RESUMEN
BACKGROUND: The criterion (gold) standard to detect anti-human leukocyte antigen (HLA) antibodies is the complement-dependent cytotoxicity (CDC) assay. Recently, more sensitive methods have been used for the same purpose. METHODS: This study analyzed 70 serum samples of patients with end-stage renal disease using CDC, CDC with the addition of anti-human globulin (CDC-AHG), CDC with the addition of dithiothreitol (CDC-DTT), and the recent solid-phase immunoassay (SPI; Labscreen PRA) to detect anti-HLA antibodies. RESULTS: Mean percent panel reactive antibodies (PRA) detected by SPI was 37.5% (±34.2) higher than the values detected by the other methods. Comparative analyses revealed significant difference between CDC and CDC-AHG, and between CDC and SPI (P < 0.0001), but not between CDC-AHG and SPI (P = 0.8026). CONCLUSION: Although the CDC-AHG method is "old," its performance to detect anti-HLA antibodies in the samples analyzed was comparable to the SPI in the evaluation of percent class I PRA.
Asunto(s)
Anticuerpos/inmunología , Proteínas del Sistema Complemento/metabolismo , Citotoxicidad Inmunológica , Antígenos HLA/inmunología , Especificidad de Anticuerpos/inmunología , Ditiotreitol/metabolismo , Globulinas/inmunología , Humanos , InmunoensayoRESUMEN
The phenolic compounds are the main phytochemical constituents of the bark of Trichilia catigua and are commonly used for medicinal purposes. An HPLC method for the simultaneous quantification of phenolic compounds (procyanidin B2 (PB2), epicatechin (EPC), chinchonains Ia, Ib, IIa, IIb, catechin, and chrologenic acid) in T. catigua extract was developed and validated. A suitable chromatographic system was selected, which uses a gradient elution with methanol/ACN (75:25), and water both with 0.05% TFA, as mobile phase, column Luna, 280 nm, and flow 0.4 mL/min. Validation of the analytical method was based on the parameters: linearity, precision, LODs and LOQs, accuracy, robustness, and stability. The method showed linearity for PB2 and EPC, in the range 10-120 µg/mL with good correlation coefficients (>0.996). For precision, the repeatability ranged from 1.89 to 3.23%, and the values for accuracy for PB2 and EPC were 95 and 89%, respectively. The LODs and LOQs for PB2 were 1.36 and 4.12 µg/mL, and for EPC were 2.18 and 6.61 µg/mL, respectively. The method was robust under the conditions employed. The proposed method could be employed for quality assessment of T. catigua, as well as pharmaceutical products.