Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Asian J Neurosurg ; 19(3): 501-512, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39205888

RESUMEN

Purpose There have been numerous advancements in the strategies used for treating mandibular fractures in the present times, while open reduction and internal fixation is still accepted as the most preferred treatment option for such fractures despite numerous drawbacks. The aim of the present prospective, randomized controlled study was to evaluate the clinical outcome including neurosensory deficit and pain score variables in mandibular fractures that were treated using rigid internal fixation with three-dimensional (3D) miniplate internal fixation. Materials and Methods For the present study, a total of 20 patients of either sex in an age range of 18 to 55 years with simultaneous angle and contralateral body/parasymphysis fractures of the mandible were included, while the clinical outcome was compared in relation to the two groups wherein different treatment options were used including using rigid internal fixation in one as against 3D miniplate internal fixation in the other. Results Pairwise comparison of pain scores in Group I and Group II patients by the Mann-Whitney U-test at different time zones revealed the results to be statistically significant for all pairs except when the findings were compared between 1 month and 3 months after the procedure in Group II patients. Also, significant recovery was observed in both Group I and II patients during healing when assessed preoperatively to 1 month and then 3 months after the procedure with the results being statistically highly significant in case of the variations observed in relation to the neurosensory deficit observed at different time zones for both Group I and II patients ( p = 0.0001). Conclusion Based on the results obtained, it can be concluded that 3D miniplate-led osteosynthesis was found comparable to the osteosynthesis accomplished using reconstruction plates during fixation of unfavorable body/parasymphysis fractures of mandible in study, providing optimal stability, while satisfactorily meeting the biomechanical requirements for occlusal loading, and an early return to normal function.

2.
Cureus ; 13(11): e19891, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34976503

RESUMEN

Craniotomy, cranioplasty, and craniofacial procedures may involve reoperation for additional treatment of the primary pathological condition or treatment of complications, requiring removal of previously placed hardware. During removal of the titanium hardware, there is a risk of losing, dropping, or misplacing the titanium screws because of their small size. There are also instances of difficulty disengaging the screw from the screwdriver. We describe the use of a plastic specimen cup in retrieving titanium screws after detaching them from the screwdriver by screwing the screw into the cup, thus rapidly and safely securing and storing screws for collection/discarding or possible reuse. When the empty screwdriver is used to retrieve and unscrew the titanium screw from the cranial flap or the skull bone, a plastic specimen cup should be placed adjacent to the site of screw removal. Once the screw is removed, while it is still fastened to the screwdriver, it is immediately re-screwed and secured onto the base of the plastic specimen cup, which is then placed into a second plastic specimen cup. This method prevents misplacement or dropping of the screw that may otherwise occur when manipulating the screw on or off the screwdriver and avoids perforating the surgeon's glove during handling. We describe the adjunctive use of a plastic specimen cup when removing cranial screws and hardware to rapidly and safely detach the screw and prevent the misplacement, dropping, or loss of screws intraoperatively that results in additional operative time and personnel assistance.

3.
J Clin Med ; 9(9)2020 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-32927799

RESUMEN

The aim of this study was to evaluate the effectiveness of open treatment of mandibular condyle fractures using 3D miniplates. A group of 113 patients has been chosen for evaluation, including 100 men and 13 women. After hospitalization, each patient underwent a 6-month postoperative follow-up. The material chosen for the analysis consisted of data collected during the patient's stay in the hospital as well as the postoperative outpatient care. A single 4-hole Delta Condyle Compression Plate (4-DCCP) was used in 90 out of 113 (79.6%) cases. In 16 out of 113 (14.2%) patients, the Trapezoid Condyle Plate (4-TCP or 9-TCP) was used. The remaining cases required more than one miniplate. No 3D miniplate fractures were found in the study subjects during the analyzed observation period. Loosening of one or more osteosynthesis screws was observed in 4 out of 113 (3.5%) patients. Screw loosening was a complication that did not affect bone healing in any of the patient cases. The conducted research confirms that titanium 3D mini-plates are easy to adjust and take up little space, therefore they can easily be used in cases of mandibular condyle base and lower condyle neck fractures. The stability of the three-dimensional miniplates for osteosynthesis gives very good reliability for the rigid fixation of the fractured mandibular condyle.

4.
J Maxillofac Oral Surg ; 13(2): 79-83, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24821994

RESUMEN

PURPOSE: To compare the efficacy of the 3D miniplates to standard miniplates in the osteosynthesis of mandibular symphysis and parasymphysis fractures on the basis of clinical parameters and radiographic evaluation. PATIENTS AND METHODS: A prospective randomized clinical trial was conducted to treat consecutive mandibular symphysis and parasymphysis fractures. The patients were randomly divided into 2 groups. The patients underwent osteosynthesis in group A with 3D titanium miniplates and in group B with conventional titanium miniplates. The cause of trauma, the number of days from injury to surgery, average age and gender were all reviewed. The assessment of the patients was done at 1, 3, and 6 weeks and 3 months using the clinical parameters and radiographic evaluation. RESULTS: Eighty patients with isolated symphysis or parasymphysis fracture met the inclusion criteria. In our study, a statistically significant difference was not found in the clinical parameters such as pain, swelling, infection, paresthesia, hardware failure, and mobility between the fracture segments. Similarly Radiological evaluation did not show any statistically significant difference in reduction between the 2 groups. 3D plates are difficult to adapt and use sometimes, but operative time is less with them in treatment of symphysis and parasymphysis fractures. CONCLUSION: The use of 3D miniplates for symphysis and parasymphysis fracture fixation was efficacious enough to bear the masticatory load during osteosynthesis of the fracture. Although 3D miniplate system is difficult to adapt and difficult to use in cases of fractures involving the mental nerve, they provide the advantage of less operative time and less implant material in treatment of symphysis and parasymphysis fracture, with clinical results almost similar to those seen with conventional miniplate osteosynthesis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA