1.
Gastrointest Endosc ; 72(3): 593-9, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20646698

RESUMEN

BACKGROUND: Performing endoscopic submucosal dissection (ESD) by using standard endoscopy platforms is technically challenging because of the equipment's lack of dexterity. OBJECTIVE: To explore the feasibility of using the Master and Slave Transluminal Endoscopic Robot (MASTER), a novel robotics-enhanced endosurgical system, to perform ESD. DESIGN: ESD was performed on simulated gastric lesions in 5 Erlangen porcine stomach models (ex vivo) and 5 live pigs (in vivo). Performance of ESD by using the MASTER was compared with that using the insulation-tipped (IT) diathermic knife. SETTING: SMART Laboratory, Advance Surgical Training Centre, National University Hospital, Singapore. SUBJECTS: Five Erlangen porcine stomach models and 5 pigs, 5 to 7 months old, each weighing about 35 kg. INTERVENTIONS: ESD. MAIN OUTCOME MEASUREMENTS: Lesion resection time, grasper and hook efficacy grade, completeness of resection, and presence of procedure-related perforation. RESULTS: In the Erlangen stomach models, 15 simulated lesions from the cardia, antrum, and body were removed en bloc (mean dimension, 37.4 x 26.5 mm) by electrocautery excision using the MASTER. The mean ESD time was 23.9 minutes (range 7-48 minutes). There was no difference in the dissection times of lesions at different locations (P = .449). In the live pigs, the MASTER took a mean of 16.2 minutes (range 3-29 minutes) to complete the ESD of 5 gastric lesions, whereas the IT diathermic knife took 18.6 minutes (range 9-34 minutes). There was no significant difference in the times taken (P = .708). All lesions were excised en bloc; the mean dimensions of lesions resected by the MASTER and the IT diathermic knife were 37.2 x 30.1 mm and 32.78 x 25.6 mm, respectively. The MASTER exhibited good grasping and cutting efficiency throughout. Surgical maneuvers were achieved with ease and precision. There was no incidence of excessive bleeding or stomach wall perforation. LIMITATIONS: Exploratory study with limited sample size. CONCLUSIONS: Performing ESD by using the MASTER is feasible.


Asunto(s)
Disección/instrumentación , Mucosa Gástrica/cirugía , Gastroscopios , Robótica/instrumentación , Neoplasias Gástricas/cirugía , Cirugía Asistida por Computador/instrumentación , Animales , Modelos Animales de Enfermedad , Electrocoagulación/instrumentación , Diseño de Equipo , Estudios de Factibilidad , Mucosa Gástrica/patología , Neoplasias Gástricas/patología , Instrumentos Quirúrgicos , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA