1.
Int J Oral Maxillofac Surg ; 43(10): 1251-6, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25124390

RESUMEN

The surgical treatment of mandibular condyle fractures currently offers several possibilities for stable internal fixation. In this study, a finite element model evaluation was performed of three different methods for osteosynthesis of low subcondylar fractures: (1) two four-hole straight plates, (2) one seven-hole lambda plate, and (3) one four-hole trapezoidal plate. The finite element model evaluation considered a load applied to the first molar on the contralateral side to the fracture. Results showed that, although the three methods are capable of withstanding functional loading, the lambda plate displayed a more homogeneous stress distribution for both osteosynthesis material and bone and may be a better method when single-plate fixation is the option.


Asunto(s)
Placas Óseas , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Técnicas de Fijación de Maxilares , Cóndilo Mandibular/lesiones , Fracturas Mandibulares/cirugía , Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Humanos , Técnicas de Fijación de Maxilares/instrumentación , Titanio , Resultado del Tratamiento