Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Adv Healthc Mater ; 6(4)2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28009096

RESUMEN

There is an urgent need to develop new diagnosis tools for real in vivo detection of first stages of ischemia for the early treatment of cardiovascular diseases and accidents. However, traditional approaches show low sensitivity and a limited penetration into tissues, so they are only applicable for the detection of surface lesions. Here, it is shown how the superior thermal sensing capabilities of near infrared-emitting quantum dots (NIR-QDs) can be efficiently used for in vivo detection of subcutaneous ischemic tissues. In particular, NIR-QDs make possible ischemia detection by high penetration transient thermometry studies in a murine ischemic hindlimb model. NIR-QDs nanothermometers are able to identify ischemic tissues by means of their faster thermal dynamics. In addition, they have shown to be capable of monitoring both the revascularization and damage recovery processes of ischemic tissues. This work demonstrates the applicability of fluorescence nanothermometry for ischemia detection and treatment, as well as a tool for early diagnosis of cardiovascular disease.


Asunto(s)
Rayos Infrarrojos , Isquemia/diagnóstico por imagen , Mediciones Luminiscentes/métodos , Puntos Cuánticos/química , Termómetros , Termometría/métodos , Animales , Ratones
2.
Nano Lett ; 16(3): 1695-703, 2016 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-26845418

RESUMEN

The recent development of core/shell engineering of rare earth doped luminescent nanoparticles has ushered a new era in fluorescence thermal biosensing, allowing for the performance of minimally invasive experiments, not only in living cells but also in more challenging small animal models. Here, the potential use of active-core/active-shell Nd(3+)- and Yb(3+)-doped nanoparticles as subcutaneous thermal probes has been evaluated. These temperature nanoprobes operate in the infrared transparency window of biological tissues, enabling deep temperature sensing into animal bodies thanks to the temperature dependence of their emission spectra that leads to a ratiometric temperature readout. The ability of active-core/active-shell Nd(3+)- and Yb(3+)-doped nanoparticles for unveiling fundamental tissue properties in in vivo conditions was demonstrated by subcutaneous thermal relaxation monitoring through the injected core/shell nanoparticles. The reported results evidence the potential of infrared luminescence nanothermometry as a diagnosis tool at the small animal level.


Asunto(s)
Mediciones Luminiscentes/instrumentación , Nanopartículas/química , Neodimio/química , Termómetros , Iterbio/química , Administración Cutánea , Animales , Temperatura Corporal , Rayos Infrarrojos , Luminiscencia , Ratones , Nanopartículas/administración & dosificación , Neodimio/administración & dosificación , Fenómenos Fisiológicos de la Piel , Iterbio/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA