Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Transplant Proc ; 42(2): 535-8, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20304186

RESUMEN

BACKGROUND: Heart transplantation (OHT) has traditionally been contraindicated in the presence of severe pulmonary hypertension (PH), as detected by right heart catheterization. Noninvasive methods are still not reliably accurate to make this evaluation. OBJECTIVES: Determine the efficacy of echo Doppler analysis for the diagnosis of severe PH. METHODS: One hundred thirty patients (mean age = 42 +/- 15 years, 82 men) showed severe left ventricular dysfunction (mean ejection fraction = 29 +/- 12%; functional class III-IV). We excluded patients with atrial fibrillation, heart failure secondary to congenital disease, and valvulopathy. The pulmonary parameters defined as severe PH were: systolic pulmonary artery pressure (sPAP) >or= 60 mm Hg; a mean transpulmonary gradient >or= 15; or pulmonary vascular resistance >or= 5 Wood units. Patients underwent a right heart catheterization using a Swan-Ganz catheter to measure hemodynamic parameters and to noninvasively estimate right-sided pressures from spectral Doppler recordings of tricuspid regurgitation velocity (right ventricular systolic pressure [RVsP]). A Pearson correlation of sPAP was obtained with RVsP by; the sensitivity of RVsP for the diagnosis of PH was determined by a receiver operating characteristic (ROC) curve. RESULTS: A good correlation between sPAP and RVsP was obtained by Pearson correlation analysis (r = 0.64; 95% confidence interval [CI] 0.50-0.75; P < .001). The ROC curve analysis showed a sensitivity of 100%, a specificity of 37.2%, (95% CI 0.69-0.83, P < .0001) of a RVsP < 45 mm Hg (cutoff) on the exclusion of severe PH. CONCLUSIONS: The cutoff of RVsP < 45 mm Hg, on noninvasive echo Doppler evaluation of PH is an efficient method to replace invasive heart catheterization in OHT candidates.


Asunto(s)
Endosonografía/métodos , Trasplante de Corazón/fisiología , Hipertensión Pulmonar/diagnóstico por imagen , Volumen Sistólico/fisiología , Adolescente , Adulto , Anciano , Presión Sanguínea , Cateterismo Cardíaco , Niño , Contraindicaciones , Ecocardiografía/métodos , Femenino , Ventrículos Cardíacos/fisiopatología , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sístole , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Resistencia Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA