Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Inorg Chem ; 63(11): 4807-4812, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38446174

RESUMEN

Two new congruently melting Pb-containing halogen silicates, Pb3[O10Pb20](SiO4)4X10 (X = Cl, Br), have been synthesized using a high-temperature solution method. Their crystal structures were determined by single-crystal X-ray diffraction, and both compounds crystallize in the orthorhombic space group Cmca. In both structures, the mirror-symmetric bilayer composed of Pb-O polyhedra is observed for the first time in Pb-containing silicates and belongs to α-PbO derivatives and is related to the Aurivillius phase. Thermal behavior analysis, UV-vis diffuse-reflectance spectroscopy, and IR spectroscopy were also performed. The Pb3[O10Pb20](SiO4)4Cl10 matrix was doped with Eu3+ ions as a dopant, and its potential application in fluorescence was confirmed from the resulting orange-red emission.

2.
Materials (Basel) ; 16(12)2023 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-37374440

RESUMEN

Optical coherence tomography is a new promising chromatographic imaging technique with the advantages of noncontact and high resolution without damage, which is widely used in the field of biological tissue detection and imaging. As an important optical element in the system, the wide-angle depolarizing reflector plays a key role in the accurate acquisition of optical signals. Ta2O5 and SiO2 are selected as the coating materials for the technical parameter requirements of the reflector in the system. Based on the basic theory of optical thin film and combined with MATLAB and OptiLayer software, the design of 0~60° incident 1064 ± 40 nm depolarizing reflective film is realized by establishing the evaluation function of the film system. To optimize the oxygen-charging distribution scheme during film deposition, the weak absorption properties of the film materials are characterized by optical thermal co-circuit interferometry. According to the sensitivity distribution of the film layer, the optical control monitoring scheme with a thickness error of less than 1% is designed rationally. "Crystal control + optical control" is used to precisely control the thickness of each film layer and complete the preparation of resonant cavity film. The measurement results show that the average reflectance is more than 99.5%, and the deviation of P-light and S-light is less than 1% in the 1064 ± 40 nm wavelength band range from 0° to 60°, which meets the requirements of optical coherence tomography system.

3.
Materials (Basel) ; 16(4)2023 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-36837127

RESUMEN

Crystal coating is an important process in laser crystal applications. According to the crystal characteristics of neodymium-doped yttrium vanadate (Nd:YVO4), its intrinsic parameters, and optical film design theory, Ta2O5 and SiO2 were selected separately as high and low refractive index materials. The optical properties and surface roughness of the films were characterized by OptiLayer and Zygo interferometers, and the effects of ion source bias on refractive index and surface roughness were investigated so that the optimal ion source parameters were determined. Optical monitoring and quartz crystal control were combined to accurately control the thickness of each film layer and to reduce the monitoring error of film thickness. The prepared crystal device was successfully applied to the 1176 nm laser output system.

4.
Materials (Basel) ; 15(13)2022 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-35806830

RESUMEN

With the rapid development of laser medicine, there are higher requirements placed on the performance of optical components in various medical systems. This paper is aimed at exploring the critical optical devices of medical equipment for treating periodontitis and gingivitis. The cathode sputtering method was used to produce the wide-angle short-wave pass filter, and a hundreds grid fastness test was conducted to detect the occurrence of film peeling. Considering the results of SEM, transmission spectrum, and stress test of the sample, an analysis was conducted as to the cause of poor bonding force for the film. By increasing the amount of argon gas and adjusting the baking temperature, the problem of film peeling was resolved. Besides, a short-wave pass filter film with good bonding and low roughness was obtained to meet the requirements of laser medical equipment.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA