Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.370
Filtrar
1.
BMC Ophthalmol ; 24(1): 410, 2024 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-39300358

RESUMEN

PURPOSE: To compare the biometric measurements obtained from the Pentacam AXL Wave, IOLMaster 700, and ANTERION and calculate the recommended intraocular lens power using the Barrett Formulae. METHODS: This was a retrospective cross-sectional study of patients who underwent biometry using the Pentacam AXL Wave, IOLMaster 700, and ANTERION. Flat keratometry (K1), steep keratometry (K2), anterior chamber depth (ACD), and axial length (AL) from each device were measured and compared. These parameters were used to calculate the recommended IOL powers using the Barrett formula. RESULTS: The study included 252 eyes of 153 patients. The IOLMaster had the highest acquisition rate among the two biometers. The Pentacam obtained the shortest mean AL, the IOLMaster measured the highest mean keratometry values, and the ANTERION measured the highest mean ACD. In terms of pairwise comparisons, keratometry and axial length were not significantly different between the Pentacam-IOLMaster and ANTERION-IOLMaster groups, while the rest of the pairwise comparisons were statistically significant. In nontoric and toric eyes, 35-45% of patients recommended the same sphere of IOL power. In another 30-40%, the Pentacam and ANTERION recommended an IOL power one step greater than that of the IOLMaster-derived data. 50% of the study population recommended the same toric-cylinder IOL power. CONCLUSIONS: The Pentacam AXL Wave, IOLMaster 700, and ANTERION can reliably provide data for IOL power calculations; however, these data are not interchangeable. In nontoric and toric eyes, 35-45% of cases recommended the same sphere IOL power, and in another 30-40%, the Pentacam and ANTERION recommended one-step higher IOL power than the IOLMaster-derived data. In targeting emmetropia, selecting the first plus IOL power is advisable when using the Pentacam and ANTERION to approximate the IOL power calculations recommended by the IOLMaster 700.


Asunto(s)
Biometría , Interferometría , Lentes Intraoculares , Tomografía de Coherencia Óptica , Humanos , Estudios Retrospectivos , Estudios Transversales , Masculino , Biometría/instrumentación , Biometría/métodos , Femenino , Persona de Mediana Edad , Interferometría/instrumentación , Interferometría/métodos , Anciano , Tomografía de Coherencia Óptica/métodos , Tomografía de Coherencia Óptica/instrumentación , Longitud Axial del Ojo/diagnóstico por imagen , Adulto , Anciano de 80 o más Años , Refracción Ocular/fisiología , Óptica y Fotónica , Cámara Anterior/diagnóstico por imagen
2.
Cont Lens Anterior Eye ; : 102291, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39227202

RESUMEN

PURPOSE: To evaluate the impact of short-term scleral lens (SL) wear on anterior chamber (AC) dimension and central corneal thickness (CCT) in healthy Chinese people. METHODS: This is a prospective, daily wear study. Eligible participants were dispensed SLs to correct refractive errors. Anterior segment (AS) parameters were measured by AS optical coherence tomography (AS-OCT) before, during, and after 2 and 4 hours of lens wear. Repeated-measures analysis of variance (ANOVA) was used to analyze the changes in AS parameters over time. RESULTS: Twelve subjects (10 females and 2 males) with a mean age of 25.3 ± 3.8 years (ranging from 21 to 34 years) were recruited. The AC parameters, including anterior chamber depth (ACD) from the endothelium (endo-ACD), angle opening distance at 500 µm (AOD500), and trabecular-iris space area at 500 µm (TISA500), significantly decreased after wearing SLs for 4 hours (P<0.05). CCT increased by 12 µm (2.29 %) after wearing SLs for 4 hours (P=0.013). CONCLUSION: This study suggests that SL wear has a significant impact on AS dimensions in patients with healthy corneas in the short term with SL in situ, but tend to recover quickly after SL removal. Further research is needed to determine whether the change in AS dimensions during SL wear affects aqueous humor (AH) outflow and causes changes in intraocular pressure (IOP).

3.
Ophthalmic Epidemiol ; : 1-8, 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39288329

RESUMEN

PURPOSE: Current study aimed to understand the distribution and determinants of anterior chamber angle (ACA) and anterior chamber volume (ACV) in Chinese young adults, which can help fill current data gaps and aid in early detection and intervention for high-risk population of primary angle closure glaucoma. METHODS: This cross-sectional study utilized data from 2014 participants who completed questionnaire and eye examination in September 2021. ACV and ACA were measured using a Pentacam tomographer. Spherical equivalent (SE) was evaluated by autorefractor without cycloplegia. Central corneal thickness (CCT) and biomechanically corrected intraocular pressure (bIOP) were evaluated using Corvis-ST. Axial length (AL), corneal radius (CR), anterior chamber depth (ACD), and white to white were assessed using the IOL Master. RESULTS: A total of 1635 students were included in the analysis. The mean ACV and AVA were 194.74 ± 32.30 µL and 38.81 ± 4.84°, respectively. Males have a larger ACV and wider ACA than females. ACV was positively correlated with ACA (r = 0.24, p < 0.001), and the correlation was stronger for non-myopic students than for myopic students. Multivariable linear regression model showed that AL (ß = 2.41), CR (ß = -4.12), CCT (ß = -0.11), ACD (ß = 97.93), and bIOP (ß = 0.40) were associated with ACV, and CCT (ß = -0.01), CR (ß = 0.38), and ACD (ß = 7.41) were associated with ACA (all p < 0.05). Random forest model indicated that ACD was the most critical predictor of both ACV and ACA. CONCLUSIONS: This study reported the distribution and determinants of ACA and ACV. Deeper ACD was associated with larger ACV and wider ACA.

4.
Interact J Med Res ; 13: e50106, 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39255482

RESUMEN

BACKGROUND: Anterior chamber-associated immune deviation (ACAID) is an active immunotolerance mechanism, which is induced by placing antigen into the anterior eye chamber as long as a major surgical trauma is avoided. For this reason, ACAID may be a major contributor to the favorable immunologic outcomes in Descemet membrane endothelial keratoplasty (DMEK). Rodent models have demonstrated the importance of a functional spleen for the development of an ACAID. OBJECTIVE: This study aimed to investigate whether splenectomy leads to increased rejection rates after DMEK in humans. METHODS: A retrospective evaluation was conducted on the course following DMEK at the Eye Center, Medical Center, University of Freiburg, for patients with a self-reported history of splenectomy compared to patients without this condition. Potential study patients were contacted by mail. A questionnaire to self-report splenectomy and the time thereof was sent out. The medical records of all consenting patients at the Eye Center were reviewed for graft survival and immune reactions. RESULTS: We asked 1818 patients after DMEK to report their history of splenectomy. A total of 1340 patients responded and were included in the study. Of these 1340 patients, 16 (1.2%) reported a history of splenectomy (ie, 26 DMEKs, with 10 patients being transplanted in both eyes and 6 patients being transplanted in 1 eye; median age at surgery 73.7, range 66.7-76.1 y). The remaining patients (1324 patients, ie, 1941 eyes) served as controls, with 1941 DMEKs (median age at surgery 71.5, range 64.1-77.2 y). Five (19%) out of the 26 eyes from the splenectomy group required a second transplant due to dislocation (n=2.8%), failure (n=2.8%), and rejection (n=1.4%). Kaplan-Meier analysis revealed no relevant difference compared with controls. CONCLUSIONS: Our results suggest that splenectomy has no major effect on the outcome following DMEK. Subsequent, ACAID may not be the main reason for the favorable immunological outcomes in DMEK, or the camero-splenic axis may be subordinate in humans. However, we only included 16 patients who underwent splenectomy, so it might be possible that we missed a minor effect.

5.
Beyoglu Eye J ; 9(3): 120-127, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39239624

RESUMEN

Objectives: To evaluate the long-term structural changes of the anterior chamber (AC) angle following gonioscopy-assisted transluminal trabeculotomy (GATT). Methods: The AC angle of 10 eyes that underwent GATT at least 6 years previously was assessed for structural changes. A detailed gonioscopy was performed to determine the state of the cleft and the position of the trabecular flap. An anterior segment optical coherence tomography (AS-OCT) examination was performed on the corresponding areas on gonioscopy. Results: The typical finding of the angle following GATT was an open cleft with a visible trabecular flap. However, the gonioscopy of our patients revealed three different cleft appearances: open, closed, and segmentally open cleft. In the long-term, the trabecular flap re-approximated the incision site in some areas resulting in the appearance of a closed cleft on gonioscopy. On AS-OCT the cleft was identified when the lumen of Schlemm's canal was connected to the AC, while the position of the flap differed. The cleft was observed as open in median 4.0 (IQR: 2.8-6.0) clock hours. The cleft was found open mostly in the superior quadrants of the angle (nine eyes). No correlation was found between the extent of open cleft and the percentage of IOP reduction. Conclusion: AS-OCT, when used in conjunction with gonioscopy, was found helpful to evaluate the structural changes following GATT. As observed in the study, the cleft tended to close in some areas. It was found preserved mostly in the superior half of the angle in the long term.

6.
Front Med (Lausanne) ; 11: 1418566, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39247635

RESUMEN

Objective: To investigate the pathogenesis of Primary Angle-Closure Glaucoma (PACG) and its relationship with the anatomical structure of the anterior segment by obtaining biometric parameters using the IOL-Master 700. Methods: A retrospective case-control study was conducted. Clinical data from 39 PACG patients and 40 normal controls treated at the Aier Eye Hospital affiliated with Wuhan University from January to December 2022 were collected. Anterior chamber depth (AC), white-to-white (WTW), lens thickness (LT), central corneal thickness (CCT), axial length (AL), corneal curvature (K1), corneal curvature (K2), and lens position (LP) were measured using the IOL-Master 700 to analyze the characteristics and differences in the anterior segment structure of both groups. Statistical methods included independent sample t-tests and logistic regression analysis. Results: Significant differences were found in the anterior segment biometric parameters between PACG patients and normal controls (p < 0.05). Anterior chamber depth, white-to-white, lens thickness, central corneal thickness, axial length, and K2 were all related to the occurrence of PACG (p < 0.05). The occurrence of PACG was negatively correlated with ACD, CCT, and AL (OR = 0.12-0.64, p < 0.05), and positively correlated with LT. Conclusion: Compared to the normal control group, PACG patients in the Hubei region have a smaller anterior segment space, narrower angles, thicker lens, thinner cornea, shorter axial length, flatter cornea, and more anteriorly positioned lens.

7.
Int J Mol Sci ; 25(17)2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39273105

RESUMEN

Proliferative diabetic retinopathy (PDR) is a vision-threatening complication of diabetes mellitus (DM). Anterior chamber (AC) flare and intraocular cytokines are potent biomarkers reflecting the intraocular immune status in PDR. This study aimed to elucidate the complex interrelationship between AC flare and intraocular cytokines in PDR eyes. A retrospective observational study was conducted on 19 PDR eyes of 19 patients with type 2 DM, and on 19 eyes of 19 patients with idiopathic macular hole or epiretinal membrane as controls. AC flare was measured before pars plana vitrectomy (PPV). Aqueous humor (AH) and vitreous fluid (VF) samples were collected at the time of PPV, and the quantities of 27 cytokines in both intraocular fluids were analyzed. In the PDR and control groups, Spearman's rank correlation analysis revealed a positive correlation between AC flare and IL-8 level in both AH and VF. Additionally, IL-8 levels in AH correlated positively with IL-8 levels in VF. In the PDR group, receiver operating characteristic curve analysis identified IL-8 level in AH as a significant predictor for both diabetic macular edema (DME) and vitreous hemorrhage (VH) complications. The cut-off values of IL-8 were established at ≥26.6 pg/mL for DME and ≥7.96 pg/mL for VH. Given the positive correlation between AC flare and AH IL-8 level, the present findings suggest that AC flare value may potentially be a non-invasive biomarker for predicting DME.


Asunto(s)
Cámara Anterior , Humor Acuoso , Retinopatía Diabética , Cuerpo Vítreo , Humanos , Retinopatía Diabética/inmunología , Retinopatía Diabética/metabolismo , Retinopatía Diabética/patología , Retinopatía Diabética/etiología , Masculino , Femenino , Cámara Anterior/patología , Cámara Anterior/metabolismo , Cámara Anterior/inmunología , Persona de Mediana Edad , Anciano , Humor Acuoso/metabolismo , Humor Acuoso/inmunología , Estudios Retrospectivos , Cuerpo Vítreo/metabolismo , Cuerpo Vítreo/patología , Edema Macular/etiología , Edema Macular/metabolismo , Edema Macular/inmunología , Edema Macular/patología , Vitrectomía , Biomarcadores , Citocinas/metabolismo , Interleucina-8/metabolismo , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/metabolismo , Diabetes Mellitus Tipo 2/inmunología , Curva ROC
8.
Clin Ophthalmol ; 18: 2575-2582, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39263254

RESUMEN

Background: We have previously studied the physiological and mechanical responses of the eye to blunt trauma in various situations using finite element analysis (FEA). In this study, we evaluated the volume kinetics of an airbag impact on the eye using FEA to sequentially determine the volume change rates of intraocular segments at various airbag deployment velocities. Methods: The human eye model we created was used in simulations with the FEA program PAM-GENERISTM (Nihon ESI, Tokyo, Japan). Different airbag deployment velocities, 30, 40, 50, 60 and 70 m/s, were applied in the forward direction. The volume of the deformed eye impacted by the airbag was calculated as the integrated value of all meshes in each segment, and the decrease rate was calculated as the ratio of the decreased volume of each segment at particular timepoints to the value before the airbag impact. Results: The minimum volume of the anterior chamber was 63%, 69% and 50% at 50, 60 and 70 m/s airbag impact velocity, respectively, showing a curve with a sharp decline followed by gradual recovery. In contrast to the anterior chamber, the volume of the lens recovered promptly, reaching 80-90% at the end of observation, except for the case of 60 m/s. Following the decrease, the volume increased to more than that of baseline at 60 m/s. The rate of volume change of the vitreous was distributed in a narrow range, 99.2-100.4%. Conclusion: In this study, we found a large, prolonged decrease of volume in the anterior chamber, a similar large decrease followed by prompt recovery of volume in the lens, and a time-lag in the volume decrease between these tissues. These novel findings may provide an important insight into the pathophysiological mechanism of airbag ocular injuries through this further evaluation, employing a refined FEA model representing cuboidal deformation, to develop a more safe airbag system.

9.
Am J Ophthalmol ; 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39218387

RESUMEN

PURPOSE: To demonstrate cases of anterior uveitis requiring more than one anterior chamber paracenesis to elucidate CMV as the causative etiology. DESIGN: Retrospective chart review. METHODS: Patients were seen at the Francis I. Proctor Foundation at the University of California, San Francisco between 2013 to 2024. Patients who required more than one anterior chamber paracentesis to detect CMV as the etiologic agent of their anterior uveitis were included. Number of anterior chamber paracenteses required to detect CMV, demographic and clinical features, viral load at time of positive anterior chamber paracentesis and association between topical corticosteroid use and viral load at time of positive anterior chamber paracentesis. RESULTS: Fourteen patients required a median of 2 (range 2-4) anterior chamber paracenteses to detect CMV. Mean age was 48.2 years, and 57.1% were male. Most patients (64.3%) were born in East and Southeast Asia. All affected eyes featured ocular hypertension. Five patients (35.7%) were initially treated with systemic immunosuppression before CMV was detected. Increasing frequency of topical corticosteroid use was significantly associated with higher CMV viral loads (p<0.001). Five patients (35.7%) required glaucoma surgery. In 13 patients with available data, uveitis was present for an average of 2776 days (range 23-7889 days) prior to CMV detection. Once diagnosed, most patients were treated with oral valganciclovir, with one patient transitioning to letermovir due to side effects. CONCLUSIONS: CMV anterior uveitis may be more prevalent than previously recognized and often requires multiple anterior chamber paracenteses for diagnosis. Reliance on a signle negative test may lead to misdiagnosis and inappropriate treatment. Clinicians should maintain a high index of suspicion for CMV in cases of recurrent anterior uveitis, particularly in patients of East and Southeast Asian descent. This study highlights the importance of repeated testing and appropriate antiviral treatment to prevent complications such as glaucoma.

10.
BMJ Case Rep ; 17(8)2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39179261

RESUMEN

Acute retinal necrosis (ARN) is a rare and rapidly progressive disease characterised by the development of panuveitis and peripheral retinal lesions. These lesions can often be missed during a routine fundoscopic examination, making the early diagnosis of ARN a considerable challenge. This case report describes the utilisation of ultrawidefield (UWF) imaging in the early detection of peripheral lesions associated with ARN in a male patient in his late 60s, who presented with acute blurred vision and a documented history of herpes zoster ophthalmicus. During a comprehensive eye examination and UWF imaging, panuveitis and peripheral lesions were identified, eventually leading to a diagnosis of ARN. The early initiation of antiviral therapy led to a gradual clinical improvement over 3-4 months. The utilisation of serial UWF imaging played a critical role in the prompt diagnosis and effective monitoring of disease progression, thereby potentially improving the patient's outcome.


Asunto(s)
Antivirales , Diagnóstico Precoz , Herpes Zóster Oftálmico , Síndrome de Necrosis Retiniana Aguda , Humanos , Síndrome de Necrosis Retiniana Aguda/tratamiento farmacológico , Síndrome de Necrosis Retiniana Aguda/diagnóstico , Masculino , Antivirales/uso terapéutico , Herpes Zóster Oftálmico/tratamiento farmacológico , Herpes Zóster Oftálmico/diagnóstico , Anciano , Persona de Mediana Edad
11.
BMC Ophthalmol ; 24(1): 349, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39152392

RESUMEN

BACKGROUND: Accurate prediction of postoperative vault in implantable collamer lens (ICL) implantation is crucial; however, current formulas often fail to account for individual anatomical variations, leading to suboptimal visual outcomes and necessitating improved predictive models. We aimed to verify the prediction accuracy of our new predictive model for vaulting based on anterior and posterior chamber structural parameters. METHODS: This retrospective observational study included 137 patients (240 eyes) who previously underwent ICL surgery. Patients were randomly divided into the model establishment (192 eyes) or validation (48 eyes) groups. Preoperative measurements of the anterior and posterior chamber structures were obtained using Pentacam, CASIA2 anterior segment optical coherence tomography (AS-OCT), ultrasound biomicroscopy, and other devices. Stepwise multiple linear regression analysis was used to evaluate the relationship between the vault and each variable (WL formula). The Friedman test was performed for the vaulting prediction results of the WL, NK (Ver. 3), and KS formulas (Ver. 4) in CASIA2 AS-OCT, as well as the Zhu formula and vault measurements. The proportions of prediction error within ± 250 µm per formula were compared. RESULTS: The predicted vault values of the WL, NK, KS, and Zhu formulas and vault measurements were 668.74 ± 162.12, 650.85 ± 248.47, 546.56 ± 128.99, 486.56 ± 210.76, and 716.06 ± 233.84 µm, respectively, with a significant difference (χ2 = 69.883, P = 0.000). Significant differences were also found between the measured vault value and Zhu formula, measured vault value and KS formula, WL formula and Zhu formula, WL formula and KS formula, NK formula and KS formula, and NK formula and Zhu formula (P < 0.001) but not between other groups. The proportions of prediction error within ± 250 µm per formula were as follows: WL formula (81.3%) > NK formula (70.8%) > KS formula (66.7%) > Zhu formula (54.2%). CONCLUSIONS: The WL formula, which considers the complexity of the anterior and posterior chamber structures, demonstrates greater calculation accuracy, compared with the KS (Ver. 4) and Zhu formulas. The proportion of absolute prediction error ≤ 250 µm is higher with the WL formula than with the NK formula (ver. 3). This enhanced predictive capability can improve ICL sizing decisions, thereby increasing the safety and efficacy of ICL implantation surgeries.


Asunto(s)
Implantación de Lentes Intraoculares , Tomografía de Coherencia Óptica , Humanos , Estudios Retrospectivos , Femenino , Masculino , Tomografía de Coherencia Óptica/métodos , Adulto , Implantación de Lentes Intraoculares/métodos , Cámara Anterior/diagnóstico por imagen , Lentes Intraoculares Fáquicas , Miopía/cirugía , Microscopía Acústica/métodos , Adulto Joven , Persona de Mediana Edad , Agudeza Visual , Biometría/métodos , Refracción Ocular/fisiología
12.
BMC Ophthalmol ; 24(1): 326, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39103785

RESUMEN

PURPOSE: To research the accuracy of intraocular lens (IOL) calculation formulas and investigate the effect of anterior chamber depth (ACD) and lens thickness (LT) measured by swept-source optical coherence tomography biometer (IOLMaster 700) in patients with posterior chamber phakic IOL (PC-pIOL). METHODS: Retrospective case series. The IOLMaster 700 biometer was used to measure axial length (AL) and anterior segment parameters. The traditional formulas (SRK/T, Holladay 1 and Haigis) with or without Wang-Koch (WK) AL adjustment, and new-generation formulas (Barret Universal II [BUII], Emmetropia Verifying Optical [EVO] v2.0, Kane, Pearl-DGS) were utilized in IOL power calculation. RESULTS: This study enrolled 24 eyes of 24 patients undergoing combined PC-pIOL removal and cataract surgery at Xiamen Eye Center of Xiamen University, Xiamen, Fujian, China. The median absolute prediction error in ascending order was EVO 2.0 (0.33), Kane (0.35), SRK/T-WKmodified (0.42), Holladay 1-WKmodified (0.44), Haigis-WKC1 (0.46), Pearl-DGS (0.47), BUII (0.58), Haigis (0.75), SRK/T (0.79), and Holladay 1 (1.32). The root-mean-square absolute error in ascending order was Haigis-WKC1 (0.591), Holladay 1-WKmodified (0.622), SRK/T-WKmodified (0.623), EVO (0.673), Kane (0.678), Pearl-DGS (0.753), BUII (0.863), Haigis (1.061), SRK/T (1.188), and Holladay 1 (1.513). A detailed analysis of ACD and LT measurement error revealed negligible impact on refractive outcomes in BUII and EVO 2.0 when these parameters were incorporated or omitted in the formula calculation. CONCLUSION: The Kane, EVO 2.0, and traditional formulas with WK AL adjustment displayed high prediction accuracy. Furthermore, the ACD and LT measurement error does not exert a significant influence on the accuracy of IOL power calculation formulas in highly myopic eyes implanted with PC-pIOL.


Asunto(s)
Biometría , Catarata , Lentes Intraoculares Fáquicas , Refracción Ocular , Tomografía de Coherencia Óptica , Humanos , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Femenino , Masculino , Persona de Mediana Edad , Biometría/métodos , Refracción Ocular/fisiología , Catarata/complicaciones , Adulto , Óptica y Fotónica , Reproducibilidad de los Resultados , Anciano , Longitud Axial del Ojo/diagnóstico por imagen , Longitud Axial del Ojo/patología , Cámara Anterior/diagnóstico por imagen , Agudeza Visual/fisiología , Implantación de Lentes Intraoculares/métodos
13.
Clin Exp Ophthalmol ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39119923

RESUMEN

BACKGROUND: To establish a novel vault prediction formula after implantable collamer lens (ICL) implantation that considers both anterior and posterior chamber characteristics with multi-modal parameters. METHODS: A total of 103 and 65 eyes were included in the development and validation groups, respectively. Exploratory factor analysis was performed using data from optical coherence tomography and ultrasound biomicroscopy in the development group to synthesise summative factors with different clinical significance. Dominant original metrics with heavy loadings on significant factors (absolute value of the loading coefficient >0.5) were screened for multivariate linear regression models using a stepwise method. The newly derived formula was evaluated and compared to the NK and KS formulas in the validation group. RESULTS: Six factors (anterior chamber angle, horizontal width, lens, iris, iridociliary complex and ciliary body) were generated after dimension reduction via factor analysis. Factors 2 (horizontal width), 3 (lens), and 5 (iridociliary complex) had a significant influence on the vault. When dominant metrics on these factors were screened for further model building, ICL size, anterior chamber width, crystalline lens rise, iris curvature, and iris-ciliary process distance were retained in the final formula, with an adjusted R2 of 0.698, a median absolute error of 81.97 mm, and a root-mean-square error of 103.35 mm. CONCLUSIONS: Multiple intraocular components, including the lens, iris, and ciliary body, play important roles in vault determination. The new formula exhibits good accuracy for vault predictions and ICL size recommendations.

15.
Br J Ophthalmol ; 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39089846

RESUMEN

BACKGROUND/AIMS: To explore and characterise the clinical phenotype of acute anterior uveitis flares with delayed severity in patients with human leucocyte antigen B27 (HLA-B27)-associated anterior uveitis. METHODS: Retrospective chart review of patients with HLA-B27-associated anterior uveitis. Demographic and clinical data were recorded, as well as the clinical characteristics of acute anterior uveitis flares. A flare was considered to have delayed severity if any of the following criteria were met within 3-21 days of symptomatic onset: a two-step increase in anterior chamber inflammation on consecutive exams; a new development of hypopyon or fibrinoid aqueous reaction on consecutive examinations or a significant worsening of symptoms. RESULTS: A total of 371 patient charts were identified, of which 137 were included. 321 acute anterior uveitis flares were documented, with 36 (11.2%) meeting the criteria for a delayed severity flare. The average time from symptomatic onset was 10.2 days, and patients presented with an average anterior chamber cell grade of 3.5 in delayed severity flares compared with 1.6 in non-delayed severity flares. No significant difference in frequency of delayed severity presentation was noted based on the presence or absence of systemically associated rheumatological disease, papillitis on initial presentation and retinal vasculitis on initial presentation. The frequency of topical steroid therapy after symptomatic onset was not significantly different between the two flare phenotypes. CONCLUSIONS: Our study presents the novel characterisation of a delayed severity phenotype of HLA-B27-associated acute anterior uveitis flares.

16.
Br J Ophthalmol ; 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39214678

RESUMEN

AIM: To evaluate reproducibility and agreement of angle closure assessment by a novel hyperparallel optical coherence tomography (OCT) system (HP-OCT, Cylite Optics, Melbourne, Australia), in comparison with swept-source OCT (SS-OCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan) and gonioscopy. METHODS: Cross-sectional study. Phakic subjects >40 years, with no relevant ophthalmic history were consecutively recruited from the glaucoma clinic. Subjects underwent same-day evaluation with HP-OCT, SS-OCT and gonioscopy. The primary outcome was the presence of angle closure, defined as iridotrabecular contact in HP-OCT and SS-OCT images at 0°-180° meridional and as non-visibility of the posterior trabecular meshwork (TM) by gonioscopy. Visibility of TM was also assessed (secondary outcome). Intra and interdevice agreement analysis (Gwet AC1) and logistic regression analysis were performed for primary and secondary outcomes, respectively. RESULTS: 154 sectors from horizontal scans of 77 subjects were analysed. The reproducibility of angle closure assessment by HP-OCT was excellent (AC1 of 0.95 for temporal angle and 1.00 for nasal). Agreement for angle closure detection was very good between HP-OCT and SS-OCT (AC1 of 0.88 for temporal and 0.81 for nasal angle) and good between HP-OCT and gonioscopy (AC1 of 0.71 for temporal and 0.78 for nasal angle). TM was identifiable in 64.4% (94/146) of unprocessed HP-OCT images (both open and closed angles), however not visible in any of the SS-OCT unprocessed images. CONCLUSIONS: HP-OCT showed excellent reproducibility for angle closure assessment and good agreement with SS-OCT and gonioscopy. HP-OCT technology also provides a unique capability to visualise regions around TM and Schlemm's canal, opening new avenues for clinical research of distal outflow pathways.

17.
Artículo en Inglés | MEDLINE | ID: mdl-39206080

RESUMEN

Background: The effects of trabeculectomy on anterior segment parameters have been widely investigated. However, the stabilization time for various glaucoma types after trabeculectomy remains debatable. We investigated the effect of mitomycin C-augmented trabeculectomy on ocular anterior segment parameters in primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (PXG) during short-term follow-up using the Pentacam HR. Methods: In this retrospective observational study, consecutive patients diagnosed with medically uncontrolled POAG or PXG who underwent MMC-augmented trabeculectomy were recruited. All individuals underwent detailed ocular examinations. All trabeculectomies were performed by a single surgeon using the same technique. Anterior segment parameters, including anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), and central corneal thickness (CCT) were measured using the Pentacam HR, along with intraocular pressure (IOP) using a Goldmann applanation tonometer, pre-operatively and at 1-week, 1-month, and 3-month post-operative visits. Results: We included 80 patients with a median (range) age of 58.0 (41.0-86.0) years having a nearly similar sex ratio. The study groups were matched according to sex and age (both P > 0.05). The group-by-time interaction was significant for CCT and ACV (both P < 0.05) but not for IOP, ACD, and ACA (all P > 0.05). The mean (standard deviation [SD]) IOP, ACD, and ACA were comparable between groups (all P > 0.05) during the 3-month period; however, they changed significantly over time in both groups (all P < 0.001). The mean CCT and ACV were comparable between groups at each time point (all P > 0.05), except at the 1-month post-operative visit, at which the mean (SD) ACV was significantly lower in the PXG group (P < 0.05). We found a comparable mean (SD) CCT between paired visits in each group (all P > 0.05), except for the mean (SD) CCT at 3 months, which was significantly lower than that at the 1-month post-operative visit in the PXG group (P < 0.05). We found a comparable mean (SD) ACV between paired visits in each group (all P > 0.05); however, it was significantly lower at the 1-month post-operative versus the baseline visit in both groups and resumed a significantly higher value at the 1-month versus the 1-week visit and at the 3-month versus the 1-month visit in the PXG group (all P < 0.05). Conclusions: We observed significant changes in IOP, ACD, and ACA over 3 months after post-augmented trabeculectomy in eyes with POAG and PXG; however, the majority of anterior segment parameters were comparable between the two groups. Further large-scale studies with longer follow-up periods should be conducted to verify the post-operative fluctuations in these parameters in POAG and PXG.

18.
BMC Pulm Med ; 24(1): 418, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39198799

RESUMEN

BACKGROUND: Chronic obstructive pulmonary disease (COPD) is a persistent, chronic inflammatory disease of the lungs. Tiotropium, used in the treatment of COPD, is a muscarinic receptor antagonist that provides long-acting bronchodilation. Our study aimed to investigate the effects of Tiotropium on anterior chamber parameters. METHODS: The study was conducted as an observational cross-sectional and prospectively between October 2023 and April 2024. Patients were examined in three groups: Group 1 consisted of untreated COPD patients; Group 2 consisted of healthy volunteers similar age and gender, and Group 3 included COPD patients receiving Tiotropium 18 mcg via HandiHaler. Anterior chamber parameters, intraocular pressure values, and photopic-mesopic pupil diameters were measured at the initial visit for Group 1 and Group 2 patients, and at the third month of treatment for Group 3 patients. RESULTS: Thirty-six patients were included in each group in the study. No significant differences were observed in ocular findings between the patient and control groups. In COPD patients receiving Tiotropium, narrowing of angle parameters, an increase in photopic-mesopic pupil diameters, and intraocular pressure were observed at the third month of treatment. CONCLUSION: This study is the first research that investigate the effects of Tiotropium on anterior chamber parameters, pupil diameters, and intraocular pressure in COPD treatment. In conclusion, patients with COPD receiving Tiotropium therapy for three months showed narrowing in angle parameters, an increase in intraocular pressure, and photopic-mesopic pupil diameter; however, no patients developed drug-induced acute angle closure glaucoma. TRIAL REGISTRATION: An independent ethics committee approved the study (Giresun EAH KEAK 2023/180 and 9.10.2023/02) which was performed in accordance with the Declaration of Helsinki, Guidelines for Good Clinical Practice. The study was conducted as prospectively, observational case-control. The Clinical Trial Number obtained for the study is NCT06525051 and was taken on 2024-07-29.


Asunto(s)
Broncodilatadores , Presión Intraocular , Enfermedad Pulmonar Obstructiva Crónica , Bromuro de Tiotropio , Humanos , Bromuro de Tiotropio/uso terapéutico , Bromuro de Tiotropio/administración & dosificación , Enfermedad Pulmonar Obstructiva Crónica/tratamiento farmacológico , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Femenino , Masculino , Estudios Transversales , Persona de Mediana Edad , Estudios Prospectivos , Anciano , Presión Intraocular/efectos de los fármacos , Broncodilatadores/uso terapéutico , Cámara Anterior/efectos de los fármacos , Pupila/efectos de los fármacos
19.
BMJ Case Rep ; 17(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38960431

RESUMEN

A man in his 60s presented with diminution of vision of the left eye with nasal bleeding after accidental fall. On examination his left upper eyelid was lacerated and left temporal sclera was punctured which was repaired under local anaesthesia after which he was discharged by ophthalmologists but continued to complain of pain and left nasal obstruction. A non-contrast CT of paranasal sinuses revealed fracture of medial wall of left orbit, left ethmoid haemosinus and a metallic foreign body (FB) in the septum and anterior face of sphenoid. Diagnostic nasal endoscopy performed to remove the metallic FB showed plastic splinters embedded in the mucosa of nasal cavity which was unexpected. Hence, the FB was removed in two sittings because of diagnostic dilemma.


Asunto(s)
Cuerpos Extraños , Humanos , Masculino , Persona de Mediana Edad , Cuerpos Extraños/cirugía , Cuerpos Extraños/diagnóstico por imagen , Cuerpos Extraños/complicaciones , Tomografía Computarizada por Rayos X , Nariz/lesiones , Accidentes por Caídas , Fracturas Orbitales/cirugía , Lesiones Oculares/complicaciones , Lesiones Oculares/cirugía , Lesiones Oculares/etiología , Endoscopía/métodos , Obstrucción Nasal/etiología , Obstrucción Nasal/cirugía , Órbita/lesiones , Órbita/diagnóstico por imagen , Lesiones Oculares Penetrantes/cirugía , Lesiones Oculares Penetrantes/diagnóstico por imagen , Lesiones Oculares Penetrantes/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA