Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Dent J (Basel) ; 11(6)2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37366667

RESUMEN

The success of implant-supported fixed complete dental prostheses (ISFCDPs) depends on multiple factors: some are related to the fixtures, such as fixture material, surface characteristics, positioning, and type of connection to prosthetic components; others are related to the prostheses, such as design and materials used. Zirconia is a material widely used in fixed prosthodontics, whether on natural teeth or on implants, with excellent results over time. Regarding the use of zirconia for ISFCDPs, the 2018 ITI Consensus Report stated that "implant-supported monolithic zirconia prostheses may be a future option with more supporting evidence". Since CAD/CAM technology and zirconia are being continuously innovated to achieve better results and performances over time, a narrative review of the literature seems necessary to focus research efforts towards effective and durable solutions for implant-supported, full-arch rehabilitations. The objective of the present narrative review was to search the literature for studies regarding the clinical performance of zirconia-based ISFCDPs. According to the results of this review, the use of zirconia for ISFCDPs showed good clinical outcomes, with high survival rates ranging from 88% to 100% and prosthetic complications that were restorable by the clinicians in most cases.

2.
Dent J (Basel) ; 11(5)2023 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-37232774

RESUMEN

The aim of the study was to evaluate the accuracy of zygomatic implant placement using customized bone-supported laser-sintered titanium templates. Pre-surgical computed tomography (CT) scans allowed to develop the ideal virtual planning for each patient. Direct metal laser-sintering was used to create the surgical guides for the implant placement. Post-operative CT scans were taken 6 months after surgery to assess any differences between the planned and placed zygomatic implants. Qualitative and quantitative three-dimensional analyses were performed with the software Slicer3D, recording linear and angular displacements after the surface registration of the planned and placed models of each implant. A total of 59 zygomatic implants were analyzed. Apical displacement showed a mean movement of 0.57 ± 0.49 mm on the X-axis, 1.1 ± 0.6 mm on the Y-axis, and 1.15 ± 0.69 mm on the Z-axis for the anterior implant, with a linear displacement of 0.51 ± 0.51 mm on the X-axis, 1.48 ± 0.9 mm on the Y-axis, and 1.34 ± 0.9 mm on the Z-axis for the posterior implant. The basal displacement showed a mean movement of 0.33 ± 0.25 mm on the X-axis, 0.66 ± 0.47 mm on the Y-axis, and 0.58 ± 0.4 mm on the Z-axis for the anterior implant, with a linear displacement of 0.39 ± 0.43 mm on the X-axis, 0.42 ± 0.35 mm on the Y-axis, and 0.66 ± 0.4 mm on the Z-axis for the posterior implant. The angular displacements recorded significative differences between the anterior implants (yaw: 0.56 ± 0.46°; pitch: 0.52 ± 0.45°; roll: 0.57 ± 0.44°) and posterior implants (yaw: 1.3 ± 0.8°; pitch: 1.3 ± 0.78°; roll: 1.28 ± 1.1°) (p < 0.05). Fully guided surgery showed good accuracy for zygomatic implant placement and it should be considered in the decision-making process.

3.
Clin Oral Investig ; 27(7): 3895-3905, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37041271

RESUMEN

OBJECTIVES: The present study aimed to analyze the behaviors of three intraoral scanners (IOSs): evaluating the interdistance and axial inclination discrepancies in full-arch scans, predictable errors were searched. MATERIALS AND METHODS: Six edentulous sample models with variable numbers of dental implants were used; reference data were obtained with a coordinate-measuring machine (CMM). Each IOS (i.e., Primescan, CS3600, and Trios3) performed 10 scans per model (180 total scans). The origin of each scan body was used as a reference point to measure interdistance lengths and axial inclinations. Precision and trueness of interdistance measurements and axial inclinations were evaluated to address error predictability. Bland-Altman analysis, followed by linear regression analysis and Friedman's test (plus Dunn's post hoc correction), was performed to evaluate the precision and trueness. RESULTS: Regarding interdistance, Primescan showed the best precision (mean ± SD: 0.047 ± 0.020 mm), while Trios3 underestimated the reference value more than the others (p < 0.001) and had the worst performance (mean ± SD: -0.079 ± 0.048 mm). Concerning the inclination angle, Primescan and Trios3 tended to overestimate angle values, while CS3600 underestimated them. Primescan had fewer inclination angle outliers, but it tended to add 0.4-0.6° to the measurements. CONCLUSIONS: IOSs showed predictable errors: they tended to overestimate or underestimate linear measurements and axial inclinations of scan bodies, one added 0.4-0.6° to the angle inclination values. In particular, they showed heteroscedasticity, a behavior probably related to the software or the device itself. CLINICAL SIGNIFICANCE: IOSs showed predictable errors that could affect clinical success. When performing a scan or choosing a scanner, clinicians should clearly know their behaviors.


Asunto(s)
Implantes Dentales , Imagenología Tridimensional , Técnica de Impresión Dental , Modelos Dentales , Diseño Asistido por Computadora
4.
Implant Dent ; 19(5): 400-8, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20881811

RESUMEN

OBJECTIVES: Ectodermal dysplasia (ED) is a congenital syndrome characterized chiefly by abnormalities of tissues of ectodermal origin, namely skin, nails, hair, and teeth. Dental treatment of patients with ED is necessary, because it affords the opportunity to develop normal forms of speech, chewing, swallowing, and normal facial support. Because there are few reports focusing on implants inserted in bone grafted in patients affected by ED. This is a retrospective study of 78 implants inserted in 8 patients to detect those variables acting on survival and crestal bone remodeling around the implant neck in such subjects. MATERIALS: Seventy-eight fixtures were analyzed. Several patient-related (age and gender), anatomical (maxilla and mandible, tooth site), implant (type, length, and diameter), surgical (sites and types of grafts), and prosthetic (type of loading and implant/crow ratio) variables were investigated. Implant failure and peri-implant bone resorption were considered as predictors of clinical outcome. Kaplan-Meier algorithm and Cox regression were then performed to detect those variables statistically associated with the clinical outcome. RESULTS: Implant length and diameter ranged from 11.5 to 18 mm and from 3.5 to 6.0 mm, respectively. Implants were inserted to replace 19 incisors, 19 cuspids, 21 premolars, and 19 molars. One implant was lost. On the contrary, implant' length, grafted sites, and type of loading have an impact on univariate analysis, but this datum was not confirmed by multivariate algorithm. CONCLUSION: The use of dental implants and bone grafts to orally rehabilitate patients affected by ED is a valuable service with no difference in the results compared with unaffected patients, at least in adults.


Asunto(s)
Trasplante Óseo , Implantes Dentales , Displasia Ectodérmica/cirugía , Adulto , Factores de Edad , Pérdida de Hueso Alveolar/etiología , Remodelación Ósea/fisiología , Coronas , Pilares Dentales , Arco Dental/cirugía , Diseño de Prótesis Dental , Fracaso de la Restauración Dental , Displasia Ectodérmica/rehabilitación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Mandíbula/cirugía , Maxilar/cirugía , Persona de Mediana Edad , Estudios Retrospectivos , Factores Sexuales , Análisis de Supervivencia , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA