Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Front Med (Lausanne) ; 9: 739197, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35492336

RESUMEN

Purpose: By reporting clinical characteristics and retinal image quality before and after refractive lens replacement surgery in early-onset high myopia (eoHM) patients presenting with partial cataract, we emphasized the need for an objective way to grade the severity of partial cataracts. Methods: This retrospective, consecutive case series included six Chinese patients (nine eyes). Analysis of previous medical records, visual acuity, optometry, retinal image quality, and axial length (AXL) before surgery and after surgery was performed. Results: Five females and one male (nine eyes) with a mean (± SD) age of 11.6 ± 7.9 years (range: 4-25 years) were included in this study. The preoperative spherical power ranged from -7.5 to -42 D. The mean follow-up time was 36 months (range: 24-48 months). Phacoemulsification was followed by in-the-bag implantation of intraocular lens. For patients who were under 6 years old, posterior capsulotomy + anterior vitrectomy were performed simultaneously. All surgeries were uneventful and no postoperative complications occurred during the entire follow-up period. All patients' uncorrected visual acuity improved by ≥2 lines postoperatively(Snellen acuity). LogMAR best-corrected visual acuity was improved at 24-month (P = 0.042) and endpoint (P = 0.046) follow-ups. Modulation transfer function cutoff frequency (MTFcutoff) and objective scatter index (OSI) was significantly improved at 12-month (P = 0.025, P = 0.038), 24-month (P = 0.005, P = 0.007) and endpoint (P = 0.005, P = 0.008) follow-ups. Postoperative AXL remained stable during 2-4 year follow-ups (P > 0.05). Conclusion: Refractive lens replacement surgery is safe and effective for improving functional vision in eoHM patients presenting with partial cataract. Retinal image quality could provide a useful and objective way to facilitate partial cataract severity evaluation and surgery decision making.

2.
Int J Ophthalmol ; 14(7): 1034-1040, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34282388

RESUMEN

AIM: To evaluate the peripheral arterial filling time (PAFT) and venous filling time (VFT) in eyes without known diseases that may influence filling process using ultra-widefield (UWF) fluorescein angiography (FA), and to review the peripheral retina fluorescence features. METHODS: A total of 30 eyes of 30 patients were retrospectively reviewed in this observational study. UWF-FA was performed using Optos 200Tx. PAFT and VFT was recorded. The interval between the arterial or venous filling completion and the previous photo was documented. The appearance of the far peripheral retina was described as either granular background fluorescence or mottled fluorescent band or vascular leakage. Terminal vascular patterns was described as loop pattern or branching pattern. Microvascular abnormalities such as arteriovenous shunting, vessels crossing the horizontal raphe, right angle vessels, terminal networks, capillary nonperfusion, drusen or microaneurysms were evaluated. RESULTS: The normal limits of PAFT was 3.397-8.984s and 4.399-11.753s for VFT. The appearance of the far peripheral retina, defined as granular background (63%), mottled fluorescence (20%), or vascular leakage (17%), was symmetrical between both eyes. Capillary nonperfusion (23%) and microaneurysms (40%) were more frequently found in eyes with loop pattern than in eyes with branching pattern. Other peripheral signs such as right-angle vessels (73%), and terminal networks (80%) were commonly seen on UWF-FA in the normal peripheral retina. CONCLUSION: The main courses of retinal artery and vein filling time are overlapping with each other on UWF-FA. Notably, the arterial filling process is completed in the arteriovenous phase rather than the traditionally named arterial phase. There are various manifestations in the peripheral retina of normal eyes.

3.
Curr Eye Res ; 46(9): 1406-1413, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33645355

RESUMEN

Purpose: To investigate the prevalence and clinical characteristics of myelinated retinal nerve fibre (MRNF) in a large teleophthalmology system.Methods: All records between January 2015 and December 2015 from Daheng Prust teleophthalmology system were reviewed by 2 ophthalmologists independently. MRNF was classified into continuous group and discontinuous group according to the relationship between MRNF patches and optic disc. The number, total area and location of MRNF patches were analysed. Concomitant ocular diseases were documented.Results: Out of 51469 subjects, MRNF was detected in 304 eyes of 263 subjects with a prevalence rate of 0.51 ± 7.1% per subject and 0.30 ± 5.4% per eye. Among 304 eyes with MRNF, 239 (78.6%) eyes were in continuous group and 65 (21.4%) eyes were in discontinuous group. Single MRNF patch was found in 249 (81.9%) eyes and multiple MRNF patches were found in 55 (18.1%) eyes. MRNF of small size was found in 150 (49.3%) eyes. The ratios of multiple MRNF patches and small-sized MRNF in the continuous group were significantly higher than those in the discontinuous group (P = .014 and P < .001). In continuous group, the MRNF patches were located most frequently in the superior region (68.6%) of the optic disc; In discontinuous group, the MRNF patches were located most frequently in the inferotemporal region (38.5%) of the retina. Epiretinal membrane (12 eyes, 3.9%) was the most common concomitant ocular disease.Conclusion: MRNF is uncommon in China. MRNF usually presents unilaterally and as a single small whitish patch that is connected with optic disc.


Asunto(s)
Oftalmología/métodos , Enfermedades de la Retina/epidemiología , Células Ganglionares de la Retina/patología , Telemedicina/métodos , Agudeza Visual , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , China/epidemiología , Estudios Transversales , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Fibras Nerviosas/patología , Disco Óptico/patología , Prevalencia , Enfermedades de la Retina/diagnóstico , Enfermedades de la Retina/fisiopatología , Estudios Retrospectivos , Adulto Joven
4.
Chin Med J (Engl) ; 133(19): 2308-2314, 2020 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-32868501

RESUMEN

BACKGROUND: In recent years, visual quality has been extensively investigated in various conditions. In this community-based population study, we analyzed the effects of aging, refraction, and Lens Opacification Classification System III (LOCSIII) score on retinal imaging quality in healthy Chinese adults. METHODS: This cross-sectional study was conducted on sub-group subjects from The Handan Eye Study between October 2012 and January 2013. Healthy subjects over 30-years-old with logarithm of the minimal angle of resolution (logMAR) best-corrected visual acuity (BCVA) less than 0 were included. Retinal image quality was measured by optical quality analysis system (OQAS) and recorded as modulation transfer function cutoff frequency (MTFcutoff), OQAS value (OV) 100%, OV20%, OV9%, Strehl ratio (SR), and objective scatter index (OSI). The correlation between age, spherical equivalent refraction (SE), LOCSIII score, and optical quality parameters were investigated by multivariate analysis. RESULTS: Among 1108 verified subjects, 690 subjects (1380 eyes) met the inclusion criteria. Their age ranged from 30 to 76 years, SE ranged from -4.75 to 2.75 D. They were divided into five age groups (30-39, 40-49, 50-59, 60-69, and ≥70 years) for further analysis. After multivariate analysis by mixed-effect linear model, SR (t =  -3.03, P = 0.002), OV20% (t = -2.39, P = 0.017), and OV9% (t = -3.16, P = 0.001) significantly decreased with the increasing age, whereas logMAR BCVA (t = 4.42, P < 0.001) and OSI (t = 4.46, P < 0.001) significantly increased with age. As SE increased, SR (t = 2.74, P = 0.01), OV20% (t = 2.31, P = 0.02), and OV9% (t = 2.79, P = 0.005) significantly elevated, and OSI (t = -3.38, P < 0.001) significantly decreased. With the increase in cortical opacity score, all optical quality parameters except for SR significantly decreased, including MTFcutoff (t = -2.78, P = 0.01), OV100% (t = -2.78, P = 0.005), OV20% (t = -2.60, P = 0.009), and OV9% (t = -2.05, P = 0.040). As posterior sub capsular opacity score increased, MTFcutoff (t = -2.40, P = 0.02) and OV100% (t = -2.40, P = 0.01) significantly decreased, while OSI (t = 7.56, P < 0.001) significantly increased. CONCLUSIONS: In healthy Chinese adult population, optical quality-related parameters significantly decrease with the increasing age, and OSI significantly increases with age. In normal BCVA subjects, optical quality is significantly impacted by cortical and posterior sub capsular opacity rather than by nuclear opacity.


Asunto(s)
Envejecimiento , Retina , Adulto , Anciano , China , Estudios Transversales , Humanos , Persona de Mediana Edad , Agudeza Visual
5.
Int J Ophthalmol ; 13(4): 625-631, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32399415

RESUMEN

AIM: To evaluate the intra-operator repeatability of time domain and swept-source Fourier domain anterior segment optical coherence tomography (AS-OCT), namely, Visante AS-OCT and Casia SS-1000 OCT, in measuring the preoperative parameters of implantable collamer lens (ICL) in myopic eyes, as well as the agreement between the two devices. METHODS: A total of 97 eyes from 49 myopes were investigated in this prospective case series study. The anterior chamber depth (ACD), angle-to-angle distance (ATA), pupil diameter (PD) and crystalline lens rise (CLR) in all subjects were measured for three times during one session by the same operator. The repeatability was evaluated using the within-subject standard deviation (Sw), repeatability limits and intraclass correlation coefficients (ICC). The agreement between the two systems was evaluated using the Bland-Altman plots and 95% limits of agreement (LoA). RESULTS: The repeatability limits of Visante AS-OCT in measuring ACD, ATA, PD and CLR were 0.099, 0.141, 0.304, and 0.079 mm, respectively. The repeatability limits of Casia SS-1000 OCT in measuring ACD, ATA, PD, and CLR were 0.105, 0.127, 0.357, and 0.082 mm, respectively. Excellent repeatability could be attained in both devices, with the ICC>0.8 for all the measured variables. The interdevice agreement was excellent (P>0.05) for ACD and ATA, but poor (P<0.05) for PD and CLR. CONCLUSION: Good repeatability can be attained by time domain and swept-source Fourier-domain OCT for all the measured variables. Moreover, interdevice agreement analysis suggests that interchangeable measurements between two devices can be achieved for ACD and ATA, but not for PD and CLR; but the differences in measurements were not clinically significant.

6.
Int J Ophthalmol ; 11(5): 791-796, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29862177

RESUMEN

AIM: To evaluate the ability of macular ganglion cell complex (GCC) thickness using Fourier domain optical coherence tomography (FD-OCT) to detect glaucoma in highly myopic eyes. METHODS: Cross-sectional study. A total of 114 participants, consecutively were enrolled. Macular GCC thickness and peripapillary retinal nerve fiber layer (RNFL) thickness were obtained with RTVue FD-OCT. Receiver operating characteristics curves were constructed for each measurement parameter, and areas under the curves (AUCs) were compared. RESULTS: Both the average GCC and average RNFL thickness showed negative correlations with axial length (rGCC=-0.404, P=0.001; rRNFL=-0.561, P<0.001). The largest AUCs from GCC, and RNFL parameters were 0.968 [global loss volume (GLV)], and 0.855 (average RNFL), respectively. GLV was significantly better for detecting high myopic glaucoma than average RNFL (P<0.001). CONCLUSION: Macular GCC thickness has higher diagnostic power than peripapillary RNFL thickness to discriminate glaucoma patients from non-glaucoma subjects in high myopia.

8.
Mol Med Rep ; 5(3): 610-8, 2012 03.
Artículo en Inglés | MEDLINE | ID: mdl-22159329

RESUMEN

Marine fungal metabolite 1386A is a newly identified small molecular compound extracted from the mangrove fungus 1386A in the South China Sea. Preliminary experiments have demonstrated its amazing cytotoxity to cancer cells, while the mechanism remains poorly understood. microRNAs (miRNAs) are a newly identified class of small regulatory RNAs which play an important role in gene regulation at the post-transcriptional level. They usually function as oncogenes or tumor suppressors and are related to drug sensitivity and resistance. We aimed to test the hypothesis that the potential antineoplastic compound, 1386A, alters the miRNA profile in MCF-7 and whether its unknown mechanism may be predicted by analysis of the altered miRNA profile. Cell proliferation was analyzed by MTT assay. The alteration of the miRNA expression profile of MCF-7 cells was investigated using advanced microarray technology. Silico analysis using TargetScan was used to predict the putative targeted transcripts encoding the dysregulated miRNAs. 1386A inhibited MCF-7 cell proliferation in a time- and dose-dependent manner (the IC50 value at 48 h was 17.1 µmol/l). 1386A (17.1 µmol/l) significantly altered the global miRNA expression profile of the MCF-7 cells at 48 h. Forty-five miRNAs were differentially expressed in MCF-7 cells. Target prediction suggested that these miRNAs potentially target many oncogenes and tumor-suppressor genes associated with cancer development, progression and metastasis. The promising antineoplastic compound marine fungal metabolite 1386A alters the miRNA profiles of MCF-7 breast cancer cells. Analyzing the alteration of the miRNA profile caused by this potential antineoplastic compound may help to predict the unknown mechanism of 1386A.


Asunto(s)
Antineoplásicos/farmacología , Hongos/metabolismo , Regulación Neoplásica de la Expresión Génica/efectos de los fármacos , MicroARNs/metabolismo , Antineoplásicos/química , Neoplasias de la Mama/metabolismo , Línea Celular Tumoral , Femenino , Humanos , Análisis por Micromatrices
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA