Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
BMC Cardiovasc Disord ; 21(1): 239, 2021 05 12.
Artículo en Inglés | MEDLINE | ID: mdl-33980177

RESUMEN

BACKGROUND: Point-of-care cardiac ultrasound (cardiac POCUS) has potential to become a useful tool for improving cardiovascular care in Tanzania. We conducted a pilot program to train clinicians at peripheral health centers to obtain and interpret focused cardiac POCUS examinations using a hand-held portable device. METHODS: Over a 5-day period, didactic and experiential methods were used to train clinicians to conduct a pre-specified scanning protocol and recognize key pathologies. Pre- and post-training knowledge and post-training image acquisition competency were assessed. In their usual clinical practices, trainees then scanned patients with cardiovascular signs/symptoms, recorded a pre-specified set of images for each scan, and documented their interpretation as to presence or absence of key pathologies on a case report form. A cardiologist subsequently reviewed all images, graded them for image quality, and then documented their interpretation of key pathologies in a blinded fashion; the cardiologist interpretation was considered the gold standard. RESULTS: 8 trainees (6 Clinical Officers, 1 Assistant Medical Officer, and 1 Medical Doctor) initiated and completed the training. Trainees subsequently performed a total of 429 cardiac POCUS examinations in their clinical practices over a 9 week period. Stratified by trainee, the median percent of images that were of sufficient quality to be interpretable was 76.7% (range 18.0-94.2%). For five of eight trainees, 75% or more of images were interpretable. For detection of pre-specified key pathologies, kappa statistics for agreement between trainee and cardiologist ranged from - 0.03 (no agreement) for detection of pericardial effusion to 0.42 (moderate agreement) for detection of tricuspid valve regurgitation. Mean kappa values across the key pathologies varied by trainee from 0 (no agreement) to 0.32 (fair agreement). CONCLUSIONS: The 5-day training program was sufficient to train most clinicians to obtain basic cardiac images but not to accurately interpret them. Proficiency in image interpretation may require a more intensive training program.


Asunto(s)
Ecocardiografía , Educación Médica Continua , Cardiopatías/diagnóstico por imagen , Capacitación en Servicio , Pruebas en el Punto de Atención , Adulto , Competencia Clínica , Estudios de Factibilidad , Femenino , Humanos , Aprendizaje , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Evaluación de Programas y Proyectos de Salud , Reproducibilidad de los Resultados , Tanzanía
3.
Radiol Clin North Am ; 53(2): 287-96, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25726994

RESUMEN

In patients with stable chest pain, coronary CT angiography (CCTA) has demonstrated high accuracy in excluding coronary artery disease and CCTA findings carry prognostic significance for the occurrence of future cardiovascular events. Increasingly, CCTA has been adopted as a triage tool in patients with acute chest pain. In specific clinical scenarios, CCTA further represents a useful tool to exclude an ischemic etiology in patients with cardiac arrhythmias or newly diagnosed heart failure. Several novel techniques are currently being investigated which may extend the ability of CCTA to characterize and quantify coronary artery plaque and assess the hemodynamic significance of stenosis.


Asunto(s)
Angiografía Coronaria/métodos , Tomografía Computarizada por Rayos X/métodos , Síndrome Torácico Agudo/diagnóstico por imagen , Adulto , Anciano , Arritmias Cardíacas/diagnóstico por imagen , Niño , Angiografía Coronaria/economía , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Análisis Costo-Beneficio , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Pronóstico , Literatura de Revisión como Asunto , Síncope/diagnóstico por imagen , Tomografía Computarizada por Rayos X/economía
4.
Eur Radiol ; 25(3): 694-702, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25316059

RESUMEN

OBJECTIVES: To evaluate the effect of a computer-aided detection (CAD) algorithm for coronary CT angiography (cCTA) on the performance of readers with different experience levels. METHODS: We studied 50 patients (18 women, 58 ± 11 years) who had undergone cCTA and quantitative coronary angiography (QCA). Eight observers with varying experience levels evaluated all studies for ≥50 % coronary artery stenosis. After 3 months, the same observers re-evaluated all studies, this time guided by a CAD system. Their performance with and without the CAD system (sensitivity, specificity, positive predictive value and negative predictive value) was assessed using the Likelihood Ratio Χ(2) test both at the per-patient and per-vessel levels. RESULTS: The sensitivity of the CAD system alone for stenosis detection was 71 % per-vessel and 100 % per-patient. There were 54 false positive (FP) findings within 199 analyzed vessels, most of them associated with non-obstructive (<50 %) lesions. With CAD, one (out of three, 33 %) inexperienced reader's per-patient sensitivity and negative predictive value significantly improved from 79 % to 100 % (P = 0.046) and from 90 % to 100 % (P = 0.034), respectively. Other readers' performance indices showed no statistically significant change. CONCLUSIONS: Our results suggest that CAD can improve some inexperienced readers' sensitivity for diagnosing coronary artery stenosis at cCTA.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Algoritmos , Competencia Clínica/normas , Medios de Contraste , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
5.
Eur J Radiol ; 82(8): 1240-7, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23601293

RESUMEN

PURPOSE: To assess the influence of experience and training on the proficiency in coronary CT angiography (CCTA) interpretation of practitioners with different levels of experience. METHODS AND MATERIALS: Nine radiologist and cardiologist observers with varying prior CCTA experience ranging from novice to expert independently analyzed two case series of 50 catheter-correlated CCTA studies for coronary artery stenosis (0%, ≤49%, 50-74%, 75-99%, or 100%). Results of the first case series were unblinded and presented along with catheter angiography results to each reader before proceeding to the second series. Diagnostic accuracy on a per-segment basis was compared for all readers and both case series, respectively. RESULTS: Correlation coefficients between CCTA and catheter angiography initially ranged between good (r=0.87) and poor (r=0.26), depending on reader experience, and significantly (p<0.05) improved in the second case series (range: r=0.42 to r=0.91). Diagnostic accuracy was significantly (p<0.05) higher for more experienced readers (range: 96.5-97.8%) as compared to less experienced observers (range: 90.7-93.6%). After completion of the second case series for less experienced readers sensitivity and PPV significantly (p<0.05) improved (range: 62.7-67.8%/51.4-84.1%), but still remained significantly (p<0.05) lower as compared to more experienced observers (range: 89.8-93.3%/80.6-93.3%). CONCLUSION: The level of experience appears to be a strong determinant of proficiency in CCTA interpretation. Limited one-time training improves proficiency in novice readers, but not to clinically satisfactory levels.


Asunto(s)
Angiografía Coronaria/estadística & datos numéricos , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/epidemiología , Médicos/estadística & datos numéricos , Competencia Profesional/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Anciano , Escolaridad , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Prevalencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Acad Radiol ; 20(5): 554-9, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23465380

RESUMEN

PURPOSE: To determine whether coronary artery anomalies can be detected on noncontrast computed tomography (CT) coronary artery calcium scoring (CCS) studies. MATERIALS AND METHODS: A total of 126 patients (mean age 62 years; 35 women) underwent noncontrast CCS and contrast enhanced coronary CT angiography (cCTA). Thirty-three patients were diagnosed with a coronary anomaly on cCTA, whereas coronary anomalies were excluded in 93. Two observers (reader 1 [R1] and reader 2 [R2]), blinded to patient information independently evaluated each CCS study for: 1) visibility of coronary artery origins, 2) detection of coronary anomalies, and 3) benign or malignant (ie, interarterial) course. Using cCTA as the reference standard, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CCS studies for detecting coronary anomalies were calculated. RESULTS: Of the 33 coronary anomalies, 16 were benign and 17 malignant. Based on noncontrast CCS studies, R1 and R2 correctly identified the left main origin in 123/126 (97.6%) and 121/126 (96%) patients; the left anterior descending origin in 125/126 (99.2%) and 122/126 (96.8%); the circumflex origin in 120/126 (95.2%) and 105/126 (83.3%); and the right coronary artery origin in 117/126 (92.9%) and 103/126 (81.7%), respectively. R1 and R2 identified 34 and 27 coronary anomalies and classified 19 and 15 as malignant, respectively. Interobserver reproducibility for detection of coronary anomalies was good (k = 0.76). Interobserver agreement for detection of malignant variants was even stronger (k = 0.80). On average, coronary artery anomalies were diagnosed with 85.2% sensitivity, 96.4% specificity, 90.5% PPV, and 94.1% NPV on noncontrast CCS studies. CONCLUSION: Benign and malignant coronary artery anomalies can be detected with relatively high accuracy on noncontrast-enhanced CCS studies. CCS studies should be reviewed for signs of coronary artery anomalies in order to identify malignant variants with possible impact on patient management.


Asunto(s)
Calcinosis/diagnóstico por imagen , Calcinosis/epidemiología , Angiografía Coronaria/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/epidemiología , Comorbilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Prevalencia , Reproducibilidad de los Resultados , Medición de Riesgo , Sensibilidad y Especificidad , Método Simple Ciego , South Carolina/epidemiología , Tomografía Computarizada por Rayos X
7.
Radiology ; 265(2): 385-92, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22875799

RESUMEN

PURPOSE: To assess the efficacy of coronary computed tomographic (CT) angiography for therapeutic decision making in patients with high likelihood of coronary artery disease (CAD)-specifically the ability of coronary CT angiography to help differentiate patients without and patients with a need for revascularization and determine the appropriate revascularization procedure. MATERIALS AND METHODS: The study protocol was approved by institutional review board, with written informed consent from all patients. The study was conducted in compliance with HIPAA. One hundred eighty-five consecutive symptomatic patients (121 men; mean age, 59.4 years±9.7) with a positive single photon emission computed tomography (SPECT) myocardial perfusion study underwent coronary CT angiography and conventional cardiac angiography (hereafter, cardiac catheterization). The management strategy (conservative treatment vs revascularization) and revascularization procedure (percutaneous coronary intervention [PCI] vs coronary artery bypass graft surgery [CABG]) were prospectively selected on the basis of a combination of coronary CT angiography and SPECT. In addition, the authors calculated the accuracy, sensitivity, specificity, and negative and positive predictive values of coronary CT angiography in the detection of obstructive CAD and the selection of a revascularization strategy. Cardiac catheterization was used as the standard of reference. RESULTS: Of the 185 patients, 113 (61%) did not undergo revascularization and 42 (23%) were free of CAD. In 178 patients (96%), the same therapeutic strategy (conservative treatment vs revascularization) was chosen on the basis of coronary CT angiography and catheterization. All patients in need of revascularization were identified with coronary CT angiography. When revascularization was indicated, the same procedure (PCI vs CABG) was chosen in 66 of 72 patients (92%). CONCLUSION: In patients with high likelihood of CAD, the performance of coronary CT angiography in the differentiation of patients without and patients with a need for revascularization and the selection of a revascularization strategy was similar to that of cardiac catheterization; accordingly, coronary CT angiography has the potential to limit the number of patients without obstructive CAD who undergo cardiac catheterization and to inform decision making regarding revascularization.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Toma de Decisiones , Selección de Paciente , Tomografía Computarizada por Rayos X/métodos , Enfermedad de la Arteria Coronaria/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Cuidados Preoperatorios/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Radiology ; 260(2): 390-9, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21693660

RESUMEN

PURPOSE: To prospectively compare traditional filtered back projection (FBP) and iterative image reconstruction for the evaluation of heavily calcified arteries with coronary computed tomography (CT) angiography. MATERIALS AND METHODS: The study had institutional review board approval and was HIPAA compliant. Written informed consent was obtained from all patients. Fifty-five consecutive patients (35 men, 20 women; mean age, 58 years ± 12 [standard deviation]) with Agatston scores of at least 400 underwent coronary CT angiography and cardiac catheterization. Image data were reconstructed with both FBP and iterative reconstruction techniques with corresponding cardiac algorithms. Image noise and subjective image quality were compared. To objectively assess the effect of FBP and iterative reconstruction on blooming artifacts, volumes of circumscribed calcifications were measured with dedicated volume analysis software. FBP and iterative reconstruction series were independently evaluated for coronary artery stenosis greater than 50%, and their diagnostic accuracy was compared, with cardiac catheterization as the reference standard. Statistical analyses included paired t tests, Kruskal-Wallis analysis of variance, and a modified McNemar test. RESULTS: Image noise measured significantly lower (P = .011-.035) with iterative reconstruction instead of FBP. Image quality was rated significantly higher (P = .031 and .042) with iterative reconstruction series than with FBP. Calcification volumes measured significantly lower (P = .019 and .026) with iterative reconstruction (44.3 mm(3) ± 64.7 and 46.2 mm(3) ± 68.8) than with FBP (54.5 mm(3) ± 69.5 and 56.3 mm(3) ± 72.5). Iterative reconstruction significantly improved some measures of per-segment diagnostic accuracy of coronary CT angiography for the detection of significant stenosis compared with FBP (accuracy: 95.9% vs 91.8%, P = .0001; specificity: 95.8% vs 91.2%, P = .0001; positive predictive value: 76.9% vs 61.1%, P = .0001). CONCLUSION: Iterative reconstruction reduces image noise and blooming artifacts from calcifications, leading to improved diagnostic accuracy of coronary CT angiography in patients with heavily calcified coronary arteries.


Asunto(s)
Calcinosis/diagnóstico por imagen , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X , Análisis de Varianza , Artefactos , Distribución de Chi-Cuadrado , Medios de Contraste , Electrocardiografía , Femenino , Humanos , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad
9.
Acad Radiol ; 18(7): 858-65, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21669351

RESUMEN

RATIONALE AND OBJECTIVES: Coronary computed tomographic (CT) angiography has been shown to detect noncalcified coronary artery plaque. Depending on tissue composition, noncalcified plaque differs in CT attenuation from blood and epicardial fat. The aim of this study was to determine whether noncalcified plaque can be visually detected on non-contrast-enhanced CT calcium scoring studies. MATERIALS AND METHODS: A total of 106 patients (40 women; mean age, 59 years) who underwent coronary calcium scoring, coronary CT angiography, and quantitative catheter angiography were prospectively investigated. Two blinded observers independently reviewed calcium scoring studies for positive vascular remodeling and hypoattenuation within the vessel wall, suggestive of noncalcified plaque. Findings on calcium scoring studies were compared with those on coronary CT angiography and quantitative catheter angiography. RESULTS: The mean Agatston score was 515.8 ± 826.8. Overall interobserver agreement for the identification of noncalcified lesions was substantial (κ = 0.69). Observer 1 and observer 2 identified 21 and 17 patients, respectively, with 38 and 35 lesions suggestive of noncalcified plaque. Coronary CT angiography confirmed noncalcified plaque in 33 of 38 (86.8%; observer 1) and 31 of 35 (88.6%; observer 2) lesions. Thus, the overall positive predictive value for correct identification of noncalcified plaque on calcium scoring studies was 0.88, although overall sensitivity was low at 0.39. CONCLUSIONS: Noncalcified plaque can be visually detected on calcium scoring studies. Review of calcium scoring studies for features of noncalcified plaque may enhance the identification of patients with more active disease and higher cardiovascular risk.


Asunto(s)
Calcinosis/complicaciones , Calcinosis/diagnóstico por imagen , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Eur Radiol ; 21(9): 1895-903, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21533864

RESUMEN

OBJECTIVE: To prospectively compare the accuracy of coronary CT angiography (CCTA) and conventional coronary angiography (CCA) for stenosis detection using composite findings from both tests as an enhanced reference standard. METHODS: One hundred thirteen patients underwent CCTA and CCA. Per-segment and per-patient accuracy of CCTA compared with initial CCA interpretation were determined. Angiographers were then unblinded to the CCTA results and re-evaluation of the CCA studies was performed with knowledge of CCTA findings, which was used as an enhanced reference standard to compare the diagnostic accuracy of CCTA versus CCA. RESULTS: When using the enhanced reference standard instead of initial CCA interpretation, CCTA accuracy for identifying segments (patients) with ≥50% stenosis increased from 97.7% (96.5%) to 98.1% (98.2%), sensitivity from 90.5% (100%) to 90.8% (100%), and specificity from 98.4% (94.3%) to 98.9% (97.1%). CCTA identified six segments and two patients with stenoses ≥50% missed on initial CCA interpretation. Compared with the enhanced reference standard the accuracies of CCTA and of initial CCA interpretation were not different (p = 0.87). CONCLUSION: CCTA compares favourably with CCA for stenosis detection. Use of a composite reference standard combining findings from both tests can control for the effect of false-negative CCA results when evaluating the accuracy of CCTA.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Medios de Contraste , Estenosis Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Estándares de Referencia , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
11.
Eur Radiol ; 21(10): 2130-8, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21611758

RESUMEN

OBJECTIVES: To compare image noise, image quality and diagnostic accuracy of coronary CT angiography (cCTA) using a novel iterative reconstruction algorithm versus traditional filtered back projection (FBP) and to estimate the potential for radiation dose savings. METHODS: Sixty five consecutive patients (48 men; 59.3 ± 7.7 years) prospectively underwent cCTA and coronary catheter angiography (CCA). Full radiation dose data, using all projections, were reconstructed with FBP. To simulate image acquisition at half the radiation dose, 50% of the projections were discarded from the raw data. The resulting half-dose data were reconstructed with sinogram-affirmed iterative reconstruction (SAFIRE). Full-dose FBP and half-dose iterative reconstructions were compared with regard to image noise and image quality, and their respective accuracy for stenosis detection was compared against CCA. RESULTS: Compared with full-dose FBP, half-dose iterative reconstructions showed significantly (p = 0.001 - p = 0.025) lower image noise and slightly higher image quality. Iterative reconstruction improved the accuracy of stenosis detection compared with FBP (per-patient: accuracy 96.9% vs. 93.8%, sensitivity 100% vs. 100%, specificity 94.6% vs. 89.2%, NPV 100% vs. 100%, PPV 93.3% vs. 87.5%). CONCLUSIONS: Iterative reconstruction significantly reduces image noise without loss of diagnostic information and holds the potential for substantial radiation dose reduction from cCTA.


Asunto(s)
Angiografía Coronaria/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Algoritmos , Cateterismo , Constricción Patológica , Diagnóstico por Imagen , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
Acad Radiol ; 17(6): 727-34, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20363161

RESUMEN

RATIONALE AND OBJECTIVES: The aim of this study was to compare the reproducibility of bidimensional and volumetric quantification of epicardial adipose tissue (EAT) on cardiac computed tomography (CT) and evaluate their relationship with the extent of coronary artery disease (CAD). MATERIALS AND METHODS: Forty-five individuals underwent cardiac dual-source CT and conventional coronary angiography for suspicion of CAD. Nonenhanced images acquired to assess calcium score were used to quantify EAT. Coronary stenosis grading was performed on conventional coronary angiograms using Gensini scores. Two independent observers manually measured right ventricular EAT thickness at three different levels and in two different planes (four chamber and short axis) to obtain mean values. Additionally, EAT volume was automatically determined using a commercially available software tool. RESULTS: Conventional coronary angiography demonstrated nonstenotic coronary arteries in 22 subjects and significant coronary artery stenosis in 23. Significant correlations were observed between volumetric estimation of EAT and body mass index, coronary artery calcification, and Gensini score. On automatic volumetry, patients with significant coronary artery stenosis had significantly greater EAT volumes (154.58 +/- 58.91 mL) than those without significant CAD (120.94 +/- 81.85 mL) (P = .016). The manual bidimensional approach based on thickness measurements failed to show a significant difference between the two groups. Reproducibility and interobserver agreement for EAT quantification were higher when the automatic volumetric method was used (concordance-correlation coefficient, 0.96) compared to manual measurements (concordance-correlation coefficients, 0.37 for four-chamber EAT, 0.53 for short-axis EAT, and 0.58 for average EAT). CONCLUSIONS: For the quantification of EAT on cardiac CT, automated volumetry is more reproducible and correlates better with the extent of CAD than manual bidimensional measurements.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagenología Tridimensional/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto
13.
Eur Radiol ; 20(5): 1160-7, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-19890640

RESUMEN

OBJECTIVE: To evaluate the performance of a computer-aided algorithm for automated stenosis detection at coronary CT angiography (cCTA). METHODS: We investigated 59 patients (38 men, mean age 58 +/- 12 years) who underwent cCTA and quantitative coronary angiography (QCA). All cCTA data sets were analyzed using a software algorithm for automated, without human interaction, detection of coronary artery stenosis. The performance of the algorithm for detection of stenosis of 50% or more was compared with QCA. RESULTS: QCA revealed a total of 38 stenoses of 50% or more of which the algorithm correctly identified 28 (74%). Overall, the automated detection algorithm had 74%/100% sensitivity, 83%/65% specificity, 46%/58% positive predictive value, and 94%/100% negative predictive value for diagnosing stenosis of 50% or more on per-vessel/per-patient analysis, respectively. There were 33 false positive detection marks (average 0.56/patient), of which 19 were associated with stenotic lesions of less than 50% on QCA and 14 were not associated with an atherosclerotic surrogate. CONCLUSION: Compared with QCA, the automated detection algorithm evaluated has relatively high accuracy for diagnosing significant coronary artery stenosis at cCTA. If used as a second reader, the high negative predictive value may further enhance the confidence of excluding significant stenosis based on a normal or near-normal cCTA study.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Reconocimiento de Normas Patrones Automatizadas/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Programas Informáticos
14.
Eur Radiol ; 20(4): 855-61, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19862532

RESUMEN

OBJECTIVE: To investigate whether regional calcification patterns at CT coronary artery calcium scoring (CCS) correlate with stenosis and non-calcified plaque formation. METHODS: We studied 106 patients with quantitative catheter angiography (QCA), CCS, and coronary CT angiography (cCTA). CCS was determined globally and for each artery separately. The morphological pattern of each calcification was classified as calcified nodule, shell-like, or diffuse. cCTA studies were evaluated for non-calcified plaque. The global and regional CCS and the calcification pattern were correlated with stenosis >or=50% and non-calcified plaque. RESULTS: A total of 48/106 patients had stenosis >or=50% on QCA. There was weak correlation (r = 0.36) of the global CCS with stenosis. Correlation was stronger per vessel (r = 0.55-r = 0.67). Shell-like and diffuse calcifications were significantly (p = 0.0001) more frequently associated with >or=50% stenosis and non-calcified plaque (p = 0.04) than calcified nodules. CONCLUSION: As shown before, the global CCS does not correlate well with stenosis. However, regional calcium distribution and specific patterns of calcification are correlated with stenosis and non-calcified plaque. Thus, the specificity of CT calcium scoring for identifying individuals with obstructive disease could be improved by vessel-based rather than global quantification of calcium and by differentiating specific morphological patterns of calcification.


Asunto(s)
Algoritmos , Calcinosis/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto
15.
Eur J Radiol ; 73(3): 560-5, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19167178

RESUMEN

PURPOSE: To investigate the impact of right ventricle (RV) contrast attenuation on the accuracy of RV function analysis at cardiac CT performed for coronary imaging. MATERIALS AND METHODS: We analyzed multi-phase cardiac dual-source CT studies of 40 consecutive patients (mean age 60.9+/-12.3 years; 13 women) with normal valve function. Function analyses of both the right and left ventricle (RV and LV) were performed using dedicated post processing software and stroke volumes (SV) were computed for each ventricle. The accuracy of the RV-SV measurements was determined based upon comparison to LV-SV measurement. The level of contrast attenuation of the RV was recorded at three separate regions of interest-below the pulmonary valve, mid-ventricular, and inferior RV. The accuracy of RV function assessment was correlated with the level of attenuation using regression analyses. RESULTS: There was a statistically significant correlation between the accuracy of RV function assessment and the level of RV attenuation in the inferior RV (adjusted R(2)=73.1%, p<0.0001). When compared to LV-SV measurements, in studies with low RV attenuation (<175 HUs, n=19) the mean deviation of RV-SV from LV-SV was 29.0+/-10.8 ml (42.1+/-13.9%). In studies with high RV attenuation (> or =175 HUs, n=21) the mean deviation of RV-SV from LV-SV was significantly lower 6.9+/-10.5 ml (9.9+/-16.0%). CONCLUSION: The accuracy of RV function analysis is dependent on the level of contrast medium attenuation achieved in the inferior RV. There should be at least intermediate attenuation (>175 HUs) to enable accurate functional analysis. At low attenuation levels RV function parameters are prone to underestimation.


Asunto(s)
Medios de Contraste/farmacocinética , Enfermedad Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Función Ventricular Derecha , Adulto , Anciano , Anciano de 80 o más Años , Angiografía Coronaria , Enfermedad Coronaria/fisiopatología , Electrocardiografía , Femenino , Humanos , Yopamidol/farmacocinética , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Análisis de Regresión , Estudios Retrospectivos , Estadísticas no Paramétricas
16.
AJR Am J Roentgenol ; 193(2): 397-409, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19620436

RESUMEN

OBJECTIVE: The purpose of this article is to describe the current role of ECG-synchronized CT in the evaluation of patients with acute chest pain (triple rule-out) in the emergency department. We discuss clinical contexts of the chest pain algorithm, technical improvements that have enabled CT to attain its current role for this application, scan protocols and radiation considerations, the evidence base regarding diagnostic and prognostic performance, and initial data on the cost-effectiveness of this promising emerging test. CONCLUSION: Currently available evidence suggests that CT-based approaches with modern scan technology are safe, accurate, and potentially cost-saving, although large-scale clinical trials are needed to ascertain the precise role of CT in the evaluation of acute chest pain.


Asunto(s)
Dolor en el Pecho/diagnóstico por imagen , Electrocardiografía/métodos , Servicios Médicos de Urgencia/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Angiografía/métodos , Enfermedad Coronaria/diagnóstico , Análisis Costo-Beneficio , Diagnóstico Diferencial , Electrocardiografía/economía , Servicios Médicos de Urgencia/economía , Servicio de Urgencia en Hospital , Femenino , Humanos , Masculino , Persona de Mediana Edad , Embolia Pulmonar/diagnóstico , Años de Vida Ajustados por Calidad de Vida , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/economía
17.
Am J Cardiol ; 104(3): 318-26, 2009 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-19616661

RESUMEN

To evaluate the performance of dual-energy computed tomography (CT) for integrative imaging of the coronary artery morphology and the myocardial blood supply, 36 patients (15 women, mean age 57 +/- 11 years) with equivocal or incongruous single photon emission CT (SPECT) results were investigated by a single-contrast medium-enhanced, retrospectively electrocardiographic-gated dual-energy CT (DECT) scan with simultaneous acquisition of high and low x-ray spectra. Thirteen patients subsequently underwent invasive coronary angiography (ICA). The DECT data were used to reconstruct anatomic coronary CT angiographic images and to map the myocardial iodine distribution within the left ventricular myocardium. Two independent observers analyzed all DECT studies for stenosis and myocardial iodine defects. A segmental comparison was performed between the stress/rest SPECT perfusion defects and DECT iodine defects and between the ICA and coronary CT angiographic findings for stenosis. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were estimated, along with the kappa statistics. Overall, DECT had 92% sensitivity and 93% specificity, with 93% accuracy for detecting any type of myocardial perfusion defect seen on SPECT. Contrast defects at DECT correctly identified 85 (96%) of 89 fixed and 60 (88%) of 68 reversible myocardial perfusion defects. The interobserver agreement was very good (weighted kappa = 0.87). Compared with ICA, coronary CT angiography had 90% sensitivity, 94% specificity, and 93% accuracy for the detection of >50% stenosis. In conclusion, our initial experience suggests that DECT, as a single examination, might be promising for the integrative analysis of the coronary artery morphology and the myocardial blood supply and is in good agreement with ICA and SPECT.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico , Anciano , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X
18.
Ann Pharmacother ; 43(2): 259-67, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19193589

RESUMEN

BACKGROUND: Nonadherence to clopidogrel after drug-eluting stent (DES) placement is associated with in-stent thrombosis and adverse cardiac events. OBJECTIVE: To identify the incidence of and barriers associated with nonadherence to clopidogrel in patients receiving DES. METHODS: Patients who received a DES between March 1, 2004, and August 31, 2005, from a single academic medical center were eligible. Telephone interviews were conducted 6 or more months following discharge. Nonadherence was defined as premature discontinuation of or less than 80% adherence to clopidogrel. Patients were asked to identify barriers to adherence. Differences between adherent and nonadherent patients were analyzed using chi(2) and t-test analysis. RESULTS: Of the 674 patients identified, 257 (38%) participated. The nonadherence rate was 20%. The majority (58%) of nonadherent patients discontinued therapy prematurely. Patients identified the main reason for discontinuation as medical barriers (18.56%), including perceived adverse effects (9.28%). The incidence of rash was higher in patients who were nonadherent (12% vs 4%; p = 0.049). Overall, 49% of patients recalled receiving discharge counseling regarding adverse effects. A financial barrier was identified by 22 (42%) patients in the nonadherent and 73 (36%) in the adherent group, of whom 64% and 52%, respectively, reported having insurance coverage for medications. Adherent patients reported higher copays ($29.69 vs $18.14; p = 0.01). CONCLUSIONS: Prospective studies should be conducted to aid in identifying patients at risk for nonadherence and possible in-stent thrombosis in order to identify interventions to improve adherence.


Asunto(s)
Stents Liberadores de Fármacos , Cumplimiento de la Medicación/psicología , Inhibidores de Agregación Plaquetaria/uso terapéutico , Ticlopidina/análogos & derivados , Adulto , Aspirina/efectos adversos , Aspirina/uso terapéutico , Enfermedades Cardiovasculares/tratamiento farmacológico , Clopidogrel , Estudios de Cohortes , Stents Liberadores de Fármacos/efectos adversos , Exantema/inducido químicamente , Femenino , Humanos , Masculino , Inhibidores de Agregación Plaquetaria/economía , Ticlopidina/economía , Ticlopidina/uso terapéutico
19.
Eur J Radiol ; 68(3): 423-33, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19008064

RESUMEN

The introduction of coronary CT angiography (cCTA) has reinvigorated the debate whether management of patients with suspected coronary artery disease (CAD) should be primarily based on physiological versus anatomical testing. Anatomical testing (i.e., cCTA or invasive catheterization) enables direct visualization and grading of coronary artery stenoses but has shortcomings for gauging the hemodynamic significance of lesions for myocardial perfusion. Conversely, rest/stress myocardial perfusion imaging (MPI) has been extensively validated for assessing the clinical significance of CAD by demonstrating fixed or reversible perfusion defects but has only limited anatomical information. There is early evidence that contrast medium enhanced dual-energy cCTA (DECT) has potential for the comprehensive analysis of coronary artery morphology as well as changes in myocardial perfusion. DECT exploits the fact that tissues in the human body and iodine-based contrast media have unique absorption characteristics when penetrated with different X-ray energy levels, which enables mapping the iodine (and thus blood) distribution within the myocardium. The purpose of this communication is to describe the practical application of this emerging technology for the comprehensive diagnosis of coronary artery disease in the context of the currently used tomographic imaging modalities (cCTA, nuclear MPI, MR MPI).


Asunto(s)
Calcinosis/diagnóstico por imagen , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Sensibilidad y Especificidad
20.
Eur Radiol ; 18(11): 2414-24, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18523782

RESUMEN

We aimed to evaluate the feasibility of diagnosing coronary stenosis and myocardial ischemia with a single dual-energy CT (DECT) acquisition. Thirty-five patients underwent contrast-enhanced, ECG-gated DECT of the heart while independently operating the two tubes of a dual-source CT system at high- and low-energy X-ray spectra. From the same raw data, coronary CTA (cCTA) studies were reconstructed for stenosis detection, and the myocardial blood-pool was analyzed by determining the tissue iodine content. Two independent observers analyzed all studies for stenosis and myocardial blood-pool deficits. Results were correlated with SPECT, coronary catheterization and cCTA on a segmental basis. cCTA had 98% sensitivity, 88% specificity and 92% accuracy for detection of >50% stenosis. DECT detected myocardial ischemia with 84% sensitivity, 94% specificity and 92% accuracy. Our initial experience may warrant further exploration of DECT as a possibly feasible single imaging investigation for the comprehensive diagnosis of coronary stenosis and myocardial ischemia.


Asunto(s)
Algoritmos , Angiografía Coronaria/métodos , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/etiología , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA