Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(1): 96-8, 2016 Jan.
Artículo en Chino | MEDLINE | ID: mdl-27228748

RESUMEN

Raman spectroscopy has been widely used for gas detection due to the advantages of simultaneous multiple species recognition, rapid analysis, and no sample preparation, etc. Low sensitivity is still a great limitation for Raman application. In this work a Raman system based on a hollow core optical fiber (HCOF) was built and the detection sensitivity for the gas was significantly improved. Also a comparison was carried out between the HCOF Raman system and back-scattering Raman system. The obtained results indicated that the HCOF Raman system could well enhance the signal while also for the background and noise. Using HCOF system, 60 folds signal enhancement was achieved with SNR improvement of 6 times for the N2 and O2 in air when comparing to the back-scattering system. While for the same signal intensity, with HCOF system the exposure time was well shortened to 1/60 and the noise was decreased to 1/2 than the back-scattering system.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(3): 645-8, 2015 Mar.
Artículo en Chino | MEDLINE | ID: mdl-26117872

RESUMEN

The detection of dissolved gases in seawater plays an important role in ocean observation and exploration. Raman spectroscopy has a great advantage in simultaneous multiple species detection and is thus regarded as a favorable choice for ocean application. However, its sensitivity remains insufficient, and a demand in enhancements is called! for before putting Raman spectroscopy to actual use in marine studies In this work, we developed a near-concentric cavity, in which laser beam could be trapped and reflected back and forth, for the purpose of intensifying Raman signals. The factors that would influence Raman signals were taken into account. The result show that the smaller angle between collection direction and optical axis of reflection mirror, the stronger the signal and signal to noise ratio (SNR) is. With a collection angle of 30 degrees, our Near-concentric Cavity System managed to raise the SNR to a figure about 16 times larger than that of common methods applying 90 degrees. Moreover, the alignment pattern in our system made it possible to excel concentric cavity with a 3 times larger SNR. Compared with the single-pass Raman signal, the signal intensity of our near-concentric cavity was up to 70 times enhanced. According to the obtained results of CO2 measurement, it can be seen that the new system provides a limit of detection(LOD) for CO2 about 0.19 mg x L(-1) using 3-σ criterion standard, and the LOD of 11.5 µg x L(-1) for CH4 was evaluated with the theoretical cross section values of CO2 and CH4.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA