Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ann Acad Med Singap ; 43(3): 160-5, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24714710

RESUMEN

INTRODUCTION: Liver biopsy is considered the definitive investigation in the diagnosis and management of liver disease. This study describes the experience of performing transjugular liver biopsy (TJLB) over the last 9 years in a local single centre. MATERIALS AND METHODS: A retrospective review of consecutive TJLB procedures performed at our institution was conducted. A total of 152 patients (74 males and 78 females), with a mean age of 47.4 years (range, 13 to 83 years) underwent a total of 154 TJLB procedures at our institution between March 2003 and November 2011. The principal indication for TJLB was severe coagulopathy in over 80% of patients. The technical success, number of passes, histological adequacy and complication rates were analysed. RESULTS: The procedural success rate was 98.7% (152 out of 154 procedures). Adequate material for diagnosis was obtained in 149 out of 152 (98.0%) technically successful procedures. There was procedure related morbidity in 8 patients (5.2%) of which all but one were self-limiting requiring no further intervention. We also performed hepatic venous pressure gradient (HVPG) measurements in 19% of patients at the time of TJLB. CONCLUSION: TJLB performed at our institution is a safe and reliable technique in patients in whom traditional percutaneous liver biopsy may be hazardous. TJLB has a high technical success rate as well as a high diagnostic yield with a low complication rate. TJLB also has the added benefit of performing HVPG, which is of increasing importance in management and prognostication of chronic liver disease.


Asunto(s)
Venas Yugulares , Hepatopatías/patología , Hígado/patología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biopsia/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
2.
EJNMMI Res ; 3(1): 56, 2013 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-23883566

RESUMEN

BACKGROUND: Yttrium-90 (90Y) positron emission tomography with integrated computed tomography (PET/CT) represents a technological leap from 90Y bremsstrahlung single-photon emission computed tomography with integrated computed tomography (SPECT/CT) by coincidence imaging of low abundance internal pair production. Encouraged by favorable early experiences, we implemented post-radioembolization 90Y PET/CT as an adjunct to 90Y bremsstrahlung SPECT/CT in diagnostic reporting. METHODS: This is a retrospective review of all paired 90Y PET/CT and 90Y bremsstrahlung SPECT/CT scans over a 1-year period. We compared image resolution, ability to confirm technical success, detection of non-target activity, and providing conclusive information about 90Y activity within targeted tumor vascular thrombosis. 90Y resin microspheres were used. 90Y PET/CT was performed on a conventional time-of-flight lutetium-yttrium-oxyorthosilicate scanner with minor modifications to acquisition and reconstruction parameters. Specific findings on 90Y PET/CT were corroborated by 90Y bremsstrahlung SPECT/CT, 99mTc macroaggregated albumin SPECT/CT, follow-up diagnostic imaging or review of clinical records. RESULTS: Diagnostic reporting recommendations were developed from our collective experience across 44 paired scans. Emphasis on the continuity of care improved overall diagnostic accuracy and reporting confidence of the operator. With proper technique, the presence of background noise did not pose a problem for diagnostic reporting. A counter-intuitive but effective technique of detecting non-target activity is proposed, based on the pattern of activity and its relation to underlying anatomy, instead of its visual intensity. In a sub-analysis of 23 patients with a median follow-up of 5.4 months, 90Y PET/CT consistently outperformed 90Y bremsstrahlung SPECT/CT in all aspects of qualitative analysis, including assessment for non-target activity and tumor vascular thrombosis. Parts of viscera closely adjacent to the liver remain challenging for non-target activity detection, compounded by a tendency for mis-registration. CONCLUSIONS: Adherence to proper diagnostic reporting technique and emphasis on continuity of care are vital to the clinical utility of post-radioembolization 90Y PET/CT. 90Y PET/CT is superior to 90Y bremsstrahlung SPECT/CT for the assessment of target and non-target activity.

3.
Emerg Radiol ; 18(2): 127-38, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20963462

RESUMEN

Multi-detector computed tomography (MDCT) scanner is available in most hospitals and is increasingly being used as the first line imaging in trauma and suspected cardiovascular emergencies, such as acute coronary syndrome, pulmonary artery thrombo-embolism, abdominal aortic aneurysm and acute haemorrhage (Ryan et al. Clin Radiol 60:599-607, 2005). A significant number of these patients are haemodynamically unstable and can rapidly progress into shock and death. Recognition of computed tomography (CT) signs of imminent cardiovascular decompensation will alert the clinical radiologist to the presence of shock. In this review, the imaging findings of cardiovascular emergencies in both acute traumatic and non-traumatic settings with associated signs of imminent decompensation will be described and illustrated.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Medicina de Emergencia , Tomografía Computarizada por Rayos X , Enfermedades Cardiovasculares/diagnóstico por imagen , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA