Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ann Thorac Surg ; 85(6): 2139-40, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18498847

RESUMEN

Aneurysm of the left atrial appendage (LAA) is very infrequent. We present the case of 24-year-old man in functional class I with atrial fibrillation but no other symptoms. Radiology showed an abnormality in the outline of the heart. Echocardiography revealed left appendage aneurysm. After median sternotomy, aneurysmectomy was performed under cardiopulmonary bypass without cross clamping. Atrial fibrillation ceased as soon as the aneurysm had been removed. There were no postoperative complications. Three months later the patient remained asymptomatic and in sinus rhythm.


Asunto(s)
Apéndice Atrial/anomalías , Fibrilación Atrial/etiología , Aneurisma Cardíaco/congénito , Adulto , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/patología , Apéndice Atrial/cirugía , Descompresión Quirúrgica/instrumentación , Estudios de Seguimiento , Aneurisma Cardíaco/diagnóstico por imagen , Aneurisma Cardíaco/patología , Aneurisma Cardíaco/cirugía , Humanos , Masculino , Instrumentos Quirúrgicos , Ultrasonografía
2.
Artif Organs ; 26(10): 851-5, 2002 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12296924

RESUMEN

We evaluated our results over 13 years with the aortic-position Medtronic Intact bioprosthesis. Our study involved 91 consecutive patients with isolated aortic valve replacement with the Medtronic Intact bioprosthesis. The follow-up was complete for 95%. Mean follow-up was 6.61 years (range 16 days-13 years), 590 patient years. Early mortality rate was 3.3%. Late mortality was 23 patients. Survival at 13 years was 53.52% (SD = 7.63%). The linearized rate of major thromboembolism was 0.34% per patient year; rate of major bleeding events was 0.33% per patient year. The rate of nonstructural dysfunction was 0.16% per patient year. Rate of reoperation was 0.53% and rate of structural valve deterioration was 0.16% per patient year. New York Heart Association (NYHA) postoperative classes were I to II in 92.21%. Gradients were as follows: 21 to 23.87 mm Hg, 23 to 18 mm Hg, 25 to 15.5 mm Hg, and 27 to 16.50 mm Hg. Structural valve deterioration was low during the 13 years of follow-up. Valve gradients and areas remained the same over the follow-up period. The Medtronic Intact bioprosthesis shows excellent clinical and hemodynamic performance at 13 years of follow up.


Asunto(s)
Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Bioprótesis , Enfermedades de las Válvulas Cardíacas/fisiopatología , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas , Hemodinámica/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA