Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Biosens Bioelectron ; 267: 116773, 2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39277920

RESUMEN

Prostate Imaging Reporting and Data System (PI-RADS) score, a reporting system of prostate MRI cases, has become a standard prostate cancer (PCa) screening method due to exceptional diagnosis performance. However, PI-RADS 3 lesions are an unmet medical need because PI-RADS provides diagnosis accuracy of only 30-40% at most, accompanied by a high false-positive rate. Here, we propose an explainable artificial intelligence (XAI) based PCa screening system integrating a highly sensitive dual-gate field-effect transistor (DGFET) based multi-marker biosensor for ambiguous lesions identification. This system produces interpretable results by analyzing sensing patterns of three urinary exosomal biomarkers, providing a possibility of an evidence-based prediction from clinicians. In our results, XAI-based PCa screening system showed a high accuracy with an AUC of 0.93 using 102 blinded samples with the non-invasive method. Remarkably, the PCa diagnosis accuracy of patients with PI-RADS 3 was more than twice that of conventional PI-RADS scoring. Our system also provided a reasonable explanation of its decision that TMEM256 biomarker is the leading factor for screening those with PI-RADS 3. Our study implies that XAI can facilitate informed decisions, guided by insights into the significance of visualized multi-biomarkers and clinical factors. The XAI-based sensor system can assist healthcare professionals in providing practical and evidence-based PCa diagnoses.

2.
J Robot Surg ; 18(1): 293, 2024 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-39068351

RESUMEN

Robot-assisted laparoscopic radical prostatectomy (RALP) has improved patient recovery, but achieving optimal functional outcomes remains a challenge, especially early urinary continence. The Modified Apical Dissection (MAD) technique has been suggested to improve early continence compared to conventional RALP. A comprehensive search of PubMed, Embase, and Cochrane Central databases was conducted to identify studies on MAD from inception to March 2024. The risk of bias was evaluated using the ROBINS-I tool. Primary outcomes assessed included urinary continence, positive surgical margin rate, biochemical recurrence rates, and complication rates. Out of 789 studies screened initially, we selected 8 studies that met our inclusion criteria. Our analysis showed that patients who underwent the MAD technique had a significantly higher likelihood of achieving early urinary continence compared to those undergoing conventional RALP at the initial follow-up (Odds Ratio [OR] = 4.0, 95% CI = 1.87-8.57). This advantage continued at 1 month (OR = 5.44, 95% CI = 2.98-9.92), 3 months (OR = 5.36, 95% CI = 2.26-12.71), and 6 months (OR = 5.18, 95% CI = 1.51-17.75), though no significant difference was noted at 12 months. There were no significant differences in positive surgical margin rate or biochemical recurrence rate between MAD and conventional RALP. The overall complication rate was 10.9% (95% CI = 8.10-14.06), with most complications being classified as minor (Clavien-Dindo I-II). In summary, our meta-analysis suggests that the MAD technique may lead to earlier recovery of urinary continence without compromising oncologic outcomes in patients undergoing RALP. While there are published studies on the outcomes of MAD, only a few have the appropriate design with a comparison group needed for meta-analysis and discussing various endpoints. More randomized controlled trials are necessary, but the current literature still lacks retrospective studies with comparison groups.


Asunto(s)
Laparoscopía , Prostatectomía , Neoplasias de la Próstata , Procedimientos Quirúrgicos Robotizados , Prostatectomía/métodos , Prostatectomía/efectos adversos , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Masculino , Laparoscopía/métodos , Laparoscopía/efectos adversos , Neoplasias de la Próstata/cirugía , Márgenes de Escisión , Incontinencia Urinaria/etiología , Incontinencia Urinaria/epidemiología , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Resultado del Tratamiento , Disección/métodos , Próstata/cirugía
3.
Investig Clin Urol ; 65(2): 165-172, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38454826

RESUMEN

PURPOSE: Erectile dysfunction (ED) is considered a microvascular disorder and serves as an indicator for the potential development of cardiovascular disease (CVD). Although left ventricular diastolic dysfunction (LVDD) reflects early myocardial damage caused by microvascular disorders, the association between ED and LVDD remains poorly elucidated. MATERIALS AND METHODS: A cross-sectional study was conducted on 123 patients with ED. They underwent RigiScan, and conventional echocardiography, and attempted International Index of Erectile Function (IIEF) questionnaire. ED severity was evaluated by measuring changes in the penile base circumference and duration of penile rigidity (≥70%) during erection. The early diastolic velocity of mitral inflow (E) and early diastolic velocity of the mitral annulus (e') were measured using echocardiography. The patients were grouped based on the presence of CVD. RESULTS: Among 123 patients, 29 had CVD and 94 did not. Patients with CVD exhibited more pronounced ED and more severe LVDD. Associations between increased penile circumference with echocardiographic parameters were more prominent in patients with CVD than in those without CVD (ΔTtop and e' wave, r=0.508 and r=0.282, respectively, p for interaction=0.033; ΔTbase and E/e' ratio, r=-0.338 and r=-0.293, respectively, p for interaction <0.001). In the multivariate linear regression, the increase of penile base circumference was an independent risk factor for LVDD (e', B=0.503; E/e' ratio, B=-1.416, respectively, p<0.001). CONCLUSIONS: ED severity correlated well with LV diastolic dysfunction, particularly in the presence of CVD. This study highlighted the potential role of ED assessment as early indicator of CVD development.


Asunto(s)
Enfermedades Cardiovasculares , Disfunción Eréctil , Disfunción Ventricular Izquierda , Masculino , Humanos , Disfunción Eréctil/complicaciones , Enfermedades Cardiovasculares/complicaciones , Estudios Transversales , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/diagnóstico por imagen , Factores de Riesgo
4.
Acta Biomater ; 125: 183-196, 2021 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-33652167

RESUMEN

Currently, there are no clinically available tissue adhesives that work effectively in the fluid-rich and highly dynamic environments of the human body, such as the urinary system. This is especially relevant to the management of vesico-vaginal fistula, and developing a high-performance tissue adhesive for this purpose could vastly expand urologists' surgical repertoire and dramatically reduce patient discomfort. Herein, we developed a water-immiscible mussel protein-based bioadhesive (imWIMBA) with significantly improved properties in all clinical respects, allowing it to achieve rapid and strong underwater adhesion with tunable rheological properties. We evaluated in vivo potential of imWIMBA for sealing thermally injured fistula tracts between the bladder and vagina. Importantly, the use of imWIMBA in the presence of prolonged bladder drainage resulted in perfect closure of the vesico-vaginal fistula in operated pigs. Thus, imWIMBA could be successfully used for many surgical applications and improve treatment efficacy when combined with conventional surgical methods. STATEMENT OF SIGNIFICANCE: Vesico-vaginal fistula (VVF) is an abnormal opening between the bladder and the vagina, which is a stigmatized disease in many developing countries. Leakage of urine into internal organs can induce serious complications and delay wound repair. Conventional VVF treatment requires skillful suturing to provide a tension-free and watertight closure. In addition, there is no clinically approved surgical glue that works in wet and highly dynamic environments such as the urinary system. In this work, for potential clinical VVF closure and regeneration, we developed an advanced immiscible mussel protein-based bioglue with fast, strong, wet adhesion and tunable rheological properties. This regenerative immiscible bioglue could be successfully used for sealing fistulas and further diverse surgical applications as an adjuvant for conventional suture methods.


Asunto(s)
Fístula Vesicovaginal , Animales , Femenino , Humanos , Proteínas , Porcinos
5.
Investig Clin Urol ; 59(6): 363-370, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30402568

RESUMEN

Purpose: The aim of this study is to describe the technique and to report early results of transperineal magnetic resonance imaging and ultrasonography (MRI-US) fusion biopsy. Materials and Methods: A total of 75 patients underwent MRI-US fusion transperineal biopsy. Targeted biopsy via MRI-US fusion imaging was carried out for cancer-suspicious lesions with additional systematic biopsy. Detection rates for overall and clinically significant prostate cancer (csPCa) were evaluated and compared between systematic and targeted biopsy. In addition, further investigation into the detection rate according to prostate imaging reporting and data system (PI-RADS) score was done. Results of repeat biopsies were also evaluated. Results: Overall cancer detection rate was 61.3% (46 patients) and the detection rate for csPCa was 42.7% (32 patients). Overall detection rates for systematic and targeted biopsy were 41.3% and 57.3% (p<0.05), respectively. Detection rates for csPCa were 26.7% and 41.3%, respectively (p<0.05). The cancer detection rates via MRI fusion target biopsy were 30.8% in PI-RADS 3, 62.1% in PI-RADS 4 and 89.4% in PI-RADS 5. Rates of csPCa missed by targeted biopsy and systematic biopsy were 0.0% and 25.0%, respectively. The cancer detection rate in repeat biopsies was 61.1% (11 among 18 patients) in which 55.5% of cancer suspected lesions were located in the anterior portion. Conclusions: Transperineal MRI-US fusion biopsy is useful for improving overall cancer detection rate and especially detection of csPCa. Transperineal MRI-US targeted biopsy show potential benefits to improve cancer detection rate in patients with high PI-RADS score, tumor located at the anterior portion and in repeat biopsies.


Asunto(s)
Endosonografía , Biopsia Guiada por Imagen/métodos , Imagen por Resonancia Magnética , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Anciano , Anciano de 80 o más Años , Reacciones Falso Negativas , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Imagen Multimodal , Perineo , Próstata/diagnóstico por imagen
6.
Investig Clin Urol ; 59(2): 98-105, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29520385

RESUMEN

Purpose: The purpose of this study was to evaluate the efficacy of narrow-band imaging (NBI) as a diagnostic tool for detecting bladder tumors during cystoscopy compared with white light cystoscopy (WLC). Materials and Methods: From December 2013 to June 2017, a randomized prospective study was conducted on 198 patients underwent transurethral resection of bladder tumor by a single surgeon. The patients were divided into two groups according to diagnostic method. In Group I, WLC only was performed. In Group II, NBI was additionally performed after WLC. We analyzed the rate of detection of bladder tumors as a primary endpoint. In addition, we evaluated rates of recurrence in each group. Results: There were no significant differences between the two groups in characteristics except hypertension. In the analysis of rates of detection, the probability of diagnosing cancer was 80.9% (114/141) in the WLC group, and the probability of diagnosing cancer using WLC in the NBI group was 85.5% (159/186). After switching from WLC to NBI for second-look cystoscopy in the NBI group, NBI was shown to detect additional tumors with a detection rate of 35.1% (13/37) from the perspective of the patients and 42.2% (27/64) from the perspective of the tumors. The 1-year recurrence-free rate was 72.2% in the WLC group and 85.2% in the NBI group (p=0.3). Conclusions: NBI had benefits for detecting tumors overlooked by WLC. Although the difference in the 1-year recurrence-free rate was not statistically significant, our results showed a trend for higher recurrence in the NBI group.


Asunto(s)
Cistectomía , Cistoscopía , Iluminación/métodos , Imagen de Banda Estrecha/métodos , Recurrencia Local de Neoplasia , Anciano , Cistectomía/efectos adversos , Cistectomía/métodos , Cistoscopía/instrumentación , Cistoscopía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Recurrencia Local de Neoplasia/prevención & control , Estadificación de Neoplasias , Evaluación de Resultado en la Atención de Salud , Neoplasias de la Vejiga Urinaria/diagnóstico , Neoplasias de la Vejiga Urinaria/patología , Neoplasias de la Vejiga Urinaria/cirugía
7.
Korean J Urol ; 56(6): 429-34, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26078839

RESUMEN

PURPOSE: This study was designed to estimate the value of a second transurethral resection of bladder tumor (TURBT) procedure in patients with initially diagnosed T1 high-grade bladder cancer. MATERIALS AND METHODS: Between August 2009 and January 2013, a total of 29 patients with T1 high-grade bladder cancer prospectively underwent a second TURBT procedure. Evaluation included the presence of previously undetected residual tumor, changes to histopathological staging or grading, and tumor location. Recurrence-free and progression-free survival curves were generated to compare the prognosis between the groups with and without residual lesions by use of the Kaplan-Meier method. RESULTS: Of 29 patients, 22 patients (75.9%) had residual disease after the second TURBT. Staging was as follows: no tumor, 7 (24.1%); Ta, 5 (17.2%); T1, 6 (20.7%); Tis, 6 (20.7%); Ta+Tis, 1 (3.4%); T1+Tis, 1 (3.4%); and ≥T2, 3 (10.3%). The muscle layer was included in the surgical specimen after the initial TURBT in 24 patients (82.7%). In three patients whose cancer was upstaged to pT2 after the second TURBT, the initial surgical specimen contained the muscle layer. In the group with residual lesions, the 3-year recurrence-free survival and 3-year progression-free survival rates were 50% and 66.9%, respectively, whereas these rates were 68.6% and 68.6%, respectively, in the group without residual lesions. This difference was not statistically significant. CONCLUSIONS: Initial TURBT does not seem to be enough to control T1 high-grade bladder cancer. Therefore, a routine second TURBT procedure should be recommended in patients with T1 high-grade bladder cancer to accomplish adequate tumor resection and to identify patients who may need to undergo prompt cystectomy.


Asunto(s)
Neoplasias de la Vejiga Urinaria/cirugía , Anciano , Anciano de 80 o más Años , Cistectomía/métodos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Invasividad Neoplásica , Estadificación de Neoplasias , Neoplasia Residual , Pronóstico , Estudios Prospectivos , Reoperación/métodos , Resultado del Tratamiento , Neoplasias de la Vejiga Urinaria/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA