Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Cureus ; 16(7): e64101, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39114185

RESUMEN

Ultra-hypofractionated radiotherapy (UHF RT) is revolutionizing the treatment approach for low- and intermediate-risk prostate cancer patients. This study reports the planning process of UHF RT utilizing the cone beam computed tomography (CBCT)-based online adaptive radiotherapy (OART) treatment with the Ethos system, focusing on a comparative analysis between OART and image-guided radiotherapy (IGRT) plans. We also assessed the pre-planning capabilities of the Ethos system against the CyberKnife (CK) (Accuray, Sunnyvale, CA) system. A 66-year-old patient, diagnosed with prostatic acinar adenocarcinoma confirmed via biopsy and presenting with elevated prostate-specific antigen (PSA) levels, underwent UHF OART treatment using the Ethos system. The planning encompassed delineating the gross target volume (GTV) as the prostate, while the clinical target volume (CTV) comprised the prostate and proximal seminal vesicle. The planning target volume (PTV) was derived from the CTV with a 5 mm external margin except for a 3 mm posterior margin. A simultaneous integrated boost (SIB) technique was employed, delivering 40 Gy in five fractions (8 Gy per fraction) to the gross tumor volume (GTV) and 36.25 Gy in five fractions (7.25 Gy per fraction) to the remaining part of the planning target volume (PTV), with treatments scheduled biweekly. We compared OART and IGRT plans and conducted a comparative analysis between Ethos planning and the CK system for pre-planning assessment. When comparing Ethos planning and CK plans, Ethos demonstrated slightly better target coverage and organ-at-risk (OAR) sparing. However, CK plans showed superior containment of low-dose spillage, particularly at 50% and 25% iso-doses, due to non-coplanar beam arrangements. Our results demonstrated that OART plans yielded superior target coverage and improved OAR sparing compared to IGRT plans. Notably, the entire OART process, from planning to delivery, was accomplished within 27 minutes. The Ethos OART system's ability to adapt to daily anatomical changes, efficient workflow, and superior OAR-sparing capabilities make it a promising option for prostate cancer treatment using UHF RT.

2.
Med Dosim ; 2024 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-39079802

RESUMEN

Automated planning has surged in popularity within external beam radiation therapy in recent times. Leveraging insights from previous clinical knowledge could enhance auto-planning quality. In this work, we evaluated the performance of Ethos automated planning with knowledge-based guidance, specifically using Rapidplan (RP). Seventy-four patients with head-and-neck (HN) cancer and 37 patients with prostate cancer were used to construct separate RP models. Additionally, 16 patients from each group (HN and prostate) were selected to assess the performance of Ethos auto-planning results. Initially, a template-based Ethos plan (Non-RP plan) was generated, followed by integrating the corresponding RP model's DVH estimates into the optimization process to generate another plan (RP plan). We compared the target coverage, OAR doses, and total monitor units between the non-RP and RP plans. Both RP and non-RP plans achieved comparable target coverage in HN and Prostate cases, with a negligible difference of less than 0.5% (p > 0.2). RP plans consistently demonstrated lower doses of OARs in both HN and prostate cases. Specifically, the mean doses of OARs were significantly reduced by 9% (p < 0.05). RP plans required slightly higher monitor units in both HN and prostate sites (p < 0.05), however, the plan generation time was almost similar (p > 0.07). The inclusion of the RP model reduced the OAR doses, particularly reducing the mean dose to critical organs compared to non-RP plans while maintaining similar target coverage. Our findings provide valuable insights for clinics adopting Ethos planning, potentially enhancing the auto-planning to operate optimally.

3.
Biomed Phys Eng Express ; 10(5)2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-38906125

RESUMEN

Purpose/Objective. Small-field measurement poses challenges. Although many high-resolution detectors are commercially available, the EPID for small-field dosimetry remains underexplored. This study aimed to evaluate the performance of EPID for small-field measurements and to derive tailored correction factors for precise small-field dosimetry verification.Material/Methods. Six high-resolution radiation detectors, including W2 and W1 plastic scintillators, Edge-detector, microSilicon, microDiamond and EPID were utilized. The output factors, depth doses and profiles, were measured for various beam energies (6 MV-FF, 6 MV-FFF, 10 MV-FF, and 10 MV-FFF) and field sizes (10 × 10 cm2, 5 × 5 cm2, 4 × 4 cm2, 3 × 3 cm2, 2 × 2 cm2, 1 × 1 cm2, 0.5 × 0.5 cm2) using a Varian Truebeam linear accelerator. During measurements, acrylic plates of appropriate depth were placed on the EPID, while a 3D water tank was used with five-point detectors. EPID measured data were compared with W2 plastic scintillator and measurements from other high-resolution detectors. The analysis included percentage deviations in output factors, differences in percentage for PDD and for the profiles, FWHM, maximum difference in the flat region, penumbra, and 1D gamma were analyzed. The output factor and depth dose ratios were fitted using exponential functions and fractional polynomial fitting in STATA 16.2, with W2 scintillator as reference, and corresponding formulae were obtained. The established correction factors were validated using two Truebeam machines.Results. When comparing EPID and W2-PSD across all field-sizes and energies, the deviation for output factors ranged from 1% to 15%. Depth doses, the percentage difference beyond dmax ranged from 1% to 19%. For profiles, maximum of 4% was observed in the 100%-80% region. The correction factor formulae were validated with two independent EPIDs and closely matched within 3%.Conclusion. EPID can effectively serve as small-field dosimetry verification tool with appropriate correction factors.


Asunto(s)
Aceleradores de Partículas , Radiometría , Radiometría/instrumentación , Radiometría/métodos , Aceleradores de Partículas/instrumentación , Diseño de Equipo , Fantasmas de Imagen , Calibración , Humanos , Conteo por Cintilación/instrumentación , Conteo por Cintilación/métodos , Reproducibilidad de los Resultados
4.
Biomed Phys Eng Express ; 10(4)2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38815562

RESUMEN

Purpose. This study aims to introduce an innovative noninvasive method that leverages a single image for both grading and staging prediction. The grade and the stage of cervix cancer (CC) are determined from diffusion-weighted imaging (DWI) in particular apparent diffusion coefficient (ADC) maps using deep convolutional neural networks (DCNN).Methods. datasets composed of 85 patients having annotated tumor stage (I, II, III, and IV), out of this, 66 were with grade (II and III) and the remaining patients with no reported grade were retrospectively collected. The study was IRB approved. For each patient, sagittal and axial slices containing the gross tumor volume (GTV) were extracted from ADC maps. These were computed using the mono exponential model from diffusion weighted images (b-values = 0, 100, 1000) that were acquired prior to radiotherapy treatment. Balanced training sets were created using the Synthetic Minority Oversampling Technique (SMOTE) and fed to the DCNN. EfficientNetB0 and EfficientNetB3 were transferred from the ImageNet application to binary and four-class classification tasks. Five-fold stratified cross validation was performed for the assessment of the networks. Multiple evaluation metrics were computed including the area under the receiver operating characteristic curve (AUC). Comparisons with Resnet50, Xception, and radiomic analysis were performed.Results. for grade prediction, EfficientNetB3 gave the best performance with AUC = 0.924. For stage prediction, EfficientNetB0 was the best with AUC = 0.931. The difference between both models was, however, small and not statistically significant EfficientNetB0-B3 outperformed ResNet50 (AUC = 0.71) and Xception (AUC = 0.89) in stage prediction, and demonstrated comparable results in grade classification, where AUCs of 0.89 and 0.90 were achieved by ResNet50 and Xception, respectively. DCNN outperformed radiomic analysis that gave AUC = 0.67 (grade) and AUC = 0.66 (stage).Conclusion.the prediction of CC grade and stage from ADC maps is feasible by adapting EfficientNet approaches to the medical context.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Clasificación del Tumor , Estadificación de Neoplasias , Redes Neurales de la Computación , Neoplasias del Cuello Uterino , Humanos , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/patología , Femenino , Imagen de Difusión por Resonancia Magnética/métodos , Estudios Retrospectivos , Persona de Mediana Edad , Procesamiento de Imagen Asistido por Computador/métodos , Curva ROC , Adulto , Algoritmos
5.
Phys Imaging Radiat Oncol ; 28: 100512, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38111501

RESUMEN

Background and purpose: Accurate CT numbers in Cone Beam CT (CBCT) are crucial for precise dose calculations in adaptive radiotherapy (ART). This study aimed to generate synthetic CT (sCT) from CBCT using deep learning (DL) models in head and neck (HN) radiotherapy. Materials and methods: A novel DL model, the 'self-attention-residual-UNet' (ResUNet), was developed for accurate sCT generation. ResUNet incorporates a self-attention mechanism in its long skip connections to enhance information transfer between the encoder and decoder. Data from 93 HN patients, each with planning CT (pCT) and first-day CBCT images were used. Model performance was evaluated using two DL approaches (non-adversarial and adversarial training) and two model types (2D axial only vs. 2.5D axial, sagittal, and coronal). ResUNet was compared with the traditional UNet through image quality assessment (Mean Absolute Error (MAE), Peak-Signal-to-Noise Ratio (PSNR), Structural Similarity Index (SSIM)) and dose calculation accuracy evaluation (DVH deviation and gamma evaluation (1 %/1mm)). Results: Image similarity evaluation results for the 2.5D-ResUNet and 2.5D-UNet models were: MAE: 46±7 HU vs. 51±9 HU, PSNR: 66.6±2.0 dB vs. 65.8±1.8 dB, and SSIM: 0.81±0.04 vs. 0.79±0.05. There were no significant differences in dose calculation accuracy between DL models. Both models demonstrated DVH deviation below 0.5 % and a gamma-pass-rate (1 %/1mm) exceeding 97 %. Conclusions: ResUNet enhanced CT number accuracy and image quality of sCT and outperformed UNet in sCT generation from CBCT. This method holds promise for generating precise sCT for HN ART.

6.
BMC Med Imaging ; 23(1): 197, 2023 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-38031032

RESUMEN

BACKGROUND: In recent years, there has been a growing trend towards utilizing Artificial Intelligence (AI) and machine learning techniques in medical imaging, including for the purpose of automating quality assurance. In this research, we aimed to develop and evaluate various deep learning-based approaches for automatic quality assurance of Magnetic Resonance (MR) images using the American College of Radiology (ACR) standards. METHODS: The study involved the development, optimization, and testing of custom convolutional neural network (CNN) models. Additionally, popular pre-trained models such as VGG16, VGG19, ResNet50, InceptionV3, EfficientNetB0, and EfficientNetB5 were trained and tested. The use of pre-trained models, particularly those trained on the ImageNet dataset, for transfer learning was also explored. Two-class classification models were employed for assessing spatial resolution and geometric distortion, while an approach classifying the image into 10 classes representing the number of visible spokes was used for the low contrast. RESULTS: Our results showed that deep learning-based methods can be effectively used for MR image quality assurance and can improve the performance of these models. The low contrast test was one of the most challenging tests within the ACR phantom. CONCLUSIONS: Overall, for geometric distortion and spatial resolution, all of the deep learning models tested produced prediction accuracy of 80% or higher. The study also revealed that training the models from scratch performed slightly better compared to transfer learning. For the low contrast, our investigation emphasized the adaptability and potential of deep learning models. The custom CNN models excelled in predicting the number of visible spokes, achieving commendable accuracy, recall, precision, and F1 scores.


Asunto(s)
Inteligencia Artificial , Aprendizaje Profundo , Humanos , Fantasmas de Imagen , Aprendizaje Automático , Imagen por Resonancia Magnética
7.
Biomed Phys Eng Express ; 9(5)2023 08 04.
Artículo en Inglés | MEDLINE | ID: mdl-37489854

RESUMEN

Purpose.To create a synthetic CT (sCT) from daily CBCT using either deep residual U-Net (DRUnet), or conditional generative adversarial network (cGAN) for adaptive radiotherapy planning (ART).Methods.First fraction CBCT and planning CT (pCT) were collected from 93 Head and Neck patients who underwent external beam radiotherapy. The dataset was divided into training, validation, and test sets of 58, 10 and 25 patients respectively. Three methods were used to generate sCT, 1. Nonlocal means patch based method was modified to include multiscale patches defining the multiscale patch based method (MPBM), 2. An encoder decoder 2D Unet with imbricated deep residual units was implemented, 3. DRUnet was integrated to the generator part of cGAN whereas a convolutional PatchGAN classifier was used as the discriminator. The accuracy of sCT was evaluated geometrically using Mean Absolute Error (MAE). Clinical Volumetric Modulated Arc Therapy (VMAT) plans were copied from pCT to registered CBCT and sCT and dosimetric analysis was performed by comparing Dose Volume Histogram (DVH) parameters of planning target volumes (PTVs) and organs at risk (OARs). Furthermore, 3D Gamma analysis (2%/2mm, global) between the dose on the sCT or CBCT and that on the pCT was performed.Results. The average MAE calculated between pCT and CBCT was 180.82 ± 27.37HU. Overall, all approaches significantly reduced the uncertainties in CBCT. Deep learning approaches outperformed patch-based methods with MAE = 67.88 ± 8.39HU (DRUnet) and MAE = 72.52 ± 8.43HU (cGAN) compared to MAE = 90.69 ± 14.3HU (MPBM). The percentages of DVH metric deviations were below 0.55% for PTVs and 1.17% for OARs using DRUnet. The average Gamma pass rate was 99.45 ± 1.86% for sCT generated using DRUnet.Conclusion.DL approaches outperformed MPBM. Specifically, DRUnet could be used for the generation of sCT with accurate intensities and realistic description of patient anatomy. This could be beneficial for CBCT based ART.


Asunto(s)
Aprendizaje Profundo , Neoplasias de Cabeza y Cuello , Tomografía Computarizada de Haz Cónico Espiral , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia
8.
Med Phys ; 50(12): 7891-7903, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37379068

RESUMEN

BACKGROUND: Automatic patient-specific quality assurance (PSQA) is recently explored using artificial intelligence approaches, and several studies reported the development of machine learning models for predicting the gamma pass rate (GPR) index only. PURPOSE: To develop a novel deep learning approach using a generative adversarial network (GAN) to predict the synthetic measured fluence. METHODS AND MATERIALS: A novel training method called "dual training," which involves the training of the encoder and decoder separately, was proposed and evaluated for cycle GAN (cycle-GAN) and conditional GAN (c-GAN). A total of 164 VMAT treatment plans, including 344 arcs (training data: 262, validation data: 30, and testing data: 52) from various treatment sites, were selected for prediction model development. For each patient, portal-dose-image-prediction fluence from TPS was used as input, and measured fluence from EPID was used as output/response for model training. Predicted GPR was derived by comparing the TPS fluence with the synthetic measured fluence generated by the DL models using gamma evaluation of criteria 2%/2 mm. The performance of dual training was compared against the traditional single-training approach. In addition, we also developed a separate classification model specifically designed to detect automatically three types of errors (rotational, translational, and MU-scale) in the synthetic EPID-measured fluence. RESULTS: Overall, the dual training improved the prediction accuracy of both cycle-GAN and c-GAN. Predicted GPR results of single training were within 3% for 71.2% and 78.8% of test cases for cycle-GAN and c-GAN, respectively. Moreover, similar results for dual training were 82.7% and 88.5% for cycle-GAN and c-GAN, respectively. The error detection model showed high classification accuracy (>98%) for detecting errors related to rotational and translational errors. However, it struggled to differentiate the fluences with "MU scale error" from "error-free" fluences. CONCLUSION: We developed a method to automatically generate the synthetic measured fluence and identify errors within them. The proposed dual training improved the PSQA prediction accuracy of both the GAN models, with c-GAN demonstrating superior performance over the cycle-GAN. Our results indicate that the c-GAN with dual training approach combined with error detection model, can accurately generate the synthetic measured fluence for VMAT PSQA and identify the errors. This approach has the potential to pave the way for virtual patient-specific QA of VMAT treatments.


Asunto(s)
Aprendizaje Profundo , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Inteligencia Artificial , Aprendizaje Automático , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica
9.
Biomed Phys Eng Express ; 8(6)2022 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-36130525

RESUMEN

Real-time tracking of a target volume is a promising solution for reducing the planning margins and both dosimetric and geometric uncertainties in the treatment of thoracic and upper-abdomen cancers. Respiratory motion prediction is an integral part of real-time tracking to compensate for the latency of tracking systems. The purpose of this work was to develop a novel method for accurate respiratory motion prediction using dual deep recurrent neural networks (RNNs). The respiratory motion data of 111 patients were used to train and evaluate the method. For each patient, two models (Network1 and Network2) were trained on 80% of the respiratory wave, and the remaining 20% was used for evaluation. The first network (Network 1) is a 'coarse resolution' prediction of future points and second network (Network 2) provides a 'fine resolution' prediction to interpolate between the future predictions. The performance of the method was tested using two types of RNN algorithms : Long Short-Term Memory (LSTM) and Gated Recurrent Unit (GRU). The accuracy of each model was evaluated using the root mean square error (RMSE) and mean absolute error (MAE). Overall, the RNN model with GRU- function had better accuracy than the RNN model with LSTM-function (RMSE (mm): 0.4 ± 0.2 versus 0.6 ± 0.3; MAE (mm): 0.4 ± 0.2 versus 0.6 ± 0.2). The GRU was able to predict the respiratory motion accurately (<1 mm) up to the latency period of 440 ms, and LSTM's accuracy was acceptable only up to 240 ms. The proposed method using GRU function can be used for respiratory-motion prediction up to a latency period of 440 ms.


Asunto(s)
Algoritmos , Redes Neurales de la Computación , Predicción , Humanos , Movimiento (Física) , Frecuencia Respiratoria
10.
J Med Phys ; 47(1): 40-49, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35548028

RESUMEN

Purpose: To fully exploit the benefits of magnetic resonance imaging (MRI) for radiotherapy, it is desirable to develop segmentation methods to delineate patients' MRI images fast and accurately. The purpose of this work is to develop a semi-automatic method to segment organs and tumor within the brain on standard T1- and T2-weighted MRI images. Methods and Materials: Twelve brain cancer patients were retrospectively included in this study, and a simple rigid registration was used to align all the images to the same spatial coordinates. Regions of interest were created for organs and tumor segmentations. The K-nearest neighbor (KNN) classification algorithm was used to characterize the knowledge of previous segmentations using 15 image features (T1 and T2 image intensity, 4 Gabor filtered images, 6 image gradients, and 3 Cartesian coordinates), and the trained models were used to predict organ and tumor contours. Dice similarity coefficient (DSC), normalized surface dice, sensitivity, specificity, and Hausdorff distance were used to evaluate the performance of segmentations. Results: Our semi-automatic segmentations matched with the ground truths closely. The mean DSC value was between 0.49 (optical chiasm) and 0.89 (right eye) for organ segmentations and was 0.87 for tumor segmentation. Overall performance of our method is comparable or superior to the previous work, and the accuracy of our semi-automatic segmentation is generally better for large volume objects. Conclusion: The proposed KNN method can accurately segment organs and tumor using standard brain MRI images, provides fast and accurate image processing and planning tools, and paves the way for clinical implementation of MRI-guided radiotherapy and adaptive radiotherapy.

11.
Med Phys ; 49(3): 1571-1584, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35094405

RESUMEN

PURPOSE: Magnetic resonance (MR) imaging is the gold standard in image-guided brachytherapy (IGBT) due to its superior soft-tissue contrast for target and organs-at-risk (OARs) delineation. Accurate and fast segmentation of MR images are very important for high-quality IGBT treatment planning. The purpose of this work is to implement and evaluate deep learning (DL) models for the automatic segmentation of targets and OARs in MR image-based high-dose-rate (HDR) brachytherapy for cervical cancer. METHODS: A 2D DL model using residual neural network architecture (ResNet50) was developed to contour the targets (gross tumor volume (GTV), high-risk clinical target volume (HR CTV), and intermediate-risk clinical target volume (IR CTV)) and OARs (bladder, rectum, sigmoid, and small intestine) automatically on axial MR slices of HDR brachytherapy patients. Furthermore, two additional 2D DL models using sagittal and coronal images were also developed. A 2.5D model was generated by combining the outputs from axial, sagittal, and coronal DL models. Similarly, a 2D and 2.5D DL models were also generated for the inception residual neural network (InceptionResNetv2 (InRN)) architecture. The geometric (Dice similarity coefficient (DSCs) and 95th percentile of Hausdorff distance (HD)) and dosimetric accuracy of 2D (axial only) and 2.5D (axial + sagittal + coronal) DL model generated contours were calculated and compared. RESULTS: The mean (range) DSCs of ResNet50 across all contours were 0.674 (0.05-0.96) and 0.715 (0.26-0.96) for the 2D and 2.5D models, respectively. For InRN, these were 0.676 (0.11-0.96) and 0.723 (0.35-0.97) for the 2D and 2.5D models, respectively. The mean HD of ResNet50 across all contours was 15.6 mm (1.8-69 mm) and 12.1 mm (1.7-44 mm) for the 2D and 2.5D models, respectively. The similar results for InRN were 15.4 mm (2-68 mm) and 10.3 mm (2.7-39 mm) for the 2D and 2.5D models, respectively. The dosimetric parameters (D90) of GTV and HR CTV for manually contoured plans matched better with the 2.5D model (p > 0.6) and the results from the 2D model were slightly lower (p < 0.08). On the other hand, the IR CTV doses (D90) for all of the models were slightly lower (2D: -1.3 to -1.5 Gy and 2.5D: -0.5 to -0.6 Gy) and the differences were statistically significant for the 2D model (2D: p < 0.000002 and 2.5D: p > 0.06). In case of OARs, the 2.5D model segmentations resulted in closer dosimetry than 2D models (2D: p = 0.07-0.91 and 2.5D: p = 0.16-1.0). CONCLUSIONS: The 2.5D DL models outperformed their respective 2D models for the automatic contouring of targets and OARs in MR image-based HDR brachytherapy for cervical cancer. The InceptionResNetv2 model performed slightly better than ResNet50.


Asunto(s)
Braquiterapia , Aprendizaje Profundo , Neoplasias del Cuello Uterino , Braquiterapia/métodos , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/radioterapia
12.
J Biomed Phys Eng ; 9(1): 17-28, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30881931

