Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Org Chem ; 81(3): 1295-9, 2016 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-26741793

RESUMEN

A mild, operationally simple, and single-step transition-metal-free protocol for the synthesis of enantiomerically pure (R)-(+)-2'-amino-1,1'-binaphthalen-2-ol (R-NOBIN) from (R)-(+)-1,1'-binaphthyl-2,2'-diamine (R-BINAM) is reported. The one-pot conversion proceeds with good yield and shows no racemization. The hydroxyl on the R-NOBIN product was shown to have come from water in the reaction medium via an H2(18)O study. The correct value of the specific rotation of R-NOBIN was reported.

2.
Artículo en Inglés | MEDLINE | ID: mdl-24910297

RESUMEN

The enantiomeric separation of a series of racemic functionalized ethano-bridged Tröger base compounds was examined by high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). Using HPLC and CE the entire set of 14 derivatives was separated by chiral stationary phases (CSPs) and chiral additives composed of cyclodextrin (native and derivatized) and cyclofructan (derivatized). Baseline separations (Rs ≥ 1.5) in HPLC were achieved for 13 of the 14 compounds with resolution values as high as 5.0. CE produced 2 baseline separations. The separations on the cyclodextrin CSPs showed optimum results in the reversed phase mode, and the LARIHC cyclofructan CSPs separations showed optimum results in the normal phase mode. HPLC separation data of the compounds was analyzed using principal component analysis (PCA). The PCA biplot analysis showed that retention is governed by the size of the R1 substituent in the case of derivatized cyclofructan and cyclodextrin CSPs, and enantiomeric resolution closely correlated with the size of the R2 group in the case of non-derivatized γ-cyclodextrin CSP. It is clearly shown that chromatographic retention is necessary but not sufficient for the enantiomeric separations of these compounds.

3.
J Chromatogr A ; 1357: 172-81, 2014 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-24835594

RESUMEN

Normal phase chiral HPLC methods are presented for the enantiomeric separation of 30 biaryl atropisomers including 18 new compounds recently produced via a novel synthetic approach. Three new cyclofructan based chiral stationary phases were evaluated. Separations were achieved for all but six analytes and the LARIHC™ CF6-P alone provided 15 baseline separations. Effects of polar modifiers and temperature effects also were studied. Apparent thermodynamic parameters were determined by van't Hoff plots. Preparative scale methods were developed and employed resulting in the first ever isolation of these novel atropisomers in their pure enantiomeric form. Insights into the mechanism of retention and chiral discrimination are presented.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Fructanos/química , Compuestos Orgánicos/aislamiento & purificación , Cromatografía Líquida de Alta Presión/instrumentación , Compuestos Orgánicos/química , Estereoisomerismo , Termodinámica
4.
Artículo en Inglés | MEDLINE | ID: mdl-24631813

RESUMEN

The enantiomeric separation of a series of racemic functionalized ethano-bridged Tröger base compounds was examined by high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). Using HPLC and CE the entire set of 14 derivatives was separated by chiral stationary phases (CSPs) and chiral additives composed of cyclodextrin (native and derivatized) and cyclofructan (derivatized). Baseline separations (Rs≥1.5) in HPLC were achieved for 13 of the 14 compounds with resolution values as high as 5.0. CE produced 2 baseline separations. The separations on the cyclodextrin CSPs showed optimum results in the reversed phase mode, and the LARIHC™ cyclofructan CSPs separations showed optimum results in the normal phase mode. HPLC separation data of the compounds was analyzed using principal component analysis (PCA). The PCA biplot analysis showed that retention is governed by the size of the R1 substituent in the case of derivatized cyclofructan and cyclodextrin CSPs, and enantiomeric resolution closely correlated with the size of the R2 group in the case of non-derivatized γ-cyclodextrin CSP. It is clearly shown that chromatographic retention is necessary but not sufficient for the enantiomeric separations of these compounds.


Asunto(s)
Azocinas/química , Azocinas/aislamiento & purificación , Cromatografía Líquida de Alta Presión/métodos , Ciclodextrinas/química , Electroforesis Capilar/métodos , Fructanos/química , Azocinas/análisis , Análisis de Componente Principal , Estereoisomerismo
5.
J Agric Food Chem ; 62(8): 1832-8, 2014 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-24527961

RESUMEN

Analysis of ethanol and water in consumer products is important in a variety of processes and often is mandated by regulating agencies. A method for the simultaneous quantitation of ethanol and water that is simple, accurate, precise, rapid, and cost-effective is demonstrated. This approach requires no internal standard for the quantitation of both ethanol and water at any/all levels in commercial products. Ionic liquid based gas chromatography (GC) capillary columns are used to obtain a fast analysis with high selectivity and resolution of water and ethanol. Typical run times are just over 3 min. Examination of the response range of water and ethanol with GC, thermal conductivity detection (TCD), and barrier ionization detection (BID) is performed. Quantitation of both ethanol and water in consumer products is accomplished with both TCD and BID GC detectors using a nonlinear calibration. Validation of method accuracy is accomplished by using standard reference materials.


Asunto(s)
Cromatografía de Gases/métodos , Etanol/análisis , Análisis de los Alimentos/métodos , Agua/análisis , Cromatografía de Gases/instrumentación , Análisis de los Alimentos/instrumentación , Líquidos Iónicos/química , Conductividad Térmica
6.
J Sep Sci ; 37(5): 558-65, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24415651

RESUMEN

In contrast to the plethora of publications on the separation of fatty acids, analogous studies involving fatty amines are scarce. A recently introduced ionic-liquid-based capillary column for GC was used to separate trifluoroacetylated fatty amines focusing on the analysis of a commercial sample. Using the ionic liquid column (isothermal mode at 200 °C) it was possible to separate linear primary fatty amines from C12 to C22 chain length in less 25 min with MS identification. The log of the amine retention factors are linearly related to the alkyl chain length with a methylene selectivity of 0.117 kcal/mol for the saturated amines and 0.128 kcal/mol for the mono-unsaturated amines. The sp2 selectivity for unsaturated fatty amines also could be calculated as 0.107 kcal/mol for the ionic liquid column. The commercial sample was quantified by GC with flame ionization detection (FID). An LC method also was developed with a reversed phase gradient separation using acetonitrile/formate buffer mobile phases and ESI-MS detection. Native amines could be detected and identified by their single ion monitoring chromatograms even when partial coelution was observed. The analysis of the commercial sample returned results coherent with those obtained by GC-FID and with the manufacturer's data.


Asunto(s)
Aminas/química , Cromatografía de Gases/métodos , Cromatografía Liquida/métodos , Ácidos Grasos/química , Estructura Molecular , Espectrometría de Masa por Ionización de Electrospray
7.
J Chromatogr A ; 1305: 94-101, 2013 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-23906806

RESUMEN

Isochromene derivatives are very important precursors in the natural products industry. Hence the enantiomeric separations of chiral isochromenes are important in the pharmaceutical industry and for organic asymmetric synthesis. Here we report enantiomeric separations of 21 different chiral isochromene derivatives, which were synthesized using alkynylbenzaldehyde cyclization catalyzed by chiral gold(I) acyclic diaminocarbene complexes. All separations were achieved by high-performance liquid chromatography with cyclodextrin based (Cyclobond) chiral stationary phases. Retention data of 21 chiral compounds and 14 other previously separated isochromene derivatives were analyzed using principal component analysis. The effect of the structure of the substituents on the isochromene ring on enantiomeric resolution as well as the other separation properties was analyzed in detail. Using principal component analysis it can be shown that the structural features that contribute to increased retention are different from those that enhance enantiomeric resolution. In addition, principal component analysis is useful for eliminating redundant factors from consideration when analyzing the effect of various chromatographic parameters. It was found that the chiral recognition mechanism is different for the larger γ-cyclodextrin as compared to the smaller ß-cyclodextrin derivatives. Finally this specific system of chiral analytes and cyclodextrin based chiral selectors provides an effective format to examine the application of principal component analysis to enantiomeric separations using basic retention data and structural features.


Asunto(s)
Benzopiranos/aislamiento & purificación , Cromatografía Líquida de Alta Presión/métodos , Ciclodextrinas/química , Análisis de Componente Principal , Estereoisomerismo
8.
Drug Test Anal ; 4(12): 986-90, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22786761

RESUMEN

1,3-Dimethylamylamine (DMAA) is a stimulant existing in various pre-workout supplements and often labelled as part of geranium plants. The safety and origin of DMAA in these supplements is the subject of intense debate. In this study, the enantiomeric and diastereomeric ratios of two different known synthetic DMAA compounds, as well as the total concentrations of DMAA and its stereoisomeric ratios in 13 different supplements, were determined by gas chromatography. The stereoisomeric ratios of DMAA in the synthetic standards and in all the commercial supplements were indistinguishable. Eight different commercial geranium extracts of different geographical origins (China and the Middle East) were examined for the presence of DMAA by high performance liquid chromatography coupled with mass spectrometry (HPLC-MS). No DMAA was detected in any of the eight geranium products with a limit of detection of 10 parts per billion (w/w).


Asunto(s)
Aminas/análisis , Suplementos Dietéticos/análisis , Geranium/química , Sustancias para Mejorar el Rendimiento/análisis , Preparaciones de Plantas/química , Cromatografía de Gases/normas , Cromatografía Líquida de Alta Presión/normas , Límite de Detección , Espectrometría de Masas/normas , Aceites de Plantas/química , Estándares de Referencia , Estereoisomerismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA