1.
Int J Mol Sci ; 21(2)2020 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-31963895

RESUMEN

Ultraviolet treatment of titanium implants makes their surfaces hydrophilic and enhances osseointegration. However, the mechanism is not fully understood. This study hypothesizes that the recruitment of fibrinogen, a critical molecule for blood clot formation and wound healing, is influenced by the degrees of hydrophilicity/hydrophobicity of the implant surfaces. Computational fluid dynamics (CFD) implant models were created for fluid flow simulation. The hydrophilicity level was expressed by the contact angle between the implant surface and blood plasma, ranging from 5° (superhydrophilic), 30° (hydrophilic) to 50° and 70° (hydrophobic), and 100° (hydrorepellent). The mass of fibrinogen flowing into the implant interfacial zone (fibrinogen infiltration) increased in a time dependent manner, with a steeper slope for surfaces with greater hydrophilicity. The mass of blood plasma absorbed into the interfacial zone (blood plasma infiltration) was also promoted by the hydrophilic surfaces but it was rapid and non-time-dependent. There was no linear correlation between the fibrinogen infiltration rate and the blood plasma infiltration rate. These results suggest that hydrophilic implant surfaces promote both fibrinogen and blood plasma infiltration to their interface. However, the infiltration of the two components were not proportional, implying a selectively enhanced recruitment of fibrinogen by hydrophilic implant surfaces.


Asunto(s)
Implantes Dentales , Fibrinógeno/metabolismo , Plasma/química , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Modelos Biológicos , Simulación de Dinámica Molecular , Oseointegración , Propiedades de Superficie/efectos de la radiación , Titanio , Rayos Ultravioleta , Cicatrización de Heridas
2.
Biomed Eng Online ; 16(1): 57, 2017 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-28506222

RESUMEN

BACKGROUND: Intra-arterial chemotherapy (IAC) for oral cancer can deliver a higher concentration of anticancer agent into a tumor-feeding artery than intravenous systemic chemotherapy. However, distribution of anticancer agent into several branches of the external carotid artery (ECA) in IAC has not demonstrated sufficient treatment efficacy. To improve the effectiveness of IAC, the flow distribution of anticancer agent into the branches of the ECA in several IAC methods was investigated using computational fluid dynamics (CFD). METHODS: Patient-specific three-dimensional vessel models were created from CT images of 2 patients with tongue cancer. Catheter models were combined with the vessel models. Thirty-two models were generated with varying vertical and horizontal positions of the catheter tip. With the use of a zero-dimensional resistance model of the peripheral vessel network, conventional IAC and superselective IAC were simulated in 30 and 2 models, respectively. The flow distribution of anticancer agent into the branches of the ECA was investigated in 32 models. Additionally, the blood streamline was traced from the inlet of the common carotid artery toward each outlet to examine the flow of anticancer agent in all models, and the wall shear stress of the vessel was calculated for some models. RESULTS: The CFD simulations could be conducted within a reasonable computational time. In several models, the anticancer agent flowed into the target artery only when the catheter tip was located below the bifurcation of the ECA and each target artery. Furthermore, the anticancer agent tended to flow into the target artery when the catheter tip was shifted toward the target artery. In all ECA branches that had flow of anticancer agent, the blood streamlines to the target arteries contacted the catheter tip. Anticancer agent flowed into only the target artery in patients' models for superselective IAC. However, high wall shear stress was observed at the target artery in one patient's model. CONCLUSIONS: This CFD study showed that location of the catheter tip was important in controlling the anticancer agent in conventional IAC. The distribution rate of anticancer agent into the tumor-feeding artery tended to increase when the catheter tip was placed below and toward the target artery. Although superselective IAC can reliably supply anticancer agent to the target artery, high wall shear stress at the target artery can occur, depending on vessel geometry of the patient, which may cause serious complications during the treatment.


Asunto(s)
Antineoplásicos/administración & dosificación , Antineoplásicos/sangre , Velocidad del Flujo Sanguíneo , Arterias Carótidas/fisiopatología , Modelos Cardiovasculares , Neoplasias de la Lengua/tratamiento farmacológico , Neoplasias de la Lengua/fisiopatología , Antineoplásicos/farmacocinética , Simulación por Computador , Quimioterapia Asistida por Computador/métodos , Humanos , Hidrodinámica , Infusiones Intraarteriales , Reología/métodos , Neoplasias de la Lengua/patología
4.
Biomed Eng Online ; 15: 16, 2016 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-26846094

RESUMEN

BACKGROUND: Patient-specific modelling in clinical studies requires a realistic simulation to be performed within a reasonable computational time. The aim of this study was to develop simple but realistic outflow boundary conditions for patient-specific blood flow simulation which can be used to clarify the distribution of the anticancer agent in intra-arterial chemotherapy for oral cancer. METHODS: In this study, the boundary conditions are expressed as a zero dimension (0D) resistance model of the peripheral vessel network based on the fractal characteristics of branching arteries combined with knowledge of the circulatory system and the energy minimization principle. This resistance model was applied to four patient-specific blood flow simulations at the region where the common carotid artery bifurcates into the internal and external carotid arteries. RESULTS: Results of these simulations with the proposed boundary conditions were compared with the results of ultrasound measurements for the same patients. The pressure was found to be within the physiological range. The difference in velocity in the superficial temporal artery results in an error of 5.21 ± 0.78 % between the numerical results and the measurement data. CONCLUSIONS: The proposed outflow boundary conditions, therefore, constitute a simple resistance-based model and can be used for performing accurate simulations with commercial fluid dynamics software.


Asunto(s)
Circulación Sanguínea , Arteria Carótida Externa/fisiología , Modelos Biológicos , Arteria Carótida Externa/diagnóstico por imagen , Humanos , Modelación Específica para el Paciente , Tomografía Computarizada por Rayos X , Viscosidad
SELECCIÓN DE REFERENCIAS