Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ann Thorac Surg ; 81(2): 591-8; discussion 598, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16427858

RESUMEN

BACKGROUND: Cardiovascular disease remains the most frequent cause of death for patients with end-stage renal disease. To determine the long-term benefit of surgical revascularization in this high-risk population, we studied our patients with ESRD having coronary artery bypass graft surgery (CABG), comparing the results of off-pump to on-pump revascularization. As a baseline reference group, we used dialysis patients with a diagnosis of coronary artery disease who did not have surgical revascularization or percutaneous coronary interventions. The control group data set was obtained from the United States Renal Data System. METHODS: From January 1995 through July 2003, 158 patients with end-stage renal disease who were on hemodialysis (excluding those in cardiogenic shock, needing resuscitation, and with emergent or salvage status) underwent CABG. Fifty-nine patients (37.3%) had off-pump revascularization, and 99 patients (62.7%) had bypass grafting utilizing extracorporeal circulation. Preoperative risk factors and operative results were analyzed, and longitudinal survival data obtained. RESULTS: The mean follow-up time was 39.1 months (median, 33.1) for the on-pump patients and 18.3 months (median, 14.7) for off-pump. The total number of anastomoses per off-pump patient was 2.4 +/- 1.0, and with cardiopulmonary bypass (CPB), it was 3.3 +/- 0.9 (p < 0.001). Patients revascularized off-pump had an operative mortality rate of 1.7%, whereas patients grafted using CPB had an operative mortality of 17.2% (p = 0.003). The predicted risk of mortality for the off-pump group (9.3% +/- 7.4%) was not statistically different from the on-pump cohort (9.1% +/- 7.7%, p = not significant). Logistic regression analysis indicates that CPB use was an independent risk factor for early death (p = 0.01, odds ratio = 13.6, 95% confidence interval: 1.7 to 110). Long-term follow-up demonstrated that the patients revascularized using CPB had improved survival compared with the off-pump patients and the control population. CONCLUSIONS: Off-pump CABG improves early mortality rate when compared with conventional revascularization. Despite a greater operative mortality, however, long-term survival is improved in the patients revascularized with CPB as compared with the off-pump cohort, suggesting possible advantages from a more complete revascularization in this population.


Asunto(s)
Puente de Arteria Coronaria Off-Pump , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/cirugía , Fallo Renal Crónico/complicaciones , Fallo Renal Crónico/mortalidad , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Análisis de Supervivencia
2.
Heart Surg Forum ; 7(4): E333-6; discussion E336, 2004 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-15454388

RESUMEN

BACKGROUND: New alternatives exist using various energy sources and lesion lines for the surgical treatment of atrial fibrillation (AF). The efficacy of these options compared to the cut-and-sew maze III procedure is unknown. METHODS: From August 1996 to August 2003, 79 patients have undergone a procedure for AF, with 70 patients currently more than 3 months postsurgery. The patients (58 continuous, 12 paroxysmal) underwent a surgical procedure for AF, lone AF (12) and with concomitant procedures (58). Techniques included cut and sew (23), bipolar radiofrequency (RF) (28) and unipolar-RF (10), and cryothermy (9). Lesions included maze III (46), pulmonary vein isolation (16), and pulmonary vein isolation plus mitral annular connecting line only (8). RESULTS: Follow-up was complete in 58 (83%) of 70 patients at a mean time of 595 +/- 750 days (range, 24-2530 days). The operative mortality was 0% in lone AF patients and 7.1% (5/70) in patients undergoing concomitant procedures. Need for perioperative pacemaker was 22.9%. Overall, normal sinus rhythm (NSR) was restored in 82.7% of patients, with success in 83.3% (10/12) lone procedures and 82.6% (38/46) concomitant procedures ( P = NS); the rate of continuous AF was 85.1% (40/47) and SR with paroxysmal fibrillation was 72.7% (8/11) ( P = NS). Traditional maze was successful in 80.6% (29/36) patients, pulmonary vein isolation was successful 93.3% (14/15), and left-sided maze in 71.4% (5/7) ( P = NS). Cut and sew procedures were successful in 88.2% (15/17), RF-bipolar in 84.0% (21/25), RFunipolar in 77.8% (7/9), and cryothermy in 71.4% (5/7) ( P = NS). Energy source, lesion set, AF duration, and lone/concomitant procedure were the factors subjected to logistic regression analysis. No factors were predictive of achieving postoperative NSR. CONCLUSIONS: Our early experience with newer surgical techniques employing different energy sources and fewer incision lines suggests that the success rate may approach the results obtained with traditional cut-and-sew Cox-maze III procedures.


Asunto(s)
Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardiovasculares/métodos , Femenino , Humanos , Masculino , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA