Front Neurol ; 13: 951802, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36341102

RESUMEN

Background: Measurement of D-dimer in cerebrospinal fluid (CSF) allows insight into coagulation system activation in the central nervous system and can be utilized to monitor intracranial hemorrhage as well as acute phase processes beyond hemostasis in inflammatory and neoplastic diseases. So far, the measurability of D-dimer in low and very low concentrations in CSF was limited in conventional immunoassays. Novel high-sensitivity chemiluminescent immunoassays such as the luminescent oxygen channeling immunoassay (LOCI®) are getting increasingly available but have not been validated in CSF. The aim of this study was to investigate the accuracy and linearity of the LOCI® in assessing D-dimer in CSF. Methods: INNOVANCE LOCI hs D-dimer reagent cartridge was used for the measurement of D-dimer in CSF of patients with different neurological diseases. For the evaluation of linearity, dilution series were performed in a pooled CSF sample with the determination of intra-assay precision (CV, coefficient of variation) in 3 individual samples with 20 replicates. Furthermore, D-dimer concentrations measured by LOCI® were compared with the respective results of a routinely available clinical latex-enhanced immunoassay (HemosiIL D-Dimer HS 500). Results: Linear regression analysis of the LOCI® method revealed a r 2 of 1.00 (p < 0.001) with a regression coefficient B of 1.012 ± 0.003 (CI: 1.005-1.019, p < 0.001) and an intercept of -1.475 ± 1.309 (CI: -4.493 to 1.543); the median intra-assay CV was 0.69% (range: 0.68-0.75). In total, 185 CSF samples were measured by LOCI® technology, showing a mean concentration of 204.84 ± 2,214.93 ng/ml. D-dimer concentration between LOCI and latex-enhanced immunoassay differed by a factor of 10.6 ± 13.6 on average with a maximum deviation by a factor of 61.3; the maximum deviation was found at low concentrations. Conclusion: D-dimer in CSF of patients with neurological disease can be reliably measured by the LOCI® method with high linearity and accuracy at low concentrations.

2.
Clin Appl Thromb Hemost ; 25: 1076029619885184, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31773967

RESUMEN

Platelet function (PF) plays a pivotal role in both hemostasis and thrombosis, and manual light transmission aggregometry (LTA) is considered the standard of care for platelet function testing but is an error-prone and time-consuming procedure. We aimed to test the agreement regarding maximum aggregation (MA), velocity (VEL), and lag-phase (LagP) of platelet aggregation of the automated Sysmex CS-2100i analyzer (Siemens, Germany) against the APACT 4004 (Elitech, France) in samples derived from healthy participants and patients with hemostaseologic disorders. In total, 123 patient-derived samples were investigated, including 42 patients with acetylsalicylic acid and/or clopidogrel intake and 20 patients with other hemostaseologic disorders. Both MA and VEL showed good or excellent intermethod correlation. Agreement between the testing methods was only partially achieved, and values were indicative for a systematic bias to lower measurements below a threshold of 50% MA with the CS-2100i compared to the APACT 4004. All patients with impaired PF in the APACT 4004 were successfully identified with the CS-2100i, and reference values for automated LTA are provided. Conclusively, automated LTA with the CS-2100i is a highly standardized and reliable PF testing method and represents a decisive step in the simplification of platelet function testing in clinical routine.


Asunto(s)
Pruebas de Coagulación Sanguínea/métodos , Agregación Plaquetaria/genética , Pruebas de Función Plaquetaria/métodos , Femenino , Humanos , Masculino