-lines correlated with the E/E' ratio and the functional status of patients but did not correlate with invasive LVEDP or LVEF. All patients had elevated LVEDP that correlated with E/E'.

4.
J Pers Med ; 14(7)2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39064020

RESUMEN

Assessing for volume overload is a key component of both short and long-term management of heart failure patients. Physical examination findings are neither sensitive nor specific for detecting congestion, and subclinical congestion may not be evident at the time of examination. Point of care ultrasound (POCUS) is an efficient and non-invasive way to assess heart failure patients for volume overload. The aim of our narrative review is to summarize how each of the following ultrasound modalities can be used to assess for congestion in the heart failure population: 2D and Doppler echocardiography, lung ultrasound, inferior vena cava ultrasound, internal jugular vein ultrasound, and venous excess grading. While each of these modalities has their limitations, their use in the acute and outpatient space offers the potential to reduce heart failure readmissions and mortality.

5.
Diagnostics (Basel) ; 14(13)2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-39001320

RESUMEN

Lung involvement represents a fearful complication in rheumatoid arthritis (RA), potentially involving all compartments of the pulmonary system. Regarding interstitial lung disease (ILD), the HRCT represents the gold standard technique for its diagnosis; however, the examination is burdened by radiation exposure and high costs. In addition, although some risk factors for ILD are known, no algorithms exist to know which patients to submit to HRCT and when. In this context, lung ultrasound (LUS) showed promising results for at least 10 years, demonstrating correlation with high resolution computed tomography (HRCT) findings in other rheumatic diseases. Here, LUS may represent a screening test providing additional information to clinical examination and pulmonary function tests. The data deriving from LUS experience in other rheumatic diseases could steer the future towards the use of this technique also in RA patients, and in this review, we report the most relevant literature regarding LUS in RA-ILD.

6.
Hemodial Int ; 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38965069

RESUMEN

INTRODUCTION: Optimization of ultrafiltration during hemodialysis is a critical parameter in achieving therapeutic efficacy and ensuring hemodynamic stability. While various modalities such as blood volume monitoring, inferior vena cava diameter assessment, natriuretic peptide levels, bioimpedance assay, and lung ultrasound have been widely explored in the context of maintenance hemodialysis, the concept of volume-guided ultrafiltration in dialysis patients with acute kidney injury remains unexplored. METHODS: Adult patients with acute kidney injury requiring dialysis, who were hemodynamically stable and not on ventilator support, without underlying lung pathology or cardiac failure, were randomized into two groups. All patients underwent 28-zone lung ultrasound before dialysis. The ultrafiltration was decided based on the treating physician's clinical judgment in controls. In the intervention group, the ultrafiltration orders prescribed by the treating physician were modified, based on the Kerley B line scores obtained by lung ultrasound. The rest of the dialysis prescriptions were similar. A postdialysis lung ultrasound was done in both groups to assess the postdialysis volume status 30 min after the dialysis session. RESULTS: A total of 74 patients undergoing hemodialysis for acute kidney injury were randomized. The baseline characteristics were comparable except for higher baseline B line score scores in the intervention arm. All patients received similar dialysis prescriptions. The lung ultrasound-guided ultrafiltration arm had a higher change in B line scores (BLS) from baseline (4 [0-9.5] vs. 0 [0-4]; p value 0.004) during the first dialysis session. The predialysis BLS indexed to ultrafiltration (mL/kbw/h) were significantly lower in controls, reflecting a relatively higher rate of ultrafiltration in controls compared with intervention (p = 0.006). The total number of dialysis sessions done in the control and intervention arm were 61 and 59, respectively. Among controls, 23/61 sessions (37.7%) had intradialytic adverse events, whereas, in the intervention arm, only 4/59 sessions (6.7) had any adverse intradialytic events (p < 0.01). CONCLUSION: Lung ultrasound-guided ultrafiltration was associated with a better safety profile, as demonstrated by reduced intradialytic events.

8.
J Med Internet Res ; 26: e51397, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38963923

RESUMEN

BACKGROUND: Machine learning (ML) models can yield faster and more accurate medical diagnoses; however, developing ML models is limited by a lack of high-quality labeled training data. Crowdsourced labeling is a potential solution but can be constrained by concerns about label quality. OBJECTIVE: This study aims to examine whether a gamified crowdsourcing platform with continuous performance assessment, user feedback, and performance-based incentives could produce expert-quality labels on medical imaging data. METHODS: In this diagnostic comparison study, 2384 lung ultrasound clips were retrospectively collected from 203 emergency department patients. A total of 6 lung ultrasound experts classified 393 of these clips as having no B-lines, one or more discrete B-lines, or confluent B-lines to create 2 sets of reference standard data sets (195 training clips and 198 test clips). Sets were respectively used to (1) train users on a gamified crowdsourcing platform and (2) compare the concordance of the resulting crowd labels to the concordance of individual experts to reference standards. Crowd opinions were sourced from DiagnosUs (Centaur Labs) iOS app users over 8 days, filtered based on past performance, aggregated using majority rule, and analyzed for label concordance compared with a hold-out test set of expert-labeled clips. The primary outcome was comparing the labeling concordance of collated crowd opinions to trained experts in classifying B-lines on lung ultrasound clips. RESULTS: Our clinical data set included patients with a mean age of 60.0 (SD 19.0) years; 105 (51.7%) patients were female and 114 (56.1%) patients were White. Over the 195 training clips, the expert-consensus label distribution was 114 (58%) no B-lines, 56 (29%) discrete B-lines, and 25 (13%) confluent B-lines. Over the 198 test clips, expert-consensus label distribution was 138 (70%) no B-lines, 36 (18%) discrete B-lines, and 24 (12%) confluent B-lines. In total, 99,238 opinions were collected from 426 unique users. On a test set of 198 clips, the mean labeling concordance of individual experts relative to the reference standard was 85.0% (SE 2.0), compared with 87.9% crowdsourced label concordance (P=.15). When individual experts' opinions were compared with reference standard labels created by majority vote excluding their own opinion, crowd concordance was higher than the mean concordance of individual experts to reference standards (87.4% vs 80.8%, SE 1.6 for expert concordance; P<.001). Clips with discrete B-lines had the most disagreement from both the crowd consensus and individual experts with the expert consensus. Using randomly sampled subsets of crowd opinions, 7 quality-filtered opinions were sufficient to achieve near the maximum crowd concordance. CONCLUSIONS: Crowdsourced labels for B-line classification on lung ultrasound clips via a gamified approach achieved expert-level accuracy. This suggests a strategic role for gamified crowdsourcing in efficiently generating labeled image data sets for training ML systems.


Asunto(s)
Colaboración de las Masas , Pulmón , Ultrasonografía , Colaboración de las Masas/métodos , Humanos , Ultrasonografía/métodos , Ultrasonografía/normas , Pulmón/diagnóstico por imagen , Estudios Prospectivos , Femenino , Masculino , Aprendizaje Automático , Adulto , Persona de Mediana Edad , Estudios Retrospectivos
9.
Eur Heart J Acute Cardiovasc Care ; 13(7): 566-569, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-38832853

RESUMEN

AIMS: The Killip scale remains a fundamental tool for prognostic assessment in ST-segment elevation myocardial infarction (STEMI) due to its simplicity and predictive value. Lung ultrasound (LUS) has emerged as a valuable adjunct for diagnosing and predicting outcomes in heart failure (HF) and STEMI patients, even those with subclinical congestion. We created a new classification (Killip pLUS), which reclassifies Killip I and II patients into an intermediate category (Killip I pLUS) based on LUS results. This category included Killip I patients and ≥1 positive zone (≥3 B-lines) and Killip II with 0 positive zones. We aimed to evaluate this new classification by comparing it with the Killip scale and a previous LUS-based reclassification scale (LUCK scale). METHODS AND RESULTS: Lung ultrasound was performed within 24 h of admission in a multicentre cohort of 373 patients admitted for STEMI. In-hospital mortality and major adverse cardiovascular events within one year after admission, comprising mortality or readmission for HF, acute coronary syndrome, or stroke, were analysed. When predicting in-hospital mortality, the global comparison of these three classifications was statistically significant: Killip pLUS area under the curve (AUC) 0.90 (95% CI 0.85-0.95) vs. Killip AUC 0.85 (95% CI 0.73-0.96) vs. LUCK 0.83 (95% CI 0.70-0.95), P = 0.024. To predict events during follow-up, the comparison between scales was also significant: Killip pLUS 0.77 (95% CI 0.71-0.85) vs. Killip 0.72 (95% CI 0.65-0.79) vs. LUCK 0.73 (95% CI 0.66-0.81), P = 0.033. CONCLUSION: The Killip pLUS scale provides enhanced risk stratification compared to the Killip and LUCK scales while preserving simplicity.


Asunto(s)
Pulmón , Infarto del Miocardio con Elevación del ST , Ultrasonografía , Humanos , Masculino , Femenino , Pulmón/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/diagnóstico , Anciano , Ultrasonografía/métodos , Pronóstico , Persona de Mediana Edad , Mortalidad Hospitalaria/tendencias , Medición de Riesgo/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/clasificación , Insuficiencia Cardíaca/diagnóstico , Valor Predictivo de las Pruebas
10.
Cureus ; 16(6): e63051, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38915837

RESUMEN

Purpose The number of B-lines on lung ultrasound at hospital discharge in patients admitted with acute heart failure (AHF) is associated with poor outcomes. Assessing B-lines can be challenging to execute and replicate, depending on the clinical context. This study aims to determine whether the lung ultrasound score (LUS) at discharge predicts hospital readmission or emergency department (ED) visits in the 30 days after an AHF hospital admission. Methods  We conducted an observational study at the medical ward of the emergency unit of the Clinics Hospital of the Ribeirao Preto Medical School, University of Sao Paulo, a tertiary university hospital in Ribeirao Preto, Sao Paulo, Brazil, where consecutive adults admitted with AHF were included. On the day of hospital discharge, we measured the LUS and tracked these patients for up to 30 days to monitor emergency department visits, hospital readmission, and the number of days free from hospital stay. Results  A total of 46 patients were included in the study. A composite outcome of ED visits or hospital readmission in the 30 days after hospital discharge was achieved for 22 (47.8%) patients. The LUS at hospital discharge had a receiver operating characteristic (ROC) area of 0.93 (95% CI, 0.82-0.99) to predict the composite outcome, against 0.67 (95% CI, 0.52-0.81) for the clinical congestion score (CCS). A LUS ≥ 7 at discharge had a sensitivity of 95.5% and a specificity of 87.5% to predict the composite outcome. The average exam duration was 176±65 (sd) seconds. Conclusions The LUS at hospital discharge following admission for AHF proves to be an accurate tool for predicting the likelihood of return to the ED and/or hospital readmission within 30 days post discharge.

11.
J Clin Med ; 13(11)2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38892735

RESUMEN

Background: Shiga toxin-producing Escherichia coli-haemolytic uremic syndrome (STEC-HUS) can result in kidney and neurological complications. Early volume-expansion therapy has been shown to improve outcomes, but caution is required to avoid fluid overload. Lung ultrasound scanning (LUS) can be used to detect fluid overload and may be useful in monitoring hydration therapy. Methods: This prospective observational pilot study involved children with STEC-HUS who were recruited from a regional paediatric nephrology centre. B-line quantification by LUS was used to assess fluid status at the emergency department (ED) admission and correlated with the decrease in patient weight from the target weight. A control group of children on chronic dialysis therapy with episodes of symptomatic fluid overload was also enrolled in order to establish a B-line threshold indicative of severe lung congestion. Another cohort of "healthy" children, without renal or lung-related diseases, and without clinical signs of fluid overload was also enrolled in order to establish a B-line threshold indicative of euvolemia. Results: LUS assessment was performed in 10 children with STEC-HUS at ED admission, showing an average of three B-lines (range 0-10). LUS was also performed in 53 euvolemic children admitted to the ED not showing kidney and lung disease (healthy controls), showing a median value of two B-lines (range 0-7), not significantly different from children with STEC-HUS at admission (p = 0.92). Children with STEC-HUS with neurological involvement during the acute phase and those requiring dialysis presented a significantly lower number of B-lines at admission compared to patients with a good clinical course (p < 0.001). Patients with long-term renal impairment also presented a lower number of B-lines at disease onset (p = 0.03). Conclusions: LUS is a useful technique for monitoring intravenous hydration therapy in paediatric patients with STEC-HUS. A low number of B-lines at ED admission (<5 B-lines) was associated with worse short-term and long-term outcomes. Further studies are needed to determine the efficacy and safety of an LUS-guided strategy for reducing complications in children with STEC-HUS.

12.
Clin Rheumatol ; 43(6): 2117-2123, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38700662

RESUMEN

OBJECTIVE: To explore the diagnostic value of lung ultrasound (LUS) and pleural shear wave elastography (SWE) for connective tissue disease-interstitial lung disease (CTD-ILD). METHODS: We selected 104 patients diagnosed with connective tissue disease (CTD) at our hospital. All patients underwent LUS, SWE, and high-resolution computed tomography (HRCT). With HRCT as the imaging gold standard for diagnosis, patients were categorized into CTD-ILD and CTD-non-ILD groups. We employed paired chi-square tests to compare the diagnostic differences between HRCT and LUS for ILD. Receiver operating characteristic (ROC) curves were used to assess the diagnostic value of pleural SWE for ILD. Correlation analysis was performed between pleural elasticity values and lung ultrasound scores. RESULTS: The sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of LUS for diagnosing CTD-ILD were 93.3%, 86.2%, 6.761, and 0.078, respectively. There was no statistically significant difference in the results between HRCT and LUS (P = 1.000), with a kappa value of 0.720 (P < 0.001). There was a statistically significant difference in the pleural elasticity in the bilateral lower back region between the case and control groups (P < 0.001). The area under the receiver operating characteristic (ROC) curve (AUC) for pleural SWE in diagnosing CTD-ILD was 0.685. In CTD-ILD patients, there was no significant correlation between pleural elasticity values and LUS scores (P > 0.05). CONCLUSION: The LUS can serve as an important imaging method for screening for CTD-ILD and assessing the severity of the disease. However, pleural SWE has been shown to demonstrate lower diagnostic efficacy for CTD-ILD, and its ability to assess disease severity is limited.


Asunto(s)
Enfermedades del Tejido Conjuntivo , Diagnóstico por Imagen de Elasticidad , Enfermedades Pulmonares Intersticiales , Pulmón , Humanos , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/complicaciones , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Masculino , Persona de Mediana Edad , Enfermedades del Tejido Conjuntivo/complicaciones , Enfermedades del Tejido Conjuntivo/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Adulto , Anciano , Curva ROC , Tomografía Computarizada por Rayos X , Pleura/diagnóstico por imagen , Ultrasonografía/métodos , Sensibilidad y Especificidad
13.
Anaesthesiol Intensive Ther ; 56(1): 1-8, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38741438

RESUMEN

Throughout the past decades ultrasonography did not prove to be a procedure of choice if regarded as part of the routine bedside examination. The reason was the assumption defining the lungs and the bone structures as impenetrable by ultrasound. Only during the recent several years has the approach to the use of such tool in clinical daily routines changed dramatically to offer so-called point-of-care ultrasonography (POCUS). Both vertical and horizontal artefacts became valuable sources of information about the patient's clinical condition, assisting therefore the medical practitioner in differential diagnosis and monitoring of the patient. What is important is that the information is delivered in real time, and the procedure itself is non-invasive. The next stage marking the progress made in this area of diagnostic imaging is the development of arti-ficial intelligence (AI) based on machine learning algorithms. This article is intended to present the available, innovative solutions of the ultrasound systems, including Smart B-line technology, to ensure automatic identification process, as well as interpretation of B-lines in the given lung area of the examined patient. The article sums up the state of the art in ultrasound artefacts and AI applied in POCUS.


Asunto(s)
Inteligencia Artificial , Sistemas de Atención de Punto , Ultrasonografía , Humanos , Ultrasonografía/métodos , Artefactos , Enfermedades Respiratorias/diagnóstico por imagen , Sistema Respiratorio/diagnóstico por imagen
14.
J Clin Med ; 13(9)2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38730988

RESUMEN

Background: Heart failure (HF) affects around 60 million individuals worldwide. The primary aim of this study was to evaluate the efficacy of lung ultrasound (LUS) in managing HF with the goal of reducing hospital readmission rates. Methods: A systematic search was conducted on PubMed, Embase, Google Scholar, Web of Science, and Scopus, covering clinical trials, meta-analyses, systematic reviews, and original articles published between 1 January 2019 and 31 December 2023, focusing on LUS for HF assessment in out-patient settings. There is a potential for bias as the effectiveness of interventions may vary depending on the individuals administering them. Results: The PRISMA method synthesized the findings. Out of 873 articles identified, 33 were selected: 19 articles focused on prognostic assessment of HF, 11 centred on multimodal diagnostic assessments, and two addressed therapeutic guidance for HF diagnosis. LUS demonstrates advantages in detecting subclinical congestion, which holds prognostic significance for readmission and mortality during out-patient follow-up post-hospital-discharge, especially in complex scenarios, but there is a lack of standardization. Conclusions: there are considerable uncertainties in their interpretation and monitoring changes. The need for an updated international consensus on the use of LUS seems obvious.

15.
Eur Heart J Cardiovasc Imaging ; 25(9): 1216-1225, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-38606932

RESUMEN

AIMS: Lung ultrasound (LUS) is often used to assess congestion in heart failure (HF). In this study, we assessed the prognostic role of LUS in patients with HF at admission and hospital discharge, and in an outpatient setting, and explored whether clinical factors [age, sex, left ventricular ejection fraction (LVEF), and atrial fibrillation] impact the prognostic value of LUS findings. Further, we assessed the incremental prognostic value of LUS on top of the following two clinical risk scores: (i) the atrial fibrillation, haemoglobin, elderly, abnormal renal parameters, diabetes mellitus (AHEAD) and (ii) the Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) clinical risk scores. METHODS AND RESULTS: We pooled data on patients hospitalized for HF or followed up in outpatient clinics from international cohorts. We enrolled 1947 patients at admission (n = 578), discharge (n = 389), and in outpatient clinics (n = 980). The total LUS B-line count was calculated for the eight-zone scanning protocol. The primary outcome was a composite of rehospitalization for HF and all-cause death. Compared with those in the lower tertiles of B lines, patients in the highest tertiles were older, more likely to have signs of HF and had higher N-terminal pro b-type natriuretic peptide (NT-proBNP) levels. A higher number of B lines was associated with increased risk of primary outcome at discharge [Tertile 3 vs. Tertile 1: adjusted hazard ratio (HR): 5.74 (3.26-10.12), P < 0.0001] and in outpatients [Tertile 3 vs. Tertile 1: adjusted HR: 2.66 (1.08-6.54), P = 0.033]. Age and LVEF did not influence the prognostic capacity of LUS in different clinical settings. Adding B-line count to the MAGGIC and AHEAD scores improved net reclassification significantly in all three clinical settings. CONCLUSION: A higher number of B lines in patients with HF was associated with an increased risk of morbidity and mortality, regardless of the clinical setting.


Asunto(s)
Insuficiencia Cardíaca , Ultrasonografía , Humanos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/mortalidad , Femenino , Masculino , Pronóstico , Anciano , Ultrasonografía/métodos , Pulmón/diagnóstico por imagen , Persona de Mediana Edad , Medición de Riesgo , Estudios de Cohortes , Volumen Sistólico/fisiología
16.
Eur Heart J Cardiovasc Imaging ; 25(8): 1127-1135, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-38478596

RESUMEN

AIMS: Residual congestion in acute heart failure (AHF) is associated with poor prognosis. However, there is a lack of data on the prognostic value of changes in a combined assessment of in-hospital congestion. The present study sought to assess the association between in-hospital congestion changes and subsequent prognosis according to left ventricular ejection fraction (LVEF) classification. METHODS AND RESULTS: Patients (N = 244, 80.3 ± 7.6 years, 50.8% male) admitted for acute HF in two European tertiary care centres underwent clinical assessment (congestion score included dyspnoea at rest, rales, third heart sound, jugular venous distention, peripheral oedema, and hepatomegaly; simplified congestion score included rales and peripheral oedema), echocardiography, lung ultrasound, and natriuretic peptides (NP) measurement at admission and discharge. The primary outcome was a composite of all-cause mortality and/or HF re-hospitalization. In the 244 considered patients (95 HF with reduced EF, 57 HF with mildly reduced EF, and 92 HF with preserved EF), patients with limited improvement in clinical congestion score (hazard ratio 2.33, 95% CI 1.51-3.61, P = 0.0001), NP levels (2.29, 95% CI 1.55-3.38, P < 0.0001), and the number of B-lines (6.44, 95% CI 4.19-9.89, P < 0.001) had a significantly higher risk of outcome compared with patients experiencing more sizeable decongestion. The same pattern of association was observed when adjusting for confounding factors. A limited improvement in clinical congestion score and in the number of B-lines was related to poor prognosis for all LVEF categories. CONCLUSION: In AHF, the degree of congestion reduction assessed over the in-hospital stay period can stratify the subsequent event risk. Limited reduction in both clinical congestion and B-lines number are related to poor prognosis, irrespective of HF subtype.


Asunto(s)
Insuficiencia Cardíaca , Volumen Sistólico , Humanos , Masculino , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Femenino , Pronóstico , Volumen Sistólico/fisiología , Anciano , Anciano de 80 o más Años , Enfermedad Aguda , Ecocardiografía , Medición de Riesgo , Hospitalización/estadística & datos numéricos , Estudios de Cohortes
17.
Semin Arthritis Rheum ; 65: 152406, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38401294

RESUMEN

OBJECTIVES: Over the last years ultrasound has shown to be an important tool for evaluating lung involvement, including interstitial lung disease (ILD) a potentially severe systemic involvement in many rheumatic and musculoskeletal diseases (RMD). Despite the potential sensitivity of the technique the actual use is hampered by the lack of consensual definitions of elementary lesions to be assessed and of the scanning protocol to apply. Within the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group we aimed at developing consensus-based definitions for ultrasound detected ILD findings in RMDs and assessing their reliability in dynamic images. METHODS: Based on the results from a systematic literature review, several findings were identified for defining the presence of ILD by ultrasound (i.e., Am-lines, B-lines, pleural cysts and pleural line irregularity). Therefore, a Delphi survey was conducted among 23 experts in sonography to agree on which findings should be included and on their definitions. Subsequently, a web-reliability exercise was performed to test the reliability of the agreed definitions on video-clips, by using kappa statistics. RESULTS: After three rounds of Delphi an agreement >75 % was obtained to include and define B-lines and pleural line irregularity as elementary lesions to assess. The reliability in the web-based exercise, consisting of 80 video-clips (30 for pleural line irregularity, 50 for B-lines), showed moderate inter-reader reliability for both B-lines (kappa = 0.51) and pleural line irregularity (kappa = 0.58), while intra-reader reliability was good for both B-lines (kappa = 0.72) and pleural line irregularity (kappa = 0.75). CONCLUSION: Consensus-based ultrasound definitions for B-lines and pleural line irregularity were obtained, with moderate to good reliability to detect these lesions using video-clips. The next step will be testing the reliability in patients with ILD linked to RMDs and to propose a consensual and standardized protocol to scan such patients.


Asunto(s)
Técnica Delphi , Enfermedades Pulmonares Intersticiales , Ultrasonografía , Humanos , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Ultrasonografía/normas , Reproducibilidad de los Resultados , Pulmón/diagnóstico por imagen , Consenso
18.
Hemodial Int ; 28(2): 148-161, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38413047

RESUMEN

RATIONALE AND OBJECTIVES: Determining dry weight is crucial for optimizing hemodialysis, influencing efficacy, cardiovascular outcomes, and overall survival. Traditional clinical assessment methods for dry weight, relying on factors such as blood pressure and edema, frequently lack reliability. Lung ultrasound stands out as a promising tool for assessing volume status, given its non-invasiveness and reproducibility. This study aims to explore the role of Lung ultrasound in evaluating the impact of hemodialysis and ultrafiltration on extravascular lung water, with a specific focus on changes in B-lines post-hemodialysis compared to pre-hemodialysis. MATERIALS AND METHODS: The research encompassed searches across PubMed, WOS, and Scopus databases for studies related to lung ultrasound and hemodialysis. A meta-analysis was then performed to determine the mean differences in various parameters before compared to after, hemodialysis, including the number of B-lines, indexed end-inspiratory and end-expiratory inferior vena cava diameters, inferior vena cava collapsibility index, weight, blood pressure, and serum levels of NT-pro-BNP. RESULTS: Our meta-analysis, included 33 studies with 2301 hemodialysis patients, revealed a significant decrease in the number of B-lines post-hemodialysis (mean difference = 8.30, 95% CI [3.55 to 13.05]). Furthermore, there was a noteworthy reduction in inspiratory and expiratory inferior vena cava diameters post-hemodialysis (mean difference = 2.32, 95% CI [0.31 to 4.33]; mean difference = 4.05, 95% CI [2.44 to 5.65], respectively). Additionally, a significant positive correlation was observed between B-lines and the maximum inferior vena cava diameter both pre- and post-hemodialysis (correlation coefficient = 0.39; correlation coefficient = 0.32, respectively). CONCLUSION: These findings indicate the effectiveness of lung ultrasound in detection of volume overload and assessment of response to ultrafiltration in hemodialysis patients.


Asunto(s)
Agua Pulmonar Extravascular , Pulmón , Diálisis Renal , Ultrasonografía , Humanos , Diálisis Renal/métodos , Diálisis Renal/efectos adversos , Agua Pulmonar Extravascular/metabolismo , Ultrasonografía/métodos , Pulmón/diagnóstico por imagen
19.
Indian J Crit Care Med ; 28(2): 165-169, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38323257

RESUMEN

Background: Lung ultrasound (LUS) is a simple bedside tool to assess overhydration. Our study aimed to assess extravascular lung water (EVLW) using B-lines and correlate it with weaning, duration of mechanical ventilation, and mortality in critically ill patients admitted to the intensive care unit (ICU). Patients and methods: 150 mechanically ventilated ICU patients prospectively observed over 18 months, with their demographic and clinical data noted. Extravascular lung water was monitored using LUS in four intercostal spaces (ICS) from day 1 to day 5, day 7, day 10, and weekly thereafter. Pulmonary fluid burden was graded as low (1-10), moderate (11-20), and high (21-32). Weaning outcome, duration of weaning, mechanical ventilation, ICU stay, and mortality were compared in patients with and without EVLW. Results: Out of 150, 54 patients (36.0%) had EVLW. The mean lung score amongst our patients was 8.57 ± 6.0. The mean time for detection of EVLW was 1.43 ± 2.24 days. Lung score was low in 40 (26.67%) patients, moderate in 9 (6.00%) patients, and high in 5 (3.33%) patients. Incidence of weaning failure (p-value = 0.006), duration of weaning, mechanical ventilation, ICU stay (p-value < 0.0001 each), and overall mortality were significantly higher in patients with EVLW (p-value = 0.006). Conclusion: We conclude that a good proportion of critically ill patients have EVLW. Extravascular lung water significantly increases the duration of weaning, mechanical ventilation days, ICU stay, and overall mortality in critically ill patients. How to cite this article: Rajpal M, Talwar V, Krishna B, Mustafi SM. Assessment of Extravascular Lung Water Using Lung Ultrasound in Critically Ill Patients Admitted to Intensive Care Unit. Indian J Crit Care Med 2024;28(2):165-169.

20.
Blood Purif ; 53(3): 200-209, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37989110

RESUMEN

INTRODUCTION: Left ventricular diastolic dysfunction (LVDD) frequently occurs in haemodialysis patients and is associated with adverse outcomes. Lung ultrasound (LUS) has been recently proposed for the quantification of extravascular lung water through assessment of B-lines. LUS findings and their relationship with LVDD in clinically euvolemic haemodialysis patients were investigated in this study. METHODS: Echocardiography and LUS examinations were performed on each patient. Multivariate linear regression and forward stepwise logistic regression were performed to determine the relationship between B-lines and LVDD. A receiver operating characteristic (ROC) curve with area under the curve (AUC) was calculated to determine the accuracy of B-lines for evaluating LVDD. RESULTS: A total of 119 patients were enrolled. The number of B-lines was statistically related to echocardiographic parameters (LAVI, LVEDVI, E/A, and E/e') of diastolic function, while the relationship between B-lines and LVEF disappeared after adjusting for potential confounding factors. Additionally, compared with the mild B-line group (B-lines: <14), the moderate (B-lines: 14-30) and severe B-line groups (B-lines: >30) were associated with an increased risk of LVDD (OR 24.344, 95% CI 4.854-122.084, p < 0.001, and OR 94.552, 95% CI 9.617-929.022, p < 0.001, respectively). Furthermore, the AUC of the ROC curve for B-lines predicting LVDD was 0.845, and the cut-off of B-lines was 14.5 (sensitivity 64.91%, specificity 93.55%). CONCLUSION: LUS B-lines were closely associated with left ventricular diastolic function in clinically euvolemic haemodialysis patients. Moreover, our findings suggested a B-line ≥14.5 as a reliable cut-off value for identifying patients with LVDD. LUS B-lines may be used as a novel indicator for evaluating LVDD.


Asunto(s)
Diálisis Renal , Disfunción Ventricular Izquierda , Humanos , Diálisis Renal/efectos adversos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Ecocardiografía/efectos adversos , Curva ROC , Pulmón , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA