Proteomics Clin Appl ; : e202300238, 2024 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-39073314

RESUMEN

PURPOSE: Obesity and its associated metabolic disorders, such as T2DM and MeS, are a growing public health problem worldwide. Our goal was the identification of protein patterns that are uniquely characteristic of higher BMI, MeS, and T2DM in a Brazilian population. EXPERIMENTAL DESIGN: Saliva and plasma proteomes, clinical parameters were analyzed in a population from the state of Rio de Janeiro, Brazil, a mixed-race population. Volunteers were sorted by their BMI into normal (n = 29), overweight (n = 25), and obese (n = 15) and were compared with individuals with MeS (n = 23) and T2DM (n = 11). RESULTS: The Random Forest (RF) predictive model revealed that three clinical variables, BMI, HOMA-IR, and fasting blood glucose, are most important for predicting MeS and T2DM. A total of six plasmatic proteins (ABCD4, LDB1, PDZ, podoplanin, lipirin-alpha-3, and WRS) and six salivary proteins (hemoglobin subunit beta, POTEE, T cell receptor alpha variable 9-2, lactotransferrin, cystatin-S, carbonic anhydrase 6), are enhanced in T2DM and in MeS. CONCLUSIONS AND CLINICAL RELEVANCE: Our data revealed similar alterations in protein composition across individuals with abnormal weight gain, T2DM, and MeS. This finding confirms the close link between these conditions at the molecular level in the studied population, potentially enhancing our understanding of these diseases and paving the way for the development of novel diagnostic tools.

2.
Appl Radiat Isot ; 200: 110945, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37515859

RESUMEN

The Bureau International des Poids et Mesures (BIPM) is developing a new transfer instrument to extend its centralized services for assessing the international equivalence of radioactive standards to new radionuclides. A liquid scintillation counter using the triple/double coincidence ratio method is being studied and tested in the CCRI(II)-P1.Co-60 pilot study. The pilot study, involving 13 participating laboratories with primary calibration capabilities, validated the approach against the original international reference system based on ionization chambers, which has been in operation since 1976. The results are in agreement and an accuracy suitable for purpose, below 5×10-4, is achieved. The pilot study also reveals an issue when impurities emitting low-energy electrons are present in the standard solution, which have a different impact on liquid scintillation counting compared to other primary measurement methods.

3.
Appl Radiat Isot ; 116: 157-62, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27544313

RESUMEN

The performance of a Cadmiun Telluride (CdTe) detector for low energy photon spectrometry was evaluated. Collected data were analyzed using the basic software package available with the CdTe detector system and the COLEGRAM code developed for photopeak deconvolution at LNHB/France. Several calibrated point sources were used to determine the energy versus efficiency curve. The efficiency curve was used in the determination of main X-ray intensities of (153)Sm and (177)Lu.

4.
Appl Radiat Isot ; 66(6-7): 981-7, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18346902

RESUMEN

Proficiency tests were applied to assess the performance of 74 nuclear medicine services in activity measurements of (131)I, (123)I, (99)Tc(m), (67)Ga and (201)Tl. These tests produced 913 data sets from comparison programmes promoted by the National Laboratory for Ionizing Radiation Metrology (LNMRI) from 1999 to 2006. The data were evaluated against acceptance criteria for accuracy and precision and assigned as Acceptable or Not acceptable accordingly. In addition, three other statistical parameters were used as complementary information for performance evaluation which related to normative requirements and to radionuclide calibrators. The results have shown a necessity to improve quality control procedures and unsatisfactory performances of radionuclide calibrators, which incorporate Geiger-Müller detectors.