Radiat Prot Dosimetry ; 180(1-4): 391-394, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-29688547

RESUMEN

The Neutron Standards Laboratory of CIEMAT has conducted the characterization of the independent spent fuel storage installation at the Trillo Nuclear Power Plant. At this facility, the spent fuel assemblies are stored in ENSA-DPT type dual purpose casks. Neutron characterization was performed by dosimetry measurements with a neutron survey meter (LB6411) inside the facility, around an individual cask and between stored casks, and outside the facility. Spectra measurements were also performed with a Bonner sphere system in order to determine the integral quantities and validate the use of the neutron monitor at the different positions. Inside the facility, measured neutron spectra and neutron ambient dose equivalent rate are consistent with the casks spatial distribution and neutron emission rates, and measurements with both instruments are consistent with each other. Outside the facility, measured neutron ambient dose equivalent rates are well below the 0.5 µSv/h limit established by the nuclear regulatory authority.


Asunto(s)
Neutrones , Plantas de Energía Nuclear , Monitoreo de Radiación/métodos , Protección Radiológica/instrumentación , Residuos Radiactivos/análisis , Simulación por Computador , Diseño de Equipo , Humanos , Método de Montecarlo , Dosis de Radiación , Protección Radiológica/métodos