1.
PLoS One ; 3(2): e1524, 2008 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-18253478

RESUMEN

BACKGROUND: Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB), immunofluorescent assay (IFA) or approved nucleic acid amplification test (NAAT)). When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result), repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. METHODOLOGY: Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. PRINCIPAL FINDINGS: Of 167,371 rapid tests conducted, 2589 (1.6%) were reactive: of these, 2417 (93%) had positive WB/IFA, 172 (7%) had negative or indeterminate WB/IFA. Of 89/172 (52%) persons with a repeat confirmatory test: 17 (19%) were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81%) were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative) (p<0.001) and having an initial oral fluid WB (vs. serum) (p<0.001). Persons who had male-female sex (vs. male-male sex) were at increased risk for not having a repeat test [adjusted OR 2.6, 95% CI (1.3, 4.9)]. CONCLUSIONS: Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for persons with discordant results. Because of the lower sensitivity of oral fluid WBs, confirmatory testing following a reactive rapid test should be conducted using serum or plasma, when possible.


Asunto(s)
Errores Diagnósticos , Infecciones por VIH/diagnóstico , Vigilancia de Productos Comercializados/métodos , Juego de Reactivos para Diagnóstico/normas , Western Blotting , Femenino , Técnica del Anticuerpo Fluorescente , Anticuerpos Anti-VIH/análisis , Anticuerpos Anti-VIH/sangre , Humanos , Masculino , Técnicas de Amplificación de Ácido Nucleico , Reproducibilidad de los Resultados
2.
AIDS ; 20(12): 1661-6, 2006 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-16868448

RESUMEN

OBJECTIVE: Post-marketing surveillance was conducted to monitor the performance of the OraQuick Advance rapid HIV-1/2 antibody test (OraQuick) on whole blood and oral fluid. DESIGN: Surveillance of routinely collected data on clients tested with OraQuick in 368 testing sites affiliated with 17 state and city health departments between 11 August 2004 and 30 June 2005. METHODS: For whole blood and oral fluid, we report the median (range) health department OraQuick specificity and positive predictive value (PPV), and the number of clients with discordant results (e.g. who had a reactive rapid test not confirmed positive by Western blot or indirect immunofluorescence). At one site with lower than expected oral-fluid specificity, we evaluated whether device expiration, manufacturing lot, operator practices, or device-storage or testing-area temperatures were associated with false-positive tests. RESULTS: During the surveillance period, 135 724 whole blood and 26 066 oral fluid rapid tests were conducted. The median health department whole blood OraQuick specificity was 99.98% (range: 99.73-100%) and PPV was 99.24% (range: 66.67-100%); the median oral fluid specificity was 99.89% (range: 99.44-100%) and PPV was 90.00% (range: 50.00-100%). A total of 124 discordant results were reported from 68 (0.05%) whole blood and 56 (0.22%) oral fluid rapid tests. The oral fluid specificity at the site with excess oral fluid false-positive tests was 98.7% (95% confidence interval: 98.18-99.11%). The increase in false-positive tests at that site was not associated with any specific device characteristic, operator procedure or temperature condition. CONCLUSION: The specificity of OraQuick performed on whole blood and oral fluid during post-marketing surveillance was compatible with the manufacturer's claim within the package insert. However, one site experienced lower than expected oral fluid specificity. Sites that observe that the specificity of OraQuick is lower than the range indicated in the package insert should notify the manufacturer and evaluate quality assurance procedures.


Asunto(s)
Serodiagnóstico del SIDA/métodos , Infecciones por VIH/diagnóstico , Vigilancia de Productos Comercializados/métodos , Juego de Reactivos para Diagnóstico , Saliva/virología , Adulto , Errores Diagnósticos , Reacciones Falso Positivas , Femenino , Anticuerpos Anti-VIH/análisis , Infecciones por VIH/inmunología , Seropositividad para VIH/diagnóstico , Seropositividad para VIH/inmunología , VIH-1/inmunología , VIH-2/inmunología , Humanos , Masculino , Valor Predictivo de las Pruebas , Saliva/inmunología , Sensibilidad y Especificidad , Temperatura