RESUMEN

BACKGROUND: The dosimetric parameters required in lung cancer radiation therapy are taken from a homogeneous water phantom; however, during treatment, the expected results are being affected because of its inhomogeneity. Therefore, it becomes necessary to quantify these deviations. OBJECTIVE: The present study has been undertaken to find out inter- and intra- lung density variations and its dosimetric impact on lung cancer radiotherapy using Monte Carlo code FLUKA and PBC algorithms. MATERIAL AND METHODS: Density of 100 lungs was recorded from their CT images along with age. Then, after PDD calculated by FLUKA MC Code and PBC algorithm for virtual phantom having density 0.2 gm/cm3 and 0.4 gm/cm3 (density range obtained from CT images of 100 lungs) using Co-60 10 x10 cm2 beams were compared. RESULTS: Average left and right lung densities were 0.275±0.387 and 0.270±0.383 respectively. The deviation in PBC calculated PDD were (+)216%, (+91%), (+)45%, (+)26.88%, (+)14%, (-)1%, (+)2%, (-)0.4%, (-)1%, (+)1%, (+)4%, (+)4.5% for 0.4 gm/cm3 and (+)311%, (+)177%, (+)118%, (+)90.95%, (+)72.23%, (+)55.83% ,(+)38.85%, (+)28.80%, (+)21.79%, (+)15.95%, (+)1.67%, (-) 2.13%, (+)1.27%, (+)0.35%, (-)1.79%, (-)2.75% for 0.2 gm/cm3 density mediums at depths of 1mm, 2mm, 3mm, 4mm, 5mm, 6 mm, 7 mm, 8mm, 9mm,10mm, 15mm, 30mm, 40mm, 50mm, 80mm and 100 mm, respectively. CONCLUSION: Large variations in inter- and intra- lung density were recorded. PBC overestimated the dose at air/lung interface as well as inside lung. The results of Monte Carlo simulation can be used to assess the performance of other treatment planning systems used in lung cancer radiotherapy.

13.
Phys Med Biol ; 64(8): 085016, 2019 04 12.
Artículo en Inglés | MEDLINE | ID: mdl-30884479

RESUMEN

Due to the complexity of advanced radiotherapy techniques, treatment planning process is usually time consuming and plan quality can vary considerably among planners and institutions. It is also impractical to generate all possible treatment plans based on available radiotherapy techniques and select the best option for a specific patient. Automatic dose prediction will be very helpful in these situations, while there were a few studies of three-dimensional (3D) dose prediction for patients who received radiotherapy. The purpose of this work was to develop a novel atlas-based method to predict 3D dose prediction and to evaluate its performance. Previously treated nineteen left-sided post-mastectomy breast cancer patients and sixteen prostate cancer patients were included in this study. One patient was arbitrarily chosen as the reference for each type of cancer and all the remaining patients' computed tomography (CT) images and contours were aligned to it using deformable image registration (DIR). Deformable vector field (DVF) for each patient i (DVF i-ref) was used to deform the original 3D dose matrix of that patient. CT scan of a test patient was also registered with the same reference patient using DIR and both direct DVF (DVFtest-ref) and inverse DVF ([Formula: see text]) were derived. Similarity of atlas patients to the test patient was determined based on the similarity of DVFtest-ref to atlas DVFs (DVF i-ref) and appropriate weighting factors were calculated. Patients' doses in the atlas were deformed again using [Formula: see text] to transform them from the reference patient's coordinates to the test patient's coordinates and the final 3D dose distribution for the test patient was predicted by summing the weighted individual 3D dose distributions. Performance of our method was evaluated and the results revealed that the proposed method was able to predict the 3D dose distributions accurately. The mean dose difference between clinical and predicted 3D dose distributions were 0.9 ± 1.1 Gy and 1.9 ± 1.2 Gy for breast and prostate plans. The proposed dose prediction method can be used to improve planning quality and facilitate plan comparisons.


Asunto(s)
Neoplasias de la Mama/radioterapia , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Femenino , Humanos , Masculino , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X/métodos
14.
J Cancer Res Ther ; 13(6): 994-999, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29237965

RESUMEN

PURPOSE: The aim of this work was to evaluate the various computed tomography (CT) techniques such as fast CT, slow CT, breath-hold (BH) CT, full-fan cone beam CT (FF-CBCT), half-fan CBCT (HF-CBCT), and average CT for delineation of internal target volume (ITV). In addition, these ITVs were compared against four-dimensional CT (4DCT) ITVs. MATERIALS AND METHODS: Three-dimensional target motion was simulated using dynamic thorax phantom with target insert of diameter 3 cm for ten respiration data. CT images were acquired using a commercially available multislice CT scanner, and the CBCT images were acquired using On-Board-Imager. Average CT was generated by averaging 10 phases of 4DCT. ITVs were delineated for each CT by contouring the volume of the target ball; 4DCT ITVs were generated by merging all 10 phases target volumes. Incase of BH-CT, ITV was derived by boolean of CT phases 0%, 50%, and fast CT target volumes. RESULTS: ITVs determined by all CT and CBCT scans were significantly smaller (P < 0.05) than the 4DCT ITV, whereas there was no significant difference between average CT and 4DCT ITVs (P = 0.17). Fast CT had the maximum deviation (-46.1% ± 20.9%) followed by slow CT (-34.3% ± 11.0%) and FF-CBCT scans (-26.3% ± 8.7%). However, HF-CBCT scans (-12.9% ± 4.4%) and BH-CT scans (-11.1% ± 8.5%) resulted in almost similar deviation. On the contrary, average CT had the least deviation (-4.7% ± 9.8%). CONCLUSIONS: When comparing with 4DCT, all the CT techniques underestimated ITV. In the absence of 4DCT, the HF-CBCT target volumes with appropriate margin may be a reasonable approach for defining the ITV.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada Cuatridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/fisiopatología , Movimiento (Física) , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Respiración
15.
J Med Phys ; 42(3): 101-115, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28974854

RESUMEN

Tumors in thoracic and upper abdomen regions such as lungs, liver, pancreas, esophagus, and breast move due to respiration. Respiration-induced motion introduces uncertainties in radiotherapy treatments of these sites and is regarded as a significant bottleneck in achieving highly conformal dose distributions. Recent developments in radiation therapy have resulted in (i) motion-encompassing, (ii) respiratory gating, and (iii) tracking methods for adapting the radiation beam aperture to account for the respiration-induced target motion. The purpose of this review is to discuss the magnitude, impact, and management of respiration-induced tumor motion.

16.
J Med Phys ; 42(2): 59-64, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28706350

RESUMEN

PURPOSE: With the advent of state-of-the-art treatment technologies, the use of small fields has increased, and dosimetry in small fields is highly challenging. In this study, the potential use of Varian electronic portal imaging device (EPID) for small field measurements was explored for 6 and 15 MV photon beams. MATERIALS AND METHODS: The output factors and profiles were measured for a range of jaw-collimated square field sizes starting from 0.8 cm × 0.8 cm to 10 cm × 10 cm using EPID. For evaluation purpose, reference data were acquired using Exradin A16 microionization chamber (0.007 cc) for output factors and stereotactic field diode for profile measurements in a radiation field analyzer. RESULTS: The output factors of EPID were in agreement with the reference data for field sizes down to 2 cm × 2 cm and for 2 cm × 2 cm; the difference in output factors was +2.06% for 6 MV and +1.56% for 15 MV. For the lowest field size studied (0.8 cm × 0.8 cm), the differences were maximum; +16% for 6 MV and +23% for 15 MV photon beam. EPID profiles of both energies were closely matching with reference profiles for field sizes down to 2 cm × 2 cm; however, penumbra and measured field size of EPID profiles were slightly lower compared to its counterpart. CONCLUSIONS: EPID is a viable option for profile and output factor measurements for field sizes down to 2 cm × 2 cm in the absence of appropriate small field dosimeters.

17.
Br J Radiol ; 89(1060): 20150870, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26916281

RESUMEN

OBJECTIVE: The purpose of this work was to evaluate the four-dimensional cone beam CT (4DCBCT) imaging with different gantry rotation speed. METHODS: All the 4DCBCT image acquisitions were carried out in Elekta XVI Symmetry™ system (Elekta AB, Stockholm, Sweden). A dynamic thorax phantom with tumour mimicking inserts of diameter 1, 2 and 3 cm was programmed to simulate the respiratory motion (4 s) of the target. 4DCBCT images were acquired with different gantry rotation speeds (36°, 50°, 75°, 100°, 150° and 200° min(-1)). Owing to the technical limitation of 4DCBCT system, average cone beam CT (CBCT) images derived from the 10 phases of 4DCBCT were used for the internal target volume (ITV) contouring. ITVs obtained from average CBCT were compared with the four-dimensional CT (4DCT). In addition, the image quality of 4DCBCT was also evaluated for various gantry rotation speeds using Catphan(®) 600 (The Phantom Laboratory Inc., Salem, NY). RESULTS: Compared to 4DCT, the average CBCT underestimated the ITV. The ITV deviation increased with increasing gantry speed (-10.8% vs -17.8% for 36° and 200° min(-1) in 3-cm target) and decreasing target size (-17.8% vs -26.8% for target diameter 3 and 1 cm in 200° min(-1)). Similarly, the image quality indicators such as spatial resolution, contrast-to-noise ratio and uniformity also degraded with increasing gantry rotation speed. CONCLUSION: The impact of gantry rotation speed has to be considered when using 4DCBCT for ITV definition. The phantom study demonstrated that 4DCBCT with slow gantry rotation showed better image quality and less ITV deviation. ADVANCES IN KNOWLEDGE: Usually, the gantry rotation period of Elekta 4DCBCT system is kept constant at 4 min (50° min(-1)) for acquisition, and any attempt of decreasing/increasing the acquisition duration requires careful investigation. In this study, the 4DCBCT images with different gantry rotation speed were evaluated.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Tomografía Computarizada Cuatridimensional/métodos , Humanos , Fantasmas de Imagen , Respiración , Rotación , Tórax
18.
Br J Radiol ; 88(1054): 20150425, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26226396

RESUMEN

OBJECTIVE: The aim of this work was to evaluate the quality of kilovoltage (kV) cone beam CT (CBCT) images acquired during arc delivery. METHODS: Arc plans were delivered on a Catphan(®) 600 phantom (The Phantom Laboratory Inc., Salem, NY), and kV CBCT images were acquired during the treatment. The megavoltage (MV) scatter effect on kV CBCT image quality was evaluated using parameters such as Hounsfield unit (HU) accuracy, spatial resolution, contrast-to-noise ratio (CNR) and spatial non-uniformity (SNU). These CBCT images were compared with reference scans acquired with the same acquisition parameters without MV "beam on". This evaluation was carried out for different photon beams (6 and 15 MV), arc types (half vs full arc), static field sizes (10 × 10 and 25 × 25 cm(2)) and source-to-imager distances (SID) (150 and 170 cm). RESULTS AND CONCLUSION: HU accuracy, CNR and SNU were considerably affected by MV scatter, and this effect was increased with increasing field size and decreasing photon energy, whereas the spatial resolution was almost unchanged. The MV scatter effect was observed to be more for full-rotation arc delivery than for half-arc delivery. In addition, increasing the SID resulted in decreased MV scatter effect and improved the image quality. ADVANCES IN KNOWLEDGE: Nowadays, volumetric modulated arc therapy (VMAT) is increasingly used in clinics, and this arc therapy enables us to acquire CBCT imaging simultaneously. But, the main issue of concurrent imaging is the "MV scatter" effect on CBCT imaging. This study aims to experimentally quantify the effect of MV scatter on CBCT image quality.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Algoritmos , Humanos
19.
J Med Phys ; 40(2): 68-73, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26170552

RESUMEN

The purpose of this study was to compare the dosimetric characteristics; such as beam output, symmetry and flatness between gated and non-gated electron beams. Dosimetric verification of gated delivery was carried for all electron beams available on Varian CL 2100CD medical linear accelerator. Measurements were conducted for three dose rates (100 MU/min, 300 MU/min and 600 MU/min) and two respiratory motions (breathing period of 4s and 8s). Real-time position management (RPM) system was used for the gated deliveries. Flatness and symmetry values were measured using Imatrixx 2D ion chamber array device and the beam output was measured using plane parallel ion chamber. These detector systems were placed over QUASAR motion platform which was programmed to simulate the respiratory motion of target. The dosimetric characteristics of gated deliveries were compared with non-gated deliveries. The flatness and symmetry of all the evaluated electron energies did not differ by more than 0.7 % with respect to corresponding non-gated deliveries. The beam output variation of gated electron beam was less than 0.6 % for all electron energies except for 16 MeV (1.4 %). Based on the results of this study, it can be concluded that Varian CL2100 CD is well suitable for gated delivery of non-dynamic electron beams.

20.
J Appl Clin Med Phys ; 14(3): 4103, 2013 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-23652244

RESUMEN

The purpose of this study was to evaluate the capabilities of DMLC to deliver the respiratory motion-synchronized dynamic IMRT (MS-IMRT) treatments under various dose rates. In order to create MS-IMRT plans, the DMLC leaf motions in dynamic IMRT plans of eight lung patients were synchronized with the respiratory motion of breathing period 4 sec and amplitude 2 cm (peak to peak) using an in-house developed leaf position modification program. The MS-IMRT plans were generated for the dose rates of 100 MU/min, 400 MU/min, and 600 MU/min. All the MS-IMRT plans were delivered in a medical linear accelerator, and the fluences were measured using a 2D ion chamber array, placed over a moving platform. The accuracy of MS-IMRT deliveries was evaluated with respect to static deliveries (no compensation for target motion) using gamma test. In addition, the fluences of gated delivery of 30% duty cycle and non- MS-IMRT deliveries were also measured and compared with static deliveries. The MS-IMRT was better in terms of dosimetric accuracy, compared to gated and non-MS-IMRT deliveries. The dosimetric accuracy was observed to be significantly better for 100 MU/min MS-IMRT. However, the use of high-dose rate in a MS-IMRT delivery introduced dose-rate modulation/beam hold-offs that affected the synchronization between the DMLC leaf motion and target motion. This resulted in more dose deviations in MS-IMRT deliveries at the dose rate of 600 MU/min.


Asunto(s)
Movimiento , Neoplasias/radioterapia , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Respiración , Humanos , Fantasmas de Imagen , Dosificación Radioterapéutica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA