Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Echocardiography ; 18(7): 553-7, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11737963

RESUMEN

UNLABELLED: Human studies have suggested that Doppler transesophageal echocardiography (TEE) can determine normal physiologic coronary blood flow (CBF) and alterations in CBF due to proximal flow-limiting stenoses. However, assessment of CBF by Doppler TEE has not been validated. To determine if true estimation of CBF could be obtained with Doppler TEE, seven mongrel dogs (weight range 28 kg-36 kg) were evaluated. Simultaneous CBF determinations by Doppler TEE and epicardial electromagnetic flow (EMF) and/or epicardial Doppler flow (EDF) probes were compared. Measurements were obtained at baseline and following varying degrees of proximal coronary occlusion, which produced reactive hyperemia. RESULTS: Consistent Doppler flow waveforms were obtainable by Doppler TEE in 34 different measurements during perturbations: Mean for TEE Flow (ml/min) = 85, EMF or EDF Flow (ml/min) = 53; Standard Deviation for TEE Flow (ml/min) = 45, EMF or EDF Flow (ml/min) = 38; Minimum for TEE Flow (ml/min) = 42, EMF or EDF Flow (ml/min) = 11; and Maximum for TEE Flow (ml/min) = 174, EMF or EDF Flow (ml/min) = 130. TEE Flow (ml/min) = 1.1 EMF/EDF flow + 26.3. There was a general trend towards overestimation of CBF by Doppler TEE. This study demonstrates that Doppler TEE is a promising method for obtaining measurements of CBF over the physiologic range.


Asunto(s)
Circulación Coronaria/fisiología , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Animales , Velocidad del Flujo Sanguíneo , Intervalos de Confianza , Perros , Modelos Lineales , Modelos Animales , Probabilidad , Valores de Referencia , Sensibilidad y Especificidad , Ultrasonografía Doppler/métodos
2.
ASAIO J ; 43(4): 321-5, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9242947

RESUMEN

Catheter placement by ultrasound may reduce radiation, improve positioning, and allow the use of echo contrast agents for diagnostic and therapeutic procedures. To evaluate its utility in the peripheral and coronary vascular beds, a preshaped 20 MHz Doppler catheter was inserted into the femoral artery for renal artery, or into the right carotid artery for left coronary artery cannulation in five dogs. Ultrasonic imaging of the vascular structure and catheter was provided by either transabdominal or transesophageal ultrasound. Using Doppler waveform polarity for retrograde guidance, the catheter was advanced to the region of the left renal or left coronary ostia. Ultrasonic emissions from the Doppler catheter were identified by color Doppler mode of the ultrasound machine and allowed the catheter tip to be identified within the beam width of the scanning transducer, providing the depth dimension. In the two animals in which left renal artery cannulation was attempted, the catheter was successfully manipulated into the ostium. In two of the three animals in which left coronary artery cannulation was attempted, the catheter was successfully manipulated into the ostium, followed by saline contrast injections revealing myocardial perfusion. In addition, in one animal, a Doppler flow wire was identified as it was advanced into the mid circumflex coronary. In conclusion, ultrasonically guided cannulation of aortic branches may be possible without x-ray, and this technique may lead to further use of ultrasound in diagnostic and therapeutic procedures.


Asunto(s)
Aorta Abdominal/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Cateterismo/métodos , Vasos Coronarios/diagnóstico por imagen , Arteria Renal/diagnóstico por imagen , Animales , Cateterismo Cardíaco/normas , Arterias Carótidas , Cateterismo/normas , Perros , Ecocardiografía Transesofágica , Arteria Femoral , Control de Calidad , Ultrasonografía Doppler en Color
3.
Circulation ; 95(5): 1328-34, 1997 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-9054867

RESUMEN

BACKGROUND: Although cardiac myocytes and coronary vascular endothelium are known to express a constitutive form of NO synthase, the in vivo effects of tonic endogenous production of NO on myocardial O2 consumption and contractile performance remain unclear. METHODS AND RESULTS: The effects of blockade of NO synthase were determined in intact dogs. Myocardial O2 consumption decreased systematically over a wide range of hemodynamic demand after the systemic administration of N omega-nitro-L-arginine methyl ester (L-NAME) or N omega-nitro-L-arginine. Decreases after doses of 1 and 10 mg/kg L-NAME averaged 23 +/- 3.8% and 34 +/- 7.2% at a heart rate of 90 bpm in open-chest animals. Similar reductions occurred after the administration of L-NAME and N omega-nitro-L-arginine in chronically instrumented animals and were unaffected by beta-adrenergic blockade. Intracoronary infusion of L-NAME in chronically instrumented animals reduced both myocardial O2 consumption and regional segment shortening, even at a dose that did not increase systemic arterial pressure. CONCLUSIONS: The blockade of NO synthesis reduces myocardial O2 consumption in vivo. The decrease in O2 consumption is accompanied by a decrease in segment shortening. It involves a direct myocardial action of NO, is unaffected by beta-blockade, and is consistent with in vitro studies indicating that low levels of NO augment contractile performance by inhibition of a cGMP-dependent phosphodiesterase.


Asunto(s)
Inhibidores Enzimáticos/farmacología , Corazón/efectos de los fármacos , Hemodinámica/efectos de los fármacos , Miocardio/metabolismo , NG-Nitroarginina Metil Éster/farmacología , Óxido Nítrico Sintasa/antagonistas & inhibidores , Nitroarginina/farmacología , Consumo de Oxígeno/efectos de los fármacos , Animales , Presión Sanguínea/efectos de los fármacos , Dióxido de Carbono/sangre , Circulación Coronaria/efectos de los fármacos , Perros , Corazón/fisiología , Frecuencia Cardíaca/efectos de los fármacos , Contracción Miocárdica/efectos de los fármacos , Óxido Nítrico/fisiología , Oxígeno/sangre , Función Ventricular Izquierda/efectos de los fármacos
4.
ASAIO J ; 42(6): 951-6, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-8959268

RESUMEN

Aortic helical flow may play an important role in plaque deposition, dissection formation, and organ perfusion. The authors have previously demonstrated, using in vitro flow models and transesophageal echocardiography, that helical flow begins in the mammalian aortic arch and continues into the descending thoracic aorta. The purpose of this study was to confirm thoracic aortic helical flow and document its extent into the abdominal aorta using direct measurements. Twelve mongrel dogs underwent surgery with exposure of the abdominal aorta up to the diaphragm. Six of the 12 underwent further thoracotomy with thoracic aorta exposure. Color Doppler ultrasound images were obtained using a 5 megaHz esophageal transducer, hand held, directly applied, and visually aligned for transverse aortic imaging. Helical flow was considered present with the appearance of red/blue hemicircles during a systolic wave when the aorta was imaged transversely. All six dogs that had thoracotomy showed clockwise thoracic aortic helical flow (along the direction of blood flow) at the retro left ventricular region. In all dogs, clockwise helical flow was demonstrated to and immediately beyond the renal arteries. In 11 of 12 dogs, clockwise helical flow was demonstrated 7 cm below the renal arteries. The study confirms the presence of helical flow in the thoracic aorta and documents its extent into the abdominal aorta below the level of the renal arteries. The teleologic flow pattern of mammals may extend to other classes of vertebrates and must be accounted for in studies of endothelial shear and flow separation. In addition, tangential velocities imparted by helical flow may affect organ perfusion.


Asunto(s)
Aorta Abdominal/fisiología , Aorta Torácica/fisiología , Flujo Sanguíneo Regional/fisiología , Animales , Aorta Abdominal/diagnóstico por imagen , Aorta Torácica/diagnóstico por imagen , Perros , Arteria Renal/fisiología , Ultrasonografía Doppler en Color
5.
Cathet Cardiovasc Diagn ; 32(1): 62-9, 1994 May.
Artículo en Inglés | MEDLINE | ID: mdl-8039223

RESUMEN

The objective of this research was to determine if the ultrasound emissions of the Doppler catheter can be used to locate its position in 3 dimensions by conventional echocardiography. A Doppler catheter has previously been shown to permit nonfluoroscopic retrograde catheterization of the aortic root and left ventricular chamber by using velocity waveform polarity for directional guidance. A significant difficulty in providing ultrasound catheter guidance, however, has been the inability to recognize the Doppler catheter tip, because each point at which a flexible catheter crosses the image plane can be misinterpreted as the catheter tip. Initial in vitro water bath trials were performed using the Doppler catheter attached to a standard velocimeter. Using a 5 MHz imaging transducer and color Doppler methods, the presence or absence of a banded color pattern which could demarcate the Doppler catheter tip was recorded at various angles in and out of the scanning plane. Using Doppler retrograde guidance and transesophageal echocardiography, color Doppler banded patterns, which could identify the Doppler catheter tip, were investigated in the dog aorta. In order to understand the physical mechanisms involved, a series of water bath trials were then conducted using the Doppler catheter attached to a velocimeter which was synchronized to the echo machine. Initial nonsynchronized water bath trials revealed distinct banded color patterns demarcating the Doppler catheter tip when it pointed in any direction within the beam width, except for a 40 degrees blind cone directly away from the imaging transducer.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Cateterismo Cardíaco , Aumento de la Imagen , Ultrasonografía Intervencional/métodos , Animales , Perros , Ecocardiografía Doppler
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA