Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Angew Chem Int Ed Engl ; 63(30): e202404401, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-38729917

RESUMEN

It is a crucial role for enhancing the power conversion efficiency (PCE) of perovskite solar cells (PSCs) to prepare high-quality perovskite films, which can be achieved by delaying the crystallization of perovskite film. Hence, we designed difluoroacetic anhydride (DFA) as an additive to regulating crystallization process thus reducing defect formation during perovskite film formation. It was found DFA reacts with DMSO by forming two molecules, difluoroacetate thioether ester (DTE) and difluoroacetic acid (DA). The strong bonding DTE⋅PbI2 and DA⋅PbI2 retard perovskite crystallization process for high-quality film formation, which was monitored through in situ UV/Vis and PL tests. By using DFA additives, we prepared perovskite films with high-quality and low defects. Finally, a champion PCE of 25.28 % was achieved with excellent environmental stability, which retained 95.75 % of the initial PCE after 1152 h at 25 °C under 25 % RH.

2.
Adv Mater ; 33(8): e2006010, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33475209

RESUMEN

Low ionic migration is required for a semiconductor material to realize stable high-performance X-ray detection. In this work, successful controlled incorporation of not only methylammonium (MA+ ) and cesium (Cs+ ) cations, but also bromine (Br- ) anions into the FAPbI3 lattice to grow inch-sized stable perovskite single crystal (FAMACs SC) is reported. The smaller cations and anions, comparing to the original FA+ and I- help release lattice stress so that the FAMACs SC shows lower ion migration, enhanced hardness, lower trap density, longer carrier lifetime and diffusion length, higher charge mobility and thermal stability, and better uniformity. Therefore, X-ray detectors made of the superior FAMACs SCs show the highest sensitivity of (3.5 ± 0.2) × 106 µC Gyair -1 cm-2 , about 29 times higher than the latest record of 1.22 × 105 µC Gyair -1 cm-2 for polycrystalline MAPbI3 wafer under the same 40 keV X-ray radiation. Furthermore, the FAMACs SC X-ray detector shows a low detection limit of 42 nGy s-1 , stable dark current, and photocurrent response. Finally, it is demonstrated that high contrast X-ray imaging is realized using the FAMACs SC detector. The effective triple-cation mixed halide strategy and the high crystalline quality make the present FAMACs SCs promising for next-generation X-ray imaging systems.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA