1.
BMC Ophthalmol ; 24(1): 410, 2024 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-39300358

RESUMEN

PURPOSE: To compare the biometric measurements obtained from the Pentacam AXL Wave, IOLMaster 700, and ANTERION and calculate the recommended intraocular lens power using the Barrett Formulae. METHODS: This was a retrospective cross-sectional study of patients who underwent biometry using the Pentacam AXL Wave, IOLMaster 700, and ANTERION. Flat keratometry (K1), steep keratometry (K2), anterior chamber depth (ACD), and axial length (AL) from each device were measured and compared. These parameters were used to calculate the recommended IOL powers using the Barrett formula. RESULTS: The study included 252 eyes of 153 patients. The IOLMaster had the highest acquisition rate among the two biometers. The Pentacam obtained the shortest mean AL, the IOLMaster measured the highest mean keratometry values, and the ANTERION measured the highest mean ACD. In terms of pairwise comparisons, keratometry and axial length were not significantly different between the Pentacam-IOLMaster and ANTERION-IOLMaster groups, while the rest of the pairwise comparisons were statistically significant. In nontoric and toric eyes, 35-45% of patients recommended the same sphere of IOL power. In another 30-40%, the Pentacam and ANTERION recommended an IOL power one step greater than that of the IOLMaster-derived data. 50% of the study population recommended the same toric-cylinder IOL power. CONCLUSIONS: The Pentacam AXL Wave, IOLMaster 700, and ANTERION can reliably provide data for IOL power calculations; however, these data are not interchangeable. In nontoric and toric eyes, 35-45% of cases recommended the same sphere IOL power, and in another 30-40%, the Pentacam and ANTERION recommended one-step higher IOL power than the IOLMaster-derived data. In targeting emmetropia, selecting the first plus IOL power is advisable when using the Pentacam and ANTERION to approximate the IOL power calculations recommended by the IOLMaster 700.


Asunto(s)
Biometría , Interferometría , Lentes Intraoculares , Tomografía de Coherencia Óptica , Humanos , Estudios Retrospectivos , Estudios Transversales , Masculino , Biometría/instrumentación , Biometría/métodos , Femenino , Persona de Mediana Edad , Interferometría/instrumentación , Interferometría/métodos , Anciano , Tomografía de Coherencia Óptica/métodos , Tomografía de Coherencia Óptica/instrumentación , Longitud Axial del Ojo/diagnóstico por imagen , Adulto , Anciano de 80 o más Años , Refracción Ocular/fisiología , Óptica y Fotónica , Cámara Anterior/diagnóstico por imagen
2.
Front Med (Lausanne) ; 11: 1418566, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39247635

RESUMEN

Objective: To investigate the pathogenesis of Primary Angle-Closure Glaucoma (PACG) and its relationship with the anatomical structure of the anterior segment by obtaining biometric parameters using the IOL-Master 700. Methods: A retrospective case-control study was conducted. Clinical data from 39 PACG patients and 40 normal controls treated at the Aier Eye Hospital affiliated with Wuhan University from January to December 2022 were collected. Anterior chamber depth (AC), white-to-white (WTW), lens thickness (LT), central corneal thickness (CCT), axial length (AL), corneal curvature (K1), corneal curvature (K2), and lens position (LP) were measured using the IOL-Master 700 to analyze the characteristics and differences in the anterior segment structure of both groups. Statistical methods included independent sample t-tests and logistic regression analysis. Results: Significant differences were found in the anterior segment biometric parameters between PACG patients and normal controls (p < 0.05). Anterior chamber depth, white-to-white, lens thickness, central corneal thickness, axial length, and K2 were all related to the occurrence of PACG (p < 0.05). The occurrence of PACG was negatively correlated with ACD, CCT, and AL (OR = 0.12-0.64, p < 0.05), and positively correlated with LT. Conclusion: Compared to the normal control group, PACG patients in the Hubei region have a smaller anterior segment space, narrower angles, thicker lens, thinner cornea, shorter axial length, flatter cornea, and more anteriorly positioned lens.

3.
BMC Ophthalmol ; 24(1): 326, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39103785

RESUMEN

PURPOSE: To research the accuracy of intraocular lens (IOL) calculation formulas and investigate the effect of anterior chamber depth (ACD) and lens thickness (LT) measured by swept-source optical coherence tomography biometer (IOLMaster 700) in patients with posterior chamber phakic IOL (PC-pIOL). METHODS: Retrospective case series. The IOLMaster 700 biometer was used to measure axial length (AL) and anterior segment parameters. The traditional formulas (SRK/T, Holladay 1 and Haigis) with or without Wang-Koch (WK) AL adjustment, and new-generation formulas (Barret Universal II [BUII], Emmetropia Verifying Optical [EVO] v2.0, Kane, Pearl-DGS) were utilized in IOL power calculation. RESULTS: This study enrolled 24 eyes of 24 patients undergoing combined PC-pIOL removal and cataract surgery at Xiamen Eye Center of Xiamen University, Xiamen, Fujian, China. The median absolute prediction error in ascending order was EVO 2.0 (0.33), Kane (0.35), SRK/T-WKmodified (0.42), Holladay 1-WKmodified (0.44), Haigis-WKC1 (0.46), Pearl-DGS (0.47), BUII (0.58), Haigis (0.75), SRK/T (0.79), and Holladay 1 (1.32). The root-mean-square absolute error in ascending order was Haigis-WKC1 (0.591), Holladay 1-WKmodified (0.622), SRK/T-WKmodified (0.623), EVO (0.673), Kane (0.678), Pearl-DGS (0.753), BUII (0.863), Haigis (1.061), SRK/T (1.188), and Holladay 1 (1.513). A detailed analysis of ACD and LT measurement error revealed negligible impact on refractive outcomes in BUII and EVO 2.0 when these parameters were incorporated or omitted in the formula calculation. CONCLUSION: The Kane, EVO 2.0, and traditional formulas with WK AL adjustment displayed high prediction accuracy. Furthermore, the ACD and LT measurement error does not exert a significant influence on the accuracy of IOL power calculation formulas in highly myopic eyes implanted with PC-pIOL.


Asunto(s)
Biometría , Catarata , Lentes Intraoculares Fáquicas , Refracción Ocular , Tomografía de Coherencia Óptica , Humanos , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Femenino , Masculino , Persona de Mediana Edad , Biometría/métodos , Refracción Ocular/fisiología , Catarata/complicaciones , Adulto , Óptica y Fotónica , Reproducibilidad de los Resultados , Anciano , Longitud Axial del Ojo/diagnóstico por imagen , Longitud Axial del Ojo/patología , Cámara Anterior/diagnóstico por imagen , Agudeza Visual/fisiología , Implantación de Lentes Intraoculares/métodos
4.
BMC Pulm Med ; 24(1): 418, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39198799

RESUMEN

BACKGROUND: Chronic obstructive pulmonary disease (COPD) is a persistent, chronic inflammatory disease of the lungs. Tiotropium, used in the treatment of COPD, is a muscarinic receptor antagonist that provides long-acting bronchodilation. Our study aimed to investigate the effects of Tiotropium on anterior chamber parameters. METHODS: The study was conducted as an observational cross-sectional and prospectively between October 2023 and April 2024. Patients were examined in three groups: Group 1 consisted of untreated COPD patients; Group 2 consisted of healthy volunteers similar age and gender, and Group 3 included COPD patients receiving Tiotropium 18 mcg via HandiHaler. Anterior chamber parameters, intraocular pressure values, and photopic-mesopic pupil diameters were measured at the initial visit for Group 1 and Group 2 patients, and at the third month of treatment for Group 3 patients. RESULTS: Thirty-six patients were included in each group in the study. No significant differences were observed in ocular findings between the patient and control groups. In COPD patients receiving Tiotropium, narrowing of angle parameters, an increase in photopic-mesopic pupil diameters, and intraocular pressure were observed at the third month of treatment. CONCLUSION: This study is the first research that investigate the effects of Tiotropium on anterior chamber parameters, pupil diameters, and intraocular pressure in COPD treatment. In conclusion, patients with COPD receiving Tiotropium therapy for three months showed narrowing in angle parameters, an increase in intraocular pressure, and photopic-mesopic pupil diameter; however, no patients developed drug-induced acute angle closure glaucoma. TRIAL REGISTRATION: An independent ethics committee approved the study (Giresun EAH KEAK 2023/180 and 9.10.2023/02) which was performed in accordance with the Declaration of Helsinki, Guidelines for Good Clinical Practice. The study was conducted as prospectively, observational case-control. The Clinical Trial Number obtained for the study is NCT06525051 and was taken on 2024-07-29.


Asunto(s)
Broncodilatadores , Presión Intraocular , Enfermedad Pulmonar Obstructiva Crónica , Bromuro de Tiotropio , Humanos , Bromuro de Tiotropio/uso terapéutico , Bromuro de Tiotropio/administración & dosificación , Enfermedad Pulmonar Obstructiva Crónica/tratamiento farmacológico , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Femenino , Masculino , Estudios Transversales , Persona de Mediana Edad , Estudios Prospectivos , Anciano , Presión Intraocular/efectos de los fármacos , Broncodilatadores/uso terapéutico , Cámara Anterior/efectos de los fármacos , Pupila/efectos de los fármacos
5.
Artículo en Inglés | MEDLINE | ID: mdl-39206080

RESUMEN

Background: The effects of trabeculectomy on anterior segment parameters have been widely investigated. However, the stabilization time for various glaucoma types after trabeculectomy remains debatable. We investigated the effect of mitomycin C-augmented trabeculectomy on ocular anterior segment parameters in primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (PXG) during short-term follow-up using the Pentacam HR. Methods: In this retrospective observational study, consecutive patients diagnosed with medically uncontrolled POAG or PXG who underwent MMC-augmented trabeculectomy were recruited. All individuals underwent detailed ocular examinations. All trabeculectomies were performed by a single surgeon using the same technique. Anterior segment parameters, including anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), and central corneal thickness (CCT) were measured using the Pentacam HR, along with intraocular pressure (IOP) using a Goldmann applanation tonometer, pre-operatively and at 1-week, 1-month, and 3-month post-operative visits. Results: We included 80 patients with a median (range) age of 58.0 (41.0-86.0) years having a nearly similar sex ratio. The study groups were matched according to sex and age (both P > 0.05). The group-by-time interaction was significant for CCT and ACV (both P < 0.05) but not for IOP, ACD, and ACA (all P > 0.05). The mean (standard deviation [SD]) IOP, ACD, and ACA were comparable between groups (all P > 0.05) during the 3-month period; however, they changed significantly over time in both groups (all P < 0.001). The mean CCT and ACV were comparable between groups at each time point (all P > 0.05), except at the 1-month post-operative visit, at which the mean (SD) ACV was significantly lower in the PXG group (P < 0.05). We found a comparable mean (SD) CCT between paired visits in each group (all P > 0.05), except for the mean (SD) CCT at 3 months, which was significantly lower than that at the 1-month post-operative visit in the PXG group (P < 0.05). We found a comparable mean (SD) ACV between paired visits in each group (all P > 0.05); however, it was significantly lower at the 1-month post-operative versus the baseline visit in both groups and resumed a significantly higher value at the 1-month versus the 1-week visit and at the 3-month versus the 1-month visit in the PXG group (all P < 0.05). Conclusions: We observed significant changes in IOP, ACD, and ACA over 3 months after post-augmented trabeculectomy in eyes with POAG and PXG; however, the majority of anterior segment parameters were comparable between the two groups. Further large-scale studies with longer follow-up periods should be conducted to verify the post-operative fluctuations in these parameters in POAG and PXG.

6.
Int Ophthalmol ; 44(1): 268, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38913127

RESUMEN

PURPOSE: To evaluate the effect of pregnancy on the anterior chamber, corneal parameter, and intraocular pressure measurements; and compare the results between trimesters, postpartum and non-pregnant healthy age-matched women. METHODS: This prospective study included 41 pregnant women and 53 non-pregnant women. Four measurements were taken from the pregnant women, in each trimester and postpartum third month, and once from the control group. Of the individuals included in the study, anterior chamber depth (ACD), anterior chamber volume (ACV), K1 (flat keratometry), K2 (steep keratometry), Kmean (mean value of K1 and K2), anterior chamber angle (ACA), central corneal thickness (CCT), thinnest corneal thickness (TCT), astigmatism value (AST), corneal volume (CV), biometry, axial length (AL), spherical equivalent (SFEQ), intraocular lens power (ILP), VA (visual acuity) datas were recorded. RESULTS: We observed a statistically significant decrease in K2, CCT, ACD, AL and CV in the postpartum period (p = 0.025, p < 0.001, p = 0.029, p = 0.005, p = 0.004 respectively) and a statistically significant increase in ACV, CCT, and TCT as the gestational week progressed in the pregnant group (p = 0.007, p < 0.001, p = 0.025, respectively). A statistically significant decrease in IOP towards to the third trimester, and an increase in the postpartum period was observed (p < 0.001). We did not observe statistically significant changes in K1, Kmean, AST, ACA, VA, ILP, and SFEQ values. CONCLUSION: It is important to investigate the physiological changes that may occur during pregnancy, distinguish them from pathological changes, and avoid unnecessary treatment. We consider that it's also important to guide the timing of anterior segment surgeries such as cataract and refractive surgery and to prescribe glasses/contact lenses.


Asunto(s)
Presión Intraocular , Periodo Posparto , Trimestres del Embarazo , Humanos , Femenino , Estudios Prospectivos , Embarazo , Adulto , Periodo Posparto/fisiología , Trimestres del Embarazo/fisiología , Presión Intraocular/fisiología , Segmento Anterior del Ojo/diagnóstico por imagen , Adulto Joven , Agudeza Visual/fisiología , Biometría/métodos , Córnea/diagnóstico por imagen , Córnea/anatomía & histología , Cámara Anterior/diagnóstico por imagen
7.
BMC Ophthalmol ; 24(1): 259, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38880899

RESUMEN

BACKGROUND: The anatomic structure of the anterior chamber (AC) helps to explain differences in refractive status in school-aged children and is closely associated with primary angle closure (PAC). The aim of this study was to quantify and analyze the anterior chamber and angle (ACA) characteristics in Chinese children with different refractive status by swept-source optical coherence tomography (SS-OCT). METHODS: In a cross-sectional observational study, 383 children from two primary schools in Shandong Province, China, underwent a complete ophthalmic examination. First, the anterior chamber depth (ACD), anterior chamber width (ACW), angle-opening distance (AOD), and trabecular-iris space area (TISA) were evaluated automatically using a CASIA2 imaging device. AOD and TISA were measured at 500, 750 µm nasal (N1 and N2, respectively), and temporal (T1 and T2, respectively) to the scleral spur (SS). Cycloplegic refraction and axial length (AL) were then measured. According to spherical equivalent refraction (SER), the children were assigned to hyperopic (SER > 0.50D), emmetropic (-0.50D < SER ≤ 0.50D), and myopic groups (SER ≤ -0.50D). RESULTS: Out of the 383 children, 349 healthy children (160 girls) with a mean age of 8.23 ± 1.06 years (range: 6-11 years) were included. The mean SER and AL were - 0.10 ± 1.57D and 23.44 ± 0.95 mm, respectively. The mean ACD and ACW were 3.17 ± 0.24 mm and 11.69 ± 0.43 mm. The mean AOD were 0.72 ± 0.25, 0.63 ± 0.22 mm at N1, T1, and 0.98 ± 0.30, 0.84 ± 0.27 mm at N2, T2. The mean TISA were 0.24 ± 0.09, 0.22 ± 0.09mm2 at N1, T1, and 0.46 ± 0.16, 0.40 ± 0.14mm2 at N2, T2. The myopic group had the deepest AC and the widest angle. Compared with boys, girls had shorter AL, shallower ACD, narrower ACW, and ACA (all p < 0.05). By Pearson's correlation analysis, SER was negatively associated with ACD, AOD, and TISA. AL was positively associated with ACD, ACW, AOD, and TISA. In the multiple regression analysis, AOD and TISA were associated with deeper ACD, narrower ACW, and longer AL. CONCLUSION: In primary school students, the myopic eyes have deeper AC and wider angle. ACD, ACW, AOD, and TISA all increase with axial elongation. ACA is highly correlated with deeper ACD.


Asunto(s)
Cámara Anterior , Refracción Ocular , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Estudios Transversales , Niño , Femenino , Masculino , Cámara Anterior/diagnóstico por imagen , Cámara Anterior/patología , China/epidemiología , Refracción Ocular/fisiología , Glaucoma de Ángulo Cerrado/fisiopatología , Glaucoma de Ángulo Cerrado/diagnóstico , Glaucoma de Ángulo Cerrado/etnología , Errores de Refracción/fisiopatología , Pueblos del Este de Asia
8.
Sci Rep ; 14(1): 12558, 2024 05 31.
Artículo en Inglés | MEDLINE | ID: mdl-38822089

RESUMEN

This study investigated the underlying causes of the myopic outcomes of the optic-based newer formulas (Barrett Universal II, EVO 2.0, Kane, Hoffer-QST and PEARL-DGS) in long Korean eyes with Alcon TFNT intraocular lens (IOL) implantation. Postoperative data from 3100 randomly selected eyes of 3100 patients were analyzed to compare the reference back-calculated effective lens positions (ELPs) based on the Haigis formula using conventional axial length (AL) and Cooke-modified AL (CMAL) with the predicted ELP of each single- and triple-optimized Haigis formula applied to AL- and CMAL. Contrary to the AL-applied Haigis formula, the predicted ELP curve of the CMAL-applied, single-optimized Haigis formula, simulating the methods of the newer formulas, exhibited a significant upward deviation from the back-calculated ELP in long eyes. The relationship between the AL and anterior chamber depth in our long-eyed population differed from that in the base population of the PEARL-DGS formula. The myopic outcomes in long eyes appeared to stem from the substantial overestimation of the postoperative IOL position with AL modification, leading to the implantation of inappropriately higher-powered IOLs. This discrepancy may be attributed to the ethnic differences in ocular biometrics, particularly the relatively smaller anterior segment in East Asian patients with long AL.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Miopía , Humanos , Miopía/cirugía , Masculino , Femenino , Persona de Mediana Edad , Implantación de Lentes Intraoculares/métodos , República de Corea , Anciano , Refracción Ocular , Longitud Axial del Ojo/patología , Biometría/métodos , Adulto , Agudeza Visual , Resultado del Tratamiento , Pueblo Asiatico
9.
Cureus ; 16(4): e58223, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38745798

RESUMEN

INTRODUCTION: Evaluation of anterior segment parameters is crucial in ophthalmic procedures such as intraocular surgeries and contact lens fitting. However, the use of tropicamide in diabetic patients presents challenges due to its potential impact on biometric measurements. This study aims to investigate and compare the effects of 0.5% and 1% tropicamide on anterior segment parameters in diabetic patients. METHODS: This double-masked randomized clinical trial enrolled 98 patients with diabetes mellitus. Participants were randomly assigned to receive either 0.5% or 1% tropicamide. Anterior segment parameters were measured using Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) before and 30 minutes after tropicamide administration. Parameters included anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), keratometry, central corneal thickness (CCT), white-to-white distance (WTW), and pupillary diameter (PD). RESULTS: Both concentrations of 0.5% and 1% tropicamide induced significant changes in anterior segment parameters. There was a notable increase in PD (2.99 ± 0.62, 3.11 ± 0.55, respectively, both P-values < 0.001), ACD (both 0.10 ± 0.05, both P-values < 0.001), ACV (16.69 ± 9.56, 17.51 ± 9.26, respectively, both P-values < 0.001), and WTW (0.06 ± 0.14, 0.03 ± 0.30, respectively, both P-values < 0.001), along with a decrease in ACA (-3.50 ± 10.65, -3.30 ± 6.87, P-value < 0.001 and P-value=0.001, respectively), and CCT (-6.10 ± 8.06, -6.39 ± 9.97, respectively, both P-values < 0.001) post-dilation. However, no significant changes were observed in keratometry (front Km (-0.03 ± 0.19, -0.04 ± 0.21, respectively), back Km (0.01 ± 0.05, 0.004 ± 0.05, respectively), P-values> 0.05). CONCLUSION: Both concentrations of tropicamide exhibited comparable effects on anterior segment parameters in diabetic patients. These post-dilation changes should be considered for accurate intraocular lens power calculation and decision-making for cataract, phakic intraocular lens, and refractive surgeries.

10.
J Clin Med ; 13(9)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38731065

RESUMEN

Background: This study aimed to compare keratometry and anterior chamber depth (ACD) changes after XEN implantation in primary open-angle glaucoma (POAG) cases over a 3-month follow-up period. Methods: Twenty patients with POAG who underwent XEN63 implantation, either standalone or combined with cataract surgery, were included. Preoperative data, including best-corrected visual acuity (BCVA), refraction, gonioscopy, ophthalmoscopy, intraocular pressure (IOP) evaluation, and axial length, were collected. Corneal topography and ACD measurements were assessed preoperatively and at postoperative days 1, 7, 15, 30, 60, and 90. Each patient's eye that underwent XEN surgery was included in the study group, with the fellow eye serving as a control. Results: In the study group, there was a significant decrease in IOP after XEN stent implantation at all investigated time intervals (p < 0.05). However, changes in mean ACD did not show statistically significant differences at any follow-up examination in both the study and control groups. Additionally, keratometry readings revealed no significant changes in total astigmatism or steep keratometry values in either group. Conclusions: XEN implantation in POAG cases resulted in a significant decrease in IOP over the 3-month follow-up period. However, there were no significant changes observed in mean ACD or keratometry readings, indicating stability in these parameters post-XEN implantation. These findings suggest that XEN implantation may be an effective option for IOP reduction without affecting corneal curvature or ACD in POAG patients.

11.
J Med Imaging (Bellingham) ; 11(2): 026003, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38606184

RESUMEN

Purpose: Timely detection and treatment of visual impairments and age-related eye diseases are essential for maintaining a longer, healthier life. However, the shortage of appropriate medical equipment often impedes early detection. We have developed a portable self-imaging slit-light device utilizing NIR light and a scanning mirror. The objective of our study is to assess the accuracy and compare the performance of our device with conventional nonportable slit-lamp microscopes and anterior segment optical coherence tomography (AS-OCT) for screening and remotely diagnosing eye diseases, such as cataracts and glaucoma, outside of an eye clinic. Approach: The NIR light provides an advantage as measurements are nonmydriatic and less traumatic for patients. A cross-sectional study involving Japanese adults was conducted. Cataract evaluation was performed using photographs captured by the device. Van-Herick grading was assessed by the ratio of peripheral anterior chamber depth to peripheral corneal thickness, in addition to the iridocorneal angle using Image J software. Results: The correlation coefficient between values obtained by AS-OCT, and our fabricated portable scanning slit-light device was notably high. The results indicate that our portable device is equally reliable as the conventional nonportable slit-lamp microscope and AS-OCT for screening and evaluating eye diseases. Conclusions: Our fabricated device matches the functionality of the traditional slit lamp, offering a cost-effective and portable solution. Ideal for remote locations, healthcare facilities, or areas affected by disasters, our scanning slit-light device can provide easy access to initial eye examinations and supports digital eye healthcare initiatives.

12.
Int Ophthalmol ; 44(1): 160, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38536560

RESUMEN

PURPOSE: To compare anterior chamber angle (ACA) parameters measured by Anterior Segment Optical Coherence Tomography (ASOCT) and biometric parameters measured by Swept-Source (SS) OCT-based biometry among patients with suspected occludable angles and open angles. METHODS: An analytical, cross-sectional study was performed on subjects attending our ophthalmology outpatient department with suspected occludable angles (van Herick grades 0, 1, and 2) in group 1, and with open angles (van Herick grades 3 and 4) in group 2. Each subject underwent a complete ophthalmic examination to exclude any intraocular pathology like cataract. We recruited 128 eyes of 64 subjects, 34 in group 1 and 30 in group 2. Each eye was henceforth subjected to ASOCT (Spectralis, Heidelberg Engineering, Heidelberg) and SS-OCT-based optical biometry (IOL Master 700, Carl Zeiss Meditec AG). Anatomical parameters were recorded and compared between the two groups. RESULTS: The main outcome measures of the study included nine ASOCT parameters (central corneal thickness [CCT], lens vault, AOD750, ACA, TISA750 [nasal and temporal], and ACW) and five optical biometric parameters (CCT, ACD, WTW, LT, and axial length). We found a significant difference (p < 0.05) among all the anatomical parameters between the two groups, except CCT which was not significantly different (p = 0.297). CONCLUSIONS: ASOCT and SSOCT biometry overcome the challenges of gonioscopy and allow screening for angle closure disease in otherwise normal subjects. ASOCT may serve as an alternative to gonioscopy as it clearly separates occludable angles from open angles in a non-invasive and objective manner.


Asunto(s)
Glaucoma de Ángulo Cerrado , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Estudios Transversales , Presión Intraocular , Glaucoma de Ángulo Cerrado/diagnóstico , Glaucoma de Ángulo Cerrado/patología , Cámara Anterior/diagnóstico por imagen , Cámara Anterior/patología , Biometría , Gonioscopía , Segmento Anterior del Ojo/diagnóstico por imagen , Segmento Anterior del Ojo/patología
13.
Diagnostics (Basel) ; 14(5)2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38473032

RESUMEN

The VEMoS-AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT), which is recognized as the gold standard for the performance of an agreement analysis. A biometric analysis was performed three consecutive times in 120 healthy eyes of 120 patients aged between 18 and 40 years with the SD-OCT system, and afterwards, a single measurement was obtained with the SS-OCT system. Within-subject standard deviations were 0.004 mm, 4.394 µm, and 0.017 mm for axial length (AL), central corneal thickness (CCT), and anterior chamber depth (ACD) measures obtained with the SD-OCT biometer, respectively. The agreement between devices was good for AL (limits of agreement, LoA: -0.04 to 0.03 mm) and CCT (LoA: -4.36 to 14.38 µm), whereas differences between devices were clinically relevant for ACD (LoA: 0.03 to 0.21 mm). In conclusion, the VEMoS-AXL system provides consistent measures of anatomical parameters, being most of them interchangeable with those provided by the SS-OCT-based gold standard.

14.
Ophthalmic Res ; 67(1): 248-256, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38527448

RESUMEN

INTRODUCTION: This study aimed to determine the interchangeability of bilateral anterior chamber depth (ACD) in intraocular lens (IOL) power calculations for cataractous eyes and refractive outcomes using the unaffected fellow eye's ACD in subluxated crystalline lenses. METHODS: The predicted postoperative spherical equivalent (SE) calculated using the Kane formula with and without fellow eye's ACD in 202 cataract patients was compared. Refractive outcomes of the newer formulas (the Kane, Barrett Universal II [BUII], and Pearl-DGS formulas) with affected eye's ACD and with unaffected fellow eye's ACD were compared in 33 eyes with lens subluxation (the affected eye) undergoing in-the-bag IOL implantation. The SD of the prediction error (PE) was assessed using the heteroscedastic method. RESULTS: In 202 paired cataractous eyes, no marked ACD difference was found bilaterally; the predicted SE obtained without the fellow eye's ACD was comparable with that calculated with the fellow eye one (p = 0.90), with a mean absolute difference of 0.03 ± 0.03 D. With the affected eye AL, keratometry, and ACD, the median absolute error (MedAE) was 0.38-0.64 D, and the percentage of PE within ±0.50 D was 30.30-57.58%. The unaffected eye's ACD improved the results (MedAE, 0.35-0.49 D; the percentage of PE within ±0.50 D, 54.55-63.64%). The SDs of the BUII (0.82 D) and Pearl-DGS formulas (0.87 D) with the affected eye's ACD were significantly larger than those of the Kane and Pearl-DGS formulas (both 0.69 D) with the unaffected eye's ACD. CONCLUSION: Bilateral ACD was interchangeable in IOL power calculation for cataractous eyes when using the Kane formula. Unaffected eye's ACD in lieu of affected eye's ACD can enhance the accuracy of newer formulas in patients with unilateral subluxated lenses undergoing in-the-bag IOL implantation.


Asunto(s)
Cámara Anterior , Subluxación del Cristalino , Lentes Intraoculares , Refracción Ocular , Humanos , Masculino , Femenino , Anciano , Refracción Ocular/fisiología , Persona de Mediana Edad , Subluxación del Cristalino/cirugía , Subluxación del Cristalino/diagnóstico , Subluxación del Cristalino/fisiopatología , Adulto , Agudeza Visual , Estudios Retrospectivos , Óptica y Fotónica , Implantación de Lentes Intraoculares/métodos , Biometría/métodos , Anciano de 80 o más Años
15.
Int Ophthalmol ; 44(1): 62, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38345699

RESUMEN

PURPOSE: This study evaluated the relationship between refractive outcomes and postoperative anterior chamber depth (ACD, measured from corneal epithelium to lens) measured by swept-source optical coherence tomography (SS-OCT), optical low-coherence reflectometry (OLCR), and Scheimpflug devices under the undilated pupil. METHODS: Patients undergoing cataract phacoemulsification with intraocular lens (IOL) implantation in a hospital setting were enrolled. Postoperative ACD (postACD) was performed with an SS-OCT device, an OLCR device, and a Scheimpflug device at least 1 month after cataract surgery. After adjusting the mean predicted error to 0, differences in refractive outcomes were calculated with the Olsen formula using actual postACD measured from 3 devices and predicted value. RESULTS: Overall, this comparative case study included 69 eyes of 69 patients, and postACD measurements were successfully taken using all 3 devices. The postACD measured with the SS-OCT, OLCR, and Scheimpflug devices was 4.59 ± 0.30, 4.50 ± 0.30, and 4.54 ± 0.32 mm, respectively. Statistically significant differences in postACD were found among 3 devices (P < 0.001), with intraclass correlation coefficients (ICCs) and Bland-Altman showing good agreement. No significant difference in median absolute error was found with the Olsen formula using actual postACD obtained with 3 devices. Percentage prediction errors were within ± 0.50 D in 65% (OLCR), 70% (Scheimpflug), and 67% (SS-OCT) calculated by actual postACD versus 64% by predicted value. CONCLUSION: Substantial agreement was found in postACD measurements obtained from the SS-OCT, OLCR, and Scheimpflug devices, with a trend toward comparable refractive outcomes in the Olsen formula. Meanwhile, postACD measurements may be potentially superior for the additional enhancement of refractive outcomes.


Asunto(s)
Catarata , Cristalino , Lentes Intraoculares , Humanos , Cámara Anterior/diagnóstico por imagen , Longitud Axial del Ojo , Refracción Ocular , Catarata/diagnóstico , Tomografía de Coherencia Óptica/métodos , Biometría/métodos , Reproducibilidad de los Resultados
16.
BMC Ophthalmol ; 24(1): 74, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38369454

RESUMEN

BACKGROUND: An enhanced monofocal intraocular lenses (IOLs) (Tecnis Eyhance ICB00 and Tecnis Eyhance Toric DIU) has been developed to enhance intermediate vision while avoiding the disadvantages of multifocal IOLs. Although many studies have demonstrated the improvement of intermediate visual acuity with enhanced monofocal IOLs, it is not known specifically for which patients these IOLs should be recommended or avoided. In this study, we aim to find out which ocular parameters affect vision performance and photic phenomenon of ICB00 or DIU at different distances. METHODS: Patients who underwent cataract surgery with ICB00 or DIU, performed by a single surgeon, were included. Before surgery, the patients' age, gender, axial length, anterior chamber depth, spherical aberration Z (4,0), vertical coma, horizontal coma, angle kappa (κ), angle alpha (α), and other ocular parameters were investigated. One month after surgery, uncorrected near visual acuity (UNVA at 40 cm), uncorrected intermediate visual acuity (UIVA at 66 cm), uncorrected distance logMAR visual acuity (UDVA), IOL decentration, and quality of vision (QoV) questionnaires were conducted. RESULTS: A total of 43 patients (58 eyes) were included. The results of the univariate linear regression analyses showed a negative correlation between spherical aberration and logMAR UNVA and UIVA (p = 0.003, ß=-0.51 and p = 0.018, ß=-0.23, respectively) and a positive correlation between angle α and logMAR UIVA (p = 0.036, ß = 0.19). Deeper anterior chamber depth (ACD) was associated with poorer total QoV (p = 0.018, ß = 14.43), particularly in glare, halo, blur, and fluctuation perception. A higher degree of IOL decentration tended to decrease UNVA and UIVA (Pearson correlation coefficient, r = 0.336 and r = 0.221, respectively); however, no significant effect was observed on UDVA (Pearson correlation coefficient, r = 0.042). CONCLUSIONS: In enhanced monofocal IOLs, a higher level of spherical aberration is associated with better performance in UNVA and UIVA, whereas a larger angle α has a negative impact. A deeper ACD negatively affects the QoV.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares/métodos , Coma , Sensibilidad de Contraste , Visión Ocular , Diseño de Prótesis , Satisfacción del Paciente , Refracción Ocular
17.
Int Ophthalmol ; 44(1): 34, 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38332205

RESUMEN

PURPOSE: To explore the associations between central anterior chamber depth (CACD) and other anterior segment biometric parameters and to determine the possible determinants of CACD in short, normal, and long eyes. METHODS: The biometric data of pre-operation patients aged 50-80 years with coexisting cataract and primary angle-closure disease or senile cataract were reviewed. Axial length (AL), CACD, lens thickness (LT), central corneal thickness (CCT), and white-to-white distance (WTW) were measured by Lenstar optical biometry (Lenstar 900). The data of 100 normal eyes (AL = 22 to 26 mm), 100 short eyes (AL ≤ 22 mm), and 100 long eyes (AL ≥ 26 mm) were consecutively collected for subsequent analyses. RESULTS: The mean age of the subjects was 66.60 ± 7.85 years, with 25.7% of the sample being men. Both CACD and WTW were found to be smallest in short eyes and were smaller in normal eyes than in long eyes (F = 126.524, P < 0.001; F = 28.458, P < 0.001). The mean LT was significantly thicker in short eyes than in normal and long eyes (4.66 mm versus 4.49 mm versus 4.40 mm; F = 18.099, P < 0.001). No significant differences were observed in CCT between the three AL groups (F = 2.135, P = 0.120). Stepwise regression analysis highlighted AL, LT, and WTW as three independent factors associated with CACD in the normal AL group. In the short AL group and long AL group, LT and WTW were independent factors associated with CACD. CONCLUSIONS: CACD increases as AL elongates and reaches a peak when AL exceeds 26 mm. Furthermore, CACD showed inverse correlation with LT and positive correlation with WTW. A relatively small WTW results in an anteriorly positioned lens, and thus, a decrease in CACD.


Asunto(s)
Catarata , Cristalino , Lentes Intraoculares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Cristalino/diagnóstico por imagen , Catarata/complicaciones , Catarata/diagnóstico , Biometría/métodos , Cámara Anterior/diagnóstico por imagen , Longitud Axial del Ojo
18.
Int Ophthalmol ; 44(1): 15, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38321260

RESUMEN

PURPOSE: This study aims to investigate the influence of anterior chamber depth (ACD) and vault on the anterior chamber angle (ACA) morphology in myopic individuals implanted with posterior chamber phakic intraocular lenses. METHODS: This retrospective case series involved 231 eyes receiving a 13.2-mm implantable collamer lens (ICL). Preoperative anterior chamber anatomy was assessed using anterior segment optical coherence tomography (AS-OCT) and optical tomography, while postoperative evaluation employed AS-OCT. ACA morphology was characterized pre- and postoperatively through trabecular iris angle (TIA750), ACA distance opening (AOD750) and trabecular iris space area (TISA750). The influence of ACD and vault was examined by categorizing the sample into ACD (shallow, average and deep) and vault (low, optimal and high) groups. RESULTS: Preoperative ACA morphology varied based on ACD, with shallower ACDs exhibiting narrower TIA750, smaller AOD750 and TISA750. ICL implantation induced greater ACA narrowing more in the deep ACD group (TIA750 = 20.1 degrees; AOD750 = 0.82 mm and TISA750 = 0.44 mm2) compared to the shallow ACD group (TIA750 = 15.2 degrees; AOD750 = 0.44 mm and TISA750 = 0.21 mm2). Postoperatively, deeper ACDs showed larger ACAs. Increasing vault magnitude led to increased ACA narrowing, with the low vault group exhibiting smaller closure (TIA750 = 14.3 degrees; AOD750 = 0.56 mm and TISA750 = 0.29 mm2) compared to the high vault group (TIA750 = 20.8 degrees; AOD750 = 0.73 mm and TISA750 = 0.36 mm2). The magnitude of ACA narrowing associated with the vault had a consistent effect across different ACD groups. CONCLUSIONS: Posterior chamber intraocular lens implantation results in ACA narrowing, the extent of which is contingent upon preoperative anterior chamber and ACA morphology, with additional influence from vault magnitude.


Asunto(s)
Segmento Anterior del Ojo , Glaucoma de Ángulo Cerrado , Humanos , Implantación de Lentes Intraoculares , Estudios Retrospectivos , Presión Intraocular , Glaucoma de Ángulo Cerrado/cirugía , Cámara Anterior , Tomografía de Coherencia Óptica/métodos
19.
Clin Ophthalmol ; 18: 351-360, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38332905

RESUMEN

Purpose: Ocular parameters are not only useful for diagnosing diseases but also for guiding treatment approaches. A lot of previous studies have reported ocular parameters and its relations before cataract surgery. However, despite ethnic differences in ocular biometry, few reports have dealt with Japanese. Hence, this retrospective cross-sectional study aimed to measure parameters of preoperative cataract patients and examines the correlations between each parameter in Japanese elderly people. Patients and Methods: The 210 subjects had their ocular axial lengths measured with OA-2000. The endpoints were ocular axial length (AL), central corneal thickness (CCT), average anterior corneal radius of curvature (CR), white-to-white (WTW), anterior chamber depth (ACD), and lens thickness (LT). Our analyses utilized the eye with the longer AL in each person. Each parameter was analyzed for correlations in a round-robin manner. Regression analyses were performed on parameters correlated with AL. Results: The parameters correlated with AL were CR (r = 0.33, P < 0.0001), WTW (r = 0.29, P < 0.0001), ACD (r = 0.59, P < 0.0001), and LT (r = -0.30, P < 0.0001). These parameters related to AL in all simple regression equations (CR (P < 0.0001), WTW (P = 0.0002), ACD (P < 0.0001), LT (P = 0.0001)). In multiple regression analyses, CR, ACD, and LT might relate to AL (CR (P = 0.0002), ACD (P < 0.0001), LT (P = 0.018)). LT tended to be thinner as AL increased, while CR, WTW, and ACD tended to increase. Conclusion: This information may be useful in developing strategies for ophthalmic surgery, as it provides information on the location of intraocular tissues. Various parameters have been used in intraocular lens (IOL) power calculations in recent years and knowledge of the interrelationship among parameters may be useful in determining IOL power according to ethnicity in the future.

20.
BMC Ophthalmol ; 24(1): 87, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38408954

RESUMEN

BACKGROUND: To evaluate the difference in anterior chamber depth (ACD) between two eyes among keratoconus patients with binocular very asymmetric ectasia (VAE) and to explore the influencing factors. METHODS: The corneal curvature and ACD in both eyes of patients with VAE were measured by Sirius (version 3.2, CSO, Italy) at the following points: corneal vertex, maximum curvature (apex), and the 1.5 mm, 2.5 mm, and 3.5 mm superior-, inferior-, nasal-, temporal-paracentral from center. The mean pupil power (MPP) and corneal morphology parameters were also measured. Correlations between ACD and curvature and morphology parameters were analyzed by linear regression. RESULTS: 172 eyes of 86 patients (9 to 45 years) were classified into the VAE-N (n = 86) group and the VAE-E group (n = 86) based on the corneal morphology. The central (3.32 ± 0.27 mm versus 3.43 ± 0.29 mm, P < 0.001) and paracentral ACDs increased significantly in the VAE-E group, and the corneal morphology parameters were also significantly higher. The central ACD was significantly correlated with the MPP (r = 0.465), KVf/b (Keratoconus Vertex front/back) (r = 0.306, r = 0.327), and BCVf/b (Baiocchi Calossi Versaci front/back) (r = 0.356, r = 0.416). Linear regression showed good relationships between △ACD and △MPP (R2 = 0.429) and △KVf/b (R2 = 0.504, R2 = 0.536). CONCLUSIONS: The ACD was larger in the VAE-E group. The difference in ACD between the VAE-E and VAE-N groups was significantly correlated with corneal curvature and the extent of corneal elevation, indicating the influences of both the corneal magnification effect and corneal ectasia on ACD.


Asunto(s)
Queratocono , Humanos , Queratocono/complicaciones , Queratocono/diagnóstico , Topografía de la Córnea , Paquimetría Corneal , Dilatación Patológica , Córnea , Cámara Anterior