Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Clin Med ; 13(2)2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38256601

RESUMEN

OBJECTIVE: Direct anterior approach total hip replacement (DAA-THR) is gaining increased interest due to its tissue-sparing nature and rapid recovery. Obesity has been shown to be a significant parameter influencing cup positioning in DAA-THR. It was the intention of this retrospective study to examine how obesity would influence the restoration of native hip biomechanical parameters during DAA-THR. MATERIALS AND METHODS: A total of 74 patients from a high-volume university orthopedic center after unilateral DAA-THA were included. Patients were retrospectively allocated to a study group (BMI > 30 kg/m2) and a control group (BMI < 30 kg/m2). Furthermore, propensity-score matching for baseline parameters was performed, leaving 30 patients in each group. Biomechanical parameters of the hip (i.e., femoral offset (FO), abductor lever arm (ABL), acetabular offset (AO), center of rotation (COR), stem alignment (SA), body weight lever arm (BWL), cup inclination (CI), and leg length discrepancy (LLD) were evaluated on standardized plain radiographs, and parameters were compared to the native contralateral hip. RESULTS: Mean BMI in the study group was 35.07 ± 5.13 kg/m2 and 25.43 ± 2.64 kg/m2 in the control group. There was a significant decrease of the ABL only in the study cohort (p = 0.01). CI and SA did not differ between both cohorts. FO was slightly increased compared to the native hip in both groups. There was a marginally higher but non-significant proportion of improper FO restoration in the study group (19 vs. 16 patients, p = 0.60). CONCLUSIONS: Obesity, as quantified by BMI, only has a limited impact on the adequate reconstruction of native biomechanical parameters of the hip during DAA-THR. ABL was the only parameter to be significantly decreased in the overweight patients after DAA-THR. Therefore, special care should be taken on proper acetabular reaming and consequent seating of the cup in the obese patient to avoid excessive lateral positioning.

2.
Hip Pelvis ; 35(2): 108-121, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37323544

RESUMEN

Purpose: The primary objective of the current study is to demonstrate the trochanteric wiring technique. A secondary objective is to evaluate the clinico-radiological outcomes of use of the wiring technique during primary arthroplasty for treatment of unstable and failed intertrochanteric fractures. Materials and Methods: A prospective study including follow-up of 127 patients with unstable and failed intertrochanteric fractures who underwent primary hip arthroplasty using novel multi-planar trochanteric wiring was conducted. The average follow-up period was 17.8±4.7 months. Clinical assessment was performed using the Harris hip score (HHS). Radiographic evaluation was performed for assessment of union of the trochanter and any mechanical failure. P<0.05 was considered statistically significant. Results: At the latest follow-up, the mean HHS showed significant improvement from 79.9±1.8 (at three months) to 91.6±5.1 (P<0.05). In addition, no significant difference in the HHS was observed between male and female patients (P=0.29) and between fresh and failed intertrochanteric fractures (P=0.08). Union was achieved in all cases of fractured trochanter, except one. Wire breakage was observed in three patients. There were five cases of limb length discrepancy, three cases of lurch, and three cases of wire-related bursitis. There were no cases of dislocation or infection. Radiographs showed stable prosthesis in situ with no evidence of subsidence. Conclusion: Use of the proposed wiring technique was helpful in restoring the abductor level arm and multi-planar stability, which enabled better rehabilitation and resulted in excellent clinical and radiological outcomes with minimal risk of mechanical failure.

3.
Arch Orthop Trauma Surg ; 142(12): 3995-4005, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34821944

RESUMEN

BACKGROUND: Dislocation is a complicated process and associated with multivariate etiology and risk factors. The purpose of this study was to verify if radiologic restoration inaccuracy increases postoperative dislocation in primary total hip arthroplasty (THA) individually or synergistically. METHODS: From 2017 to 2020, we identified 76 (1.9%) patients who suffered postoperative dislocations from 3926 THAs in our institution. After excluded patients with previously proven patient-related and implant-related risk factors, the remaining patients were used to match a 1:1 control patients who were without dislocation. The cup position (inclination and anteversion angles), hip offset (HO), leg length discrepancy (LLD), and abductor lever arm (ALA) were analyzed by univariate analyses and multivariate logistic regressions. RESULTS: Measurements on radiographs showed excellent interobserver agreement (intraclass correlation coefficient (ICC) 0.922-0.952) and intraobserver agreements (ICC 0.933-0.967). HO restoration inaccuracy (without ± 5 mm) was associated with higher dislocation risk (OR 4.241 95% CI 1.440-12.492, P = 0.009). The restoration inaccuracy of the cup position, LLD, or ALA could not increase the dislocation risk individually. When combining the radiologic restoration inaccuracy factors, the HO + LLD restoration inaccuracy and HO + ALA restoration inaccuracy increased the odds of postoperative dislocation (OR 12.056, 95% CI 1.409-103.127, P = 0.023; OR 4.770, 95% CI 1.336-17.028, P = 0.016, respectively). Combining the four risk factors of cup safe zone, HO, LLD, and ALA, patients with 3 or 4 radiologic restoration inaccuracy factors showed a higher risk of dislocation (OR 13.500, 95% CI 1.340-135.983, P = 0.027). CONCLUSION: Hip offset (HO) restoration inaccuracy increased the risk of dislocation following primary THA. Multivariate radiologic restoration accuracy is critical for the prevention of dislocation and needs to be valued by surgeons.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Luxaciones Articulares , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Estudios Retrospectivos , Luxación de la Cadera/diagnóstico por imagen , Luxación de la Cadera/epidemiología , Luxación de la Cadera/etiología , Puntaje de Propensión , Diferencia de Longitud de las Piernas/diagnóstico por imagen , Diferencia de Longitud de las Piernas/epidemiología , Diferencia de Longitud de las Piernas/etiología , Luxaciones Articulares/diagnóstico por imagen , Luxaciones Articulares/epidemiología , Luxaciones Articulares/etiología , Acetábulo/cirugía
4.
J Orthop ; 22: 358-361, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32952326

RESUMEN

OBJECTIVE: Investigate the effect of distal nail diameter on proximal femoral shortening (PFS) after cephalomedullary nailing of hip fractures. METHODS: A retrospective cohort study of 80 patients aged 50 years and older with pertrochanteric hip fractures treated with a 10 or 11 mm short cephalomedullary nail (CMN) was performed. We measured abductor lever arm shortening, femoral height shortening, and PFS. RESULTS: There was no difference in abductor lever arm shortening (p = 0.09), femoral height shortening (p = 0.86), and PFS (p = 0.34) between the 10 and 11 mm groups. CONCLUSIONS: Our results suggest that distal nail diameter does not affect PFS. LEVEL OF EVIDENCE: III.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA