Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Micromachines (Basel) ; 15(8)2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39203631

RESUMEN

The clinical diagnosis of a malignant pleural effusion (MPE) is still based on the detection of tumor cells in the pleural effusion. The question of how to improve the efficiency and accuracy of detecting an MPE still remains. This study explores the use of microfluidic technology to concentrate cells in an MPE and achieved the detection of the cell marker TPN in the microarray capture area. TPN is a mitochondria-specific bio-probe that can identify tumor cells on the basis of differences in the mitochondrial potential. First, we designed a microfluidic chip to analyze its performance. The results show that when the total flow rate of the injected chip was 12 mL/h and the volume ratio of cell separation liquid to cell suspension was 1:1, the target cells (A549, MCF-7, and Hela) were enriched and the purity was improved to 98.7-99.3%. Finally, an MPE from cancer patients was used to detect the chip's ability to isolate and enrich tumor cells. Furthermore, the fluorescent identification of the TPN within the tumor cells was simultaneously achieved on the microfluidic chip. In conclusion, the potential to improve the efficiency of the clinical diagnosis of MPEs is provided by the chip structure and analysis conditions explored in this study.

2.
Micromachines (Basel) ; 14(4)2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-37421004

RESUMEN

Malignant pleural effusion is a common clinical problem, which often occurs in cases of malignant tumors, especially in lung cancer. In this paper, a pleural effusion detection system based on a microfluidic chip, combined with specific tumor biomarker, hexaminolevulinate (HAL), used to concentrate and identify tumor cells in pleural effusion was reported. The lung adenocarcinoma cell line A549 and mesothelial cell line Met-5A were cultured as the tumor cells and non-tumor cells, respectively. The optimum enrichment effect was achieved in the microfluidic chip when the flow rates of cell suspension and phosphate-buffered saline achieved 2 mL/h and 4 mL/h, respectively. At the optimal flow rate, the proportion of A549 increased from 28.04% to 70.01% due to the concentration effect of the chip, indicating that tumor cells could be enriched by a factor of 2.5 times. In addition, HAL staining results revealed that HAL can be used to identify tumor cells and non-tumor cells in chip and clinical samples. Additionally, the tumor cells obtained from the patients diagnosed with lung cancer were confirmed to be captured in the microfluidic chip, proving the validity of the microfluidic detection system. This study preliminarily demonstrates the microfluidic system is a promising method with which to assist clinical detection in pleural effusion.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA