Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Funct Morphol Kinesiol ; 9(3)2024 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-39189217

RESUMEN

Firefighters have demanding jobs, requiring high levels of fitness in stressful situations for operational readiness, yet many firefighters are at an increased risk of developing cardiovascular disease (CVD). Diet is an important factor contributing to the development of CVD. The purpose of this study was to describe the dietary intake of firefighters and examine the associations between dietary intake and the CVD risk. Forty-six male career firefighters (age = 41.2 ± 11.2 years; BMI = 29.2 ± 4.1 kg/m2; body fat = 21.7 ± 6.1%) enrolled in a fitness-focused wellness program completed a health survey and a fitness assessment. The survey responses and fitness assessment were used to calculate the Framingham CVD Risk Score. Data were analyzed using R, the residual assumptions were verified, and the alpha level was set at 0.05. The results revealed that firefighters consume a standard American diet, with the overconsumption of meat and underconsumption of fruits and vegetables. The average CVD risk approached the upper limit of low risk. The results also indicate that meat servings and preparation fat affect the CVD risk (R2 = 0.21, p = 0.006). The outcomes of this study can inform investigations aimed at improving operational readiness and reducing the CVD risk in firefighters by implementing a holistic approach combining dietary interventions with physical training.

2.
Sports (Basel) ; 11(2)2023 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-36828327

RESUMEN

A mode-specific swimming protocol to assess maximal aerobic uptake (VO2maxsw) is vital to accurately evaluate swimming performance. A need exists for reliable and valid swimming protocols that assess VO2maxsw in a flume environment. The purpose was to assess: (a) reliability and (b) "performance" validity of a VO2maxsw flume protocol using the 457-m freestyle pool performance swim (PS) test as the criterion. Nineteen males (n = 9) and females (n = 10) (age, 28.5 ± 8.3 years.; height, 174.7 ± 8.2 cm; mass, 72.9 ± 12.5 kg; %body fat, 21.4 ± 5.9) performed two flume VO2maxsw tests (VO2maxswA and VO2maxswB) and one PS test [457 m (469.4 ± 94.7 s)]. For test-retest reliability (Trials A vs. B), moderately strong relationships were established for VO2maxsw (mL·kg-1·min-1)(r= 0.628, p = 0.002), O2pulse (mL O2·beat-1)(r = 0.502, p = 0.014), VEmax (L·min-1) (r = 0.671, p = 0.001), final test time (sec) (0.608, p = 0.004), and immediate post-test blood lactate (IPE (BLa)) (0.716, p = 0.001). For performance validity, moderately strong relationships (p < 0.05) were found between VO2maxswA (r =-0.648, p = 0.005), O2pulse (r= -0.623, p = 0.008), VEmax (r = -0.509 p = 0.037), and 457-m swim times. The swimming flume protocol examined is a reliable and valid assessment of VO2maxsw., and offers an alternative for military, open water, or those seeking complementary forms of training to improve swimming performance.

3.
Curr Sports Med Rep ; 21(8): 289-302, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-35946848

RESUMEN

ABSTRACT: The Exercise is Medicine On Campus (EIM-OC) program began in 2009 at Chatham University by Dr. Robert Sallis, Dr. Carena Winters, and ACSM leadership. The vision of EIM-OC is "to see all campus and community members across multiple disciplines discover, share, and adopt the principles of EIM that will help change the culture of physical activity and chronic disease prevention and management campus wide." Although EIM-OC maintains close track of programmatic details, such as the number of registered and recognized institutions, a comprehensive review of EIM-OC publications has not been previously reported. The purpose of this scoping review was to 1) identify and examine all peer-reviewed evidence of EIM-OC, including scholarly articles and published abstracts of presentations; 2) analyze the key themes of EIM-OC implementation and outcomes; and 3) identify gaps in the literature. The scoping review covered all peer-reviewed publications, including scholarly articles and published abstracts, from 2009 to December 2021. In total, 9 scholarly articles and 46 published abstracts were included in this review. The articles and abstracts covered a wide range of topics, including gold level (physical activity assessment and exercise referral), silver level (physical activity education), and bronze level (physical activity awareness and promotion) activities, as well as evaluation of EIM-OC programming. Now that EIM-OC programming is firmly established, we now call on campuses and leaders to strengthen their reporting of EIM-OC outcomes at all levels: gold, silver, and bronze. Publishing research evidence will strengthen EIM-OC programming and initiatives. Specifically, we encourage publishing scholarly articles and using broad means for increasing dissemination.


Asunto(s)
Ejercicio Físico , Promoción de la Salud , Enfermedad Crónica , Humanos , Universidades
4.
Artículo en Inglés | MEDLINE | ID: mdl-35805561

RESUMEN

Consistent differences between males and females have been shown in land-based measurements of anaerobic power and capacity. However, these differences have not been investigated for a tethered 30-s maximal swimming test (TST). The purpose of this study is to explore gender differences in land and pool-based assessments of anaerobic power (Fpeak) and capacity (Fmean), as well as the influence of body composition. Thirteen males and fifteen females completed land (Wingate (WAnT)) and pool-based (TST) measures of anaerobic power and capacity previously described in the literature. Additionally, the subjects completed assessments of body composition via air displacement plethysmography. The males produced higher force than the females for Fpeak (p < 0.001) and Fmean (p = 0.008) during the TST. However, linear regression analysis determined that lean mass significantly predicted Fpeak (p = 0.002) and Fmean (p < 0.001) during the TST, while gender was no longer significant (p = 0.694 and p = 0.136, respectively). In conclusion, increases in anaerobic power and capacity (Fpeak and Fmean) may be a function of increased lean mass in males and females, warranting future research on the impact of resistance training programs on force production and swimming performance.


Asunto(s)
Composición Corporal , Entrenamiento de Fuerza , Anaerobiosis , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Factores Sexuales , Natación
5.
J Strength Cond Res ; 33(5): 1208-1215, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31034459

RESUMEN

Nagle, EF, Nagai, T, Beethe, AZ, Lovalekar, MT, Zera, JN, Connaboy, C, Abt, JP, Beals, K, Nindl, BC, Robertson, RJ, and Lephart, SM. Reliability and validity of a pool-based maximal oxygen uptake test to examine high-intensity short-duration freestyle swimming performance. J Strength Cond Res 33(5): 1208-1215, 2019-A modality-specific swimming protocol to assess maximal oxygen uptake (V[Combining Dot Above]O2maxsw) is essential to accurately prescribe and monitor swimming conditioning programs. Consequently, there is a need for a reliable and valid graded intensity swimming pool test to accurately assess V[Combining Dot Above]O2maxsw using indirect calorimetry. The purpose of this study was to assess (a) reliability of an intensity self-regulated swimming pool test of V[Combining Dot Above]O2maxsw and (b) validity of a V[Combining Dot Above]O2maxsw test using performance swim (PS) time as the criterion. Twenty-nine men (n = 15) and women (n = 14) (age, 23 ± 6.4 years; body mass index, 23.5 ± 3.0 kg·m) performed 2 swimming pool V[Combining Dot Above]O2maxsw trials (V[Combining Dot Above]O2maxsw A and V[Combining Dot Above]O2maxsw B), and 2 PS tests (45.7 m [31.20 ± 4.5 seconds] and 182 m [159.2 ± 25.5 seconds]). For test-retest reliability (trials A vs. B), strong correlations (p < 0.05) were found for V[Combining Dot Above]O2maxsw (ml·kg·min) (r = 0.899), O2 pulse (ml O2·beat) (r = 0.833), and maximum expired ventilatory volume (L·min) (r = 0.785). For performance validity, moderately strong correlations (p < 0.05) were found between V[Combining Dot Above]O2maxsw A and 45.7-m (r = -0.543) and 182-m (r = -0.486) swim times. The self-regulated graded intensity swimming pool protocol examined presently is a reliable and valid test of V[Combining Dot Above]O2maxsw. Studies should consider the suitability of a V[Combining Dot Above]O2maxsw test for military personnel, clinical populations, and injured athletes.


Asunto(s)
Calorimetría Indirecta/métodos , Prueba de Esfuerzo/métodos , Consumo de Oxígeno , Natación/fisiología , Adolescente , Adulto , Rendimiento Atlético , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Ventilación Voluntaria Máxima , Reproducibilidad de los Resultados , Factores de Tiempo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA