Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Intervalo de año de publicación
1.
Braz J Psychiatry ; 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38870426

RESUMEN

BACKGROUND: Panic disorder (PD) is a common disabling condition characterized by recurrent panic attacks. Emotional and behavioral impairments are associated with functional connectivity (FC) and network abnormalities. We used the whole brain FC, modular networks, and graph-theory analysis to investigate extensive network profiles in PD. METHOD: The functional MRI data from 82 PD and 97 controls were included. Intrinsic FC between each pair of 160 regions, 6 intra-networks, and 15 inter-networks were analyzed. The topological properties were explored. RESULTS: PD patients showed altered FCs within the right insula, between frontal cortex-posterior cingulate cortex (PCC), frontal cortex-cerebellum, and PCC-occipital cortex (corrected P values < 0.001). Lower connections within the Sensorimotor Network (SMN) and SMN-Occipital Network (OCN) were detected (P values < 0.05). Various decreased global and local network features were found in PD (P values < 0.05). In addition, significant correlations were found between PD symptoms and nodal efficiency (Ne) in the insula (r = -0.273, P = 0.016), and the FC of the intra-insula (r = -0.226, P = 0.041). CONCLUSIONS: PD patients present with abnormal functional brain networks, especially the decreased FC and Ne within insula, suggesting that dysfunction of information integration plays an important role in PD.

2.
Clinics (Sao Paulo) ; 72(10): 609-617, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29160423

RESUMEN

OBJECTIVES: No studies have compared monoaxial and polyaxial pedicle screws with regard to the von Mises stress of the instrumentation, intradiscal pressures of the adjacent segment and adjacent segment degeneration. METHODS: Short-segment monoaxial/polyaxial pedicle screw fixation techniques were compared using finite element methods, and the redistributed T11-L1 segment range of motion, largest maximal von Mises stress of the instrumentation, and intradiscal pressures of the adjacent segment under displacement loading were evaluated. Radiographic results of 230 patients with traumatic thoracolumbar fractures treated with these fixations were reviewed, and the sagittal Cobb's angle, vertebral body angle, anterior vertebral body height of the fractured vertebrae and adjacent segment degeneration were calculated and evaluated. RESULTS: The largest maximal values of the von Mises stress were 376.8 MPa for the pedicle screws in the short-segment monoaxial pedicle screw fixation model and 439.9 MPa for the rods in the intermediate monoaxial pedicle screw fixation model. The maximal intradiscal pressures of the upper adjacent segments were all greater than those of the lower adjacent segments. The maximal intradiscal pressures of the monoaxial pedicle screw fixation model were larger than those in the corresponding segments of the normal model. The radiographic results at the final follow-up evaluation showed that the mean loss of correction of the sagittal Cobb's angle, vertebral body angle and anterior vertebral body height were smallest in the intermediate monoaxial pedicle screw fixation group. Adjacent segment degeneration was less likely to be observed in the intermediate polyaxial pedicle screw fixation group but more likely to be observed in the intermediate monoaxial pedicle screw fixation group. CONCLUSION: Smaller von Mises stress in the pedicle screws and lower intradiscal pressure in the adjacent segment were observed in the polyaxial screw model than in the monoaxial pedicle screw fixation spine models. Fracture-level fixation could significantly correct kyphosis and reduce correction loss, and adjacent segment degeneration was less likely to be observed in the intermediate polyaxial pedicle screw fixation group.


Asunto(s)
Fijación Interna de Fracturas/instrumentación , Vértebras Lumbares/lesiones , Tornillos Pediculares , Fracturas de la Columna Vertebral/cirugía , Vértebras Torácicas/lesiones , Adulto , Análisis de Varianza , Fenómenos Biomecánicos , Diseño de Equipo , Femenino , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/fisiopatología , Masculino , Persona de Mediana Edad , Presión , Radiografía , Rango del Movimiento Articular , Reproducibilidad de los Resultados , Estudios Retrospectivos , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/fisiopatología , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/fisiopatología , Índices de Gravedad del Trauma , Resultado del Tratamiento
3.
Clinics ; Clinics;72(10): 609-617, Oct. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-890680

RESUMEN

OBJECTIVES: No studies have compared monoaxial and polyaxial pedicle screws with regard to the von Mises stress of the instrumentation, intradiscal pressures of the adjacent segment and adjacent segment degeneration. METHODS: Short-segment monoaxial/polyaxial pedicle screw fixation techniques were compared using finite element methods, and the redistributed T11-L1 segment range of motion, largest maximal von Mises stress of the instrumentation, and intradiscal pressures of the adjacent segment under displacement loading were evaluated. Radiographic results of 230 patients with traumatic thoracolumbar fractures treated with these fixations were reviewed, and the sagittal Cobb's angle, vertebral body angle, anterior vertebral body height of the fractured vertebrae and adjacent segment degeneration were calculated and evaluated. RESULTS: The largest maximal values of the von Mises stress were 376.8 MPa for the pedicle screws in the short-segment monoaxial pedicle screw fixation model and 439.9 MPa for the rods in the intermediate monoaxial pedicle screw fixation model. The maximal intradiscal pressures of the upper adjacent segments were all greater than those of the lower adjacent segments. The maximal intradiscal pressures of the monoaxial pedicle screw fixation model were larger than those in the corresponding segments of the normal model. The radiographic results at the final follow-up evaluation showed that the mean loss of correction of the sagittal Cobb's angle, vertebral body angle and anterior vertebral body height were smallest in the intermediate monoaxial pedicle screw fixation group. Adjacent segment degeneration was less likely to be observed in the intermediate polyaxial pedicle screw fixation group but more likely to be observed in the intermediate monoaxial pedicle screw fixation group. CONCLUSION: Smaller von Mises stress in the pedicle screws and lower intradiscal pressure in the adjacent segment were observed in the polyaxial screw model than in the monoaxial pedicle screw fixation spine models. Fracture-level fixation could significantly correct kyphosis and reduce correction loss, and adjacent segment degeneration was less likely to be observed in the intermediate polyaxial pedicle screw fixation group.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Vértebras Torácicas/lesiones , Fracturas de la Columna Vertebral/cirugía , Tornillos Pediculares , Fijación Interna de Fracturas/instrumentación , Vértebras Lumbares/lesiones , Presión , Vértebras Torácicas/fisiopatología , Vértebras Torácicas/diagnóstico por imagen , Fenómenos Biomecánicos , Radiografía , Índices de Gravedad del Trauma , Reproducibilidad de los Resultados , Estudios Retrospectivos , Análisis de Varianza , Rango del Movimiento Articular , Fracturas de la Columna Vertebral/fisiopatología , Fracturas de la Columna Vertebral/diagnóstico por imagen , Resultado del Tratamiento , Análisis de Elementos Finitos , Diseño de Equipo , Fijación Interna de Fracturas/métodos , Vértebras Lumbares/fisiopatología , Vértebras Lumbares/diagnóstico por imagen
5.
Rev. bras. pesqui. méd. biol ; Braz. j. med. biol. res;44(7): 618-623, July 2011. ilus
Artículo en Inglés | LILACS | ID: lil-595709

RESUMEN

Taurine has positive effects on bone metabolism. However, the effects of taurine on osteoblast apoptosis in vitro have not been reported. The aim of this study was to investigate the activity of taurine on apoptosis of mouse osteoblastic MC3T3-E1 cells. The data showed that 1, 5, 10, or 20 mM taurine resulted in 16.7, 34.2, 66.9, or 63.75 percent reduction of MC3T3-E1 cell apoptosis induced by the serum deprivation (serum-free α-MEM), respectively. Taurine (1, 5, or 10 mM) also reduced cytochrome c release and inhibited activation of caspase-3 and -9, which were measured using fluorogenic substrates for caspase-3/caspase-9, in serum-deprived MC3T3-E1 cells. Furthermore, taurine (10 mM) induced extracellular signal-regulated kinase (ERK) phosphorylation in MC3T3-E1 cells. Knockdown of the taurine transporter (TAUT) or treatment with the ERK-specific inhibitor PD98059 (10 μM) blocked the activation of ERK induced by taurine (10 mM) and abolished the anti-apoptotic effect of taurine (10 mM) in MC3T3-E1 cells. The present results demonstrate for the first time that taurine inhibits serum deprivation-induced osteoblast apoptosis via the TAUT/ERK signaling pathway.


Asunto(s)
Animales , Bovinos , Ratones , Apoptosis/efectos de los fármacos , Apoptosis/fisiología , Quinasas MAP Reguladas por Señal Extracelular/metabolismo , Glicoproteínas de Membrana/metabolismo , Proteínas de Transporte de Membrana/metabolismo , Osteoblastos/efectos de los fármacos , Taurina/farmacología , Análisis de Varianza , Caspasa 9/metabolismo , /metabolismo , Osteoblastos/metabolismo , ARN Mensajero/metabolismo
6.
Braz J Med Biol Res ; 44(7): 618-23, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21710101

RESUMEN

Taurine has positive effects on bone metabolism. However, the effects of taurine on osteoblast apoptosis in vitro have not been reported. The aim of this study was to investigate the activity of taurine on apoptosis of mouse osteoblastic MC3T3-E1 cells. The data showed that 1, 5, 10, or 20 mM taurine resulted in 16.7, 34.2, 66.9, or 63.75% reduction of MC3T3-E1 cell apoptosis induced by the serum deprivation (serum-free α-MEM), respectively. Taurine (1, 5, or 10 mM) also reduced cytochrome c release and inhibited activation of caspase-3 and -9, which were measured using fluorogenic substrates for caspase-3/caspase-9, in serum-deprived MC3T3-E1 cells. Furthermore, taurine (10 mM) induced extracellular signal-regulated kinase (ERK) phosphorylation in MC3T3-E1 cells. Knockdown of the taurine transporter (TAUT) or treatment with the ERK-specific inhibitor PD98059 (10 µM) blocked the activation of ERK induced by taurine (10 mM) and abolished the anti-apoptotic effect of taurine (10 mM) in MC3T3-E1 cells. The present results demonstrate for the first time that taurine inhibits serum deprivation-induced osteoblast apoptosis via the TAUT/ERK signaling pathway.


Asunto(s)
Apoptosis/efectos de los fármacos , Apoptosis/fisiología , Quinasas MAP Reguladas por Señal Extracelular/metabolismo , Glicoproteínas de Membrana/metabolismo , Proteínas de Transporte de Membrana/metabolismo , Osteoblastos/efectos de los fármacos , Taurina/farmacología , Células 3T3 , Análisis de Varianza , Animales , Caspasa 3/metabolismo , Caspasa 9/metabolismo , Bovinos , Ratones , Osteoblastos/metabolismo , ARN Mensajero/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA