Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 25(6): e14276, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38414322

RESUMEN

PURPOSE: Patient-specific quality assurance (PSQA) for vertebra stereotactic body radiation therapy (SBRT) presents challenges due to highly modulated small fields with high-dose gradients between the target and spinal cord. This study aims to explore the use of the SRS MapCHECK® (SRSMC) for vertebra SBRT PSQA. METHODS: Twenty vertebra SBRT treatment plans including prescriptions 20 Gy/1 fraction and 24 Gy/2 fractions were selected for each of Millennium (M)-Multileaf Collimator (MLC), and high-definition (HD)-MLC. All 40 plans were measured using Gafchromic EBT3 film (film) and SRSMC, using the StereoPHAN phantom. Plan complexity was assessed using modulation complexity score (MCS), edge metric (EM) (mm-1), modulation factor (MU/cGy), and average leaf pair opening (ALPO) (mm) and its correlation with gamma-pass rate was investigated. The high dose gradient between the target and the spinal cord was analyzed for film and SRSMC and compared against the treatment planning system (TPS). Applying the methodology proposed by AAPM TG-218, action and tolerance values specific to the SRSMC for vertebra SBRT were determined for ß values ranging from 5 to 8. RESULTS: Film and SRSMC gamma-pass rates showed no correlation (p > 0.05). A moderate negative correlation (R = -0.57, p = 0.01) is present between EM and SRSMC 3%/1 mm gamma-pass rate for HD-MLC plans. Both film and SRSMC accurately measured high dose gradients between the target and the spinal cord (R2 > 0.86, p ≤ 0.05). Notably, dose-gradient of HD-MLC plans is 22% steeper and has a smaller standard deviation to M-MLC plans (p ≤ 0.05). Applying TG-218, the film tolerance limit was 96% with action limit 95% for 5%/1 mm (ß = 6) and for the SRSMC tolerance limit was 97% with an action limit of 96% for 4%/1 mm (ß = 6). CONCLUSION: Our findings suggest that universal TG-218 limits may not be suitable for vertebra SBRT PSQA. This study demonstrates that SRSMC is a viable tool for vertebra SBRT PSQA, supported by TG-218 implementation of process-based tolerance and action limits.


Asunto(s)
Órganos en Riesgo , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Garantía de la Calidad de Atención de Salud/normas , Órganos en Riesgo/efectos de la radiación , Neoplasias de la Columna Vertebral/cirugía , Neoplasias de la Columna Vertebral/radioterapia
2.
Jpn J Clin Oncol ; 52(3): 266-273, 2022 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-34958091

RESUMEN

OBJECTIVE: To propose and evaluate an active method for sparing the small bowel in the treatment field of cervical cancer brachytherapy by prone position procedure. METHODS: The prone position procedure consists of five steps: making bladder empty, prone-positioning a patient on belly board, making the small bowel move to abdomen, filling the bladder with Foley catheter and finally turning the patient into the supine position. The proposed method was applied for the treatment of seven cervical cancer patients. Its effectiveness was evaluated and a correlation between the patient characteristics and the volumetric dose reduction of small bowel was also investigated. Brachytherapy treatment plans were built before and after the proposed method, and their dose-volume histograms were compared for targets and organs-at-risk. In this comparison, all plans were normalized to satisfy the same D90% for high-risk clinical target volume. RESULTS: For the enrolled patients, the average dose of small bowel was significantly reduced from 75.2 ± 4.9 Gy before to 60.2 ± 4.0 Gy after the prone position procedure, while minor dosimetric changes were observed in rectum, sigmoid and bladder. The linear correlation to body mass index, thickness and width of abdominopelvic cavity and bladder volume were 76.2, 69.7, 28.8 and -36.3%, respectively. CONCLUSIONS: The application of prone position procedure could effectively lower the volumetric dose of the small bowel. The dose reduction in the small bowel had a strong correlation with the patient's obesity and abdominal thickness. This means the patients for whom the proposed method would be beneficial can be judiciously selected for safe brachytherapy.


Asunto(s)
Braquiterapia , Neoplasias del Cuello Uterino , Abdomen , Braquiterapia/métodos , Femenino , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Recto , Neoplasias del Cuello Uterino/radioterapia
3.
Med Phys ; 49(1): 52-69, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34796527

RESUMEN

PURPOSE: To design and manufacture a customized thoracic phantom slab utilizing the 3D printing process, also known as additive manufacturing, consisting of different tissue density materials. Here, we demonstrate the 3D-printed phantom's clinical feasibility for imaging and dosimetric verification of volumetric modulated arc radiotherapy (VMAT) plans for lung and spine stereotactic ablative body radiotherapy (SABR) through end-to-end dosimetric verification. METHODS: A customizable anthropomorphic phantom slab was designed using the CT dataset of a commercial phantom (adult female ATOM dosimetry phantom, CIRS Inc.). Material extrusion 3D printing was utilized to manufacture the phantom slab consisting of acrylonitrile butadiene styrene material for the lung and the associated lesion, polylactic acid (PLA) material for soft tissue and spinal cord, and both PLA and iron-reinforced PLA materials for bone. CT images were acquired for both the commercial phantom and 3D-printed phantom for HU comparison. VMAT plans were generated for spine and lung SABR scenarios and were delivered as per departmental SABR protocols using a Varian TrueBeam STx linear accelerator. End-to-end dosimetry was implemented with radiochromic films, analyzed with gamma criteria of 5% dose difference, and a distance-to-agreement of 1 mm, at a 10% low-dose threshold by comparing with calculated dose using the Acuros algorithm of the Eclipse treatment planning system (v15.6). RESULTS: 3D-printed phantom inserts were observed to produce HU ranging from -750 to 2100. The 3D-printed phantom slab was observed to achieve a similar range of HU from the commercial phantom including a mean HU of -760 for lung tissue, a mean HU of 50 for soft tissue, and a mean HU of 220 and 630 for low- and high-density bone, respectively. Film dosimetry results show 2D-gamma passing rates for lung SABR (internal and superior) and spine SABR (inferior and superior) over 98% and 90%, respectively. CONCLUSIONS: The end-to-end testing of VMAT plans for spine and lung SABR suggests the clinical feasibility of the 3D-printed phantom, consisting of different tissue density materials that emulate lung, soft tissue, and bone in kV imaging and megavoltage photon dosimetry. Further investigation of the proposed 3D printing techniques for manufacturability and reproducibility will enable the development of clinical 3D-printed phantoms in radiotherapy.


Asunto(s)
Densidad Ósea , Radioterapia de Intensidad Modulada , Femenino , Humanos , Pulmón/diagnóstico por imagen , Fantasmas de Imagen , Impresión Tridimensional , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Reproducibilidad de los Resultados
4.
Radiat Oncol ; 14(1): 213, 2019 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-31775825

RESUMEN

BACKGROUND: Accurate and standardized descriptions of organs at risk (OARs) are essential in radiation therapy for treatment planning and evaluation. Traditionally, physicians have contoured patient images manually, which, is time-consuming and subject to inter-observer variability. This study aims to a) investigate whether customized, deep-learning-based auto-segmentation could overcome the limitations of manual contouring and b) compare its performance against a typical, atlas-based auto-segmentation method organ structures in liver cancer. METHODS: On-contrast computer tomography image sets of 70 liver cancer patients were used, and four OARs (heart, liver, kidney, and stomach) were manually delineated by three experienced physicians as reference structures. Atlas and deep learning auto-segmentations were respectively performed with MIM Maestro 6.5 (MIM Software Inc., Cleveland, OH) and, with a deep convolution neural network (DCNN). The Hausdorff distance (HD) and, dice similarity coefficient (DSC), volume overlap error (VOE), and relative volume difference (RVD) were used to quantitatively evaluate the four different methods in the case of the reference set of the four OAR structures. RESULTS: The atlas-based method yielded the following average DSC and standard deviation values (SD) for the heart, liver, right kidney, left kidney, and stomach: 0.92 ± 0.04 (DSC ± SD), 0.93 ± 0.02, 0.86 ± 0.07, 0.85 ± 0.11, and 0.60 ± 0.13 respectively. The deep-learning-based method yielded corresponding values for the OARs of 0.94 ± 0.01, 0.93 ± 0.01, 0.88 ± 0.03, 0.86 ± 0.03, and 0.73 ± 0.09. The segmentation results show that the deep learning framework is superior to the atlas-based framwork except in the case of the liver. Specifically, in the case of the stomach, the DSC, VOE, and RVD showed a maximum difference of 21.67, 25.11, 28.80% respectively. CONCLUSIONS: In this study, we demonstrated that a deep learning framework could be used more effectively and efficiently compared to atlas-based auto-segmentation for most OARs in human liver cancer. Extended use of the deep-learning-based framework is anticipated for auto-segmentations of other body sites.


Asunto(s)
Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Anciano , Femenino , Humanos , Neoplasias Hepáticas/radioterapia , Masculino , Persona de Mediana Edad , Redes Neurales de la Computación , Variaciones Dependientes del Observador , Órganos en Riesgo , Radioterapia , Reproducibilidad de los Resultados , República de Corea , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA