Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 312
Filtrar
2.
Heart Rhythm ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38936446

RESUMEN

BACKGROUND: Heart rate score (HRSc), the percentage of atrial depolarizations in the largest paced and sensed 10-beats/min histogram bin recorded in cardiac devices, is associated with several adverse outcomes, but it remains uncertain whether HRSc independently predicts atrial high-rate episodes (AHREs) in patients with sinus node dysfunction (SND) undergoing pacemaker (PM) implantation. OBJECTIVE: This study aimed to determine whether initial HRSc after PM implantation predicts new-onset AHREs in patients with SND. METHODS: Patients had Boston Scientific PMs implanted for SND from 2012 to 2021 at Cleveland Clinic, University of Occupational and Environmental Health, Japan, Kyushu Rosai Hospital, and JCHO Kyushu Hospital. Patients were excluded if they had atrial fibrillation before PM implantation or AHREs within 3 months after implantation. Subsequent AHREs after implantation were evaluated and correlated with HRSc. RESULTS: During 48.9 (interquartile range, 25.7-50.4) months, 130 consecutive PM patients (76 ± 10 years; 40% male) had a median initial HRSc of 74% (57%-86%). AHREs defined by >1%, >6 h/d burden, and atrial tachycardia response events >24 hours developed in 27 of 130 (21%), 15 of 130 (12%), and 9 of 130 (7%), respectively. For each definition, patients with HRSc ≥80% had higher occurrence of AHREs than those with HRSc <80% (both P = .008, log-rank test). After adjustment for age, race, comorbidities, left ventricular ejection fraction, left atrial diameter, and cumulative percentage of right atrial and right ventricular pacing, initial HRSc ≥80% (hazard ratio, 3.33; 95% CI, 1.35-8.18; P = .009) and male sex (hazard ratio, 2.59; 95% CI, 1.06-6.33; P = .04) independently predicted AHREs. CONCLUSION: HRSc ≥80% is associated with new-onset, device-determined AHREs for patients undergoing PM implantation for SND. HRSc may have prognostic and therapeutic implications.

3.
Heart Rhythm ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38936445

RESUMEN

BACKGROUND: Traditional post-approval study (PAS) designs have been accepted by regulatory authorities to fulfill postmarketing requirements for cardiac leads, but they have several limitations. OBJECTIVE: We conducted a proof-of-concept study of alternative methods that use real-world data (RWD) to evaluate lead safety in large populations of patients. METHODS: Abbott patient device databases were linked with Medicare Fee-For-Service (FFS) claims to identify lead complications in patients implanted with Abbott Optisure lead. A 1:1 comparison between the PAS method and RWD method of detecting mechanical lead-related complication events was conducted in 444 PAS participants who were enrolled in Medicare FFS. Agreement between methods was evaluated by McNemar test and Cohen κ. Survival free from complications at 3 years was compared between the PAS and RWD cohorts with an equivalence acceptance criterion of ±2.5%. RESULTS: There were 1171 PAS patients and 5804 Medicare FFS patients who received an Optisure lead between August 27, 2014, and June 14, 2016. Patients were observed through December 31, 2018. Complete agreement was found between PAS-reported and claims-detected complications (McNemar P value = 1; Cohen κ = 1). Survival free from complications at 3 years by the RWD method was 98.4% (95% confidence limit, 98.0%-98.7%), which was within the acceptable range of the PAS 98.4% (95% confidence limit, 97.6%-99.0%). CONCLUSION: These results show a close agreement between RWD-detected and PAS-reported lead complication rates, which highlights the potential benefits of RWD-based methods to enhance the generation of clinical evidence for lead safety.

4.
J Cardiovasc Electrophysiol ; 35(7): 1382-1392, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38725252

RESUMEN

INTRODUCTION: Reports of comparison with procedural outcomes for implantable cardioverter defibrillator (ICD) and pacemaker (PM) transvenous lead extraction (TLE) are old and limited. We sought to compare the safety, efficacy, and procedural properties of ICD and PM TLE and assess the impact of lead age. METHODS: The study cohort included all consecutive patients with ICD and PM TLE in the Cleveland Clinic Prospective TLE Registry between 2013 and 2022. Extraction success, complications, and failure employed the definitions described in the HRS 2017 TLE guidelines. RESULTS: A total of 885 ICD leads, a median implant duration of 8 (5-11) years in 810 patients, and 1352 PM leads of 7 (3-13) years in 807 patients were included. Procedural success rates in ICD patients were superior to those of PM in >20 years leads but similar in ≤20 years leads. In the PM group, the complete success rate of TLE decreased significantly according to the increase of lead age, but not in the ICD group. ICD TLE required more extraction tools compared with PM TLE but cases with older leads required non-laser sheath extraction tools in both groups. The most common injury site in major complication cases differed between ICD and PM TLE, although major complication rates showed no difference in both groups (2.7% vs. 1.6%, p = .12). CONCLUSION: The procedural success rate by TLE is greater for ICD patients than PM patients with leads >20 years old but requires more extraction tools. Common vascular complication sites and the impact of lead age on procedural outcomes and required tools differed between ICD and PM TLE.


Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos , Marcapaso Artificial , Sistema de Registros , Humanos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Remoción de Dispositivos/efectos adversos , Resultado del Tratamiento , Factores de Tiempo , Factores de Riesgo , Ohio , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Hospitales de Alto Volumen , Anciano de 80 o más Años , Medición de Riesgo
5.
JACC Clin Electrophysiol ; 10(5): 916-926, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38520434

RESUMEN

BACKGROUND: Past clinical trials have shown the benefit of implantable cardioverter-defibrillators (ICDs) for reducing sudden cardiac death in at-risk patients. However, heart failure management and ICD technology have changed since these trials were first published. An updated assessment of ICD mortality benefit is needed. OBJECTIVES: The purpose of this study was to compare mortality rates between patients with a primary prevention (PP) indication for an ICD who did or did not receive an ICD using a contemporary, real-world data set. METHODS: Data was obtained from a large electronic health record data set covering patients in the United States from 2012 through 2020 who had a PP indication for an ICD and survived at least 1-year postindication. RESULTS: A total of 25,296 patients were identified as having a PP indication for ICD implantation, of which 2,118 (8.4%) were treated with an ICD within a year. Treated patients were younger than nontreated patients (age 63.4 years vs 66.1 years) with a smaller proportion of women (25.0% vs 36.7%). After 4-to-1 propensity matching, treated patients had similar clinical characteristics to nontreated patients. A Cox proportional hazard model estimated a 24.3% lower risk of all-cause mortality in patients when treated vs not treated with an ICD (HR: 0.757; 95% CI: 0.678-0.835; P <0.001). There was no detectable difference in ICD benefit between patients with ischemic and nonischemic heart disease (P = 0.50). CONCLUSIONS: ICD treatment of patients with a PP indication is associated with improved mortality even in the context of evolving adjunctive HF treatment, consistent with earlier landmark trials.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Prevención Primaria , Humanos , Desfibriladores Implantables/estadística & datos numéricos , Femenino , Masculino , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Persona de Mediana Edad , Anciano , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Estados Unidos/epidemiología , Estudios Retrospectivos
6.
JACC Cardiovasc Imaging ; 17(6): 669-701, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38466252

RESUMEN

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multisocietal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multifocal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Asunto(s)
Consenso , Técnica Delphi , Fluorodesoxiglucosa F18 , Leucocitos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Valor Predictivo de las Pruebas , Radiofármacos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Humanos , Fluorodesoxiglucosa F18/administración & dosificación , Radiofármacos/administración & dosificación , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/normas , Pronóstico , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Reproducibilidad de los Resultados , Endocarditis/diagnóstico por imagen , Infecciones Cardiovasculares/diagnóstico por imagen , Algoritmos
7.
Heart Rhythm ; 21(5): e1-e29, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38466251

RESUMEN

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Asunto(s)
Consenso , Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos , Humanos , Infecciones Cardiovasculares/diagnóstico , Endocarditis/diagnóstico , Endocarditis/diagnóstico por imagen , Fluorodesoxiglucosa F18/farmacología , Leucocitos , Imagen Multimodal/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos/farmacología , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Sociedades Médicas , Estados Unidos
8.
J Nucl Cardiol ; 34: 101786, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38472038

RESUMEN

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Asunto(s)
Infecciones Cardiovasculares , Endocarditis , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18 , Consenso , Tomografía Computarizada por Rayos X , Imagen Multimodal , Endocarditis/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único
9.
Clin Infect Dis ; 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38466039

RESUMEN

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

10.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38000893

RESUMEN

AIMS: Transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads is considered challenging. The structure of each ICD leads is variable between manufacturer and model families. The net impact of lead family on the safety and effectiveness of TLE is poorly characterized. We assessed the safety and efficacy of ICD TLE and the impact of manufacturer ICD model family on the outcomes. METHODS AND RESULTS: The study cohort included all consecutive patients with ICD who underwent TLE between 2013 and 2022 and are enrolled in the Cleveland Clinic Prospective TLE Registry. A total of 885 ICD leads (median implant duration 8 years) in 810 patients were included. Complete ICD TLE success was achieved in 97.2% of the leads (n = 860) and in 98.0% of the patients (n = 794). Major complications occurred in 22 patients (2.7%). Complete procedural success rate varied by manufacturer and lead family; Medtronic 98.9%, Abbott 95.9%, Boston Scientific 95.0%, Biotronik 91.2%, P = 0.03, and Linox family leads had the lowest, 89.7% P = 0.02. Multivariable predictors of incomplete ICD lead removal included ICD lead age > 10 years and Linox family lead. Multivariable predictors of major complications included ICD lead age > 15 years and longer lead extraction time, and predictors of all-cause mortality within 30 days included lead extraction for infection, end-stage renal disease, and higher New York Heart Association functional class. CONCLUSION: Complete and safe ICD lead removal rate by TLE is extremely high but varied by manufacturer and lead family. Linox family lead and >10 years lead age were independent predictors of incomplete lead removal.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Niño , Adolescente , Desfibriladores Implantables/efectos adversos , Estudios Prospectivos , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/métodos , Estudios Retrospectivos , Resultado del Tratamiento
11.
JAMA Cardiol ; 8(12): 1165-1173, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37851461

RESUMEN

Importance: Complete hardware removal is a class I recommendation for cardiovascular implantable electronic device (CIED) infection, but practice patterns and outcomes remain unknown. Objective: To quantify the number of Medicare patients with CIED infections who underwent implantation from 2006 to 2019 and lead extraction from 2007 to 2019 to analyze the outcomes in these patients in a nationwide clinical practice cohort. Design, Setting, and Participants: This cohort study included fee-for-service Medicare Part D beneficiaries from January 1, 2006, to December 31, 2019, who had a de novo CIED implantation and a CIED infection more than 1 year after implantation. Data were analyzed from January 1, 2005, to December 31, 2019. Exposure: A CIED infection, defined as (1) endocarditis or infection of a device implant and (2) documented antibiotic therapy. Main Outcomes and Measures: The primary outcomes of interest were device infection, device extraction, and all-cause mortality. Time-varying multivariable Cox proportional hazards regression models were used to evaluate the association between extraction and survival. Results: Among 1 065 549 patients (median age, 78.0 years [IQR, 72.0-84.0 years]; 50.9% male), mean (SD) follow-up was 4.6 (2.9) years after implantation. There were 11 304 patients (1.1%) with CIED infection (median age, 75.0 years [IQR, 67.0-82.0 years]); 60.1% were male, and 7724 (68.3%) had diabetes. A total of 2102 patients with CIED infection (18.6%) underwent extraction within 30 days of diagnosis. Infection occurred a mean (SD) of 3.7 (2.4) years after implantation, and 1-year survival was 68.3%. There was evidence of highly selective treatment, as most patients did not have extraction within 30 days of diagnosed infection (9202 [81.4%]), while 1511 (13.4%) had extraction within 6 days of diagnosis and 591 (5.2%) had extraction between days 7 and 30. Any extraction was associated with lower mortality compared with no extraction (adjusted hazard ratio [AHR], 0.82; 95% CI, 0.74-0.90; P < .001). Extraction within 6 days was associated with even lower risk of mortality (AHR, 0.69; 95% CI, 0.61-0.78; P < .001). Conclusions and Relevance: In this study, a minority of patients with CIED infection underwent extraction. Extraction was associated with a lower risk of death compared with no extraction. The findings suggest a need to improve adherence to guideline-directed care among patients with CIED infection.


Asunto(s)
Desfibriladores Implantables , Endocarditis , Humanos , Masculino , Anciano , Estados Unidos/epidemiología , Femenino , Desfibriladores Implantables/efectos adversos , Estudios de Cohortes , Medicare , Factores de Riesgo
13.
Lancet ; 402(10408): 1147-1157, 2023 09 30.
Artículo en Inglés | MEDLINE | ID: mdl-37634520

RESUMEN

BACKGROUND: Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS: This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS: Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION: Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING: Medtronic.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Femenino , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Estudios Prospectivos , Resultado del Tratamiento , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Volumen Sistólico , Electrocardiografía
15.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37552791

RESUMEN

AIMS: Heart rate score (HRSc), the per cent of atrial paced and sensed event in the largest 10 b.p.m. rate histogram bin of a pacemaker, predicts survival in patients with cardiac devices. No correlation between HRSc and development of atrial fibrillation (AF) has been reported. In this study, we evaluated the relationship between pacemaker post-implantation HRSc and the incidence of newly developed atrial tachyarrhythmias (ATAs). METHODS AND RESULTS: Patients with dual-chamber pacemakers, implanted 2013-17, with the LATITUDE remote monitoring data with ≥600 000 beats of histogram data collected at baseline were included (N = 34 543). Heart rate score was determined from the initial 3-month post-implantation histogram data. Patients were excluded if they had ATAs, defined as atrial high-rate episodes >5 min or >1% of right atrial beats >170 b.p.m. during the initial 3 months post-implantation. New ATAs, after the baseline period, were defined by each of the following: >1, >10, or >25% of atrial beats >170 b.p.m. or atrial tachycardia response (ATR) events >24 h. Patients were followed a median of 2.8 (1.0-4.0) years. The incidence of ATAs increased in proportion to HRSc (log-rank P-value <0.001), and the initial HRSc ≥70% was associated with increased ATAs by all definitions. Patients with initial HRSc ≥70% were older, had a higher percentage of right atrium pacing (%RA pacing), had a lower percentage of right ventricular pacing (%RV pacing), and were more likely programmed with rate-response vs. subjects with HRSc <70%. Initial HRSc (hazard ratio: 1.07, 95% confidence interval: 1.05-1.09; P < 0.0001) independently predicted ATAs after adjusting for age, gender, %RV pacing, and rate-response programming. The %RA pacing and initial HRSc were correlated. CONCLUSION: Heart rate score independently predicts any subsequent duration of ATAs in pacemaker patients.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Humanos , Frecuencia Cardíaca/fisiología , Marcapaso Artificial/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Atrios Cardíacos , Taquicardia/diagnóstico , Taquicardia/epidemiología , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos
18.
JACC Asia ; 3(3): 321-334, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37323870

RESUMEN

In a contemporary setting, where the risk of sudden cardiac death (SCD) is low, heart failure management is improved, and technology is advanced, identifying the patients who would benefit the most from an implantable cardioverter-defibrillator (ICD) treatment for primary prevention remains a challenge. The prevalence of SCD is lower in Asia when compared with the United States/Europe (35-45 per 100,000 person-years vs 55-100 per 100,000 person-years, respectively). Nevertheless, this should not explain the enormous gap in ICD's utilization among eligible candidates (∼12% in Asia vs ∼45% in the United States/Europe). The disparity between Asia and Western countries, together with significant variation among the Asian population and the previously mentioned challenges, requires an individualized approach and specific regional recommendation, especially in countries with limited resources where ICDs are being extremely underutilized This review focuses on the current knowledge of ICD therapy for SCD prevention and how to improve patient and device selection.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA