Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Anal Chim Acta ; 1058: 70-79, 2019 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-30851855

RESUMEN

In this work, a high integrated water detection system comprised a miniaturized and high precision homemade colorimeter, a microfluidic analysis module and a wireless module was reported. A reagent reaction based on the ammonium molybdate spectrophotometric method was recorded for the estimation of phosphate in natural water. A laser self-modulating module of 880 nm was used as the radiation source. A microfluidic chip was employed to fit the colorimeter with an optimized micro flow path for low liquid consumption and high precision detection. The wireless module consisted of two parts, using ZigBee and GSM modules to realize short and remote displaying and controlling. Applying a novel optimized algorithm, a wide linear response was obtained ranging from 0.02 up to 9.5 mg L-1. The optimization of colorimeterare mainly in the core detection part, allowing an improvement of the detection limit, achieving a result of 0.009 mg L-1. A low reagent consumption of 0.004 mg ascorbic acid and 0.011 mg ammonium molybdate for per determination was attained. Experimental results have also shown that the system could maintain good stability among broad room temperature changing from 17 °C to 35 °C with less energy consumption. The miniaturized colorimeter-based water detection system opens new avenue for operating in remote distance to get high precision measurements of phosphate in natural water.

2.
Sensors (Basel) ; 18(3)2018 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-29518059

RESUMEN

Water quality detection plays an increasingly important role in environmental protection. In this work, a novel colorimeter based on the Beer-Lambert law was designed for chemical element detection in water with high precision and miniaturized structure. As an example, the colorimeter can detect phosphorus, which was accomplished in this article to evaluate the performance. Simultaneously, a modified algorithm was applied to extend the linear measurable range. The colorimeter encompassed a near infrared laser source, a microflow cell based on microfluidic technology and a light-sensitive detector, then Micro-Electro-Mechanical System (MEMS) processing technology was used to form a stable integrated structure. Experiments were performed based on the ammonium molybdate spectrophotometric method, including the preparation of phosphorus standard solution, reducing agent, chromogenic agent and color reaction. The device can obtain a wide linear response range (0.05 mg/L up to 7.60 mg/L), a wide reliable measuring range up to 10.16 mg/L after using a novel algorithm, and a low limit of detection (0.02 mg/L). The size of flow cell in this design is 18 mm × 2.0 mm × 800 µm, obtaining a low reagent consumption of 0.004 mg ascorbic acid and 0.011 mg ammonium molybdate per determination. Achieving these advantages of miniaturized volume, high precision and low cost, the design can also be used in automated in situ detection.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA