Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 363
Filtrar
1.
Ann Biomed Eng ; 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39294465

RESUMEN

Tissue engineering is a dynamic field focusing on the creation of advanced scaffolds for tissue and organ regeneration. These scaffolds are customized to their specific applications and are often designed to be complex, large structures to mimic tissues and organs. This study addresses the critical challenge of effectively characterizing these thick, optically opaque scaffolds that traditional imaging methods fail to fully image due to their optical limitations. We introduce a novel multi-modal imaging approach combining ultrasound, photoacoustic, and acoustic radiation force impulse imaging. This combination leverages its acoustic-based detection to overcome the limitations posed by optical imaging techniques. Ultrasound imaging is employed to monitor the scaffold structure, photoacoustic imaging is employed to monitor cell proliferation, and acoustic radiation force impulse imaging is employed to evaluate the homogeneity of scaffold stiffness. We applied this integrated imaging system to analyze melanoma cell growth within silk fibroin protein scaffolds with varying pore sizes and therefore stiffness over different cell incubation periods. Among various materials, silk fibroin was chosen for its unique combination of features including biocompatibility, tunable mechanical properties, and structural porosity which supports extensive cell proliferation. The results provide a detailed mesoscale view of the scaffolds' internal structure, including cell penetration depth and biomechanical properties. Our findings demonstrate that the developed multimodal imaging technique offers comprehensive insights into the physical and biological dynamics of tissue-engineered scaffolds. As the field of tissue engineering continues to advance, the importance of non-ionizing and non-invasive imaging systems becomes increasingly evident, and by facilitating a deeper understanding and better characterization of scaffold architectures, such imaging systems are pivotal in driving the success of future tissue-engineering solutions.

2.
Diagnostics (Basel) ; 14(11)2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38893610

RESUMEN

BACKGROUND: Non-alcoholic fatty liver disease (NAFLD) encompasses a heterogeneous spectrum ranging from simple steatosis to fibrosis and cirrhosis. Fibrosis, associated with long-term overall mortality and liver-related events, requires evaluation. Traditionally, liver biopsy has been the gold standard for diagnosing fibrosis. However, its invasive nature, potential complications, and sampling variability limit widespread use. Consequently, various non-invasive tests have been developed as alternatives for diagnosing fibrosis in NAFLD patients. AIM: This study aimed to compare the accuracy of non-invasive tests (NITs) and evaluate the diagnostic accuracy of acoustic radiation force impulse (ARFI), one of the point shear wave techniques, compared to conventional methods, assessing its effective role in diagnosis. METHODS: This is a retrospective study; a total of 136 patients diagnosed with fatty liver disease through ultrasonography were enrolled. The anthropometric data of the patients were collected on the day of admission and blood tests, measurements of ARFI, and a point shear test were conducted using abdominal ultrasound; a biopsy was performed the following day. In addition, we calculated the aspartate aminotransferase-to-platelet ratio index (APRI) index based on four factors (FIB-4) and the NAFLD fibrosis score (NFS). Subsequently, we assessed the diagnostic accuracy of NITs within various subgroups based on the extent of obesity, steatosis, or NAFLD activity score. RESULTS: ARFI has been shown to have the highest diagnostic value among various NITs, with AUROC values of 0.832, 0.794, 0.767, and 0.696 for ARFI, APRI, FIB-4, and NFS, respectively. In the morbidly obese subgroup, the AUROC values of ARFI, APRI, FIB-4, and NFS were 0.805, 0.769, 0.736, and 0.674. In the group with severe steatosis or non-alcoholic steatohepatitis (NASH), the AUROC values were 0.679, 0.596, 0.661, and 0.612, respectively, for severe steatosis and 0.789, 0.696, 0.751, and 0.691, respectively, for NASH. CONCLUSIONS: In conclusion, ARFI is not affected by various factors and maintains diagnostic accuracy compared to serum NITs. Therefore, we can recommend ARFI as a valuable diagnostic test to screen for advanced fibrosis in patients with NAFLD.

3.
Bioengineering (Basel) ; 11(6)2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38927825

RESUMEN

Agarose gels are often used as a tissue mimic. The goal of this work was to determine the appropriate agarose concentrations that result in mechanical properties that match three different porcine organs. Strain tests were carried out with an amplitude varying from 0.01% to 10% at a frequency of 1 Hz on a range of agarose concentrations and porcine organs. Frequency sweep tests were performed from 0.1 Hz to a maximum of 9.5 Hz at a shear strain amplitude of 0.1% for agarose and porcine organs. In agarose samples, the effect of pre-compression of the samples up to 10% axial strain was considered during frequency sweep tests. The experimental measurements from agarose samples were fit to a fractional order viscoelastic (springpot) model. The model was then used to predict stress relaxation in response to a step strain of 0.1%. The prediction was compared to experimental relaxation data, and the results agreed within 12%. The agarose concentrations (by mass) that gave the best fit were 0.25% for the liver, 0.3% for the kidney, and 0.4% for the heart. At a frequency of 0.1 Hz and a shear strain of 0.1%, the agarose concentrations that best matched the shear storage modulus of the porcine organs were 0.4% agarose for the heart, 0.3% agarose for the kidney, and 0.25% agarose for the liver.

4.
Ultrasound Med Biol ; 50(8): 1071-1087, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38762390

RESUMEN

The World Federation for Ultrasound in Medicine and Biology (WFUMB) endorsed the development of this document on multiparametric ultrasound. Part 1 is an update to the WFUMB Liver Elastography Guidelines Update released in 2018 and provides new evidence on the role of ultrasound elastography in chronic liver disease. The recommendations in this update were made and graded using the Oxford classification, including level of evidence (LoE), grade of recommendation (GoR) and proportion of agreement (Oxford Centre for Evidence-Based Medicine [OCEBM] 2009). The guidelines are clinically oriented, and the role of shear wave elastography in both fibrosis staging and prognostication in different etiologies of liver disease is discussed, highlighting advantages and limitations. A comprehensive section is devoted to the assessment of portal hypertension, with specific recommendations for the interpretation of liver and spleen stiffness measurements in this setting.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hepatopatías , Hígado , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Hepatopatías/diagnóstico por imagen , Hígado/diagnóstico por imagen , Guías de Práctica Clínica como Asunto
5.
Clin Ter ; 175(3): 137-145, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38767070

RESUMEN

Background: Various non-invasive methods have been studied for assessing the fibrosis stage in patients with chronic hepatitis B. However, the performance of APGA, Fibrosis index in diagnosing liver fibrosis remains unclear globally and specifically in Vietnam. Methods: An analytical cross-sectional study was performed among 242 patients treated at Thong Nhat Hospital. Results: Both the APGA index and Fibrosis index showed good accuracy in diagnosing significant fibrosis (≥ F2), advanced liver fibro-sis (≥ F3), and cirrhosis (F4) with an area under the curve (AUROC) greater than 0.7. AUROC value of APGA index, Fibrosis index for diagnosing signifcant fibrosis (≥ F2) were 0.828, 0.767 respectively. AUROC value of APGA index, Fibrosis index for diagnosing advanced liver fibrosis (≥ F3) were 0.784, 0.755 respectively. AUROC value of APGA index, Fibrosis index for diagnosing cirrhosis (F4) were 0.736, 0.782 respectively. APGA index and the Fibrosis index were significantly positively correlated with the fibrosis stage (p < 0.001), with the APGA index showing the strongest correlation (r = 0.51, p < 0.001). Conclusions: The APGA values of 6.23, 7.88, and 8.99 can serve as cutoff points for the diagnosis of significant fibrosis (≥F2), advanced fibrosis (≥F3), and cirrhosis (F4) when combined with ARFI data.


Asunto(s)
Hepatitis B Crónica , Cirrosis Hepática , Humanos , Cirrosis Hepática/diagnóstico , Cirrosis Hepática/patología , Estudios Transversales , Hepatitis B Crónica/complicaciones , Hepatitis B Crónica/patología , Femenino , Masculino , Adulto , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Vietnam
6.
Sensors (Basel) ; 24(9)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38732804

RESUMEN

In general, it is difficult to visualize internal ocular structure and detect a lesion such as a cataract or glaucoma using the current ultrasound brightness-mode (B-mode) imaging. This is because the internal structure of the eye is rich in moisture, resulting in a lack of contrast between tissues in the B-mode image, and the penetration depth is low due to the attenuation of the ultrasound wave. In this study, the entire internal ocular structure of a bovine eye was visualized in an ex vivo environment using the compound acoustic radiation force impulse (CARFI) imaging scheme based on the phase-inverted ultrasound transducer (PIUT). In the proposed method, the aperture of the PIUT is divided into four sections, and the PIUT is driven by the out-of-phase input signal capable of generating split-focusing at the same time. Subsequently, the compound imaging technique was employed to increase signal-to-noise ratio (SNR) and to reduce displacement error. The experimental results demonstrated that the proposed technique could provide an acoustic radiation force impulse (ARFI) image of the bovine eye with a broader depth-of-field (DOF) and about 80% increased SNR compared to the conventional ARFI image obtained using the in-phase input signal. Therefore, the proposed technique can be one of the useful techniques capable of providing the image of the entire ocular structure to diagnose various eye diseases.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Ojo , Relación Señal-Ruido , Transductores , Animales , Bovinos , Ojo/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Ultrasonografía/métodos
7.
BMC Med Imaging ; 24(1): 90, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627672

RESUMEN

BACKGROUND: Wilson's disease (WD) often leads to liver fibrosis and cirrhosis, and early diagnosis of WD cirrhosis is essential. Currently, there are few non-invasive prediction models for WD cirrhosis. The purpose of this study is to non-invasively predict the occurrence risk of compensated WD cirrhosis based on ultrasound imaging features and clinical characteristics. METHODS: A retrospective analysis of the clinical characteristics and ultrasound examination data of 102 WD patients from November 2018 to November 2020 was conducted. According to the staging system for WD liver involvement, the patients were divided into a cirrhosis group (n = 43) and a non-cirrhosis group (n = 59). Multivariable logistic regression analysis was used to identify independent influencing factors for WD cirrhosis. A nomogram for predicting WD cirrhosis was constructed using R analysis software, and validation of the model's discrimination, calibration, and clinical applicability was completed. Due to the low incidence of WD and the small sample size, bootstrap internal sampling with 500 iterations was adopted for validation to prevent overfitting of the model. RESULTS: Acoustic Radiation Force Impulse (ARFI), portal vein diameter (PVD), and serum albumin (ALB) are independent factors affecting WD cirrhosis. A nomogram for WD cirrhosis was constructed based on these factors. The area under the ROC curve (AUC) of the model's predictive ability is 0.927 (95% CI: 0.88-0.978). As demonstrated by 500 Bootstrap internal sampling validations, the model has high discrimination and calibration. Clinical decision curve analysis shows that the model has high clinical practical value. ROC curve analysis of the model's rationality indicates that the model's AUC is greater than the AUC of using ALB, ARFI, and PVD alone. CONCLUSION: The nomogram model constructed based on ARFI, PVD, and ALB can serve as a non-invasive tool to effectively predict the risk of developing WD cirrhosis.


Asunto(s)
Degeneración Hepatolenticular , Humanos , Degeneración Hepatolenticular/diagnóstico por imagen , Degeneración Hepatolenticular/complicaciones , Nomogramas , Estudios Retrospectivos , Cirrosis Hepática/diagnóstico por imagen , Curva ROC
8.
Laryngoscope Investig Otolaryngol ; 9(2): e1249, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38651078

RESUMEN

Objectives: To provide a comprehensive summary of the different modalities available to measure soft tissue fibrosis after radiotherapy in head and neck cancer patients. Data Sources: PubMed, Scopus, and Web of Sciences. Review Methods: A search was conducted using a list of medical subject headings and terms related to head and neck oncology, radiation fibrosis, and quantitative measurements, including bioimpedance, MRI, and ultrasound. Original research related to quantitative measurement of neck fibrosis post-radiotherapy was included without time constraints, while reviews, case reports, non-English texts, and inaccessible studies were excluded. Discrepancies during the review were resolved by discussing with the senior author until consensus was reached. Results: A total of 284 articles were identified and underwent title and abstract screening. Seventeen articles had met our criteria for full-text review based on relevance, of which nine had met our inclusion criteria. Young's modulus (YM) and viscoelasticity measures have demonstrated efficacy in quantifying neck fibrosis, with fibrotic tissues displaying significantly higher YM values and altered viscoelastic properties such as increased stiffness rate-sensitivity and prolonged stress-relaxation post-radiation. Intravoxel incoherent motion offers detailed insights into tissue changes by assessing the diffusion of water molecules and blood perfusion, thereby differentiating fibrosed from healthy tissues. Shear wave elastography has proven to be an effective technique for quantifying radiation-induced fibrosis in the head and neck region by measuring shear wave velocity. Conclusion: There are various modalities to measure radiation-induced fibrosis, each with its unique strengths and limitations. Providers should be aware of these implications and decide on methodologies based on their specific clinical workflow. Level of Evidence: Step 5.

9.
United European Gastroenterol J ; 12(6): 667-677, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38363191

RESUMEN

BACKGROUND: Transcutaneous point-shear wave elastography (p-SWE) performed using an acoustic radiation force impulse can be used to quantify pancreatic stiffness in chronic pancreatitis (CP). We aimed to evaluate its usefulness to diagnose and monitor CP. METHODS: 175 participants were included in this prospective study including patients with CP (n = 65), liver cirrhosis (LC; n = 60), alcohol abuse (n = 10) and healthy controls (n = 40). Point-shear wave elastography of the pancreas was performed and quantified as median shear wave velocity (SWV). In the same way, p-SWE of the spleen served as a marker of portal hypertension. The M-ANNHEIM Severity score was used as global marker for disease activity in CP. RESULTS: Compared to healthy controls, pancreatic SWV was significantly elevated in CP (1.38 vs. 0.96 m/s; p < 0.0001, MWU-test). Pancreatic SWV was increased in alcoholic CP but not in hereditary CP. Receiver operating characteristic analysis revealed 1.2 m/s as the optimal cut-off to identify non-heredity-CP subjects (90% specificity; 81% sensitivity; 92% positive predictive value). Pancreatic SWV correlated significantly with the M-ANNHEIM Severity score, severity of CP-typical complications (both p < 0.05, linear regression analysis), morphological changes of the pancreas and need for hospital treatment (both p < 0.05, MWU-test) but not with exocrine or endocrine insufficiency. Pancreatic SWV >1.7 m/s was identified to predict M-ANNHEIM Severity score ≥11 points. Pancreatic SWV was also elevated in LC (1.42 m/s; p < 0.001), correlating with increased splenic SWV. CONCLUSION: Transcutaneous pancreatic p-SWE represents a bedside, cost-effective and non-invasive tool which adds valuable information to the process of diagnosing and monitoring CP. By portal hypertension, an increased pancreatic SWV must be expected.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Páncreas , Pancreatitis Crónica , Curva ROC , Índice de Severidad de la Enfermedad , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Pancreatitis Crónica/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Femenino , Estudios Prospectivos , Adulto , Páncreas/diagnóstico por imagen , Páncreas/patología , Anciano , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/complicaciones , Estudios de Casos y Controles , Sensibilidad y Especificidad , Valor Predictivo de las Pruebas , Hipertensión Portal/diagnóstico por imagen , Hipertensión Portal/etiología , Hipertensión Portal/diagnóstico , Bazo/diagnóstico por imagen , Bazo/patología
10.
J Endocrinol Invest ; 47(7): 1679-1689, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38280162

RESUMEN

PURPOSE: Asymptomatic primary hyperparathyroidism (aPHPT) has been recognized as a condition that can lead to renal complications. Timely identification of prognostic indicators for renal impairment holds the potential to facilitate proactive monitoring and treatment strategies in these patients. This study aims to investigate the utility of acoustic radiation force impulse (ARFI) imaging and renal resistive index (RRI), in identifying renal parenchymal and vascular changes in patients with aPHPT. METHODS: Forty-two patients with aPHPT and 42 controls matched for age, sex, and body mass index were included in the study. The presence of renovascular changes was evaluated by RRI measurement with Doppler ultrasonography, and the presence of renal parenchymal involvement was evaluated by ARFI quantification, given as shear wave velocity (SWV). RESULTS: In aPHPT patients, both the mean RRI and mean SWV values exhibited substantial elevation compared to the control group (P < 0.001 for both). Significant associations were observed between SWV values and serum calcium, parathyroid hormone (PTH), and adenoma size within the patient group (P < 0.001, P < 0.001, P = 0.016, respectively). Similarly, the mean RRI demonstrated positive correlations with serum calcium and PTH levels in the patient group (P< 0.001, P = 0.011, respectively). Multivariate linear regression analysis underscored the connection between mean RRI and mean SWV values with serum calcium levels within the patient group. In addition, serum PTH levels affected mean SWV positively and significantly. CONCLUSION: The use of ARFI imaging and RRI measurements appears to hold potential in identifying renal involvement in patients with aPHPT.


Asunto(s)
Hiperparatiroidismo Primario , Humanos , Femenino , Masculino , Hiperparatiroidismo Primario/diagnóstico por imagen , Hiperparatiroidismo Primario/complicaciones , Persona de Mediana Edad , Pronóstico , Estudios de Casos y Controles , Diagnóstico por Imagen de Elasticidad/métodos , Riñón/diagnóstico por imagen , Riñón/patología , Ultrasonografía Doppler/métodos , Adulto , Anciano , Hormona Paratiroidea/sangre , Enfermedades Asintomáticas , Enfermedades Renales/etiología , Enfermedades Renales/diagnóstico por imagen , Enfermedades Renales/diagnóstico
11.
J Biomech ; 163: 111955, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38266533

RESUMEN

Breast implants are widely used after breast cancer resection and must be changed regularly to avoid a rupture. To date, there are no quantitative criteria to help this decision. The mechanical evolution of the gels and membranes of the implants is still underinvestigated, although it can lead to early rupture. In this study, 35 breast explants having been implanted in patients for up to 17 years were characterized by ex vivo measurements of their mechanical properties. Using Acoustic Radiation Force Impulse (ARFI) ultrasound elastography, an imaging method for non-destructive mechanical characterization, an increase in the stiffness of the explants has been observed. This increase was correlated with the implantation duration, primarily after 8 years of implantation. With an increase of the shear modulus of up to a factor of nearly 3, the loss of flexibility of the implants is likely to lead to a significant increase of their risk of rupture. A complementary analysis of the gel from the explants by mass spectrometry imaging (MSI) and liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS) confirms the presence of metabolites of cholesterol originating from the breast tissues, which most likely crossed the membrane of the implants and most likely degrades the gel. By observing the consequences of the physical-chemical mechanisms at work within patients, this study shows that ultrasound elastography could be used in vivoas a quantitative indicator of the risk of breast implant rupture and help diagnose their replacement.


Asunto(s)
Implantes de Mama , Neoplasias de la Mama , Diagnóstico por Imagen de Elasticidad , Humanos , Femenino , Diagnóstico por Imagen de Elasticidad/métodos , Implantes de Mama/efectos adversos , Ultrasonido
12.
Orphanet J Rare Dis ; 19(1): 6, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38172891

RESUMEN

BACKGROUND: Extracorporeal shock wave therapy (ESWT) is reportedly effective for improving spasticity and motor function in children with cerebral palsy (CP). Because late-stage Rett syndrome has a similar presentation, this study aimed to investigate the effects of ESWT on these two diseases. MATERIAL AND METHODS: Patients diagnosed with spastic CP and Rett syndrome received 1500 impulses of ESWT at 4 Hz and 0.1 mJ/mm2, on their spastic legsonce weekly for a total of 12 weeks. Outcomes were assessed before and 4 and 12 weeks after ESWT. Clinical assessments included the Modified Ashworth Scale (MAS), passive range of motion (PROM), and Gross Motor Function Measure 88 (GMFM-88). Ultrasonographic assessments included muscle thickness, acoustic radiation force impulse (ARFI), and strain elastography. RESULTS: Fifteen patients with CP and six with Rett syndrome were enrolled in this study. After ESWT, patients with CP showed significant clinical improvement in the MAS (P = 0.011), ankle PROM (P = 0.002), walking/running/jumping function (P = 0.003), and total function (P < 0.001) of the GMFM-88. The patients with Rett syndrome showed improved MAS scores (P = 0.061) and significantly improved total gross motor function (P = 0.030). Under ARFI, patients with CP demonstrated decreased shear wave speed in the gastrocnemius medial head (P = 0.038). Conversely, patients with Rett syndrome show increased shear-wave speeds after ESWT. CONCLUSION: Our study provides evidence that a weekly course of low-dose ESWT for 12 weeks is beneficial for children with both CP and Rett syndrome, with the clinical effects of reducing spasticity and improving the gross motor function of the lower limbs. The ARFI sonoelastography reveals improvement of muscle stiffness in patients with CP after ESWT, but deteriorated in patients with Rett syndrome. The diverse therapeutic response to ESWT may be caused by the MECP2 mutation in Rett syndrome, having a continuous impact and driving the pathophysiology differently as compared to CP, which is secondary to a static insult. Trial registration IRB 201700462A3. Registered 22March 2017, https://cghhrpms.cgmh.org.tw/HRPMS/Default.aspx .


Asunto(s)
Parálisis Cerebral , Tratamiento con Ondas de Choque Extracorpóreas , Síndrome de Rett , Niño , Humanos , Espasticidad Muscular/terapia , Síndrome de Rett/diagnóstico por imagen , Síndrome de Rett/terapia , Parálisis Cerebral/diagnóstico por imagen , Parálisis Cerebral/terapia , Parálisis Cerebral/complicaciones , Tratamiento con Ondas de Choque Extracorpóreas/efectos adversos , Músculo Esquelético
13.
Hepatobiliary Pancreat Dis Int ; 23(1): 20-24, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37468349

RESUMEN

BACKGROUND: Porto-sinusoidal vascular disease (PSVD) and portal vein thrombosis (PVT) are causes of portal hypertension characterized respectively by an intrahepatic and a pre-hepatic obstacle to the flow in the portal system. As PVT may be a consequence of PSVD, in PVT patients at presentation, a pre-existing PSVD should be suspected. In these patients the identification of an underlying PSVD would have relevant implication regarding follow-up and therapeutic management, but it could be challenging. In this setting ultrasonography may be valuable in differential diagnosis. The aim of the study was to use ultrasonography to identify parameters to discriminate between PSVD and "pure" PVT and then to suspect PVT secondary to a pre-existing PSVD. METHODS: Fifty-three patients with histologically proven PSVD and forty-eight patients affected by chronic PVT were enrolled and submitted to abdominal ultrasonography with elastography by acoustic radiation force impulse (ARFI). RESULTS: ARFI was higher and superior mesenteric vein (SMV) diameter was wider in PSVD patients than in PVT patients. Thus, a prognostic score was obtained as linear combinations of the two parameters with a good discrimination capacity between PSVD and PVT (the area under the curve = 0.780; 95% confidence interval: 0.690-0.869). CONCLUSIONS: A score based on ARFI and SMV diameter may be useful to suspect an underlying PSVD in patients with PVT and to identify a subgroup of patients to be submitted to liver biopsy.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hipertensión Portal Idiopática no Cirrótica , Trombosis de la Vena , Humanos , Vena Porta/patología , Cirrosis Hepática/patología , Factores de Riesgo , Trombosis de la Vena/diagnóstico por imagen , Ultrasonografía
14.
Skeletal Radiol ; 53(3): 547-554, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37698625

RESUMEN

OBJECTIVE: To explore the role of shear wave elastography of the tibial nerve as a potential ultrasonographic method for the diagnosis of tibial neuropathy in patients with type 2 diabetes. MATERIALS AND METHODS: This cross-sectional study included 50 subjects each in case (patients with diabetic tibial neuropathy diagnosed on the basis of clinical features and nerve conduction study) and control groups (non-diabetic non-neuropathic healthy volunteers). The exclusion criteria included the presence of type 1 diabetes, a known history of neuropathy from other causes except for type 2 diabetes, or a history of leg or ankle fracture. Cross-sectional area and shear wave velocity values of the tibial nerve were measured in both groups. Demographic details and body mass index were obtained in both groups and additionally, the duration of type 2 diabetes and HbA1c values in the case group were also noted. Wilcoxon Mann-Whitney U test was used to compare these variables in study groups. ROC curve analysis provided additional findings. RESULTS: Tibial nerve stiffness was significantly higher in the case group (p-value < 0.001). The study groups did not significantly differ in the Cross-sectional area of the tibial nerve (p-value 0.57). The case group exhibited a higher frequency of loss of the fascicular pattern of the tibial nerve (40% vs 18%, p-value 0.027). Duration of diabetes mellitus and HbA1c values did not significantly affect Shear wave velocity values in the case group. At the cut-off value of Shear wave velocity of 3.13 m/s, sensitivity and specificity to diagnose diabetic peripheral neuropathy were 94% and 88% respectively. CONCLUSION: Increased nerve stiffness is seen in patients with diabetic peripheral neuropathy. Shear wave elastography might prove as a novel noninvasive technology for screening/early diagnosis of diabetic peripheral neuropathy.


Asunto(s)
Diabetes Mellitus Tipo 2 , Neuropatías Diabéticas , Diagnóstico por Imagen de Elasticidad , Neuropatía Tibial , Humanos , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Estudios Transversales , Neuropatías Diabéticas/diagnóstico por imagen , Hemoglobina Glucada , Nervio Tibial/diagnóstico por imagen , Neuropatía Tibial/complicaciones
15.
Skeletal Radiol ; 53(6): 1111-1118, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38057435

RESUMEN

OBJECTIVE: To investigate and quantify age-related changes in lower limb muscle stiffness in typically developing children and adolescents using acoustic radiation force impulse shear wave elastography. MATERIALS AND METHODS: Shear wave velocities of bilateral rectus femoris, tibialis anterior, and medial gastrocnemius muscles at rest were obtained in typically developing children and adolescents aged 3 to 18 years. The participants were classified into three age groups: Group 1 (children), 3 to 7 years old; Group 2, 8 to 12 (pre-adolescent); and Group 3 (adolescent), 13 to 18. The shear wave velocities of muscle were compared across the three age groups, as well as compared between right- and left-side limbs. The correlation between shear wave velocities and body weight or body mass index was assessed. RESULTS: Of the 47 participants, 21 were in Group 1, 17 in Group 2, and 9 in Group 3. There were no significant differences among the three age groups' shear wave velocities of bilateral lower limb muscles, and no significant differences between right and left sides. There was no correlation between muscle stiffness and body weight or body mass index. CONCLUSION: The present pilot study applied acoustic radiation force impulse shear wave elastography to quantify lower limb muscle stiffness in typically developing children and adolescents aged 3 to 18 years, suggesting no marked change in muscle stiffness occurs as they develop.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Niño , Humanos , Adolescente , Preescolar , Proyectos Piloto , Músculo Esquelético/diagnóstico por imagen , Extremidad Inferior/diagnóstico por imagen , Peso Corporal , Acústica
16.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1018422

RESUMEN

Objective To assess the clinical effect of the Yiqi Huoxue Huazhuo therapy(the therapy for replenishing qi,activating blood and resolving turbidity)for the treatment of hepatic fibrosis in Wilson's disease(WD,also known as hepatolenticular degeneration).Methods Using retrospective research method,52 patients with liver fibrosis in WD of qi deficiency and blood stasis type were divided into 24 cases in the control group and 28 cases in the treatment group according to the treatment method.The control group was treated with conventional decopper therapy with western medicines,and the treatment group was treated with Chinese herbal decoction based on Yiqi Huoxue Huazhuo therapy together with conventional decopper therapy.Both groups were treated for a total of 4 weeks.Before and after the treatment,the two groups were observed in the changes of traditional Chinese medicine(TCM)syndrome scores,Unified Wilson's Disease Rating Scale(UWDRS)hepatic symptom scores,serum levels of liver fibrosis indicators of pre-collagen typeⅢ(PCⅢ),hyaluronic acid(HA),collagenⅣ(CⅣ),and laminin(LN),C-X-C motif chemokine ligand 10(CXCL10)level,and the point shear-wave elastography(pSWE)values of hepatic ultrasound based on acoustic radiation force impulse imaging(ARFI).After treatment,the clinical efficacy of the two groups was evaluated.Results(1)After 4 weeks of treatment,the total effective rate of the treatment group was 85.71%(24/28),while that of the control group was 54.17%(13/24),and the intergroup comparison(tested by chi-square test)showed that the therapeutic efficacy of the treatment group was significantly superior to that of the control group(P<0.05).(2)After treatment,the TCM syndrome scores in both groups were decreased compared with those before treatment(P<0.01),and the decrease of TCM syndrome scores in the treatment group was significantly superior to that in the control group(P<0.05).(3)After treatment,the UWDRS liver symptom scores in the two groups were decreased compared with those before treatment(P<0.01),but the difference was not statistically significant when comparing between the two groups after treatment(P>0.05).(4)After treatment,serum levels of liver fibrosis indicators of HA,LN,CⅣ and PCⅢ in the treatment group were all decreased compared with those before treatment(P<0.01),while in the control group only serum LN and PCⅢlevels were decreased(P<0.05).The intergroup comparison showed that the decrease of serum HA,LN,and PCⅢlevels in the treatment group was superior to that in the control group(P<0.05 or P<0.01),while the decrease of serum CⅣlevel tended to be superior to that in the control group,but the difference was not statistically significant(P>0.05).(5)After treatment,the serum chemokine CXCL10 level in the treatment group was significantly decreased compared with that before treatment(P<0.01),while the level tended to decrease in the control group,but the difference was not statistically significant(P>0.05).The intergroup comparison showed that the reduction of serum CXCL10 level in the treatment group was significantly superior to that in the control group(P<0.05).(6)After treatment,the pSWE values of hepatic ultrasound in the two groups were lower than those before treatment(P<0.01),and the reduction of pSWE values in treatment group was significantly superior to that of the control group(P<0.01).Conclusion Yiqi Huoxue Huazhuo therapy can effectively reduce the TCM syndrome scores of WD patients,improve the UWDRS hepatic symptom scores,down-regulate the liver fibrosis indicator level and serum CXCL10 expression level,reduce the pSWE values of hepatic ultrasound,and enhance the clinical efficacy.

17.
Eur Radiol ; 2023 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-38091056

RESUMEN

OBJECTIVES: To evaluate the role of shear-wave dispersion slope for predicting renal allograft dysfunction. METHODS: We retrospectively reviewed 128 kidney transplant recipients (median age, 55 years [interquartile range, 43-62 years]; male, 68) who underwent biopsy for allograft evaluation from November 2022 to February 2023. Cortex and renal sinus fat stiffness and shear-wave dispersion slope were obtained at shear-wave elastography (SWE). Cortex-to-sinus stiffness ratio (SR) and dispersion slope ratio (DSR)-related clinical and pathologic factors were evaluated using multivariable linear regression analysis. We conducted univariate and multivariate analyses for multiparametric ultrasound (US) parameters for identifying acute rejection and calculated the area under the receiver operating curve (AUC) values. RESULTS: Of 128 patients, 31 (24.2%) demonstrated acute rejection. The SR value did not differ between patient groups (1.21 vs. 1.20, p = 0.47). Patients with acute rejection demonstrated a higher DSR than those without rejection (1.4 vs. 1.21, p < 0.01). Interstitial fibrosis and tubular atrophy grade (IFTA; coefficient, 0.11/grade; p = 0.04) and renal transplant and biopsy interval (coefficient, 0.00007/day; p = 0.03) were SR determinant factors, whereas only IFTA grade (coefficient, 0.10/grade; p = 0.01) for DSR. Multivariate analysis revealed mean resistive index (odds ratio [OR] 1.08, 95% confidence interval [CI] 1.02-1.14, p = 0.01) and DSR value (OR 16.0, 95% CI 3.0-85.8, p = 0.001) as independent factors for predicting acute rejection. An AUC of 0.74 for detecting acute rejection was achieved by combining the resistive index and DSR value. CONCLUSION: Shear-wave dispersion slope obtained at SWE may help identify renal allograft dysfunction. CLINICAL RELEVANCE STATEMENT: Acute rejection in renal allografts is a major cause of allograft failure, but noninvasive diagnosis is a challenge. Shear-wave dispersion slope can identify acute rejection non-invasively. KEY POINTS: • The interstitial fibrosis and tubular atrophy grade was a determinant factor for stiffness ratio and shear-wave dispersion slope ratio between cortex and renal sinus fat. • Shear-wave dispersion slope ratio between cortex and renal sinus fat could identify acute rejection in renal allografts. • A shear-wave dispersion slope has a potential to reduce unnecessary renal biopsy for evaluating renal allografts.

18.
Artículo en Inglés | MEDLINE | ID: mdl-37930496

RESUMEN

BACKGROUND: In routine clinical practice, assessment of portal hypertension (PHT) among patients with liver cirrhosis is done by a upper gastrointestinal endoscopy (UGIE); however, its invasive nature limits its use. Recent advances in ultrasound imaging make it possible to evaluate the tissue stiffness of the liver and spleen reflecting the severity of underlying fibrosis. Liver stiffness and spleen stiffness can be used to predict the presence of esophageal varices/PHT among cirrhotic patients. AIM: To predict the presence or absence of esophageal varices by measuring the stiffness of the liver and spleen by ultrasonography (USG)-based acoustic radiation force impulse (ARFI). METHODS: This cross-sectional study included 90 subjects with liver cirrhosis. Liver and splenic stiffness were measured along with the USG abdomen, UGIE and aspartate aminotransferase to platelet ratio index (APRI). RESULTS: Liver and spleen stiffness were significantly higher in cirrhotic patients compared to chronic hepatitis B. The best cut-off value of liver stiffness (LS) obtained by the receiver operating characteristic (ROC) curve was 2.16 m/s for predicting esophageal varices (AUROC 0.78, p 0.0002). The best cut-off value of splenic stiffness (SS) obtained by the ROC curve was 3.04 m/s for predicting esophageal varices (AUROC 0.698, p 0.0274). When both LS and SS were taken together, the accuracy in predicting esophageal varices increased to 92.22%. An equation to predict "esophageal varices = (0.225 LS + 0.377SS) - 0.555" was derived. CONCLUSION: LS and SS values of ≥ 2.16 m/s and 3.04 m/s, respectively, predict esophageal varices independently; however, combined assessment is better with 92% accuracy.

19.
BMC Vet Res ; 19(1): 181, 2023 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-37784120

RESUMEN

BACKGROUND: Canine hip dysplasia is a common orthopedic disease in veterinary practice. The diagnosis is made by radiographic examinations that evaluate bone alterations associated with hip dysplasia. Although radiographic examination is the gold standard for diagnosis, it does not allow a detailed evaluation of soft tissues such as the joint capsule and periarticular muscles. This study aimed to evaluate the accuracy of B-mode ultrasonography and acoustic radiation force impulse (ARFI) elastography in assessing the joint capsule and periarticular muscles of dogs using the Orthopedic Foundation of Animals (OFA) classification and the distraction index (DI) in the early and late diagnosis of hip dysplasia. This study sought to propose a protocol for the ultrasonographic evaluation of the structures involved in canine hip dysplasia. METHODS: Radiographic and ultrasonographic evaluations were performed on 108 hip joints of 54 dogs. Thirty dogs were older than 2 years and 24 were aged between 4 and 10 months. RESULTS: It was verified that an increase in pectineus muscle stiffness (cutoff value > 2.77 m/s) by elastography in some dysplastic dogs and an increase in the thickness of the joint capsule (cutoff value > 0.9 mm) in B-mode ultrasonography, were associated with a distraction index > 0.5, with both having a positive correlation. In B-mode ultrasonographic evaluation, the presence of signs of degenerative joint disease, such as irregularities of the cranial edge of the acetabulum and femoral head, were associated with a distraction index > 0.5 in canines, with a specificity of 94%. In adult dogs, the findings of degenerative joint disease on ultrasound were associated with a diseased OFA classification (P < 0.05). Measurement of the joint capsule > 1.10 mm was diagnostic for dysplasia in unhealthy dogs by OFA. CONCLUSIONS: ARFI elastography has shown that the pectineus muscle may experience changes in stiffness in dysplastic animals. Additionally, changes in joint capsule thickness can be identified in B-mode in young and adult dogs with dysplastic joints, which contributes to the diagnosis of hip dysplasia.


Asunto(s)
Enfermedades de los Perros , Diagnóstico por Imagen de Elasticidad , Luxación de la Cadera , Displasia Pélvica Canina , Animales , Perros , Displasia Pélvica Canina/diagnóstico por imagen , Displasia Pélvica Canina/complicaciones , Diagnóstico por Imagen de Elasticidad/veterinaria , Luxación de la Cadera/complicaciones , Luxación de la Cadera/veterinaria , Articulación de la Cadera/diagnóstico por imagen , Ultrasonografía/veterinaria , Enfermedades de los Perros/diagnóstico por imagen
20.
J Med Ultrasound ; 31(2): 137-143, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37576417

RESUMEN

Background: Laparoscopic cholecystectomy (LC) is the treatment of choice for cholelithiasis; however, there are procedural difficulties in determining preoperative detection of a difficult LC. The current methods using clinical and sonographic variables to identify difficult LCs have limitations to identify gallbladder adhesions which form the most common cause. We present a new method of evaluation using acoustic radiation force impulse (ARFI)-based virtual touch imaging (VTI) for the detection and classification of these patients. Methods: Fifty consecutive patients of cholelithiasis were evaluated preoperatively using conventional scoring system (CSS) and by new adhesion detection and staging (ADS) system, and patients were classified into three classes (I-III) with class I being easy, II and III being moderate-to-high difficulty LCs. Peroperative classification was done based on the difficulty level during surgery after visualization of gallbladder adhesions. The sensitivity, specificity, and area under the curves (AUCs) of both systems were compared. Results: Out of 50 patients, 72% and 54% of patients were in class I by CSS and ADS classification, while 28% and 46% were in class II and III, respectively, and were labeled as difficult LC cases; differences being two classifications were statistically significant (P = 0.02). Sensitivity, specificity, negative predictive value, and accuracy for ADS were 91%, 100%, 93.1%, and 96.0%, and for CSS, 60.9%, 100%, 75%, and 82% with AUCs of 1.0 and 0.63, respectively. Conclusion: ARFI-based VTI accurately detects gallbladder adhesions and can determine the difficult cases of LCs preoperatively using ADS classification and shows higher accuracy than CSS classification, which results in lower operative time and risk of complications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA