RESUMEN
This work reports a new sensitive strategy for the determination of tau protein, a hallmark of Alzheimer's disease (AD), involving a sandwich immunoassay and amperometric detection at disposable screen-printed carbon electrodes (SPCEs) modified with a gold nanoparticles-poly(amidoamine) (PAMAM) dendrimer nanocomposite (3D-Au-PAMAM) covalently immobilized onto electrografted p-aminobenzoic acid (p-ABA). The capture antibody (CAb) was immobilized by crosslinking with glutaraldehyde (GA) on the amino groups of the 3D-Au-PAMAM-p-ABA-SPCE, where tau protein was sandwiched with a secondary antibody labeled with horseradish peroxidase (HRP-DAb). Amperometry at -200 mV (vs the Ag pseudo-reference electrode) upon the addition of hydroquinone (HQ) as electron transfer mediator and H2O2 as the enzyme substrate was used to detect the immunocomplex formation. The great analytical performance of the immunosensor in terms of selectivity and low limit of detection (LOD) (1.7 pg mL-1) allowed the direct determination of the target protein in raw plasma samples and in brain tissue extracts from healthy individuals and post mortem diagnosed AD patients, using a simple and fast protocol.
Asunto(s)
Enfermedad de Alzheimer , Técnicas Biosensibles , Nanopartículas del Metal , Enfermedad de Alzheimer/diagnóstico , Encéfalo , Carbono , Técnicas Electroquímicas , Electrodos , Oro , Humanos , Peróxido de Hidrógeno , Inmunoensayo , Límite de Detección , Proteínas tauRESUMEN
This work describes the preparation of an electrochemical immunosensor for ethinylestradiol (EE2) based on grafting of diazonium salt of 4-aminobenzoic acid onto a glassy carbon electrode modified with silver nanoparticles/SiO2/graphene oxide hybrid followed by covalent binding of anti-ethinylestradiol (anti-EE2) to activated carboxyl groups. A competitive immunoassay was developed for the determination of the hormone using peroxidase-labeled ethinylestradiol (HRP-EE2) and measurement of the amperometric response at -200mV in the presence of hydroquinone (HQ) as redox mediator. The calibration curve for EE2 exhibited a linear range between 0.1 and 50ng/mL (r(2)=0.996), with a detection limit of 65pg/mL. Interference studies with other hormones related with EE2 revealed the practical specificity of the developed method for the analyte. A good reproducibility, with RSD=4.5% (n=10) was also observed. The operating stability of a single bioelectrode modified with anti-EE2 was maintained at least for 15 days when it was stored at 4°C under humid conditions between measurements. The developed immunosensor was applied to the analysis of spiked urine with good results.